LINCOLN ELECTRIC LF 56D Wire Feeder User Manual
- June 3, 2024
- LINCOLN ELECTRIC
Table of Contents
- Electromagnetic Compatibility (EMC) 01/11
- Safety
- Introduction
- Installation and Operator Instructions
- Controls and Operational Features
- User Interface Advanced (U7)
- Adjustments of Brake Torque of Sleeve
- Inserting Electrode Wire into Welding
- Changing Driving Rolls
- Gas Connection
- Maintenance
- Technical Specifications
- Customer Assistance Policy
- WEEE
- Spare Parts
- Reach
- Authorized Service Shops Location 09/16
- Electrical Schematic
- Accessories
- Connection configuration
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
LINCOLN ELECTRIC LF 56D Wire Feeder User Manual
Electromagnetic Compatibility (EMC) 01/11
This machine has been designed in accordance with all relevant directives and standards. However, it may still generate electromagnetic disturbances that can affect other systems like telecommunications (telephone, radio, and television) or other safety systems. These disturbances can cause safety problems in the affected systems. Read and understand this section to eliminate or reduce the amount of electromagnetic disturbance generated by this machine.
This machine has been designed to operate in an industrial area. To operate in a domestic area it is necessary to observe particular precautions to eliminate possible electromagnetic disturbances. The operator must install and operate this equipment as described in this manual. If any electromagnetic disturbances are detected the operator must put in place corrective actions to eliminate these disturbances, if necessary with assistance from Lincoln Electric.
Before installing the machine, the operator must check the work area for any devices that may malfunction because of electromagnetic disturbances. Consider the following.
- Input and output cables, control cables, and telephone cables that are in or adjacent to the work area and the machine.
- Radio and/or television transmitters and receivers. Computers or computer controlled equipment.
- Safety and control equipment for industrial processes. Equipment for calibration and measurement.
- Personal medical devices like pacemakers and hearing aids.
- Check the electromagnetic immunity for equipment operating in or near the work area. The operator must be sure that all equipment in the area is compatible. This may require additional protection measures.
- The dimensions of the work area to consider will depend on the construction of the area and other activities that are taking place.
Consider the following guidelines to reduce electromagnetic emissions from the machine.
- Connect the machine to the input supply according to this manual. If disturbances occur if may be necessary to take additional precautions such as filtering the input supply.
- The output cables should be as short as possible and positioned together as close as possible to each other. If possible connect the work piece to ground in order to reduce the electromagnetic emissions. The operator must check that connecting the work piece to ground does not cause problems or unsafe operating conditions for personnel and equipment.
- Shielding of cables in the work area can reduce electromagnetic emissions. This may be necessary for special applications.
WARNING
EMC classification of this product is class A in accordance with
electromagnetic compatibility standard EN 60974-10 which means that the
product is designed to be used in an industrial environment only.
WARNING
The Class A equipment is not intended for use in residential locations where
the electrical power is provided by the public low-voltage supply system.
There may be potential difficulties in ensuring electromagnetic compatibility
in those locations, due to conducted as well as radiated disturbances.
Safety
WARNING
This equipment have to be used by qualified personnel. Be sure that all
installation, operation, maintenance and repair procedures are performed only
by qualified person. Read and understand this manual before operating this
equipment. Failure to follow the instructions in this manual could cause
serious personal injury, loss of life, or equipment damage. Read and
understand the following explanations of the warning symbols. Lincoln Electric
is not responsible for damages caused by improper installation, improper care
or abnormal operation.
| WARNING: This symbol indicates that instructions must be followed to avoid
serious personal injury, loss of life, or equipment damage. Protect yourself
and others from possible serious injury or death.
