CC6100 series

Quick Start Guide

International Currency Technologies Corp.

Use of Materials Limitations
International Currency Technologies Corporation (ICT) all rights reserved.
All materials contained are the copyrighted property of ICT.
All trademarks, service marks, and trade names are proprietary to ICT.
ICT reserves the right at all times to disclose or to modify any information as
ICT deems necessary to satisfy any applicable law, regulation, legal process, or governmental request, or to edit, refuse to post or to remove any information or materials, in whole or in part, in ICT’s sole discretion.

Before use

Dear Valuable customer, thank you for purchasing CC6100. CC6100 features six modular coin tubes to provide the highest level of flexibility in managing payout combinations. Japan Standard Communication Interface (JPSTD), MDB, and Executive interface are available, to support multiple applications.

Package Contents:

  • CC6100 with one of the following wire harness
    WEL-RCC23 Power and Data Communication cable for MDB.
    WEL-RCC24 Power and Data Communication cable for JPSTD.
    WEL-RCC72 & WEL-RCC54 Power and Data Communication cable for CC6100 Executive & MDB.

  • Quick Start Guide

CC6100 Installation instructions can be downloaded at: www.ictgroup.com.tw
Select “Support” from the menu, then select “Manual Download”.

Installation

Attention!! Prior to installation, please remove the coin changer from the carton and inspect for damages.
Attention!! Turn off VMC Power during installation-IMPORTANT!!!
Warning!! Do not plug both MDB and Executive connector to VMC board simultaneously!! It may cause damage to the VMC board.

Device Mounting Instruction
  1. Press the green hook at the left side of the coin changer and tilt the upper module.
  2. Unplug the flat cable to separate the upper module from the device.
  3.  Loosen the 3 mounting screws with 2 or 3 turns. (do not unscrew these completely) Lift the coin changer to mount inside the vending machine.
  4. Tighten the screws and place the upper module back to the device.
  5. Plug the flat cable back to the upper module then close the upper module till it is firmly fixed by the green hook.
    The plug device power and communication cable to the vending machine.
Tube Cassette Refill Instruction
  1. Press the green cassette fixed latch to pull out the cassette at an upwardly slanted angle.
  2. Refill coins into tube cassette and ensure that the coins enter the corresponding tubes and are flatly placed. Then place the tubing cassette back to Changer.

*You may choose coin refill mode to fill coins without an open tube cassette.

Installation Checklist

Check that there is a 3 to 5 mm gap between the coin changer return lever and the vending machine return mechanism.

Check that when vending machine return lever has been pressed and released, the reject rate of the coin recognition module can be opened and closed properly.

Check that the coin insertion, coin return box, and coin storage box channels of the vending machine line up with the corresponding slots of the coin changer. If the slot has not been lined up, please adjust accordingly.

Insert a coin to check whether it can pass through the coin changer successfully. Please ensure that there is no interference around the coin recognition module.

Initialization Checklist

While the vending machine is in an energized state, please DO NOT plug/unplug any wires on CC6100.
Please ensure that there are no interferences between the connected wires, the coin insert, and return device, and the door of the automatic vending machine. After the inspections are complete, then turn on the vending machine power.

Check the number of coins in each coin tube is above the minimum required level. Please refer to the sticker on the tubing cassette for minimum level information. (The coin changer would not work correctly without enough coins in the coin tubes.)
After refilling of tube cassette, the coin changer will detect the adequate coin quantity within a few seconds.

Dispense at least 1 coin from each coin tube to ensure that the dispensed coins fall into the coin return box of the vending machine.

Wiring

Wiring for CC6100 JPSTD Model or MDB Model

ICT Coin Changer provides the MDB or JPSTD cable only. Please let your sales representative know about your vending machine needs.

Wiring for CC6100 Executive & MDB Model

Warning!! Do not plug both MDB and Executive connecter to VMC board simultaneously!! It may cause damage to the VMC board.

