APC PHONIC 4 GSM Audio Intercom Door Bell User Manual
- June 3, 2024
- APC
Table of Contents
GSM Audio Intercom Door Bell
User Manual
PHONIC 4 GSM Audio Intercom Door Bell
Caution!
Please read this manual carefully before installing the GSM, basic electronic
knowledge is required.
Product Details
The APC Phonic 4 is a powerful remote controller with intercom which can be
used for controlling gates, authorized door access, switching on/off remote
equipment, etc. his device can be used remotely with 4G mobile communications
system, which allows for two-way interaction and faster unlocking with a call
or text message from your mobile phone.
Features
- Can be operated from anywhere with no limits on distance.
- Supports two-way interaction.
- Can be used for multiple applications such as gates, access doors, shutters, etc
- Most secure system as it has caller ID identification and allows for two-way interaction between residents and visitors.
- No need to provide keys or remote controls to different users.
- All settings are performed by SMS commands.
- Up to 4 authorized phone numbers for providing access control / call can be stored on the device.
- SMS confirmation is provided to the owner or authorized users regarding the status of the commands given.
- Can add or remove users by SMS commands.
- The unlock time, mic volume and speaker volume is programmable.
Specifications
Working Voltage | 12-15VDC |
---|---|
Working Current | ~130mA |
Standby Current | ~45mA |
Working Temperature | -20~-65C |
Dimensions | L13.6cmB7.8cmH4.5cm |
Dimensions
Standard Packing List
- Gate Opener Unit
- Antenna
- Back Hood
- Screws and Tool
- User Manual
Safety Directions
Interference
All wireless equipment might interfere with the network signals of the Gate
Opener and influence its performance.
Avoid use at Fuel Station
Do not use APC Phonic4 at a fuel station.
DO NOT USE at Blasting Sites
Please follow relevant restrictive regulations. Avoid using the device in
blasting sites.
Reasonable Use
Please install the product in a suitable location as described in the product
documentation.
Typical Wiring Connections
• APC-LOGICO 24 • APC-LOGICO 24 Proteous Series Swing Gate System
• APC-CBSW12 • APC-CBSW24 Swing Gate System
• APC-P450 Proteous 450 Sprint • APC-P500 Proteous 500
• APC-SG802-AC Typhoon •APC-SG1600-AC Tsunami •APC-SG3000-AC Tornado
Connection to Electric Striker (Fail Safe Type)
Note: Power supply voltage must be suitable according to the electric
strikers voltage and amperage requirements and must be within the keyapds
working parameter of 12V.
Connection to PS-L3S Lock Control System
Gate Automation Systems | Electric Striker |
---|
Note: Power supply voltage must be 12-15V DC. Gate system
accessories output can power the device in most situations
with/without a power converter (24v to 12v power convertor
available from Automotion Plus).| Note: Power supply voltage must be
12-15V DC. Gate system
accessories output can power the device in most situations
with/without a power converter.
Installations and Command Settings
Installation: Open the back cover and insert your preactivated SIM Card.
Connect the power and the unit will start searching the network signal for
35seconds. If the signal is weak, the signal will search for a longer time. If
the signal couldn’t be icked up under 1 minute, then the system will search
for one signal each minute, until there is a successful connection.
Hardware Factory Reset: Press and hold the S1 button for over 5 seconds,
the device will restart, and it will restore to factory administrator
password.
Note: This operation will reset the administrator password to default
1234 and the other parameters will be changed.
Note: Maximum storage of four phone numbers on the device (1
administrator + 3 users phone numbers)
SMS Commands for System Setup
-
Set admin phone number:
1234#00*#334455 (1234 is the default admin password)
Operation success reply message: Set manager success! -
Modify admin password:
1234#PWD#9898# (9898 is the new admin password)
Operation success reply message: OK! -
Set user phone number 1:
1234#01*#XXXXXXXXXX (XXXXXXXXXX is the user phone number 1)
Operation success reply message: Set first number success!
Note: Only admin can add user phone numbers. -
Set user phone number 2:
1234#02*#XXXXXXXXXX (XXXXXXXXXX is the user phone number 2)
Operation success reply message: Set second number success!
Note: Only admin can add user phone numbers. -
Set user phone number 3:
1234#03*#XXXXXXXXXX (XXXXXXXXXX is the user phone number 3)
Operation success reply message: Set third number success!
Note: Only admin can add user phone numbers. -
Unlock operation:
1234#04*#
Operation success reply message: OK! -
Check Signal Strength:
1234#08*#
Operation success reply message will be about the signal strength between the range 1-31 (The bigger the number, the better the signal) -
Set unlock time:
1234#09*#TT (TT is the two numbers for time(s) between 01-99)
Operation success reply message: Set the lock delay success!
Note: Only admin can set the unlock time. -
Set Mic Volume:
1234#MIC#A# (A is the Mic volume level between 1-8)
Operation success reply message: OK!
