Safety instructions

Always disconnect the fixture from AC power before cleaning, servicing or installing. Make sure the supply/data cable cord is not damaged by sharp edges. Do not install the fixture near an open flame. Refer servicing to qualified service personnel

This fixture falls under protection class I. Therefore this fixture has to be connected to a mains socket outlet with a protective earthing connection.

Do not connect this fixture to a dimmer pack.

LED light emission. Risk of eye injury. Do not look into the beam from a short distance without suitable protective eyewear. Do not look at LEDs with magnifiers or similar optical instruments that may concentrate the light output. Avoid brute force when installing or operating the fixture. The fixture was designed for outdoor use. This fixture must not be used for underwater installation. When choosing the installation spot, please make sure that the fixture is not exposed to extreme heat or dust. Avoid using the unit in locations subject to possible impacts. The fixture body never must be covered with cloth or other materials when the fixture is under operation. Only operate the fixture after having checked that the housing is firmly closed and all screws are tightly fastened. The fixture becomes hot during operation. Allow the fixture to cool approximately 30 minutes prior to servicing or maintenance. Dismantling of the unit in case of its repair must not be carried out in rain.

Eminere Inground Wireless DMX

Immunity of the equipment is designed for electromagnetic environments E1, E2, E3 according to the standard EN55103-2 ed.2 Electromagnetic compatibility. Product family standard for audio, video, audiovisual and entertainment lighting control apparatus for professional use. Part 2: Immunity. The installation company should check levels of possible interferences above the tested levels E1,E2,E3 given by this standard (e.g. transmitters in surrounding area) before installing the equipment. Emission of the equipment complies with the standard EN55032 Electromagnetic compatibility of multimedia equipment – Emission Requirements according to class B. Please consider that unauthorized modifications on the fixture are forbidden due to safety reasons! Operate the fixture only after having familiarized yourself with its functions. Do not permit operation by persons not qualified to operate the fixture. If this device will be operated in any way different to the one described in this manual, the product may suffer damages and the warranty becomes void. Furthermore, any other operation may lead to dangers like short- circuit, burns, electric shock etc.

Fixture exterior view

ANOLiS-Eminere-Inground-2-4-Wireless-DMX-
fig-1

Installation

The unit must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations. This device falls under class one and must be grounded! With respect to the purpose of using the unit, the residual current circuit breaker is highly recommended.

Mounting the Eminere Inground

If the Eminere Inground will be exposed to max. allowed static load, the subsoil under the installation sleeve has to withstand load of: 45kN (standard covering glass) 23kN (antiskid covering glass).

Example of installation of the Eminere Inground 2

  1. Prepare an adequate hole with a good drainage leaving at least 300 mm of gravel on the bottom of the hole for inserting the mounting sleeve (1) into the prepared hole. There must not stay water in the mounting sleeve.ANOLiS-Eminere-Inground-2-4-Wireless-DMX-fig-2
  2. Remove the temporary cover (4) from the mounting sleeve (1) by unscrewing the six cap head allen bolts (5).
  3. In sleeve that Emineres inground wil be installed side by side, the four holes (10) on the side of the mounting sleeve serve for attaching next mounting sleeve by means of the four screws M5x10 (2) (with washer and nuts). Two rubber grommets (3) insert to the holes (9) on the side of the mounting sleeve which you will use for passing cables to next mounting sleeve (the rubber grommets insert to holes after screwing both mounting sleeves together).
  4. The connection points (7) serve for grounding the Eminere inground and the mounting sleeves each other.ANOLiS-Eminere-Inground-2-4-Wireless-DMX-fig-3
  5. Connect the Eminere Inground (13) and all needed cables to the junction box (8). Note: the cabel (11) of the Eminere Inground is 2 m long, we recommend to shorten the cable on 1 m. The supply cable to the mounting sleeve and power/data cable from the mounting sleeve must be placed in a protective tube (12).ANOLiS-Eminere-Inground-2-4-Wireless-DMX-fig-4
  6. After connecting cables to the junction box (8), screw the Eminere Inground (13) to the mounting sleeve (1) by means of the four countersunk- allen head bolts M5x25 (14). The screws (14) must be tightened smoothly with torque of 4Nm. Do not use impact wrench.
  7. Screw the cover plates (15), (22) on the mounting sleeve (1) by means of the six countersunk- allen head bolts M5x30 (16). The crews (16) must be tightened smoothly with torque of 4Nm. Do not use impact wrench.

Junnction box
The Eminere Inground is equipped with auto-switching power supply that automatically adjusts to any 50-60Hz AC power source from 120-277 Volts.

