Black Decker BPACT08WT PORTABLE AIR CONDITIONER Remote Control Instruction Manual
- June 5, 2024
- Black Decker
Table of Contents
BPACT08WT PORTABLE AIR CONDITIONER Remote Control
Instruction Manual CATALOG NUMBER
BPACT08WT BPACT10WT BPACT12WT
BPACT12HWT BPACT14WT BPACT14HWT
Thank you for choosing BLACK+DECKER!
PLEASE READ BEFORE RETURNING THIS PRODUCT FOR ANY REASON.
If you have a question or experience a problem with your BLACK+DECKER
purchase, go to
www.blackanddecker.com/instantanswers
If you can’t find the answer or do not have access to the Internet, call
844-299-0879 from 10:30 a.m. to 6:30
p.m. EST Mon. – Fri. to speak with an agent. Please have the catalog number
available when you call.
SAVE THIS MANUAL FOR FUTURE REFERENCE.
PRODUCT REGISTRATION
Thank you for purchasing our BLACK+DECKER product. This easy-to-use manual
will guide you in getting the best use of your air conditioner.
Remember to record the model and serial numbers. They are on a label on the
rear.
Model number ——————————-
Serial number ——————————-
Date of purchase ————————–
Staple your receipt to your manual.
You will need it to obtain warranty service.
SAFETY INFORMATION
DANGER | WARNING | CAUTION |
---|
DANGER – Immediate hazards which WILL result in severe personal injury or death| WARNING – Hazards or unsafe practices which COULD result in severe personal injury or death| CAUTION – Hazards or unsafe practices which COULD result in minor personal injury
IMPORTANT SAFETY INSTRUCTIONS
WARNING
When using electrical appliances, basic safety precautions should be followed,
including the following
-
To reduce risk of injury, read this guide before using the appliance.
-
Air conditioner must be connected to proper electrical outlet with the correct electrical supply.
-
Proper grounding must be ensured to reduce the risk of shock and fire. DO NOT CUT OR REMOVE THE GROUNDING PRONG. If you do not have a three-prong electric receptacle outlet in the wall, have a certified electrician install the proper receptacle. The wall receptacle MUST be properly grounded.
-
Do not operate air conditioner if power cord is frayed or otherwise damaged.
Avoid using it if there are any cracks or abrasion damage along the length, plug connector or if the unit malfunctions or is damaged in any manner. Contact an authorized service technician for examination, repairs or adjustments. -
DO NOT USE AN ADAPTER OR AN EXTENSION CORD.
-
Do not block airflow around the air conditioner. The exhaust hose should be free of any obstructions.
-
Always unplug the air conditioner before servicing or moving the unit.
-
Do not install or use the air conditioner in any area where the atmosphere contains combustible gases or where the atmosphere is oily or sulfurous. Avoid any chemicals coming in contact with your air conditioner.
-
Do not place any object on the top of the unit.
-
Never operate the air conditioner without filters in place.
-
Do not use the air conditioner near a bathtub, shower or wash basin.
-
This appliance is not intended for use by persons (including children) with reduced physical sensory or mental capabilities or lack of experience & knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
-
Children should be supervised to ensure that they do not play with the appliance.
-
If the SUPPLY CORD is damaged, it must be replaced by the manufacturer, a service agent or similarly qualified persons in order to avoid a hazard.
-
The air conditioner shall be installed in accordance with national wiring regulations.
HANDLING ALKALINE BATTERIES
WARNING
When handling alkaline batteries, basic safety precautions should be followed,
including the following
- Should fluid from the battery accidentally get into your eyes, there is a threat of loss of eyesight, do not rub them. Immediately rinse your eyes with clean tap water and then consult a physician immediately.
- Do not put the battery in a fire, expose it to heat, dismantle or modify it. If the insulation or safety valve is damaged, the battery may leak fluid, overheat or explode.
- Do not insert the battery with the poles reversed. Doing so may cause some abnormality or a short and the battery may leak fluid, overheat or explode.
- Keep the battery out of the reach of children. If the battery is swallowed, contact a physician immediately.
- If the alkali fluid gets in your mouth, rinse your mouth with water and contact a physician immediately.
