LINCOLN ELECTRIC K14203-1 RC7 Advanced User Manual
- June 3, 2024
- LINCOLN ELECTRIC
Table of Contents
- LINCOLN ELECTRIC K14203-1 RC7 Advanced
- Technical Specifications
- Electromagnetic Compatibility (EMC)
- Safety
- Introduction
- Installation and Operator Instructions
- Controls and Operational Features
- Maintenance
- Customer Assistance Policy
- WEEE
- Spare Parts
- REACH
- Accessories
- Connection configuration
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
LINCOLN ELECTRIC K14203-1 RC7 Advanced
THANK YOU! For choosing the QUALITY of the Lincoln Electric products.
- Please check packaging and equipment for damage. Claims for material damaged in shipment must be notified immediately to the dealer.
- For ease of use, please enter your product identification data in the table below. Model Name, Code & Serial Number can be found on the machine rating plate.
Model Name:
……………………………………………….…………………………………………………………………………………………..
Code & Serial number:
…………………………………………………….……………..
Date & Where Purchased:
…………………………………………………….……………..
Technical Specifications
NAME | INDEX |
---|---|
RC7 ADVANCED | K14203-1 |
INPUT
Input Voltage U1| EMC Class
40Vdc| A
DIMENSION
Weight| Height| Width| Length
2,2 kg| 250,7 mm| 64 mm| 244 mm
OTHERS
Protection Rating
IP23
Operating Temperature| Storage Temperature
from -10°C to +40°C| from -25°C to 55°C
Electromagnetic Compatibility (EMC)
This machine has been designed in accordance with all relevant directives and
standards. However, it may still generate electromagnetic disturbances that
can affect other systems like telecommunications (telephone, radio, and
television) or other safety systems. These disturbances can cause safety
problems in the affected systems. Read and understand this section to
eliminate or reduce the amount of electromagnetic disturbance generated by
this machine.
WARNING: This machine has been designed to operate in an industrial area.
To operate in a domestic area it is necessary to observe particular
precautions to eliminate possible electromagnetic disturbances. The operator
must install and operate this equipment as described in this manual. If any
electromagnetic disturbances are detected the operator must put in place
corrective actions to eliminate these disturbances, if necessary with
assistance from Lincoln Electric.
Before installing the machine, the operator must check the work area for any
devices that may malfunction because of electromagnetic disturbances. Consider
the following.
- Input and output cables, control cables, and telephone cables that are in or adjacent to the work area and the machine.
- Radio and/or television transmitters and receivers. Computers or computer controlled equipment.
- Safety and control equipment for industrial processes. Equipment for calibration and measurement.
- Personal medical devices like pacemakers and hearing aids.
- Check the electromagnetic immunity for equipment operating in or near the work area. The operator must be sure that all equipment in the area is compatible. This may require additional protection measures.
- The dimensions of the work area to consider will depend on the construction of the area and other activities that are taking place.
Consider the following guidelines to reduce electromagnetic emissions from the machine.
- Connect the machine to the input supply according to this manual. If disturbances occur if may be necessary to take additional precautions such as filtering the input supply.
- The output cables should be as short as possible and positioned together as close as possible to each other. If possible connect the work piece to ground in order to reduce the electromagnetic emissions. The operator must check that connecting the work piece to ground does not cause problems or unsafe operating conditions for personnel and equipment.
- Shielding of cables in the work area can reduce electromagnetic emissions. This may be necessary for special applications.
WARNING
EMC classification of this product is class A in accordance with
electromagnetic compatibility standard EN 60974-10 which means that the
product is designed to be used in an industrial environment only.
WARNING
The Class A equipment is not intended for use in residential locations where
the electrical power is provided by the public low-voltage supply system.
There may be potential difficulties in ensuring electromagnetic compatibility
in those locations, due to conducted as well as radiated disturbances.
