APC EPDU1116S PDU Switched Rack Power Distribution Unit Installation Guide
- June 3, 2024
- APC
Table of Contents
- APC EPDU1116S PDU Switched Rack Power Distribution Unit
- OVERVIEW
- Safety
- Installation
- Display Interface
- Specifications
- Life Support Policy
- Examples of life-support devices
- Radio frequency interference
- Factory Warranty
- Exclusions
- Warranty claims
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
APC EPDU1116S PDU Switched Rack Power Distribution Unit
Worldwide Customer Support
Customer support for this product is available at
www.apc.com
© 2020 APC by Schneider Electric. APC and NetShelter are trademarks owned by
Schneider Electric SE. All other trademarks are property of their respective
owners.
OVERVIEW
This sheet provides installation information for your Easy PDU. Read the instructions carefully.
Receiving
Inspect the package and contents for shipping damage. Make sure all parts were
sent. Immediately report any shipping damage to the shipping agent. Report
missing contents, product damage, or other problems with the product to APC by
Schneider Electric or your APC by Schneider Electric reseller.
Material recycling
The shipping materials are recyclable. Please save them for later use, or
dispose of them appropriately.
Safety
Read the following information before installing or operating your APC by Schneider Electric Rack Power Distribution Unit (PDU).
DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
- The Rack PDU is intended to be installed and operated by a skilled person in a controlled location.
- Do not operate the Rack PDU with the covers removed.
- This Rack PDU is intended for indoor use only.
- Do not install this Rack PDU where excessive moisture or heat is present.
- Never install any wiring, equipment, or Rack PDUs during a lightning storm.
- Plug this Rack PDU into a grounded power outlet only. The power outlet must be connected to appropriate branch circuit/mains protection (fuse or circuit breaker). Connection to any other type of power outlet may result in a shock hazard.
- Do not use extension cords or adapters with this Rack PDU.
- If a socket-outlet is not accessible to the equipment, a socket-outlet shall be installed.
- Do not work alone under hazardous conditions.
- Check that the power cord, plug, and socket are in good condition.
- Disconnect the Rack PDU from the power outlet before you install or connect equipment to reduce the risk of electric shock when you cannot verify grounding. Reconnect the Rack PDU to the power outlet only after you make all connections.
- Do not handle any kind of metallic connector before the power has been removed.
- Use one hand, whenever possible, to connect or disconnect signal cables to avoid a possible shock from touching two surfaces with different grounds.
- This unit does not have any user-serviceable parts. Repairs are to be performed only by factory-trained service personnel.
Failure to follow these instructions will result in death or serious injury.
WARNING
FIRE HAZARD
- This equipment should be connected to a single-outlet dedicated circuit protected by a circuit breaker or fuse with the same current rating as the Rack PDU.
- The plug or inlet serves as the disconnect for the Rack PDU. Make sure the utility power outlet for the Rack PDU will be close to the Rack PDU and readily accessible.
Failure to follow these instructions can result in death or serious injury.
Installation
Option 1 – Vertical Installation with Brackets
-
Install the two (2) brackets to the Rack PDU with the screws provided
-
Install the PDU to the rack with the provided four (4) M5 x10 mm self tapping screws
Option 2 – Toolless Mounting Pegs
The mounting pegs of the Rack PDU are installed at the factory. Slide both
mounting pegs into the holes located in the channel in the rear panel of the
rack. Snap the Rack PDU into place by pushing it downward until it locks into
position.
NOTE: When installing the Rack PDU, ensure that the power cord plug is
accessible and that it is connected to a grounded outlet.
Display Interface
Item | Function | Description |
---|---|---|
| LCD Display | View functional data |
| Run Indicator LED | Indicates the status when the power is on |
| Reset Button | Press and hold for 4 seconds to reset to the default settings |
| Up Function Button | Scroll for function status, Alarm shutoff |
| Down Function Button | Scroll for function status, hold for Alarm shutoff |
(Press and hold for 10 seconds to reboot)
| Temp/Humidity Port| Temp/Humidity Sensor connection port
| Out Port| RS485 port sharing connection
| In Port| RS485 port sharing connection
| Network Port| Connect the Rack PDU to your network
Use the up and down function buttons to view information on the LCD display.