- If the alkali fluid gets on your skin or clothes, it may burn your skin, thoroughly rinse the affected area with tap water.
- Do not mix new and old batteries or other makes of batteries. The different attributes may cause the battery to leak fluid, overheat or explode.
- This battery was not made to be recharged. Recharging this battery may damage the insulation or internal structure and may cause the battery to leak fluid, overheat or explode.
- Do not damage or remove the label on the exterior of the battery. Doing so may cause the battery to short, leak fluid, overheat or explode.
- Do not drop, throw or expose the battery to extreme impact. Doing so may cause the battery to leak fluid, overheat or explode.
- Do not alter the shape of the battery. If the insulation or safety valve is damaged, the battery may leak fluid, overheat or explode.
- Immediately remove batteries when they have lost all power. Leaving the batteries in the unit for a long time may cause the batteries to leak fluid, overheat or explode due to gas that is generated by the batteries.
- Remove the batteries from the unit when not using the unit for an extended period of time. The batteries may leak fluid, overheat or explode due to gas that is generated by the batteries.
- Do not apply solder directly to the batteries. The heat may cause the batteries to leak fluid, overheat or explode.
- Do not get the batteries wet. Doing so may cause the batteries to overheat.
- Store batteries someplace out of direct sunlight where the temperature and humidity are not high. Not doing so may cause the batteries to leak fluid, overheat or explode. Also, it may cause the life and performance of the batteries to decline.
- Follow the regulations of the local government when disposing of these batteries.
- NEVER mix alkaline, standard (carbon-zinc), rechargeable (nickel-cadmium) batteries with this product.
SAVE THESE INSTRUCTIONS HOUSEHOLD USE ONLY
GROUNDING INSTRUCTIONS
ELECTRICAL REQUIREMENTS
In the event of malfunction or breakdown, grounding provides a path of least
resistance for electric current to reduce the risk of electric shock. The
appliance must be connected to a cord having an equipment-grounding conductor
and a grounding plug. The plug must be plugged into an appropriate outlet that
is properly installed and grounded in accordance with all local codes and
ordinances.
DANGER – Improper connection of the equipment-grounding conductor can
result in a risk of electric shock. The conductor with insulation having an
outer surface that is green with or without yellow stripes is the equipment
grounding conductor. If repair or replacement of the cord or plug is
necessary, do not connect the equipment-grounding conductor to a live
terminal. Check with a qualified electrician or service person if the
grounding instructions are not completely understood, or if in doubt as to
whether the appliance is properly grounded. Do not modify the plug connected
to the appliance – if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
FOR GROUNDED, CORD-CONNECTED APPLIANCE RATED LESS THAN 15A AND INTENDED FOR
USE ON A NOMINAL 120V SUPPLY CIRCUIT
The appliance is for use on a nominal 120V circuit and should be connected to
a grounding outlet that looks like the one illustrated below. The use of a
temporary adapter is not recommended.
LCDI POWER CORD AND PLUG
This air conditioner is equipped with an LCDI (Leakage Current Detection and
Interruption) power cord that is required by UL. This power supply cord
contains state-of-the-art electronics that sense leakage current. If the cord
is damaged and leakage occurs, power will be disconnected from the unit.
The test and reset buttons on the LCDI Plug are used to check if the plug is
functioning properly.
WARNING: Test LCDI before each use.
To test the plug:
- Plug power cord into a grounded 3-prong outlet.
- Press RESET (on some units a green light will turn on).
- Press the TEST button, the circuit should trip and cut all power to the air conditioner (on some units green light may turn off).
- Press the RESET button for use. You will hear a click and the A/C is ready for use.
- The power supply cord must be replaced if it fails to trip when the TEST button is pressed and the unit fails to reset.
NOTE:
- Do not use this device to turn the unit on or off.
- Always make sure the reset button is pushed in for correct operation.
WARNING:
- The power supply cord must be replaced if it fails to reset when either the test button is pushed, or it cannot be reset.
- If power supply cord is damaged, it cannot be repaired.
- It must be replaced by one obtained from the product manufacturer.
WARNING- RISK OF FIRE
It is important the plug fits tightly into the wall outlet.
If the plug does not fit securely and appears loose, it should not be used.
Have a licensed electrician replace the receptacle.