Safety
WARNING
This equipment have to be used by qualified personnel. Be sure that all
installation, operation, maintenance and repair procedures are performed only
by qualified person. Read and understand this manual before operating this
equipment. Failure to follow the instructions in this manual could cause
serious personal injury, loss of life, or equipment damage. Read and
understand the following explanations of the warning symbols. Lincoln Electric
is not responsible for damages caused by improper installation, improper care
or abnormal operation.
| WARNING : This symbol indicates that instructions must be followed to
avoid serious personal injury, loss of life, or equipment damage. Protect
yourself and others from possible serious injury or death.
---|---
| READ AND UNDERSTAND INSTRUCTIONS: Read and understand this manual
before operating this equipment. Arc welding can be hazardous. Failure to
follow the instructions in this manual could cause serious personal injury,
loss of life, or equipment damage.
| ELECTRIC SHOCK CAN KILL: Welding equipment generates high voltages. Do
not touch the electrode, work clamp, or connected work pieces when this
equipment is turned on. Insulate yourself from the electrode, work clamp, and
connected work pieces.
| ELECTRICALLY POWERED EQUIPMENT : Turn off the input power using the
disconnect switch at the fuse box before working on this equipment. Ground
this equipment in accordance with local electrical regulations.
| ELECTRICALLY POWERED EQUIPMENT : Regularly inspect the input,
electrode, and work clamp cables. If any insulation damage exists replace the
cable immediately. Do not place the electrode holder directly on the welding
table or any other surface in contact with the work clamp to avoid the risk of
accidental arc ignition.
| ELECTROMAGNETIC FIELD MAY BE DANGEROUS : Electric current flowing
through any conductor creates electromagnetic field (EMF). EMF fields may
interfere with some pacemakers, and welders having a pacemaker shall consult
their physician before operating this equipment.
| CE COMPLIANCE: This equipment complies with the European Community
Directives.
| ARTIFICIAL OPTICAL RADIATION: According with the requirements in
2006/25/EC Directive and EN 12198 Standard, the equipment is a category 2. It
makes mandatory the adoption of Personal Protective Equipment (PPE) having
filter with a protection degree up to a maximum of 15, as required by EN169
Standard.
| FUMES AND GASES CAN BE DANGEROUS: Welding may produce fumes and gases
hazardous to health. Avoid breathing these fumes and gases. To avoid these
dangers the operator must use enough ventilation or exhaust to keep fumes and
gases away from the breathing zone.
| ARC RAYS CAN BURN: Use a shield with the proper filter and cover plates
to protect your eyes from sparks and the rays of the arc when welding or
observing. To protect the skin, use suitable clothing made of durable,
fireproof material. Protect other nearby personnel with suitable, non-
flammable screening and warn them not to watch the arc nor expose themselves
to the arc.
| WELDING SPARKS CAN CAUSE FIRE OR EXPLOSION : Remove fire hazards from
the welding area and have a fire extinguisher easily accessible. Welding
sparks and hot materials from the welding process can easily go through small
cracks and openings to adjacent areas. Do not weld on any tanks, drums,
containers, or material until the proper steps have been taken to insure that
no flammable or toxic vapors will be present. Never use this equipment when
flammable gases, vapors or flammable liquids are present.
---|---
| WELDED MATERIALS CAN BURN : Welding generates a large amount of heat.
Hot surfaces and materials in work area can cause serious burns. Use gloves
and pliers when touching or moving materials in the work area.
| CYLINDER MAY EXPLODE IF DAMAGED: Use only certificate, compressed gas
cylinders containing the correct shielding gas for the process used and
properly operating regulators designed for the gas and pressure used. Always
keep cylinders in an upright position securely chained to a fixed support. Do
not move or transport gas cylinders with the protection cap removed. Do not
allow the electrode, electrode holder, work clamp or any other electrically
live part to touch a gas cylinder. Gas cylinders must be located away from
areas where they may be subjected to physical damage or the welding process
including sparks and heat sources.
| MOVING PARTS ARE DANGEROUS : There are moving mechanical parts in this
machine, which can cause serious injury. Keep your hands, body and clothing
away from those parts during machine starting, operating and servicing.
| SAFETY MARK: This equipment is suitable for supplying power for welding
operations carried out in an environment with increased risk of electric
shock.
