LENA LIGHTING UV-C 144W Sterilon Air Light User Manual
- June 3, 2024
- LENA LIGHTING
Table of Contents
UV-C 144W Sterilon Air Light
User Manual
UV-C
STERILON AIR LIGHT 72W / 144W
IMPORTANT INSTRUCTIONS FOR SAFE USE
WARNING BEFORE USING UV-C STERILON AIR LIGHT FOR THE FIRST TIME, READ THE
USER MANUAL AND FOLLOW THE INSTRUCTIONS.
FLOW DISINFECTION
UVC AIR LIGHT luminaires use ultraviolet light, destroy the DNA or RNA of all
microorganisms that will be exposed and remove viruses, bacteria and fungi
from the air. Covered UVC light does not reach the outside of the lamp.
Thanks to stimulated circulation, the air passes through luminaire interior,
where it is exposed to the light and cleaned, and then pushed outside. UV-C
STERILON AIR LIGHT luminaires may work in the presence of people.
Exposure method:
-
Place the lamp in a disinfected room, if possible in a central place, to increase the eectiveness of disinfection. Remember that the disinfection eciency in a given place decreases as the distance from the lamp increases.
-
Do not cover the luminaire fan, do not place any objects on the luminaire. In order not to disturb circulation, leave an empty space and do not put any objects within 1m of the luminaire fan.
-
There may be people in the room. They can move freely and do not need protective clothing.
-
Do not open the luminaire covers during its operation.
Secure the luminaire against uncontrolled opening by other people. 2 -
Do not use in rooms smaller than 1 m
-
The smell emitted by the UV-C STERILON AIR LIGHT is a technical fragrance. It can last for approximately 60 hours of device use. This smell does not pose a threat to the users of the device.
-
A small amount of visible blue light – which is a reflected light, does not contain UV-C radiation and is safe for humans.
Disinfection eciency
- The AIR LIGHT is 110 m /h (72W); 160 m /h (144W)
- The maximum volume (cubature) of the disinfected room: 75 m (72W); 120 m /h (144W) 33
Maintenance and filter replacement
UVC – Sterilon AIR LIGHT luminaires are standard equipped with PPI30 foam
filters.
This filter should be cleaned under running water or replaced after every 80
hours of luminaire operation. The filter should be removed from the push-in
(click-on) housing on the fan, replaced and the housing pressed back on. The
filter should be replaced with a new one each time after 1000 hours of
operation of the device.
Operational safety
The UV-C light emitted by the lamp is highly harmful to humans and other
living organisms, damages eyesight, skin and cell DNA.
UV-C light degrades the DNA and RNA code in the cells of living organisms.
Damage to the luminaire will not aect your health while maintaining basic
precautions. If the fluorescent lamps break, ventilate the room for 30 minutes
and remove the contaminated parts, preferably with gloves. Place them in a
sealed plastic bag and take to a local waste disposal facility for recycling.
Do not use a vacuum cleaner to remove damaged parts.
3C CHANGING UV-C TUBES
3D CHANGING UV-C TUBES / OPTION: RESET TIME COUNTER
To reset the time counter, shorten the PE cable and screw for at least 2
seconds as it shows at the picture.
You need to use some of your spare cable to make this connection.
Technical Data:
2x PL-L 36W, 220-240V, 50-60Hz
4x PL-L 36W, 220-240V, 50-60Hz
Cable 3m, 3×0,75mm
Protection class I
With UNI-SCHUCKO / UK plug No protection against explosion.
Covered UVC light does not reach the outside of the lamp. Thanks to stimulated circulation, the air passes through luminaire interior, where it is exposed to the light and cleaned, and then pushed outside. UV-C STERILON AIR LIGHT luminaires may work in the presence of people.
UV-C STERILON AIR LIGHT luminaires may work in the presence of people.