iCT XBA-Mini Bill Acceptor Installation Guide

June 4, 2024
ICT

iCT XBA-Mini Bill Acceptor

Introduction

Overview

The XBA-mini Bill Acceptor equips with innovative wide-angle banknote insertion technology to offer superior acceptance rate of 98% or higher. With the outstanding design, the XBA-mini has the ability to provide very high degree of immunity to strong ambient light, and the advanced optical/mechanical anti-fishing structure for better investment protection. The built-in USB port allows firmware upgrades via USB flash drive conveniently.

Features
  • Unique wide-angle banknote insertion technology
  • High immunity against strong ambient light
  • Advanced optical/mechanical anti-fishing structure
  • Firmware via USB, MDB-FTL, TTL-Serial.
  • Auto-calibration technology and multi-color optical sensors
  • Superior validation M.T.B.F 300.000 cycles
  • Strong resistance to severe weather conditions
  • Improved water draining system
  • Equipped with flip-up metal cash box

Specifications

General
Acceptance Rate 98% or greater

Note: The incomplete bills such as extremely dirty, wet, broken or wrinkled ones are excluded.
Bill Insertion| Four way acceptable
Transaction Speed| Approx. 2.5 s to stack
Interface| MDB, Pulse, ICT Protocol, JPSTD
Installation| Indoor & Outdoor

Electrical

Power Source| 12V DC±10%
24V DC±10%
34V DC±10%
24VAC±10%
---|---
Power Consumption| Standby: 0.2A, 2.4W
Operation: 1.0A, 12W
Maximum: 2.0A, 24W
Operation Environment| Operating Temperature: -15°C~60°C
Storage Temperature: -30°C~ ?0°C
Humidity: 30%~95%RH(no condensation)

Mechanical

Bill Capacity| Standard cashbox:
Approx.100 bills, 200 bills, 350 bills, 600 bills, 1000 bills.Flip-up cashbox:
Approx.100 bills, 200 bills.Extended cashbox:
Approx.400 bills, 600 bills, 1000 bills.
---|---
Weight| Approx.1.2kg~1. 7kg
(Depend on Bezel style and Bill box capacity)
Bill Accepted Width| Standard/ Extended cashbox: 62~74mm
Flip-up cashbox: 62~72mm
Bill Accepted Length| Standard/ Flip-up cashbox: 120~160mm
Extended cashbox: 120~180mm

Packing List

Main Bill Acceptor
Accessory Harnesses: Refer to 5-1

Dimension

XBA-Mini Bill Acceptor Dimension

XBA-Mini Bill Acceptor Dimension

XBA-Mini Bill Acceptor Dimension

Installation

Harness Application
Interface Used Voltage Usage Harness Page
MOB 12/24VDC Power & *Data comm. WEL-RS7P02 7
34VDC Power & *Data comm. WEL-RM006 8

24VAC
Pulse| 12/24VDC| Power & Data comm.| WEL-RV701| 9
Extension Wire| CU-R961-1| 9
24VAC| Power &
Data comm.| WEL-RV703| 10
Extension Wire| WEL-RV702| 10
ICT Protocol| 12/24VDC| Power| WEL-RV701| 9
Extension Wire| CU-R961-1| 9
Data Comm.| WEL-RV706-1 or 2-BA-RV706| 11
JPSTD| 24VDC| Power &
Data Comm.| WEL-RX7P03 BE| 12

12

USB Download| | USB Extension Wire| WEL-RX7P02-1

XBA-Mini Bill Acceptor Installation illustration

XBA-Mini Bill Acceptor Installation illustration

XBA-Mini Bill Acceptor Installation illustration

XBA-Mini Bill Acceptor Installation illustration

XBA-Mini Bill Acceptor Installation illustration

XBA-Mini Bill Acceptor Installation illustration

XBA-Mini Bill Acceptor Installation illustration

XBA-Mini Bill Acceptor Installation illustration

XBA-Mini Bill Acceptor Installation illustration

I/O Circuit

Pulse Interface.