To configure the network settings and access the Rack PDU
Connect the network cable to the Network port and apply power to the unit.
When you hear a “Beep” sound and the Status LED for the network connection
is flashing green, press the Down function button until the IP address
appears.
To access the Rack PDU software interface, enter the IP address in your
browser address field. You will be prompted for a username and password. Enter
the default “apc” for each. See the User Guide for this device online at
www.apc.com for more detailed information.
Specifications
EPDU1116S | EPDU1132S |
---|
Electrical
Nominal Input Voltage| 200 – 240 VAC 1 PHASE
Maximum Input Current (Phase)| 16A| 32A
Input Frequency| 50/60Hz
Input Connection| IEC309 16A 2P +E| IEC309 32A 2P +E
Output Voltage| 200 – 240 VAC
|
Twenty (20) C13
Max. output current 10A
| Bank 1:
Ten (10) C13
Max. output current 10A Two (2) C19
Max. output current 16A
Output Connections| |
| Four (4) C19
Max. output current 16A
| Bank 2:
Ten (10) C13
Max. output current 10A Two (2) C19
Max. output current 16A
Circuit Breakers
|
None
| Two (2) 16A 1-pole hydraulic-magnetic circuit breakers
Physical
Dimensions (H x W x D)| 1738 x 55 x 62 mm
(68.43 x 2.16 x 2.44 in)
Input power cord length| 3 m (9.8 ft)
Shipping dimensions (H x W x D)| 1950 x 160 x 110 mm
(76.77 x 6.30 x 4.33 in)
Weight/Shipping weight EPDU1116S EPDU1132S|
7.3 kg (16.09 lb)/8.5 kg (18.74 lb)
7.9 kg (17.41 lb)/9.0 kg (19.84 lb)
Environmental
Maximum elevation (above MSL)| 0–3000 m (0–10,000 ft) /
Operating/Storage| 0–15000 m (0–50,000 ft)
Temperature: Operating/Storage| –5 to 45°C (23 to 113°F)/
–25 to 65°C (–13 to 149°F)
Humidity: Operating/Storage| 5–95% RH, non-condensing
Compliance
EMC verification| CE EN55035, EN55032, EN55024
Safety verification| CE, TUV, EN/IEC62368-1
CE EU Contact Address| Schneider Electric, 35 rue Joseph Monier 92500 Rueil
Malmaison France
Environmental| RoHS & Reach
Life Support Policy
General policy
APC by Schneider Electric does not recommend the use of any of its products in
the following situations:
- In life-support applications where failure or malfunction of the APC by Schneider Electric product can be reasonably expected to cause failure of the life-support device or to affect significantly its safety or effectiveness.
- In direct patient care.
APC by Schneider Electric will not knowingly sell its products for use in such applications unless it receives in writing assurances satisfactory to APC by Schneider Electric that (a) the risks of injury or damage have been minimized, (b) the customer assumes all such risks, and (c) the liability of APC by Schneider Electric is adequately protected under the circumstances.
Examples of life-support devices
The term life-support device includes but is not limited to neonatal oxygen
analyzers, nerve stimulators (whether used for anesthesia, pain relief, or
other purposes), autotransfusion devices, blood pumps, defibrillators,
arrhythmia detectors and alarms, pacemakers, hemodialysis systems, peritoneal
dialysis systems, neonatal ventilator incubators, ventilators (for adults and
infants), anesthesia ventilators, infusion pumps, and any other devices
designated as “critical” by the U.S. FDA.
Hospital-grade wiring devices and leakage current protection may be ordered as
options on many APC by Schneider Electric UPS systems. APC by Schneider
Electric does not claim that units with these modifications are certified or
listed as hospital-grade APC by Schneider Electric or any other organization.
Therefore these units do not meet the requirements for use in direct patient
care.
Radio frequency interference
Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
Factory Warranty
This warranty applies only to the products you purchase for your use in accordance with this manual.
Terms of warranty
APC by Schneider Electric warrants its products to be free from defects in
materials and workmanship for a period of one year from the date of purchase.
APC by Schneider Electric will repair or replace defective products covered by
this warranty. This warranty does not apply to equipment that has been damaged
by accident, negligence or misapplication or has been altered or modified in
any way. Repair or replacement of a defective product or part thereof does not
extend the original warranty period. Any parts furnished under this warranty
may be new or factory-remanufactured.