LCM Module Description

KEY Function
A Tube A, move left
B Tube B, move upward
C Tube C, move right
D Tube D, back
E Tube E, move downward
F Tube F, enter
Manual Enter the main menu
LCM Main Menu Table

Operation functions

Code| LCM Menu Display|

Function Description

|
100| Refill Coin| Coin Refill Function by Coin Insertion under Cash Flow Mode.| Accessible without password. Cash Flow Mode only.
101| Total In/Out| Check the Total Coin PayIn and PayOut Value Counter.| Accessible without password
115| Clear Tube Count| Clear Counting Memory of All Coin Tube Inventory.| Accessible without password
129| Language| Set language.| Accessible without password

To access all menu functions requires password verification. Press “ D ” 3 times under the main menu to open the password input page. Default Password is ABCD. See next page for complete menu functions.

Setting Functions


Code

| LCM Display|

Function Description

|
102| Reset Records| Clear the Total Coin PayIn and PayOut Value Record.|
103| Accept/ Reject Coin Switch| Set Accept or Reject to Coin Denominations.|
104| Tube Open/ Close Switch| Set Open or Close to Coin Tubes.|
107| Configure Cash Float| Set Cash Float Configuration for Various Coin Denominations.| Cash Flow Mode only
108| Activate Cash Float| Set Cash Float Type for Various Coin Denominations.| Cash Flow Mode only
109| Check Current Cash Float| Check Current Cash Float of Various Coin Denominations.| Cash Flow Mode only
110| Change Mgmt.| Set the Change Return Mode.|
111| Idle Display| Set the Standby LCM Display Mode.|
112| BA Type Setting| Set the BA Interface.|
113| Default Setting| Restore to Default Factory Settings.|
116| Cassette Type| Coin Tube Configuration Mode.| Special Function
117| Error Info| Display Error Message Records.|
118| Bill(s) per Transaction| Set the Bill Acceptance Limitation for the BA.| ICT BA only
119| CashFloat Mode| Set Coin Tube Inventory Counting Mode.| Cash Flow Mode only
120| Set ID| Set Customer & Machine Number.|
121| Coin->CashBox Setting| Set Coin Acceptance to Cash Box Condition.|
122| Expansion Escrow Setting| Set Escrow for NTD 50.| Special Function, only for NTD
123| Sensor Inventory Adjustment| Detect Tube Inventory.|
124| Reserved Coin| Set Reserved Coin Function.|
125| Accessibility options| Set LCM accessibility under door-switch status and password security.|
126| Refill Coin Inventory| Refill Coin Inventory function by inserting coins into tube cassette directly.|
127| Residual Credit| Credit should remain on VMC.|
128| Token Learning Mode| Token learning mode.| For MDB & Executive
130| Reject Lever Setting| Set no refund after inserting payment.| For MDB & Executive
131| Acceptance limit For Changer| Set Credit Acceptance Limit.| Only MDB for KRW
132| Maximum for Insert Q’TY| Set limitation of coins in a single transaction.| Only MDB for KRW
133| Decimal and Scaling| Set Decimal point and Scaling Factor.| For MDB & Executive
134| Currency Code| Setting Currency Code.|
135| Error Report| Setting Error Report Function.|
136| Payout Method| Setting Payout Method(Level 2).|
137| Refill Option| Setting Refill Option.|
138| Channel sequence| Setting Channel sequence.|
139| IDR credit| Setting Indonesia Credit.| Only for Indonesia
140| EVA-DTS ID data| Setting EVA-DTS ID.|
141| Bill Escrow Return| Setting Bill Escrow Return.|
142| Sorting Module Testing| Setting Tube Test Mode.|
143| Tube Detection(after the sale)| Setting Tube Detection Function.| Only for Russia
144| Overpay| Set Overpay.| Only for UAH, USD, EUR
146| Resend Credit| Setting Resend Credit Function.|
147| RC Settings| Setting Recycle Function.|
148| VMC Reset TO VMC| Setting VMC reset Function.|
149| Refill Control(Full Tube)| Setting Refill Control.|
150| Low inventory report(real)| Setting Low inventory report.| Only for SGD, MYR, THB
151| Secure mode for THB coin| Setting Secure mode.| Only for THB
152| Fuji dispensing coin mode| Setting Fuji dispensing coin mode.| Only for THB
153| RFID deduction amount| RFID deduction amount setting mode.| JPSTD-TWD and THB
154| RS232 mode| RS232 mode setting.|
156| Set give changes order| TWD set gives changes to order.| Only for TWD
157| VMC support value| Set up VMC support value.|
158| Set up and write each tube stock of coins| THB set up and write each tube stock of coins.| Only for THB
160| JPY Amount display| JPY Amount display options| Only for JPY
161| NTD 50 special entry condition| NTD 50 special entry condition setting| Only for TWD