SAFETY GUIDELINES
WARNING: To prevent injury to the user or other people and property
damage, the following instructions must be followed. Incorrect operation due
to ignoring of instructions may cause harm or damage.
-
Your air conditioner should be used in such a way that it is protected from moisture. e.g. condensation, splashed water, etc. Do not place or store your air conditioner where it can fall or be pulled into water or any other liquid. Unplug immediately.
-
Always transport your air conditioner in a vertical position and stand on a stable, level surface during use.
-
Turn off the product when not in use.
-
Always use the switch on the control panel to start or shut off the unit.
-
Always contact a qualified person to carry out repairs. If the supply cord is damaged it must be repaired by a qualified technician.
-
Keep an air path of at least 12 inches all around the unit from walls, furniture and curtains.
-
If the air conditioner is knocked over during use, turn off the unit and unplug from the power supply immediately.
-
Do not operate your air conditioner in a wet room such as a bathroom or laundry room.
-
Do not touch the unit with wet or damp hands or when barefoot.
-
Do not press the buttons on the control panel with anything other than your fingers.
-
Do not remove any fixed covers. Never use this appliance if it is not working properly, or if it has been dropped or damaged.
-
Never use the plug to start and stop the unit.
-
Always use the switch on the control panel to start or shut off the unit.
-
Do not cover or obstruct the inlet or outlet grilles.
-
Do not use hazardous chemicals to clean or come into contact with the unit. Do not use the unit in the presence of inflammable substances or vapor such as alcohol, insecticides, petrol, etc.
-
Do not allow children to operate the unit unsupervised.
-
Do not use this product for functions other than those described in this instruction manual.
-
Use the unit in the recommended room size.
8,000 BTU up to 350 sq. ft.
10,000 BTU up to 450 sq. ft.
12,000 BTU up to 550 sq. ft.
14,000 BTU up to 700 sq. ft. -
Locate the unit where furniture cannot obstruct the air flow.
-
Keep blinds/curtains drawn.
-
Keep the filters clean.
-
Keep doors and windows closed to keep cool air in and warm air out.
OPERATING CONDITIONS
The air conditioner must be operated within the temperature range indicated
below:
NOTE: Unit performance may be affected when in use outside of these
operating temperatures.
MODE | ROOM TEMPERATURE |
---|---|
COOL | 64˚F (18˚C) ~ 76˚F (24˚C) |
(Maximum humidity:75.2°F / 24°C )
DRY| 64˚F (18˚C) ~ 95˚F (35˚C)
HEAT (Heat models BPACT12HWT and BPACT14HWT only)| 45˚F (7˚C) ~ 81˚F (27˚C)
SET UP & USE
PARTS & FEATURES
INSTALLATION GUIDE
LOCATION
- The air conditioner should be placed on a firm floor to minimize noise and vibration. For safe and secure positioning, place the unit on a smooth, level floor strong enough to support the unit.
- The unit has casters to aid placement, but it should be rolled on smooth, flat surfaces. Use caution when rolling on carpet surfaces. Do not attempt to roll the unit over objects.
- The unit must be placed within reach of a properly rated grounded socket.
- Never place any obstacles around the air inlet or outlet of the unit.
- A removal air-conditioner shall be installed in the flat and empty place all around. Don’t block the air outlet, and the required distance around should be at least 80cm required distance above should be at least 50cm.
SUGGESTED TOOLS FOR WINDOW KIT INSTALLATION
- Screwdrivers (medium size Phillips)
- Tape measure or ruler
- Knife or scissors
- Saw (In the event that the window kit needs to be cut down in size because the window is too narrow for direct installation)
WINDOW SLIDER KIT INSTALLATION
Your window slider kit has been designed to fit most standard “Vertical” and
“Horizontal” window applications; however, it may be necessary for you to
improvise/modify some aspect of the installation procedures for certain types
of windows. Minimum and maximum window openings:
MAXIMUM: 48.4” (123 cm) MINIMUM: 26.5” (67.5 cm)
NOTE: · A plastic locking pin is holding the window slider kit together
during shipment. Prior to installation, remove the plastic locking pin, adjust
to the desired length and use provided metal locking screws to secure it.
