iCT BS7 Bill Acceptor Recycler Installation Guide

June 5, 2024
ICT

ICT BS7 Bill Acceptor Recycler Installation Guide

Introduction

Overview

8S7 is a bill acceptor which features not only a high-security module with a bill box but also outstanding recognition, and acceptance rate up to 96% or even greater.

Features

  •  Four-way bill insertion acceptance.
  •  Numerous interfaces are available.
  •  Easily Install & Maintain.
  •  High Acceptance Rate up to 96%.

Specifications

General

  • Acceptance Rate 96% or greater
  • Note: The incomplete bills such as extremely dirty, wet, broken or wrinkled ones are excluded.
  • Bill Insertion
  • Transaction
  • Speed Interface
  • Four-way acceptance
  • Approx. 3 seconds to stack
  • Pulse, ICT
  • Protocol,
  • MOB,
  • GPT Parallel

Electrical

  • Power Source
  • Power Consumption
  • Operation Environment
  • 12V DC (11.4~12.6V DC)
  • 24V AC (21.6~26.4V AC)
  • 34V DC (20V~42.5V DC)
  • 12V DC- Standby: 0.41A, 5W Operation: 2A, 24W Maximum: 3A, 36W
  • Operation Temperature: 0° C~55° C Storage Temperature: -30° C~ 70° C Humidity: 30%~85RH

Mechanical

  • Outline Dimension
  • Bill Capacity
  • Weight
  • Refer to page.4
  • Approx. 400 bills (350-450)
  • Approx. 1.25kg

Packing List

  • Main
  • Accessory
  • Bill Acceptor
  • Harnesses: Refer to 5-1 BS? Installation Guide
  • BS? DIP Switch Setting Guide

Dimension

iCT-BS7-Bill-Acceptor-Recycler-FIG-1

Installation

Harness Application

| Power & *Data Comm.| WEL-RV701| 6
---|---|---|---
Standard| 12VDC| Extension Wire| CU-R961-1| 7
Pulse|

24VAC

| Power & *Data Comm.

Extension Wire

| WEL-RV703

WEL-RV702

|

9

MOB| 34VDC| Power & *Data Comm.| WEL-RM006| 10
| | Power| WEL-RV701| 6
ICT Protocol (RS232)|

12VDC

| Extension Wire| CU-R961-1

WEL-RV706-1

| 7
| | Data Comm.| or| 11
| | | 2-BA-RV706|
GPT Parallel| 24VAC| Power &
Data Comm.| 5R  BG-AA203L 1-XX| 12

Data Comm.: Data Communication.
RBG-AA203L 1-xx: Plug-in Box & Cables, “XX” varies from version to version .iCT-BS7-Bill-Acceptor-Recycler-FIG-2iCT-BS7
-Bill-Acceptor-Recycler-FIG-3iCT-BS7-Bill-Acceptor-Recycler-
FIG-4iCT-BS7-Bill-Acceptor-Recycler-
FIG-5iCT-BS7-Bill-Acceptor-Recycler-
FIG-6iCT-BS7-Bill-Acceptor-Recycler-
FIG-7

Circuit

Pulse InterfaceiCT-BS7-Bill-Acceptor-Recycler-FIG-9

ICT-Protocol Interface.

MDB Interface

GPT Parallel InterfaceiCT-BS7-Bill-Acceptor-Recycler-
FIG-12

DIP Switch Setting

There are two serial DIP switches which are located on the side of BS? (as FIG.01 ). According to different currencies which are used by users, DIP switch settings could be varied to fit users’ need. Besides, there’s also a serial DIP switches on CPU board inside of BS? for interface settings.(as FIG.02) Please refer to “BS? DIP Switch Setting” Guide in the package for more detail.iCT-BS7-Bill-Acceptor-Recycler-FIG-13

Software Download and Upgrade

To download and upgrade the software to BS?, the programmer (FP-004) is needed. Please contact ICT to purchase FP-004 and refer to FP-004 user guide for software download and upgrade  information. iCT-BS7-Bill-Acceptor-
Recycler-FIG-14

Maintenance

To make sure the bill acceptor always works smoothly, please clean the internal parts regularly.
To clean the internal parts:

  1.  Press the buttons on the sides of bill path unit and pull the unit out.iCT-BS7-Bill-Acceptor-Recycler-FIG-15
  2.  Use a soft, dry cloth or towel to clean the bill path and sensors.

Troubleshooting

Back LED Errors

iCT-BS7-Bill-Acceptor-Recycler-FIG-18

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ICT User Manuals

Related Manuals