Note: Only admin can set the volume of the mic. The minimum volume level (1) is not mute. -
Set Speaker Volume:
1234#AP*#A (A is the Speaker volume level between 1-8)
Operation success reply message: OK!
Note: Only admin can set the volume of the speaker. The minimum volume level (1) is not mute. -
Reset to default settings:
1234#REST#
Operation success reply message: OK!
Note: Only admin can reset to factory settings.
NOTICE: Reply message for WRONG operation
- Admin password: Wrong password!
- Invalid SMS: Invalid message!
- No permission SMS: Do not have permission!1. Set admin phone number:
Calling Operation
- Calling: Press the doorbell button and the device will call the resident phone number, if no answer in 30seconds it will call the next number automatically in a sequential order. If the user phone numbers are not set, a call error prompt will be heard. The sequential order: admin phone number-> 1st user -> 2nd user -> 3rd user.
- To be called: The phone numbers saved on the device will unlock automatically. If not saved, the device will hang up the call automatically.
- Unlock: While talking press * button to unlock.
Note: Maximum talking time is one minute.
Important information
- Please read the User Manual carefully before you install and control the device.
- Have a secure connection to the main power supply.
Maintenance
- In case of failure, please contact Automotion Plus.
- If the APC Phonic4 is not able to contact the cell phone and the signal indicator is not on, make sure the antenna is properly connected, and it doesn’t have any metal shielding.
- If the APC Phonic4 is not able to contact the cell phone and the call key has a key sound, confirm whether the SIM card is pre-activated and that is inserted in properly.
- If the device works but fails to respond to SMS texts, switch the power off and on again after one minute then allow a few minutes to initialize then test again. Also check if the settings are correct and the signal strength is in the acceptable range.
Warranty
- The device is warranted to be free of detects in material and workmanship for one year from the date of purchase.
- This warranty does not extend to any defect, malfunction or failure caused by abuse or misuse.
APC WARRANTY
APC warrants the original purchasers or the APC system for a period of twelve
months from the date of purchase (not installation), the product shall be free
of defects in materials and workmanship under normal use.
During the warranty period, APC shall, as its option, repair or replace any
defective product upon return of the product to its factory, at no charge for
labour and materials.
Any replacement and/or repaired parts are warranted for the remainder of the
original warranty, The original owner must promptly notify APC in writing that
there is defect n material or workmanship, such written notice must be
received in all events prior to expiration of the warranty.
International Warranty
APC shall not be responsible for any freight fees, taxes or customs fees.
Warranty Procedure
To obtain service under this warranty, AND AFTER CONTACTING APC, please return
the item(s) in question to the point of purchase.
All authorized distributors and dealers have a warranty program, anyone
returning goods to APC must first obtain an authorization number. APC will not
accept any shipment for which prior authorization has not been used.
Conditions to Void Warranty
This warranty applies only to defects in pairs and workmanship relating to
normal use. It does not cover:
– Damage incurred in shipping or handling
– Damage caused by disaster such as fire, flood, wind, earthquake or lightning
– Damage due to causes beyond the control of APC such as excessive voltage,
mechanical shock or water damage
– Damage caused by unauthorized attachment, alterations, modifications, or
foreign objects.
– Damage caused by peripherals (unless such peripherals were supplied by APC)
– Defects caused by failure to provide a suitable installation environment for
the products
– Damage caused by usage of the products for purpose other than those for
which it was designed.
– Damage from improper maintenance
– Damage arising out of any other abuse, mishandling, and improper application
of the products.
Under no circumstances shall APC be liable for any special, incidental, or
consequential damages based upon breach of warranty, breach of contract,
negligence, strict liability, r any other legal theory. Such damages include,
loss of profits, loss of the product or any associated equipment, cost of
capital, cost of substitute or replacement equipment, facilities or services,
down time, purchaser’s time, the claims of third parties, including customers,
andinjury to property.
Disclaimer of Warranties
This warranty contains the entire warranty and shall be in lieu of any and all
other warranties, whether expressed or implied (including all implied
warranties of erchantability r fitness for a particular purpose). And of all
other obligations or purporting to act on its behalf to modify or to change
this warranty, nor to assume for it any otherwarranty r liability concerning
this product.
Out of Warranty Repairs
APC will at its option repair or replace out-of-warranty products which are
returned to its factory according to the following conditions. Anyone
returning goods to APC ust rst obtain an authorization number. APC will not
accept any shipment whatsoever for which prior authorization has not been
obtained. Products which APC determines o be repairable will be repaired and
returned. A set fee which APC has been predetermined and which may be revised
from time to time will be charged for each nit repaired. Products which APC
determines not repairable will be replaced by the nearest equivalent product
available at that time. The current market price for the replacement product
will be charged for each replacement unit.
Read User Manual Online (PDF format)