NOTE: · If the window opening is less than 26.5”, the minimum length of
the window slider kit, cut the one with a hole in it short to fit for the
window opening. Never cut out the hole in window slider kit.
DOUBLE-HUNG SASH/SLIDING CASEMENT WINDOW INSTALLATION
-
Cut the foam seal (adhesive type) to the proper length and attach it to the window sash.
-
Attach the window slider kit to the window sash. Adjust the length of the window slider kit according to the width of window. Shorten the adjustable window kit if the width of window is less than 26.5”.
-
Cut the foam seal (adhesive type) to the proper length and attach it on the top of the window.
-
Close the window securely against the window slider kit.
-
Secure the window slider kit to the window sash.
-
Cut the foam seal to an appropriate length and seal the open gap between the top window frame and outer window frame.
EXHAUST HOSE INSTALLATION
The air exhaust hose and hose inlet must be installed or removed from the
portable air conditioner in accordance with the way it is being used:
COOL, DEHUMIDIFY and HEAT (Heat model BPACT12HWT and BPACT14HWT only): Air
exhaust hose and hose inlet should be connected to the portable air
conditioner.
FAN: Air exhaust hose and hose inlet should be disconnected from the
portable air conditioner.
To install:
-
The hose outlet and inlet are pre-assembled to the air exhaust hose.
-
Align the hose inlet with the slots over the air exhaust hose housing outlet to assemble.
-
Insert the hose outlet into the window panel.
-
Affix the hose outlet into the window slider kit and seal.
NOTE: The exhaust hose can be compressed or extended moderately, but it is desirable to keep the length to a minimum. Also make sure that the hose does not have any sharp bends. CONTROL PANEL ****
OPERATING FROM THE CONTROL PANEL
The Control Panel enables you to manage all the main functions of the
appliance, but to fully utilize its potential, you must use the remote control
unit.
TURNING THE APPLIANCE ON
-
Press the button until the appliance turns on. The last function active when it was turned off will appear.
-
Never turn the air conditioner off by unplugging it from the main power supply. Always press the button, then wait for a few minutes before unplugging. This allows the appliance to perform a cycle of checks to verify operation.
NOTE: Before pressing the Power button, make sure the condensate drain plug in the rear of the unit is securely in place to avoid any leaking. -
Press the MODE button until the light corresponding to the required Mode lights up.
COOL MODE
Ideal for hot weather when you need to cool and dehumidify the room. To set
the operation of the appliance correctly, press the Temp Up or Temp Down
buttons until the desired temperature is displayed.
Then select the fan speed by pressing the Fan Speed Button until the light
corresponding to the required fan speed lights up:
HIGH: The fan operates at maximum to reach the required temperatures as
rapidly as possible.
MED: Reduces Fan noise level but still maintains a good level of comfort.
LOW: For quiet operation.
AUTO: The appliance automatically selects the most suitable fan speed in
relation to the temperature set on the digital display.
DEHUMIDIFY MODE
Ideal for reducing humidity in spring and autumn, during rainy spells or in
damp rooms, etc.
An exhaust hose attachment is recommended for more effective dehumidification
but not required.
In dehumidifying mode, the fan speed is automatically set to a low speed and
cannot be adjusted.
When an error code appears on the display screen on the control panel “E2”,
the unit will have to be drained.
FAN MODE
Press the mode key until the fan mode indicator lights up, indicating that the
fan function is selected.
Press the speed button to select the appropriate fan speed.
HEAT MODE (Heat models BPACT12HWT and BPACT14HWT only)
Press the MODE button until the HEAT mode indicator light appears. Select the
target temperature by pressing the or button until the corresponding value is
displayed. (Temperature range is 61º F-88º F (16º C-31º C)
Then select the fan speed by pressing the Fan Speed Button until the light
corresponding to the desired fan speed lights up: HIGH, MED, LOW, AUTO.
NOTE: At the beginning of this mode, you may have to wait a few seconds
before the appliance starts to give out hot air.
When an error code appears on the display screen “E4” in HEAT mode, the unit
will have to be drained.
NOTE: AUTO speed can only be selected using the control panel.
OPERATING FROM THE REMOTE CONTROL
BATTERY INSTALLATION (BATTERIES NOT INCLUDED)
- Slide open the battery compartment cover.
