FIREMAGIC E660i-0T4N 30 Inch Built-In Natural Gas Griddle User Guide
- June 3, 2024
- FIREMAGIC
Table of Contents
FIREMAGIC E660i-0T4N 30 Inch Built-In Natural Gas Griddle
DIMENSIONS IN INCHES
Access Doors
(A) Horizontal Single Access **Doors***
33914-SR (SL) Select
53914SC-R (L) Premium Flush
| 15″ X 20½”
33917-SR (SL) Select
53917SC-R (L) Premium Flush
| 18″ X 24½”
(B) Vertical Single Access Doors *****
33920-SR (SL) Select
33920-1-SR (SU* Select 53920SC-R (L) Premium Flush
53920HSC-R (L) Black Diamond
| ****
21″ X 14½”
33924-SR (SL) Select
53924SC-R (L) Premium Flush
| 25″ X 17½”
- Available with left or right door hinge
- Vertical single access door includes louvers
(C) Double Access Doors
53934SC| Premium Flush| 15″ X 30″
33930S
53930SC
| Select
Premium Flush
| 21″ X 30″
33938S| Select|
53938SC| Premium Flush| 16″ X 39″
53938HSC| Black Diamond|
Flange Overlap Dimensions/Select Doors
Flange Overlap Dimensions/ Premium Flush Doors
FOR COUNTER-TOP OVERHANG
A notch must be cut into the overhang to allow the grill face to sit flush with the front wall. Also allow clearance for control panel removal.
OUTDOOR KITCHEN CONSIDERATIONS
- Provide ventilation in island for gas vapors to escape. Allow at least four ventilation openings (two at floor level and two 16″ above floor 10 inP each) at opposing ends/sides
- Carefully consider grill size & accessories needed
- Combustible construction requires an insulating liner
- Select Natural or Propane (LP gas)
- Determine total gas consumption for supply line size
- Access is required to gas connections and shut off valve
- Plan location of propane tank away from grill and appliances
- Always refer to the installation and operating instructions of your Fire Magic grill and/or accessories for installation guidelines& safety warnings, before starting your project
- Always check all gas connections for leaks
LOCATION
Identify outdoor area where grill will be installed Determine the utilities needed (gas, water, electricity, drainage, etc.) Consider element exposure (sun, wind direction”, weather, etc) Wind blowing into or across the rear oven id vent can cause poor performance and/or dangerous overheating. Orient the gril so that the prevailing wind blows toward the front of the gni
MATERIALS
- Foundation concrete
- Base- brick, stone, stucco, concrete
- Counter-top – tile, granite, marble, concrete
Notes
- There is a hanger on three sides of each gnil. You must allow clearance for the hanger (SEE DETAIL 1),
- The control panel (face) of the grills is wider than the cutout width. This conceals the cutout space on the left & right hand sides.
- Clearance of 10″ on each side of the oven is recommended for the unrestricted operation of lid and rotisserie and at least at the rear flange for ease of maintenance and proper operation. (18″ from combustible surroundings on each side and rear is required)
- Insulating iners must be used& are available for combustible surrounds.
- The rotisserie motor on all models is located on the right side of the gnil. Optional Reverse Brackets are available to mount rotisserie motor on opposite side. ONLY units ordered with back burner option come with rotisserie kit and brackets.
BUILT-IN KEGERATOR ONLY
- Proper operation requires a floor drain within 5ft. of the ice maker.
Access Doors
( D. ). H. orizontal Single A c. ces s Doors *****
Model# Series Cutout (h x w)
23912-S| Legacy| 12½” X 18½”
23914-S| Legacy| 14½” X 20½”
23917-S| Legacy| 17½” X 24½”
Model# Series Cutout (h x w)
(E.. ). Vertical Single Acce. ss Doors *****
23918-S
|
Legacy
| 18½” X 12½”
23920-S| Legacy| 20½” X 14½”
23924-S| Legacy| 24½” X 17½”
- Doors can be flipped for reversible hinges.
(F) Double Access Doors
Model# Series Cutout (h x w)
23930-S Legacy 20½” X 30″
Pedestal Grill Dimensions
- A430s-7EAP-P6
- A430s-8EAP-P6
- C430s-RT1P-P6
Notes
- There is a hanger on three sides of the gril (SEE DETAIL 3)
- The control panel (face) of the accessories is wider than the cutout width, this conceals the cutout space on the left & right hand sides.
- Clearance of 10″ on each side, and 3″ at the rear of the oven is recommended for unrestricted operation of accessoies. (18″ from combustible surroundings on each side and rear)
- Insulating liners must be used and are available for combustible Surrounds. Double Side burner (3281), Single Side burner (3279- 1) and Drop-ln Side burner (3280) do not reauire an insıulatina.
TOP VIEW
FOR COUNTER-TOP OVERHANG
A notch must be cut into the overhang to allow the accessory face to sit flush with the front wall. Also, allow clearance for control panel removal.