Do not connect (disconnect) Emineres Inground each other when they are under voltage

Unscrew the four screws M4x20 (17) on the cover of the junction box and remove this cover (18) with gasket (19) to get access to the connection block (20 ).ANOLiS-Eminere-Inground-2-4-Wireless-DMX-fig-5

Connect cables to the connection block (20).

Wiring of the Eminere cable (CE version)

Core Power Connection
Brown L
Blue N
Yellow/Green  (earth)

Wiring of the Eminere cable (US version)

Core Power Connection
Black L
White N
Green  (earth)

The three cable glands M20 (21) are intended for cable of diameter of 6-12mm

Cable gland M20ANOLiS-Eminere-Inground-2-4-Wireless-DMX-
fig-7

We recommend to apply an adequate layer of the paste LOCTITE 5331 on the plastic holder of the cable gland before inserting it into the body of the gland and an adequate layer of the paste LOCTITE 577 on the thread of the gland body in case that you need to unscrew and remove the cable gland from the housing of the junction box and and screw it back to the housing. Remove end caps from cable glands before passing cables into the junction box. Fully tighten cable gland nuts and check that cables are properly fastened in the cable glands.

Note: every cable gland has to be covered with the end cap if this cable gland is not used for cable passing.
After checking all connections, fill the junction box with synthetic resin. Make sure that the End cap is inserted in unused cable gland and the earth wire for cover is pulled out of the junction box before filling it. At filling of the junction box proceed according instructions stated on the bag of the resin. The connection box (20) has to be fully poured in the resin

Prepared junction box and resin bag.ANOLiS-Eminere-Inground-2-4-Wireless-
DMX-fig-8

Junction box filled with resin.ANOLiS-Eminere-Inground-2-4-Wireless-DMX-
fig-9

Screw the cover (18) with gasket (19) to the junction box by means of the four screws (17) and check they are fully tighten.

If you install two or more Emineres Inground side by side, you have to screw three types of the cover plates: end (15), middle (23) and continuous (22). Insert the cover plate middle (23) between two mounting sleeves and screw rest of cover plates to the Emineres Inground by means of the countersunk allen head bolts M5x25 (16).ANOLiS-Eminere-Inground-2-4-Wireless-DMX-
fig-10

Cover plates overviewANOLiS-Eminere-Inground-2-4-Wireless-DMX-
fig-11

  • Cover plate end (optional )
  • Cover plate continuous (optional)
  • Cover plate middle (one piece is a standard part of fixture)

Tilt adjustment. The Eminere Inground can be tilted by +/-15° after installing it in the mounting sleeve. Push and hold the small tube (24) to release the lock of the Eminere Inground and tilt the device to desired position. Release the small tube (24) to lock the new position of the Eminere IngroundANOLiS-
Eminere-Inground-2-4-Wireless-DMX-fig-12

DMX addressing of connected Emineres Inground has to be done manually by means of the Robe Universal Interface WTX and the software RDM Manager

Direct visibility between a transmitter and the Eminere Inground Wireless DMX must be ensured without no obstacles (bildings, trees, cars….). The angle between the ground with the Eminere Inground Wireless DMX and the transmitter´s antenna has to be more than 10°. Distance between a DMX transmitter and the Eminere Inground Wireless DMX depends on transmission range of used DMX transmitter, surrounds etc (we recommend to test behaviour of DMX transmitter with the Eminere Inground Wireless DMX before installation ).ANOLiS-Eminere-Inground-2-4-Wireless-DMX-fig-13

Examples of connectionANOLiS-Eminere-Inground-2-4-Wireless-DMX-
fig-14

  • The Eminere Inground can be only linked to a transmitter by running the link procedure at DMX transmitter .
  • The Eminere Inround can be unlinked from the transmitter by running the unlink procedure at DMX transmitter or
  • by switching off/on the Eminere Inground three times while the transmitter is switched off.
  • During off/on unlink procedure, the Eminere Inground has to be switched on for 5 seconds in steps 1-3:
  • Step 1: Eminere Off, Eminere On (5s)
  • Step 2: Eminere Off,Eminere On(5s)
  • Step 3: Eminere Off, Eminere On (5s)
  • Step 4: Eminere Off, Eminere On
  • Successful unlink is signalized by flashing LEDs at fourth switching the Eminere inground Off and On. If the LEDs
  • flashing will not appear, probably the 5 seconds period has not been kept and you have to repeat the Off/On
  • procedure to unlink the fixture from the DMX transmitter .

DMX addressing of connected Emineres Inground has to be done manually by means of the Robe Universal Interface WTX and the software RDM Manager

Theoretically up to 32 Emineres Inground can be connected in DMX chain, but number of connected Emineres Inground in series also depends on their cable length, power voltage and type of Emineres Inground.
The tables below state max. theoretical number of Emineres connected in series without Booster boxes.