- Insert 2 × “AAA” batteries as shown.
- Slide back the battery cover.
CAUTION: Use only AAA or IEC R03 1.5V alkaline batteries. Remove the
batteries if the remote is not used for a month or longer. Do not attempt to
recharge the batteries. Both batteries should be replaced at the same time. Do
not dispose of the batteries in a fire as they may explode.
Point the remote control at the receiver on the appliance. The remote control
must be no more than 7 meters away from the appliance (without obstacle
between the remote control and the receiver).
The remote control must be handled with extreme care. Do not drop it or expose
it to direct sunlight or sources of heat.
REMOTE CONTROL
POWER BUTTON: Press to Turn ON or OFF
TIMER BUTTON: Used to set a delay start or shut down time.
MODE BUTTON: Press the button to scroll through COOL, DEHUMIDIFY, FAN or
HEAT (HEAT mode for models BPACT12HWT and BPACT 14HWT only)
ºC SELECTOR BUTTON: Celsius Display ON
ºF SELECTOR BUTTON: Fahrenheit Display ON
INCREASE: Increase the temperature/time setting.
DECREASE: Decrease the temperature/time setting.
LIGHT ON/OFF BUTTON: Illuminates the LED screen on the unit.
FAN SPEED BUTTON: Use to select the Low, Medium or High fan speed.
SLEEP BUTTON: Gradually adjusts the temperature.
| Cool mode| | Fan speed
---|---|---|---
| Dehumidify mode| | Timer on
| Fan mode| 24 hr
| Timer o
| Heat mode| | Sleep
| Display temp. or| ºC/F| Fahrenheit or
POWER BUTTON
- Press to Turn Air Conditioner ON or OFF. Press the LED button to illuminate the LED screen on the unit.
- It will show on the remote LED screen when buttons are pressed to show that the remote control is sending a signal to the air conditioner.
MODE BUTTON
- Press the mode button to scroll through COOL , DEHUMIDIFY , FAN , HEAT (Heat models BPACT12HWT and BPACT14HWT only).
- The corresponding symbol will illuminate on the LED display to indicate which mode is selected.
COOL
- Select the target temperature 61˚F–88˚F (16˚C – 31˚C) by pressing the + or – buttons until the desired temperature is displayed on the LED screen.
- Press the Fan Speed Button to select Low, Medium, or High Speed.
DEHUMIDIFY
-
Ideal for reducing humidity.
-
Keep window and door closed for the best dehumidifying effect.
-
An exhaust hose attachment is not required in this mode but it is recommended for more effective dehumidification.
-
It is recommended that the dehumidification drain and drain hose be used for continuous drainage.
-
FULL TANK – When an error code appears on the display screen on the control panel “E2” in COOL or DEHUMIDIFY mode or “E4” in HEAT mode, the unit will have to be drained.
NOTE: Refer to the Water Drainage section. -
In this mode, fan speed is selected automatically by the appliance and can not be set manually.
FAN
- Press the Fan Speed Button to select Low, Medium or High Speed.
HEAT (Heat models BPACT12HWT and BPACT14HWT only)
- Select the target temperature 61˚F–88˚F (16˚C–31˚C) by pressing the + or – buttons until the desired temperature is displayed on the LED screen.
- Press the speed button to select Low, Medium or High fan speed.
NOTE: At the beginning of this mode, you may have to wait a few seconds before the appliance starts to give out hot air.
TIMER
- To set the AUTO STOP timer. When the unit is ON, press the TIMER button. The TIME ON/OFF symbol on the remote LCD display will blink.
- Press the + or – button to select the AUTO TIME by 1-hour increments, up to 24 hours. The Remote LCD Display will indicate the selected time. Press the TIMER button again to set the selected time. There will be a steady TIME ON/OFF symbol on the remote LCD display and the TIMER indicator light will be illuminated on the control panel of the unit to show that the AUTO STOP program is initiated.
- To set the AUTO START timer. When the unit is OFF, press the TIMER button. The TIME ON/OFF symbol on the remote LCD display will blink.