Executive Setting Functions


Code

| LCM Display|

Function Description

|
200| Sell Mode| Set Single Vend or Multi Vend.| Executive only
201| Price Display| Set Price Display on VMC.| Executive only
202| Product Price| Set Product Price Holding by Changer.| Executive only
203| Price Holding| Set Price Holding by Changer or VMC.| Executive only
204| 2nd Price for Cashless| Set 2nd price for cashless function on or off.| Executive only
205| Enable Bill Acceptance| Set BA enable with or without e-key.| Executive only
207| Residual Credit| Setup residual credit.| Executive only
208| Acceptance limit For Changer| Set Credit Acceptance Limit.| Executive only
209| Credit limit For Cashless| Set Credit limit for cashless.| Executive only
210| Bill(s) per Transaction| Set BA limitation per transactio.| Executive only
211| Exact Change Notice| Set exact change notice on display.| Executive only
212| Exact Rate| Set Exchange Rate.| Executive only
213| Overpay| Set Overpay.| Executive only

DIP Switch Setting

DIP Switch Setting for JPSTD, MDB

FUNCTION| SW1| SW2| SW3| SW4| SW5| SW6| SW7|

SW8

---|---|---|---|---|---|---|---|---
High anti-counterfeiting (1st coin value)| ON| | | | | | |
High acceptance (1st coin value)| OFF
High anti-counterfeiting (2nd coin value)| | ON
High acceptance (2nd coin value)| | OFF
High anti-counterfeiting (3rd coin value)| | ON
High acceptance (3rd coin value)| | OFF
High anti-counterfeiting (4th coin value)| | ON
High acceptance (4th coin value)| | OFF
Reserved| | ON
Reserved| | OFF
Reserved| | ON
Reserved| | OFF
Calibration Mode| | ON
Reserved| | OFF
Reserved| | ON
Reserved| | OFF

Note:

  • SW3-ON, High anti-counterfeiting: CNY $1, RUB $5, TWD $50
  • SW4-ON, High anti-counterfeiting: RUB $10
  • Acceptance rate setting, SW1 to SW4, is limited to some regions or denominations.
    Please contact your local dealer for further information.
DIP Switch Setting for EXECUTIVE

FUNCTION| SW1| SW2| SW3| SW4| SW5| SW6| SW7|

SW8

---|---|---|---|---|---|---|---|---
High anti-counterfeiting (1st coin value)| ON| | | | | | |
High acceptance (1st coin value)| OFF
High anti-counterfeiting (2nd coin value)| | ON
High acceptance (2nd coin value)| | OFF
High anti-counterfeiting (3rd coin value)| | ON
High acceptance (3rd coin value)| | OFF
High anti-counterfeiting (4th coin value)| | ON
High acceptance (4th coin value)| | OFF
Reserved (MDB)| | ON
Reserved (Executive)| | OFF
Reserved| | ON
Reserved| | OFF
Calibration Mode| | ON
Reserved| | OFF
Reserved| | ON
Reserved| | OFF

Note:

  • SW3-ON, High anti-counterfeiting: CNY $1, RUB $5, TWD $50
  • SW4-ON, High anti-counterfeiting: RUB $10
  • Acceptance rate setting, SW1 to SW4, is limited to some regions or denominations.
    Please contact your local dealer for further information.
DIP Switch Setting for CC6100SA

