PHILIPS BGP235 TubePoint Gen2 Luminaire Range for Traffic Tunnels User Manual

June 4, 2024
Philips

PHILIPS BGP235 TubePoint Gen2 Luminaire Range for Traffic Tunnels

PHILIPS-BGP235-TubePoint-Gen2-Luminaire-Range-for-Traffic-Tunnels-
Product

TubePoint Gen2

Many tunnel authorities have an outdated tunnel-lighting installation that urgently needs to be replaced, but has only a limited budget available. We are able to fulfill their requirements. TubePoint GEN2 is the result of years of experience in tunnel lighting combined with the latest technologies developed by Philips. With its modular design and modern LED architecture, TubePoint GEN2 is a versatile, cost-effective luminaire that meets the most stringent tunnel-lighting requirements. It is made of the highest-quality components that are dedicated to tunnels, thus ensuring a long lifetime, good performance, and low maintenance costs. The efficiency and wide choice of optics mean that the number of luminaires can be reduced significantly compared with a conventional solution. And a high lumen per watt ratio at the system level improves the total cost of ownership. TubePoint GEN2 is part of Philips’ TotalTunnel solution for complete tunnel lighting.

Benefits

  • The flexible mounting solution, quick release for easy maintenance
  • Easy-connect, a wide range of connectivity options
  • Excellent quality optics, longer distance between luminaires
  • Fast payback
  • Equipped with a service tag, a QR-based identification system that makes each luminaire uniquely identifiable and provides maintenance, installation and spare part information.

Features

  • Direct replacement of existing conventional luminaires (Lumen packages exceeding SON-T 400 W)
  • Flexibility in application thanks to a range of lumen outputs and tunnel optics
  • Compatible with Philips’ tunnel controls and options for third-party controls
  • Option of the remote driver for quick and easy maintenance
  • Wide choice of mounting systems

Application

  • Traffic tunnels and underpasses

Versions

PHILIPS-BGP235-TubePoint-Gen2-Luminaire-Range-for-Traffic-Tunnels-
fig-1

Product Details

PHILIPS-BGP235-TubePoint-Gen2-Luminaire-Range-for-Traffic-Tunnels-
fig-2
PHILIPS-BGP235-TubePoint-Gen2-Luminaire-Range-for-Traffic-Tunnels-
fig-3

Specification

Application conditions|  |  | |
---|---|---|---|---
Maximum dimming level| 10%|  | Order Code| Full Product Name| Driver failure rate at 5,000 hours
 |  |  | 48290900| BGP235 LED30-4S/740 DSM11 D9 MIO-CIO MBQ| 0.53 %
Approval and application|  |  | 48291600| BGP235 LED50-4S/740 DSM11 D9 MIO-CIO MBQ| 0.5 %
Mech. impact protection code| IK09|  | 48292300| BGP235 LED90-4S/740 DSM11 D9 MIO-CIO MBQ| 0.5 %
Surge protection (common/| Luminaire surge|  | 48293000| BGP235 LED120-4S/740 DSM11 D9 MIO-CIO MB| 0.5 %
differential)| protection level|  | 48294700| BGP235 LED180-4S/740 DSM11 D9 MIO-CIO MB| 0.5 %
 | up to 6 kV|  | 48296100| BGP236 LED360-4S/740 DSM11 D9 MIO-CIO MB| 0.5 %
 | differential mode and 6 kV common

mode

|
 |
Controls and dimming|
Dimmable| Yes
 |
General information|
Luminaire light beam spread| 101° x 158°
CE mark| CE mark
Light source colour| 740 neutral white
Optical cover/lens type| FG
Driver included| Yes
Flammability mark| F
Light source replaceable| Yes
Optic type| Distribution symmetrical

medium 11

 |
Initial performance (IEC compliant)|
Init. Corr. Colour Temperature| 4000 K
Init. Colour rendering index| >70
 |
Light technical|
Standard tilt angle side entry| 0°
Standard tilt angle post-top| –
Upward light output ratio| 0
 |
Mechanical and housing|
Colour| Dark gray

General I nformation

|
---|---
 | Lamp|  | Number| Product|  |  | Lamp|  | Number| Product
 | family| Number of| of light| family|  |  | family| Number of| of light| family
Order Code Full Product Name| code| gear units| sources| code|  | Order Code Full Product Name| code| gear units| sources| code
48290900| BGP235 LED30-4S/740

DSM11 D9 MIO-CIO MBQ

| LED30| 1 unit| 20| BGP235|  | 48293000| BGP235 LED120-4S/740

DSM11 D9 MIO-CIO MB

| LED120| 1 unit| 40| BGP235
48291600| BGP235 LED50-4S/740

DSM11 D9 MIO-CIO MBQ

| LED50| 1 unit| 20| BGP235|  | 48294700| BGP235 LED180-4S/740

DSM11 D9 MIO-CIO MB

| LED180| 1 unit| 56| BGP235
48292300| BGP235 LED90-4S/740

DSM11 D9 MIO-CIO MBQ

| LED90| 1 unit| 28| BGP235|  | 48296100| BGP236 LED360-4S/740

DSM11 D9 MIO-CIO MB

| LED360| 2 units| 112| BGP236

Initial Performance (IEC compliant)

Order Code| Full Product Name| Initial luminous flux|  | Order Code| Full Product Name| Initial luminous flux
---|---|---|---|---|---|---
48290900| BGP235 LED30-4S/740 DSM11 D9 MIO-CIO MBQ| 2520 lm|  | 48293000| BGP235 LED120-4S/740 DSM11 D9 MIO-CIO MB| 9840 lm
48291600| BGP235 LED50-4S/740 DSM11 D9 MIO-CIO MBQ| 4200 lm|  | 48294700| BGP235 LED180-4S/740 DSM11 D9 MIO-CIO MB| 14940 lm
48292300| BGP235 LED90-4S/740 DSM11 D9 MIO-CIO MBQ| 7470 lm|  | 48296100| BGP236 LED360-4S/740 DSM11 D9 MIO-CIO MB| 29880 lm

Trademarks

© 2022 Signify Holding All rights reserved. Signify does not give any representation or warranty as to the accuracy or completeness of the information included herein and shall not be liable for any action in reliance thereon. The information presented in this document is not intended as any commercial offer and does not form part of any quotation or contract unless otherwise agreed by Signify. All trademarks are owned by Signify Holding or their respective owners. www.lighting.philips.com 2022, July 16 – data subject to change