- Press the + or – button to select the AUTO TIME by 1-hour increments, up to 24 hours. The Remote LCD Display will indicate the selected time. Press the TIMER button again to set the selected time. There will be a steady TIME ON/OFF symbol on the remote LCD display and the TIMER indicator light will be illuminated on the control panel of the unit to show that the AUTO START program is initiated.
- Pressing the POWER button or the TIMER button will cancel the AUTO START/STOP timed program and the timer indicator light will not be illuminated.
SLEEP
- The SLEEP function gradually adjusts the temperature of the rooms to provide a comfortable environment. Press the SLEEP button to activate.
- In COOL mode, the temperature will increase 2°F after an hour and 4°F after 2 hours.
- In HEAT mode, the temperature will decrease 2°F after an hour and 4°F after 2 hours.
- To cancel this setting press the SLEEP button again.
°C/°F SELECTOR BUTTONS
- When the appliance is powered on, press the °F selector button to display the temperature in Fahrenheit.
- Press the °C selector button to display the temperature in Celsius.
WATER DRAINAGE FOR COOL AND HEAT MODES
This air conditioner is equipped with auto water evaporation so the water
compartment would not typically fill in cooling or heating mode unless there
is high humidity. Water drainage will generally only be required at the end of
the season for these modes. (see START-END OF SEASON OPERATIONS).
NOTE: When an error code appears on the display screen on the control
panel “E2” in COOL or DEHUMIDIFY mode, or “E4” in HEAT mode, the unit will
have to be drained.
Intermittent Draining
- Unplug the unit from the power source. Carefully move the unit to a drain area over your basement floor or drip pan (not included). Remove the bottom drain cap.
- Let the water drain away and replace the drain cap. Restart the machine until the error codes E2 or E4 disappears. If the error repeats, call for service.
NOTE: Be sure to reinstall the bottom drain plug before using the unit.
Continuous Draining
- Unplug the unit from the power source. Remove the bottom drain cap. While doing this operation, some residual water may spill. Have a drip pan (not supplied) to collect the water.
- Connect the drain hose (supplied) as shown in the diagram. The water can be continuously drained through the hose into a floor drain or drip tray.
- Turn on the unit.
WAIT 3 MINUTES BEFORE RESUMING THE OPERATION
- After the unit has stopped, it cannot be restarted for 3 minutes. The operation will automatically restart after 3 minutes.
Continuous Draining for Dehumidification Mode
- Unplug the unit from the power source.
- Remove the drain cap located in the back center of the unit. While doing this operation, some residual water may spill. Have a drip pan (not supplied) to collect the water.
- Connect the drain hose (supplied) as shown in the diagram. The water can be continuously drained through the hose into a floor drain or bucket.
Turn on the unit.
WAIT 3 MINUTES BEFORE RESUMING THE OPERATION
- After the unit has stopped, it cannot be restarted for 3 minutes. The operation will automatically restart after 3 minutes.
CLEANING & CARE
CLEANING
WARNING: Before cleaning or maintenance, turn the appliance off by
pressing the button on the control panel or the button on the remote control.
Unplug from the electrical outlet.
CLEANING THE CABINET
You should clean the appliance with a slightly damp cloth and then dry it with
a dry cloth.
- Never saturate the air conditioner with water.
- Never use petrol, alcohol or solvents to clean the appliance.
- Never spray insecticide liquids or similar near the air conditioner.
CLEANING THE FILTER
To keep your air conditioner working efficiently, you should clean the
evaporator filter every week of operation.
The filter is housed in the intake grill.
Use a vacuum cleaner to remove dust accumulations from the filter.
If it is very dirty, immerse it in warm water and rinse a number of times.
The water should be lukewarm.
After washing, leave the filter to dry then re-insert the filter.
START-END OF SEASON OPERATIONS
START OF SEASON CHECKS
Make sure the power cable and plug are undamaged.
Follow the installation instructions precisely.
END-OF-SEASON OPERATIONS
See the Water Drainage section to make sure the air conditioner is completely
drained of water.
Clean the filter and dry thoroughly before reinstalling
TROUBLESHOOTING & WARRANTY
BEFORE YOU CALL FOR SERVICE
IF THE AIR CONDITIONER FAILS TO OPERATE:
A) Check to make sure that the air conditioner is plugged in securely. If it
is not, remove the plug from the outlet, wait 10 seconds and plug it in again
securely.
