- Splicing wire connection
- Functions Instruction (for specific function, please refer to actual
- Daylight & Microwave Sensor
- Factory settings
- Wiring settings
- Induction Range
- Important Safety Instructions
- Installation Procedure
- Surface Mounted Installation
- Suspended Installation
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
**NEDLANDS GROUP WBB-38W-CC LED Batten Wide Body Installation Guide
**
Splicing Installation
Splicing wire connection
Functions Instruction (for specific function, please refer to actual
model)
Sensor
Detection area: 150 degree wide detective beam angle with 4-7 meters
distance.
Daylight & Microwave Sensor
Sensor Setting:
Detection area
1| 2|
---|---|---
ON| ON| 100%
ON| –| 75%
–| ON| 50%
–| –| 25%
Detection area:
Detection area can be reduced by selecting the combination on the DIP switches
to fit precisely each application.
Notice 1: The test is based on a height of 3m, the radius is the ground
detect distance, which can be selected through the slide switch.
Notice 2: The detective range is measured by human body whose stature is
around 1.6-1.7M with medium size and traveling speed is around 1.0-1.5M per
second. If the stature, bodily form and traveling speed are changed, then the
detective range will be changed accordingly.
Notice 3. Test result will be highly influenced by test environment,
the more open environment, the closer detect distance, the narrower
environment, the longer detect distance. The detectormay do self-excitation in
a narrow environment.
Hold time
3| 4| 5|
---|---|---|---
ON| 4| ON| 5S
ON| ON| –| 30S
ON| ON| ON| 1min
ON| –| –| 3min
–| –| ON| 5min
–| ON| –| 10min
–| ON| ON| 20min
–| –| –| 30min
Hold time:
Refers to the time period the lamp remains at 100% illumination after no
motion detected.
Notice 1: The hold time can be selected by the slide switch The hold time
counting should be started after the sensor is powered on and initialized.
Daylight sensor
6| 7| 8|
---|---|---|---
ON| ON| ON| 2Lux
ON| ON| | 10Lux
–| ON| | 25Lux
ON| –| | 50Lux
–| –| | Disable
Daylight sensor:
The sensor can be set to only allow the lamp to illuminate below a defined
ambient brightness threshold. When set to Disable mode, the daylight sensor
will switch on the lamp when motion is detected regardless of ambient light
level.
No t ice 1: The light threshold can be selected through the slide
switch, it may cause a large deviation in different lamps.
Factory settings
Detection Area | Hold Time | Daylight Sensor |
---|---|---|
100% | 60S | 25Lux |
Wiring settings
Induction Range
High detection area
Low detection area
Important Safety Instructions
To ensure correct function and safety, please read and follow all instructions carefully before using the product:
- Turn off power before installation or before doing any maintenance work.
- Do not install any luminaire near the heat source.
- Do not exceed the nominal supply voltage or amperage ratings.
- All wiring and installation of the light fitting must adhere to local and national wiring rules.
- Take care not to pull any electrical wires during unpacking as this may damage the connection.
- Lay out all the components on a smooth surface and make sure there are no components missing before assembling.
- To avoid injury or damage to the fitting, please ensure that power leads and screws are secure before connecting the power.
- Please keep instructions for future reference
Installation Procedure
WARNING
- Switch off before installation.
- Switch on only after complete installation and examination of the circuit.
Turn Off Power Supply
Turn Off power supply before starting any installation. Read instructions &
check you have all the tools & accessories to complete the installation
correctly.
The light source contained in this luminaire shall only be replaced by the
manufacturer or his service agent or a similar qualified person.