Eminere Inground 2 Wireles DMX Voltage
Cable length * 120V
10 m 32
20 m 32
30 m 28
50 m 17
70 m 12
100 m 9
Eminere Inground 4 Wireles DMX Voltage
--- ---
Cable length * 120V
10 m 21
20 m 21
30 m 15
50 m 9
70 m 6
100 m 4

Cable length is a total cable length among connected Emineres Inground including power cable of the first   Eminere Inground

Example of connectionANOLiS-Eminere-Inground-2-4-Wireless-DMX-
fig-15 Max. total cable length must not exceed 100m.

Technical specifications

Power supply

  • Electronic auto-ranging
  • Input voltage: 120 – 277V AC, 50-60 Hz
  • Power consumption

Eminere Inground 2: 50W
Eminere Inground 4: 90W

  • Inrush current

Eminere Inground 2: <70A/250μs
Eminere Inground 4: <100A/200μs

Optic

  • Light source

Eminere Inground 2: 24 x high power LEDs
Eminere Inground 4: 48 x high power LEDs

  • Colour variants: RGBW (W – 6500 K), RGBA, WW (W – 3000 K)
  • Beam angles: Symetrical: 9°, 15°, 30°, 50°, 65°, 100°

Bi-symetrical: 10° x 30°, 30° x 10°, 10° x 60°, 60° x 10°, 35° x 70°, 70° x 35°, 15° x 90°,
90° x 15°
Anti- Skid (symmetrical): 18°, 22°, 35°, 50°, 65°, 100°
Anti-Skid (Bi-symmetrical): 20° x 35°, 20° x 65°, 20° x 90°, 40° x 70°
Wallwasher, Wide Wallwasher

  • Projected Lumen Maintenance: L90B10 >90.000 hrs, Ta = 25°C / 77°F

Interface Protocol

  • USITT DMX512, RDM

Mounting method

  • Inground mount

Adjustability

  • +/- 15° after instalation

Housing

  • High pressure extruded aluminium body
  • End caps – Die-Cast Aluminium
  • Welded instalation sleeve for pre-instalation
  • Tempered glass

Cooling system

  • Convection

Total heat dissipation

  • Eminere Inground 2: 130 BTU/h (calculated)
  • Eminere inground 4: 228 BTU/h (calculated)

Protection factor

  • CE: IP 67
    US: Suitable for wet location

Impact rating

  • CE: IK09

Max. static load

  • Standard tempered glass: 45kN
  • Antiskid tempered glass: 23kN

Operating ambient temperature range

  • -20°C /+40°C (-4°F /+104°F)

Operating temperature

  • +80 °C @ Ambient +40 °C (+176 °F @ Ambient +104 °F)

Connection

  • Junction box

Weight

  • Eminere Inground 2: 23.6 kg / 52 lbs (12.2 kg / 26.9 lbs Eminere Inground 2 Fixture, 11.4 kg / 25 lbs install. Sleeve)
  • Eminere Inground 4: 43.85 kg/ 96.67 lbs (22.65 kg / 49.93 lbs Eminere Inground 4 Fixture, 21.2 kg / 46.74 lbs Install. Sleeve)

Dimensions

  • (All dimensions in mm [inch])
  • Eminere Inground 2/Eminere Inground 4ANOLiS-Eminere-Inground-2-4-Wireless-DMX-fig-16

Dimensions with mounting sleeve (All dimensions in mm [inch])

Eminere Inground 2/Eminere Inground 4ANOLiS-Eminere-Inground-2-4-Wireless-
DMX-fig-17

Included items

  • 1 x Eminere Inground
  • 1 x mounting sleeve
  • 1 x User manual

Cleaning and maintenance

Rinse off loose dirt with low pressure water spray. Wash the housing with a soft brush or sponge and a mild, nonabrasive washing detergent. Rinse it. Maintenance and service operations are only to be carried out by a qualified person. Should you need any spare parts, please use ROBE OEM parts

Disposing of the product

To preserve the environment please dispose or recycle this product at the end of its life according to the local regulations and codes

ChangeLog

This section summarizes changes in the user manual.

Version of the manual Date of issue Description of changes
1.1 08/09/2021 Option Wireless DMX to wired DMX removed
1.2 19/10/2021 Technical specifications changed
1.3 26/11/2021 Optional accessories changed
1.4 08/03/2022 Screw lengths changed
1.5 19/05/2022 QR code added

Specifications are subject to change without notice. May 19, 2022
Copyright © 2019-2022 Robe Lighting – All rights reserved   Made in CZECH REPUBLIC by ROBE LIGHTING s.r.o. Palackeho 416/20 CZ 75701 Valasske Mezirici