Introduction
- RC7 Advanced is a device for remote control of the power source to which it is connected. It has been designed with strict requirements in mind to ensure comfortable operation in a variety of environmental conditions (see Transport, Carrying and Work Position Subchapter).
- RC7 Advanced panel can be connected both to the wire feeder and directly to the power source. The full list of possible configurations is provided in the Connection Configuration Chapter.
Installation and Operator Instructions
Read this entire section before installation or operating the machine.
Exploitation conditions
This machine can operate in harsh environments. However, it is important to use the following simple preventive measures that will ensure its long life and reliable operation:
- Do not place or operate this machine on a surface with an incline higher than 15° from horizontal.
- Do not use this machine for pipe thawing.
- This machine must be located where there is free circulation of clean air without restrictions for air movement. Do not cover the machine with paper, cloth or rags when switched on.
- Dirt and dust that can be drawn into the machine should be kept away from the item.
- This machine has a protection rating of IP23. Keep it dry when possible and do not place it on a wet ground or in puddles.
- Locate the machine away from a radio controlled machinery. Normal operation may adversely affect the operation of a nearby radio controlled machinery, which may result in injury or equipment damage. Read the section on electromagnetic compatibility in this manual.
- Do not operate in areas with an ambient temperature greater than 40°C.
Input Supply Connection
RC7 Advanced control panel is powered by a voltage of 40Vdc and its permissible value is given in the “Technical Specifications” Chapter.
Controls and Operational Features
- U7 User Interface: See User Manual “User Interface Advanced” IM3170.
- Left Control with Active Button: Sets the value in the lower left corner of the display. Cancel selection. Return to the previous menu.
- Right Control with Active Button: Sets the value in the lower right corner of the display. Confirmation of changes.
- Button: It enables return to main menu.
- USB Port: For connecting the USB memory and software updates.
- Control cable (5m): 12-pin connection is for connection to the welding source.
After connecting the remote control in accordance with the selected connection
diagram (see chapter Connection Configuration), RC 7 advanced is ready for
operation.
If the error message 0018 appears on the screen, please follow the steps
below:
- Press the Left Control [2] to reset the error and access parameter P.95
- Press the Right Control [3]
- Use the Right Control [3] to select the Parallel parameter
- Confirm the selection by pressing the Right Control [3]
Detailed operation of the RC7 advanced remote control can be found in the Advanced (U7) IM3170 user manual.
Transport, carrying and work position
RC7 advanced is adapted to manual transport, additionally it has elements [7] for securing the power cord during transport. RC7 advanced has been designed to provide the operator with the ability to work in various configurations:
-
Bracket [8], which is used to support the device on a flat surface, e.g. a welding table
-
Rubber feet with a magnet [9], which are used to attach the device to metal elements, e.g. to the front panel of the power source
-
Bracket [10], which is used to suspend the RC device WARNING: Falling equipment can cause injury and damage to unit.
Maintenance
WARNING
For any repair operations, modifications or maintenances, it is recommended to
contact the nearest Technical Service Center or Lincoln Electric. Repairs and
modifications performed by unauthorized service or personnel will cause the
lost of the manufacturer’s warranty
Any noticeable damage should be reported immediately and repaired.
Routine maintenance (everyday)
- Check condition of insulation of power lead. If any insulation damage exists replace the lead immediately.
Periodic maintenance (every 200 working hours but at least once a year)
Perform the routine maintenance and, in addition:
- Keep the machine clean. Using a dry (and low pressure) airflow, remove the dust from the external case and from the cabinet inside.
The frequency of the maintenance operations may vary in accordance with the
working environment where the machine is placed.
