iCT NE77 Bill Acceptor Installation Guide

June 3, 2024
ICT

NE77 Bill Acceptor
Installation GuideiCT NE77 Bill Acceptor

Bill Acceptor NE77

Installation Guide
International Currency Technologies Corp.
Use of Materials Limitations
International Currency Technologies Corporation {ICT) all rights reserved.
All materials contained are the copyrighted property of ICT.
All trademarks, service marks, and trade names are proprietary to ICT.
ICT reserves the right at all times to disclose or to modify any information as ICT deems necessary to satisfy any applicable law, regulation, legal process or governmental request, or to edit, refuse to post or to remove any information or materials, in whole or in part, in ICT’s sole discretion.

Introduction

1-1. Overview
NE77 features multi-width banknote verification and recognition and superior anti-stringing function; equipped with multiple interfaces to provide users the best service suitable for various applications.
1-2. Features

  • Accept multi-width banknotes
  • Advanced optical and mechanical anti-fishing mechanism
  • High acceptance rate
  • Superior anti-counterfeit capability
  • High transaction speed

Specifications

General
Note: The incomplete bills such as extremely dirty, wet, broken or wrinkled ones are excluded.

Acceptance Rate 96% or greater
Bill Insertion Four way acceptable
Transaction Speed Approx. 1.5 seconds to stack
Interface RS232, Pulse, Parallel
Installation Indoor

Electrical

Power Source 12V DC (10.8V-13.2V DC)
Power Consumption Standby: 0.24A, 3W

Operation: 0.9A, 11W
Maximum: 2.7A, 32.4W
Operation Environment| Operation Temperature: 0°C-55°C
Storage Temperature: -20°C-?0°C
Humidity: 30%-85%RH (no condensation)

Mechanical

Outline Dimension Refer to page.4
Bill Accepted Width 62mm–77mm
Weight Approx. 1.2kg

Packing List

Main Bill Acceptor
Accessory Harnesses (Refer to 5-1)

NE77 Installation Guide
NE77 DIP Switch Setting Guide

Dimension

< long bezel > ![iCT NE77 Bill Acceptor fig 1](https://manuals.plus/wp- content/uploads/2022/12/iCT-NE77-Bill-Acceptor-fig-1.png)![iCT NE77 Bill Acceptor fig 2](https://manuals.plus/wp-content/uploads/2022/12/iCT-NE77-Bill- Acceptor-fig-2.png)

< Standard Bezel > Part number: 3RBA-FAC41003 iCT NE77 Bill Acceptor fig
3

**** To install the bill acceptor on your VMC, please be aware of the dimension as below:
[ L ] : Longer than the maximum length of accepted bills.
[ L 1 ] : Bill box capacity depth.

  • [ L/2 J has to be longer than 80mm to open upper base. iCT NE77 Bill Acceptor fig 4

Installation

5-1 . Harness Application
5-1 TABLE 01

Interface Used Voltage Usage Harness Page
Pluse 12V DC Power & *Data comm. WEL-NE7708 8
RS232 N/A *Data comm. WEL-RNK10-1
or 2-BA-RNK10 9

*Date Comm.: Data Communication.
5-1 FIG.01iCT NE77 Bill Acceptor fig 5iCT NE77 Bill
Acceptor fig 6 5-1-1. 1/0 Circuit
Pulse Interface-1iCT NE77 Bill Acceptor fig 7iCT NE77 Bill
Acceptor fig 10iCT NE77 Bill Acceptor fig 9iCT NE77 Bill
Acceptor fig 8

5-2. DIP Switch Setting
There’s a serial DIP switches which is located on the side of NE77.
According to different currencies or interfaces which are used by users, DIP switch settings could be varied to fit users’ need. Please refer to “NE77 DIP Switch Setting” Guide in the package for more detail.iCT NE77 Bill Acceptor
fig 11

5-3. Software Download and Upgrade
To download and upgrade the software to NE77, the programmer (FP-004) is needed. Please contact ICT to purchase FP-004 and refer to FP-004 user guide for software download and upgrade information.iCT NE77 Bill Acceptor fig
12

Turn on Bill Acceptor after connecting.

Maintenance

To make sure the bill acceptor always works smoothly, please clean
the internal parts regularly.
To clean the internal parts:

  1. Turn Bill Acceptor off.
  2. Press the buttons on the side of bill path and pull the unit out.
  3. Use a soft, dry cloth, or towel to clean the bill path and sensors.

iCT NE77 Bill Acceptor fig 13

Maintenance Notice
(Any improper maintenance will result invalid warranty.)

| Recommended| Mild, non-abrasive, soap water.
---|---|---
DO NOT USE| Organic solvent , Alcohol, Volatile liquid.

Troubleshooting

Flashes Status Corrective Actions
Red Green
1 1 Bill Jammed
2 1 BA Inhibit
3 Judge Sensor / Input Sensor Error

or bill path and clean.
3| 1| Anti-fishing Sensor Error| Inspect for foreign objects on sensor or bill path and clean.
3| 2| Hook Error| Inspect for foreign objects on sensor or bill path and clean.
3| 4| Output Sensor Error| Inspect for foreign objects on sensor or bill path and clean.
4| 1| Fish| Inspect for foreign objects on sensor or bill path and clean.
7| 1| Motor Error| Inspect for foreign objects on sensor or bill path and clean.

**** If the error can not be solved after corrective actions or happen again, please contact ICT for technical support.

International Currency Technologies Corporation
No.28, Ln. 15, Sec. 6, Minquan E. Rd., Neihu Dist., Taipei City 114, Taiwan
[email protected] (For Sales)
[email protected] (For Customer Service)
Website: www.ictgroup.com.tw
© 2014 International Currency Technologies Corporation
V. 8.0 Part Number: H6569G-R

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ICT User Manuals

Related Manuals