MAXIMUM DOOR WEIGHT…………………. 50kg
MAXIMUM DOOR HEIGHT………………………… 2100mm
DOOR THICKNESS………………………………. 20 – 50mm
TRACK LENGTH AND BRACKET SPACING
Track supplied in standard length 1800mm and 2400mm.
01030/40 brackets are supplied in packs of 3 or 4 complete with all screws. Equally space the side fixing bracket along the length of the track.
Note: Track can also be Soffit mounted by screwing throught the track into the support above.

Trackset Components

01818 01824

Hanger Pack
01050| 1| Hanger Pack
01050| 1
Bracket pack
01030| 1| Bracket Pack
01040| 1
Aluminium Track
11818| 1| Aluminium Track
11824| 1

Note: Hanger Pack includes 2 hangers with nylon wheels and integral ball bearings, 1 pair of track end pieces, door guide, spanner and fitting instructionsCOBURN Straightaway 50 Internal Sliding Door System fig
1For side fixing brackets, drill Ø5.5mm holes along the centre line of the track. Drill the first and last holes so they are 50mm from the ends of the track, space the remaining holes equally betweeen these holes.

Assemble brackets to track as shown in ‘A’ before fixing onto wall.
Insert hangers with pendant bolts into track (see ‘B’ or ‘C’) followed by assembly of the track end piece.
If Soffit mounting the track, pre-drill Ø4mm holes along the centre line of the track. Space the holes equally across the length of the track. First and last holes should be 50mm from the ends of the track. Use the wall screws in the bracket pack to then secure the track through the predrilled holes into the support above.

COBURN Straightaway 50 Internal Sliding Door System fig
3

Assembly of Timber door hanger.

Thread hexagon nut on to pendant bolt to within 5.5mm of head. Enter bolt in under side of hanger body to engage with thread in to the body. Screw bolt in until clear of nut. Screw door plate to door, flush with inside edge and such that the screw holes are clear of stiles. With hangers in track, offer door up and engage pendant bolts with slots of door plate, adjust vertically and laterally then tighten hexagon nut.

Door preparation

Make a routing on the bottom of the door (15x15mm) for the 44-373 guide.

COBURN Straightaway 50 Internal Sliding Door System fig
4Once the door is hung, fully open the door and place 44-373 guide half way into the routing and fix with a screw into the floor.
Fully close the door and fix the remaing screw to secure guide on the floor.
Note: the guide must remain inside the routing at all times.
CAUTION: Do not wind the Pendant Bolt all the way past the top of the Hanger, as this will stop the system from working properly

STRAIGHTAWAY 50
TECHNICAL DATA (Fitting Instructions)
Coburn Sliding Systems Limited, Unit 1, Cardinal West, Godmanchester PE29 2XN