WARNING
- Do not touch electrically live parts.
- Before removed case, machine has to be turned off and the power lead has to be disconnected.
- Mains supply network must be disconnected from the machine before each maintenance and service. After each repair, perform proper tests to ensure safety.
Customer Assistance Policy
The business of The Lincoln Electric Company is manufacturing and selling high
quality welding equipment, consumables, and cutting equipment. Our challenge
is to meet the needs of our customers and to exceed their expectations. On
occasion, purchasers may ask Lincoln Electric for advice or information about
their use of our products. We respond to our customers based on the best
information in our possession at that time. Lincoln Electric is not in a
position to warrant or guarantee such advice, and assumes no liability, with
respect to such information or advice. We expressly disclaim any warranty of
any kind, including any warranty of fitness for any customer’s particular
purpose, with respect to such information or advice. As a matter of practical
consideration, we also cannot assume any responsibility for updating or
correcting any such information or advice once it has been given, nor does the
provision of information or advice create, expand or alter any warranty with
respect to the sale of our products
Lincoln Electric is a responsive manufacturer, but the selection and use of
specific products sold by Lincoln Electric is solely within the control of,
and remains the sole responsibility of the customer. Many variables beyond the
control of Lincoln Electric affect the results obtained in applying these
types of fabrication methods and service requirements.
Subject to Change – This information is accurate to the best of our knowledge
at the time of printing. Please refer to www.lincolnelectric.com for any
updated information.
WEEE
Do not dispose of electrical equipment together with normal waste!
In observance of European Directive 2012/19/EC on Waste Electrical and
Electronic Equipment (WEEE) and its implementation in accordance with national
law, electrical equipment that has reached the end of its life must be
collected separately and returned to an environmentally compatible recycling
facility. As the owner of the equipment, you should get information on
approved collection systems from our local representative.
By applying this European Directive you will protect the environment and human
health!
Spare Parts
Part List reading instructions
- Do not use this part list for a machine if its code number is not listed. Contact the Lincoln Electric Service Department for any code number not listed.
- Use the illustration of assembly page and the table below to determine where the part is located for your particular code machine.
- Use only the parts marked “X” in the column under the heading number called for in the assembly page (# indicate a change in this printing).
First, read the Part List reading instructions above, then refer to the “Spare Part” manual supplied with the machine that contains a picture-descriptive part number cross-reference.
REACH
Communication in accordance with Article 33.1 of Regulation (EC) No 1907/2006
– Reach.
Some parts inside this product contain:
- Bisphenol A, BPA, EC 201-245-8, CAS 80-05-7
- Cadmium, EC 231-152-8, CAS 7440-43-9
- Lead, EC 231-100-4, CAS 7439-92-1
- Phenol, 4-nonyl-, branched, EC 284-325-5, CAS 84852-15-3
in more than 0,1% w/w in homogeneous material. These substances are included
in the ʺCandidate List of Substances of Very High Concern for Authorisationʺ
of REACh.
Your particular product may contain one or more of the listed substances.
Instructions for safe use:
- use according to Manufacturer instructions, wash hands after use;
- keep out of reach of children, do not put in mouth,
- dispose in accordance with local regulations.
Authorized Service Shops Location
- The purchaser must contact Lincoln Electric or Authorized Service Facility about any defect claimed under warranty period.
- Contact your local Sales Representative for assistance in locating the nearest Authorized Service Facility.
Accessories
OPTIONS & ACCESSORIES
K14366-1| RC7 EXTENSION CABLE – 5M
K14290-1| 12-PIN REMOTE HARNESS KIT (POWERTEC®, DIGISTEEL, CITOSTEEL)
K14348-1| 12-PIN REMOTE HARNESS KIT (SPEEDTEC®)
K14132-1| ADAPTER
K14131-1| ARCLINK –T FLEX
Connection configuration
Read User Manual Online (PDF format)