openpath OPR2LHF Smart Reader v2 Instruction Manual
- June 6, 2024
- openpath
Table of Contents
Smart Reader v2 Installation Instructions
Openpath Security, Inc. 13428 Maxella Ave, #866 Marina del Rey, CA 90292 1-844-673-6728
Mounting Instructions
The Standard Reader (OP-R2-STND) can be flush-mounted on a single gang box or
surface mounted using the provided backplate.
Standard Reader Installation – Flush Mount
To Flush Mount (recommended):
- Install a recessed single gang box (D) into the wall.
- Strip and connect the wires.
- Use the provided screws (B) to attach the reader (C) to the wall. Do not use the provided backplate for flush mount installations.
- Snap-on the front cover (A).
NOTE : Do not use adhesive.
Dimensions:
No back cover, on gang box: 7.4 x 12.0 x 1.1 cm (2.9 x 4.7 x 0.43 in)
Standard Reader Installation – Surface Mount
NOTE : The flat side of the backplate should face the wall. No adhesives
are necessary.
To Surface Mount:
- If not installed on a gang box, place the reader (C) inside the backplate (E).
- Strip and connect the wires.
- Use wall anchors and the appropriate screws (not included) to attach the reader (C and E) to the wall.
- Snap-on the front cover (A). NOTE : Do not use adhesive.
Dimensions : With back cover, no gang box: 7.4 x 12.0 x 2.3 cm (2.9 x 4.7 x 0.9 in)
The Mullion Reader (0P-R2-MULL) can be surface mounted where space is limited,
like on a door frame.
Mullion Reader Installation
To Mount:
- Strip and connect the wires.
- If installing on a metal surface, drill and tap in order to use the provided screws (B). Or, use 310 self-tapping screws (not included). Attach the reader (G) to the wall.
- Snap-on the front cover (F).
NOTE : Do not use adhesive.
Dimensions : 4.3 x 11.9 x 2.2 cm (1.7 x 4.7 x 0.86 in)
Wiring Information
Gray | GND | Ground (RTN) | Primary ACU Connections |
---|---|---|---|
Blue | +B | RS485-B | |
Violet | -A | RS485-A | |
Orange | VIN | +12V IN | |
Red | VO | Wiegand Voltage | Connections to 3rd Party Wiegand Reader |
Black | GND | Wiegand RTN | |
Green | WDO | Wiegand Data 0 | |
White | WD1 | Wiegand Data 1 | |
Brown | LED | Wiegand LED | |
Yellow | BUZZER | Wiegand Buzzer |
The temperature should not exceed -22°F to 140°F (-30°C to 60°C)
Openpath readers and ACUs communicate via RS-485. The following wire types are compatible, listed in the order of preference which impacts distance:
- Shielded CAM (recommended, additional two pairs can be used for sensors)
- Shielded CAT6
- Shielded RS485 w/22-24AWG (lower gauge, thicker wire is better)
- Shielded CATS
- Unshielded CAT6
- Unshielded CATS Shielded 22/6
- Unshielded 22/6
NOTE : Use one twisted pair for GND and VIN and one twisted pair for +B
and -A.
Recommended maximum cable length: 300 ft (91 m) with CAT6 or 500 ft (152 m) if
two wire pairs are used for GND and VIN (power).
For shielded wiring: Connect one side of the drain wire (the shield
around the wires) to the GND terminal on the ACU. Both the shield and the GND
wire can share the same GND terminal. Do not connect the other side of the
shield to anything.
Status LED Color Codes
the center dot is solid white | entry is locked |
---|---|
the outer ring is solid white | entry is unlocked |
center dot flashes multiple colors, the outer ring quickly spins once |
the reader has just received power
all lights are off| the reader not connected to power (check to see if
the power wires are swapped
the center dot is flashing red| the reader is connected to power but
cannot communicate with the ACU (check to see if the +B [blue] and -A [violet]
lines are swapped)
center dot is solid blue| the reader not configured as an entry in the
Control Center
the center dot is solid green and the outer ring is solid white| the
center dot is solid green and the reader has been identified via the outer
ring is solid white Control Center
the center dot is solid purple and the outer ring is solid white| the
reader not receiving enough voltage center dot is solid purple and or current
– try connecting the reader the outer ring is solid white directly to the ACU,
bypassing any wire runs
the center dot is solid pink and the outer ring is solid white| check
that +12V IN (orange) hasn’t been swapped with +B (blue) or -A (violet)
Compliance
Any changes or modifications not expressly approved by the party responsible
for compliance could void your authority to operate the equipment. Note: This
equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy, and if it is not
installed and used in accordance with the instruction manual, it may cause
harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference, in which case the
user will be required to correct the interference at his own expense. This
equipment complies with FCC RF radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
a minimum distance of 20 centimeters between the radiator and your body.
WARNING : Operation of this equipment in a residential environment could
cause radio interference.
WARNING : This is a class A product. In a domestic environment, this
product may cause radio interference in which case the user may be required to
take adequate measures.
Industry Canada Notice and Marking This device comply with the ISED radiation
exposure limit set forth for an uncontrolled environment. This device should
be installed and operated with a minimum distance of 20cm between the radiator
& your body. This transmitter must not be co-located or operating in
conjunction with any other antenna or transmitter.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: 1) this device may not cause harmful
interference and (2) this device must accept any interference received,
including interference that may cause undesired operation.
The frequency and the maximum transmitted power in the EU is listed below:
Bluetooth LE(2402-2490MHz): 2 dBm
Need Help?
Technical support
support@openpath.com
1-844-673-6728 ext 2
openpath.com/support
Install guides
6709A3823000
2021/03/22| 1/1| mm| Dona
| Aubert| Rennier|
Senao Networks, Inc.
https://www.openpath.com/installation- manuals?utm_source=sdcv1&utm_medium=qr
Smart Reader v2 OP-R2-STND,
OP-R2-MULL
Power rating: 12/24VDC= 0.25/0.12A
Don’ t print this page.
Material 1100p Ink Extended size I 139.7(H)285.75(W) mm
Molding size I 139.7(H)95.25(W) mm
Molding method
Documents / Resources
|
openpath OPR2LHF Smart Reader
v2
[pdf] Instruction Manual
OPR2LHF, 2APJVOPR2LHF, OPR2LHF Smart Reader v2, OPR2LHF, Smart Reader v2
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>