FUNCTION| SW1| SW2| SW3| SW4| SW5| SW6| SW7|

SW8

---|---|---|---|---|---|---|---|---
High anti-counterfeiting (1st coin value)| ON| | | | | | |
High acceptance (1st coin value)| OFF
High anti-counterfeiting (2nd coin value)| | ON
High acceptance (2nd coin value)| | OFF
High anti-counterfeiting (3rd coin value)| | ON
High acceptance (3rd coin value)| | OFF
High anti-counterfeiting (4th coin value)| | ON
High acceptance (4th coin value)| | OFF
Calibration Mode| | ON
Reserved| | OFF
Reserved| | ON
Reserved| | OFF
Reserved| | ON
Reserved| | OFF
Reserved (Turn off the sleep mode)| | ON
Reserved (Turn on the sleep mode)| | OFF

Note:

  • SW3-ON, High anti-counterfeiting: CNY $1, RUB $5, TWD $50
  • SW4-ON, High anti-counterfeiting: RUB $10
  • Acceptance rate setting, SW1 to SW4, is limited to some regions or denominations.
    Please contact your local dealer for further information.

Error Message

Code Cause LED
E10 LCM Panel Open 5 Red + 2 Red
E11 Checksum Error Red Light
E12 The signal from the coin base was not received when the power was
turned on. Red Light

E13

| Two seconds after activation, the SYSTEM did not wait for the READY signal from the DEVICE and jumped to the exception.| 1 Red
Two seconds after a transaction, the SYSTEM did not wait for the READY signal triggered by the DEVICE.
E14| Coil 1 is damaged.| 3 Red + 1 Red
E15| Coil 2 is damaged.| 3 Red + 2 Red
E16| Coil 3 is damaged.| 3 Red + 3 Red
E17| Low-level LED is damaged.| 3 Red + 5 Red
E18| Coin separator sensor problem.| 3 Red + 4 Red
E19| The deck is open for over 30 seconds.| 5 Red + 1 Red
E20| Both the first and second group motors cannot be positioned.| 7 Red
E21| The first motor group cannot be positioned. The first motor group might be damaged, coins or foreign objects might have caused the motor to stuck, coins are stuck in the coin tube, or the semicircle disk has derailed.| None
E22| The second motor group cannot be positioned. The second motor group might be damaged, coins or foreign objects might have caused the motor to stuck, coins are stuck in the coin tube, or the semicircle disk has derailed.|


None

E23| Broke away or incorrectly positioned coin tubes.| 5 Red
E24| Coins got stuck at the coin separation area or the coin tube opening twice in a row, causing the HI Level Sensor to fail to detect the coin twice in a row.| 6 Red + 4 Red
E25| “A” Tube Low Level = empty, HI Level = full at setup.| None
E26| “B” Tube Low Level = empty, HI Level = full at setup.| None
E27| “C” Tube Low Level = empty, HI Level = full at setup.| None
E28| “D” Tube Low Level = empty, HI Level = full at setup.| None
E29| “E” Tube Low Level = empty, HI Level = full at setup.| None
E30| “F” Tube Low Level = empty, HI Level = full at setup.| None
E31| Barcode Reader error.| None
E32| The three sets of LEDs used to distinguish Coin size have been damaged.| None
E33| Recognition Ver Error| None
E35| Normal Mode Fished. Only for THB| None
E36| Security Mode-Locked. Only for THB| None
E37| Security Mode Listed. Only for THB| None
E38| Coin Calibration fail. Only for THB| None
None| The “Inhibit” signal is transmitted by the interface.| 2 Red

Taiwan
International Currency Technologies Corporation
No.28, Ln. 15, Sec. 6, Minquan E. Rd., Neihu Dist., Taipei City 114, [email protected] (For Sales)
[email protected] (For Customer Service)
Website: www.ictgroup.com.tw

© 2013 International Currency Technologies Corporation
V. 5.0 Part Number: H6491D-R

References

Read User Manual Online (PDF format)