Non-transferable warranty
This warranty extends only to the original purchaser who must have properly
registered the product. The product may be registered at the APC by Schneider
Electric website, www.apc.com.
Exclusions
APC by Schneider Electric shall not be liable under the warranty if its testing and examination disclose that the alleged defect in the product does not exist or was caused by end user’s or any third person’s misuse, negligence, improper installation or testing. Further, APC by Schneider Electric shall not be liable under the warranty for unauthorized attempts to repair or modify wrong or inadequate electrical voltage or connection, inappropriate on-site operation conditions, corrosive atmosphere, repair, installation, exposure to the elements, Acts of God, fire, theft, or installation contrary to APC by Schneider Electric recommendations or specifications or in any event if the APC by Schneider Electric serial number has been altered, defaced, or removed, or any other cause beyond the range of the intended use.
THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, BY OPERATION OF LAW OR OTHERWISE, OF PRODUCTS SOLD, SERVICED OR FURNISHED UNDER THIS AGREEMENT OR IN CONNECTION HEREWITH. APC BY SCHNEIDER ELECTRIC DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY, SATISFACTION AND FITNESS FOR A PARTICULAR PURPOSE. APC BY SCHNEIDER ELECTRIC EXPRESS WARRANTIES WILL NOT BE ENLARGED, DIMINISHED, OR AFFECTED BY AND NO OBLIGATION OR LIABILITY WILL ARISE OUT OF, APC BY SCHNEIDER ELECTRIC RENDERING OF TECHNICAL OR OTHER ADVICE OR SERVICE IN CONNECTION WITH THE PRODUCTS. THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES AND REMEDIES. THE WARRANTIES SET FORTH ABOVE CONSTITUTE APC BY SCHNEIDER ELECTRIC’S SOLE LIABILITY AND PURCHASER’S EXCLUSIVE REMEDY FOR ANY BREACH OF SUCH WARRANTIES. WARRANTIES EXTEND ONLY TO PURCHASER AND ARE NOT EXTENDED TO ANY THIRD PARTIES.
IN NO EVENT SHALL APC BY SCHNEIDER ELECTRIC, ITS OFFICERS, DIRECTORS, AFFILIATES OR EMPLOYEES BE LIABLE FOR ANY FORM OF INDIRECT, SPECIAL, CONSEQUENTIAL OR PUNITIVE DAMAGES, ARISING OUT OF THE USE, SERVICE OR INSTALLATION, OF THE PRODUCTS, WHETHER SUCH DAMAGES ARISE IN CONTRACT OR TORT, IRRESPECTIVE OF FAULT, NEGLIGENCE OR STRICT LIABILITY OR WHETHER APC BY SCHNEIDER ELECTRIC HAS BEEN ADVISED IN ADVANCE OF THE POSSIBILITY OF SUCH DAMAGES. SPECIFICALLY, APC BY SCHNEIDER ELECTRIC IS NOT LIABLE FOR ANY COSTS, SUCH AS LOST PROFITS OR REVENUE, LOSS OF EQUIPMENT, LOSS OF USE OF EQUIPMENT, LOSS OF SOFTWARE, LOSS OF DATA, COSTS OF SUBSTITUENTS, CLAIMS BY THIRD PARTIES, OR OTHERWISE.
NO SALESMAN, EMPLOYEE OR AGENT OF APC BY SCHNEIDER ELECTRIC IS AUTHORIZED TO ADD TO OR VARY THE TERMS OF THIS WARRANTY. WARRANTY TERMS MAY BE MODIFIED, IF AT ALL, ONLY IN WRITING SIGNED BY AN APC BY SCHNEIDER ELECTRIC OFFICER AND LEGAL DEPARTMENT.
Warranty claims
Customers with warranty claims issues may access the APC by Schneider Electric customer support network through the Support page of the APC by Schneider Electric website, www.apc.com/support. Select your country from the country selection pull-down menu at the top of the Web page. Select the Support tab to obtain contact information for customer support in your region.
References
- APC, a flagship brand of Schneider Electric - APC USA
- APC, a flagship brand of Schneider Electric - APC USA
- APC, a flagship brand of Schneider Electric - APC USA
- APC, a flagship brand of Schneider Electric - APC USA
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>