B) Check for a blown circuit fuse or a tripped main circuit breaker. If these
seem to be operating properly, test the outlet with another appliance.
WARNING
IF NONE OF THE ABOVE SOLVES THE PROBLEM, CONTACT A QUALIFIED TECHNICIAN. DO
NOT TRY TO ADJUST OR REPAIR THE AIR CONDITIONER YOURSELF.
Any person who is involved with working on or breaking into a refrigerant
circuit should hold a currently valid certificate from industry accredited
assessment authority, which authorizes their competence to handle refrigerants
safely in accordance with an industry-recognized assessment specification.
WARNING
Do not use means to accelerate the defrosting process or to clean other than
those recommended by the manufacturer.
The appliance shall be stored in a room without continuously operating
ignition sources (for example open flames, an operating gas appliance or an
operating electric heater).
Do not pierce or burn.
Be aware that refrigerants may not contain an odor.
WARNING
Servicing shall only be performed as recommended by the equipment
manufacturer. Maintenance and repair requiring the assistance of other skilled
personnel shall be carried out under the supervision of the person competent
in the use of the flammable refrigerants.
CUSTOMER SERVICE
IMPORTANT
DO NOT RETURN THIS PRODUCT TO THE STORE
If you have a problem with this product, please contact the W Appliance Co.
Customer Satisfaction Center at
844-299-0879.
DATED PROOF OF PURCHASE, MODEL #, AND SERIAL # REQUIRED FOR WARRANTY SERVICE
Troubleshoot your problem by using the chart below. If the air conditioner still does not work properly, contact BLACK+DECKER customer service center or the nearest authorized service center. Customers must never troubleshoot internal components.
TROUBLE | POSSIBLE CAUSE | POSSIBLE REMEDY |
---|---|---|
Unit does not start when pressing ON/OFF button | A. The water tank may be full |
if LED display indicates “E2” in COOL or DEHUMIDIFY mode, or “E4” in HEAT
mode.| A. Drain the water
B. Reset the temperature
Not cool enough| A. The windows or doors in the room are not closed
B. There are heat sources inside the room
C. Exhaust air duct is not connected or blocked
D. Temperature setting is too high
E. Air filter is blocked by dust
F. The unit will take approx 3 minutes of operation before cooling/heating
occurs.| A. Make sure all the windows and doors are closed
B. Remove the heat sources if possible
C. Connect the duct and make sure it can function properly
D. Decrease the set temperature
E. Clean the air filter
F. A microprocessor control delays the compressor from operating until 3 mins
have passed.
Noisy or vibration| A. The surface is not level or not flat enough| A. Place
the unit on a flat, level surface if possible
Unit does not run and indicates “E2” in COOL or DEHUMIDIFY mode, or “E4” in
HEAT mode.| A. The unit needs to be drained.| A. Refer to the water drainage
section.
LED display “E0” , “E1”, “E3”| A. EO – Room temperature sensor issue
B. E1- Condenser temperature sensor
C. E3- Evaporator temperature sensor| A. Contact the Customer Satisfaction
Center for
assistance with the error code.
The Remote is not working| A. Nothing Appears on the LED screen.
B. The temperature and symbols appear on the LED screen but the selection
cannot be changed.| A. Press the LED button on the remote. If it does not
illuminate, change the batteries.
B. Make sure the remote is being pointed at the
remote control receiver on the unit within 23 feet away and that there are no
obstructions.
LIMITED WARRANTY
Any repair, replacement, or warranty service, and all questions about this
product should be directed to W Appliance Co. at
844-299-0879 from the USA or Puerto
Rico.
W Appliance Co. warrants to the original purchaser that the product will be
free from defects in material, parts and workmanship for the period designated
for this product. The warranty commences the day the product is purchased and
covers up to a period of 1 year (12 months) for labor/1 year (12 months) for
parts (manufacturing defects only)/and a total of 5 years (60 months) for
compressor part only.
W Appliance Co. agrees that it will, at its option, replace the defective
product with either a new or remanufactured unit equivalent to your original
purchase during the warranty period.