XBA-Mini Bill Acceptor Installation illustration

XBA-Mini Bill Acceptor Installation illustration

ICT-Protocol Interface.

XBA-Mini Bill Acceptor Installation illustration

XBA-Mini Bill Acceptor Installation illustration

MDB Interface.

XBA-Mini Bill Acceptor Installation illustration

XBA-Mini Bill Acceptor Installation illustration

JPSTD Interface.

XBA-Mini Bill Acceptor Installation illustration
XBA-Mini Bill Acceptor Installation illustration
XBA-Mini Bill Acceptor Installation illustration

DIP Switch Setting

Two dip switches are located on as FIG.01 the CPU board, and as FIG.02 the sides of XBA-mini series.
XBA-Mini Bill Acceptor Maintenance illustration

Firmware Download and Upgrade

Step 1. Put the “X?Exxx.bin” file into your USB Pen Drive.

Step 2. Turn off XBA-mini, plug the USB Pen Drive into the USB connector on the XBA-mini and then turn on the XBA-mini.
XBA-Mini Bill Acceptor Installation illustration
Step 3. The LED in the rear side of bill insertion module will flash twice, then remove the USB Pen Drive from XBA-mini.
Step 4. Wait for about 30sec., Then XBA-mini will automatically reset and standby for normal operation.

Maintenance

To make sure the bill acceptor always works smoothly, please clean the internal parts regularly.

To clean the internal parts:

  1. Press the buttons on the sides of bill path and pull the unit out.
    XBA-Mini Bill Acceptor Maintenance illustration

  2. Use a soft, dry cloth or towel to clean the bill path and sensors.
    XBA-Mini Bill Acceptor Maintenance illustration

Maintenance Notice
(Any improper maintenance will result invalid warranty-)


| Recommended| Mild, non-abrasive, soap water.
DO NOT USE| Organic solvent , Alcohol, Volatility liquid.

Troubleshooting

Bezel LED Errors

LED Flashes

| Status|

Corrective Actions

---|---|---

RED

|

GREEN

 | 1| White Card Calibration| Please calibrate with ICT white calibration card.
1|  | Bill jammed.| Remove the bill box by sliding the top button and the bill path(as 7-2 FIG.01) , and then remove the jammed bill.
2|  | Disable.| Inspect the right DIP switch setting.
3|  | Recognition sensor module error.| Inspect the foreign objects on sensor or bill path and clean.
3| 1| IR error.| Inspect the foreign objects on sensor or bill path and clean.
3+2|  | Hook sensor error.| Inspect the foreign objects on security hook and clean.
4|  | Anti-string sensor error or a stringing attempt has detected.| Inspect the foreign objects on sensor or bill path and clean.
5|  | Bill box has been removed.| Replace the bill box.
6|  | Stacker error or stacker full.| Empty the bill box.
7|  | Motor error.| Inspect the foreign objects on bill path and clean.

XBA-Mini Bill Acceptor Maintenance illustration

| If the error can not be solved after corrective actions or happen again, please contact ICT for technical support.
---|---

Back LED Errors
LED Flashes Status Corrective Actions

RED
 | White Card Calibration| Please calibrate with ICT white calibration card.
 | Bill jammed.| Remove the bill box by sliding the top button and the bill path(as 7-2 FIG . 01) , and then remove the jammed bill.
2| Disable.| Inspect the right DIP switch setting.
3| Recognition sensor module error.| Inspect the foreign objects on sensor or bill path and clean.
3+1| IR error.| Inspect the foreign objects on sensor or bill path and clean.
3+2| Hook sensor error.| Inspect the foreign objects on security hook and clean.
4| Anti-string sensor error or a stringing attempt has detected.| Inspect the foreign objects on sensor or bill path and clean.
5| Bill box has been removed.| Replace the bill box.
6| Stacker error or stacker full.| Empty the bill box.
7| Motor error.| Inspect the foreign objects on bill path and clean.

XBA-Mini Bill Acceptor Maintenance illustration

| If the error can not be solved after corrective actions or happen again, please contact ICT for technical support.
---|---