Most accessory hangers measure 1″ all around The exceptions are: The Bar Caddy (1D-S0), The Beverage Butler (3835), Refreshment Centers (3596A, 33596), and Beverage Centers (1D-SSA, 1D-SSD).. these units have a hanger that measures 2″ all around.
The door frame varies in width (1″-2″ ALL AROUND) depending on the size & configuration of the door & drawer.
Flange Overlap Dimensions/ Legacy Doors
INSTALLING IN A COMBUSTIBLE ENCLOSURE
INSULATING LINER MUST BE USED WHEN INSTALLING IN A COMBUSTIBLE ISLAND
Not used on Double Side burner (3281), Single Side burner (3279-1) or Drop-In Side burner (3280)
Single and Double Side Burmers may be installed into a combustible enclosure provided there is a minimum of a 1/2″ airspace between ALL SIDES of the unit and any combustible material.
INSULATING LINER CUT-OUT DIMENSIONS (ECHELON, AURORA & CHOICE GRILLS)
INSULATING LINER CUT-OUT DIMENSIONS (LEGACY & ACCESSORIES)
To install and operate the Fire Magic outdoor gas appliance, please refer to the Installation and Operating instructions and safety precautions shipped with the appliance.
INSULATING LINER CUT-OUT DIMENSIONS (DROP-IN GRILLS)
The information provided is for reference only. Detailed instructions are supplied with the insulation liner, unique to the model selected. Read those instructions carefully and completely before starting the installation of the liner.
ECHELON PORTABLE GRILLS & GRIDDLE
AURORA/CHOICE PORTABLE GRILLS
- Measurement includes crank.
VENT HOOD SPECS & WARRANTY INFORMATION
VENT HOODS
MODELS AVAILABLE
VENT HOODS | SIZE | DUCT **COVERS*** | **SPACERS*** |
---|---|---|---|
36-VH-7 | 36″ | 36-VH-7-DC | 36-VH-7-02 |
42-VH-7 | 42″ | 42-VH-7-DC | 42-VH-7-02 |
48-VH-7 | 48″ | 48-VH-7-DC | 48-VH-7-02 |
60-VH-7 | 60″ | 60-VH-7-DC | 60-VH-7-02 |
- Duct Covers and Spacers must be used together.
SPECIFICATIONS
Fire Magic° Outdoor Grill Warranty Highlights
Lifetime Warranty
CAST STAINLESS STEEL BURNERS, CHOICE STAINLESS STEEL U-SHAPED BURNERS, DIAMOND SEAR &STAINLESS STEEL ROD COOKING GRIDS, AND STAINLESS STEEL HOUSINGS ARE WARRANTED FOR AS LONG AS YOU OWN YOUR FIRE MAGIC GRILL.
Fifteen (15) Year Warranty
BRASS VALVES, INNER LINERS, MANIFOLD ASSEMBLIES, PORCELAIN HOUSINGS (NCLUDING OVENS AND BARBECUE FACES), AND BACKBURNER ASSEMBLIES (EXCEPT IGNITION PARTS).
Ten (10) Year Warranty
- ELECTRIC GRILLS, INCLUDING STAINLESS STEEL COOKING GRIDS, AND HOUSINGS.
- BUILT-IN GRIDDLES (EXCEPT IGNITION SYSTEM) ARE WARRANTED FOR TEN YEARS.
LAVOR GRIDS, INFRARED BURNERS warranty
FLAVOR GRIDS, INFRARED BURNERS IN THE GRILL, CHARCOAL STAINLESS STEEL GRILLS AND SMOKERS (EXCEPT FOR THE CHARCOAL PAN, CHARCOAL GHID, WOOD PELLETSCREEN, THERMOMETER AND ASH THAY; WHICH ARE WARRANTED FOR ONE (1) YEAR.
Three (3) Year Warranty
SIDE BURNERS AND ALL OTHER FIRE MAGIC GRILL COMPONENTS (EXCEPT IGNITION SYSTEMS AND ELECTRICAL PARTS)
One (1) Year Warranty
IGNITION SYSTEMS (EXCEPT BATTERIES), ELECTRONIC COMPONENTS (INCLUDING LIGHTS AND THERMOMETERS), AND GRILL ACCESSORIES.
FIRE MAGIC RESERVES THE RIGHT TO AMEND PRODUCT SPECIFICATIONS WITHOUT PRIOR NOTICE
The information provided in this document is for reference purposes only. Detailed instructions & specifications unique to the product purchased can be found in the Owner’s Manual. Read those instructions carefully and completely before attempting installation of any Fire Magic Outdoor Grill product.
R.H. Peterson Co.
- 14724 Proctor Ave, City of Industry, CA 91746
- www.firemagicgrills.com
- Ph. 800-332-3973
- Fax: 626-369-5979
Rev. 1-2007101100 L-C1-01320