Exclusions: This warranty does not apply to the below:
- If the appearance or exterior of the product has been damaged or defaced, altered or modified in design or construction.
- If the product’s original serial number has been altered or removed or cannot be readily determined.
- If there is damage due to a power line surge, user damage to the AC power cord or connection to an improper voltage source.
- If damage is due to general misuse, accidents or acts of God.
- If repair attempts are done by unauthorized service agents, use of parts other than genuine parts or parts obtained from persons other than authorized service companies.
- On units that have been transferred from the original owner.
- On products that have been purchased as refurbished, like new, second-hand, in a “As-Is” or “Final Sale” terms.
- To products used in a commercial or rental setting.
- To products used in settings other than ordinary household use or used other than in accordance with the provided instructions.
- To damages for service calls for improper installations.
- Transportation and shipping costs are associated with the replacement of the unit.
- Service calls to instruct you how to use your product.
- Service calls to repair or replace the house fuse, reset the circuit breaker or correct the wiring in the house.
REPAIR OR REPLACEMENT AS PROVIDED UNDER THIS WARRANTY IS THE EXCLUSIVE REMEDY
OF THE CUSTOMER; W Appliance Co. SHALL NOT BE LIABLE FOR ANY INCIDENTAL OR
CONSEQUENTIAL DAMAGES FOR BREACH OF ANY EXPRESS OR IMPLIED WARRANTY ON THIS
PRODUCT, EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW. ANY IMPLIED
WARRANTY OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE ON THIS
PRODUCT IS LIMITED TO THE DURATION OF THE WARRANTY.
Some states do not allow the exclusion or limitations of incidental or
consequential damages, or limitations on how long the warranty lasts. In these
cases the above exclusions or limitations may not apply to you. This warranty
gives you specific legal rights and you may also have other rights which vary
from state to state.
Obtaining Service: To obtain service, product literature, supplies or
accessories please call
844-299-0879 to create a ticket for
exchange/repair. Please make sure to provide the date of purchase, model
number and a brief description of the problem. Our customer service
representative will contact you or send detailed return instructions.
W Appliance Co. does not warrant that the appliance will work properly in all
environmental conditions, and makes no warranty and representation, either
implied or expressed, with respect to the quality, performance,
merchantability, or fitness for a particular purpose other than the purpose
identified within this user’s manual. W Appliance Co. has made every effort to
ensure that this user’s manual is accurate and disclaims liability for any
inaccuracies or omissions that may have occurred. Information in this user’s
manual is subject to change without notice and does not represent a commitment
on the part of W Appliance Co.. W Appliance Co. reserves the right to make
improvements to this user’s manual and/or to the products described in this
user’s manual at any time without notice. If you find information in this
manual that is incorrect, misleading, or incomplete, please contact us at
844-299-0879.
W Appliance Co.
1356 Broadway
New York, NY 10018
This device complies with part 15 of the FCC rules. Operation is subject to
the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC rules. These limits are
designed to protect reasonably against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no
guarantee that the interference will not occur in a particular installation.
Suppose this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on. In
that case, the user is encouraged to try to correct the interference by one or
more of the following measures:
a) Reorient or relocate the receiving antenna.
b) Increase the separation between the equipment and the receiver.
c) Connect the equipment into an outlet different from that which the receiver
is connected.
d) Consult the dealer or an experienced radio/TV technician for help.
BLACK & DECKER, BLACK+DECKER, the BLACK & DECKER and BLACK+DECKER logos and
product names and the orange and black color scheme are trademarks of The
Black & Decker Corporation, used under license.
All rights reserved.
The product in this box may differ slightly from that pictured. Does not
affect function. Not all accessories shown in photography are included in this
package.
Imported by W Appliance, Inc, 1356 Broadway, New York, NY 10018
March 2022
Printed in China
Documents / Resources
|
Black Decker BPACT08WT PORTABLE AIR CONDITIONER Remote
Control
[pdf] Instruction Manual
BPACT08WT PORTABLE AIR CONDITIONER Remote Control, PORTABLE AIR CONDITIONER
Remote Control, AIR CONDITIONER Remote Control, Remote Control, BPACT10WT,
BPACT12WT, BPACT12HWT, BPACT14WT, BPACT14HWT
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>