---|---
| READ AND UNDERSTAND INSTRUCTIONS: Read and understand this manual before operating this equipment. Arc welding can be hazardous. Failure to follow the instructions in this manual could cause serious personal injury, loss of life, or equipment damage.
| ELECTRIC SHOCK CAN KILL: Welding equipment generates high voltages. Do not touch the electrode, work clamp, or connected work pieces when this equipment is turned on. Insulate yourself from the electrode, work clamp, and connected work pieces.
| ELECTRICALLY POWERED EQUIPMENT: Turn off the input power using the disconnect switch at the fuse box before working on this equipment. Ground this equipment in accordance with local electrical regulations.
| ELECTRICALLY POWERED EQUIPMENT: Regularly inspect the input, electrode, and
work clamp cables. If any insulation damage exists replace the cable
immediately. Do not place the electrode holder directly on the welding table
or any other surface in contact with the work clamp to avoid the risk of
accidental arc ignition.
| ELECTROMAGNETIC FIELD MAY BE DANGEROUS: Electric current flowing through any
conductor creates electromagnetic field (EMF). EMF fields may interfere with
some pacemakers, and welders having a pacemaker shall consult their physician
before operating this equipment.
| CE COMPLIANCE: This equipment complies with the European Community
Directives.
| ARTIFICIAL OPTICAL RADIATION: According with the requirements in 2006/25/EC
Directive and EN 12198 Standard, the equipment is a category 2. It makes
mandatory the adoption of Personal Protective Equipment (PPE) having filter
with a protection degree up to a maximum of 15, as required by EN169 Standard.
| FUMES AND GASES CAN BE DANGEROUS: Welding may produce fumes and gases
hazardous to health. Avoid breathing these fumes and gases. To avoid these
dangers the operator must use enough ventilation or exhaust to keep fumes and
gases away from the breathing zone.
| ARC RAYS CAN BURN: Use a shield with the proper filter and cover plates to
protect your eyes from sparks and the rays of the arc when welding or
observing. To protect the skin, use suitable clothing made of durable,
fireproof material. Protect other nearby personnel with suitable, non-
flammable screening and warn them not to watch the arc nor expose themselves
to the arc.
| WELDING SPARKS CAN CAUSE FIRE OR EXPLOSION: Remove fire hazards from the
welding area and have a fire extinguisher easily accessible. Welding sparks
and hot materials from the welding process can easily go through small cracks
and openings to adjacent areas. Do not weld on any tanks, drums, containers,
or material until the proper steps have been taken to insure that no flammable
or toxic vapors will be present. Never use this equipment when flammable
gases, vapors or flammable liquids are present.
| WELDED MATERIALS CAN BURN: Welding generates a large amount of heat. Hot
surfaces and materials in work area can cause serious burns. Use gloves and
pliers when touching or moving materials in the work area.
| CYLINDER MAY EXPLODE IF DAMAGED: Use only certificate, compressed gas
cylinders containing the correct shielding gas for the process used and
properly operating regulators designed for the gas and pressure used. Always
keep cylinders in an upright position securely chained to a fixed support. Do
not move or transport gas cylinders with the protection cap removed. Do not
allow the electrode, electrode holder, work clamp or any other electrically
live part to touch a gas cylinder. Gas cylinders must be located away from
areas where they may be subjected to physical damage or the welding process
including sparks and heat sources.
| MOVING PARTS ARE DANGEROUS: There are moving mechanical parts in this
machine, which can cause serious injury. Keep your hands, body and clothing
away from those parts during machine starting, operating and servicing.
| SAFETY MARK: This equipment
is suitable for supplying power for welding operations carried out in an
environment with increased risk of electric shock.
The manufacturer reserves the right to make changes and/or improvements in design without upgrade at the same time the operator’s manual.
Introduction
LF 56D is digital wire feeder which have been designed to work with Lincoln Electric power sources:
- POWERTEC® i350S,
- POWERTEC® i420S,
- POWERTEC® i500S,
- SPEEDTEC® 400SP,
- SPEEDTEC® 500SP,
- FLEXTEC® 350x,
- FLEXTEC® 500x.
The CAN protocol is used for communication between the power source and the wire feeder. All signals from the power source are displayed on the User Interface located in the wire feeder machine.
Set of power source and wire feeder allow welding in listed processes:
- GMAW (MIG/MAG),
- FCAW,
- SMAW (MMA),
- GTAW,
- CAG.
The complete package contains:
- Wire feeder.
- USB memory with operator’s manual.
- Easy Start
Recommended equipment, which can be bought by user, was mentioned in the chapter “Accessories”.
Installation and Operator Instructions
Read this entire section before installation or operating the machine.
Exploitation conditions
This machine can operate in harsh environments.
However, it is important to use the following simple preventive measures that
will ensure its long life and reliable operation:
- Do not place or operate this machine on a surface with an incline higher than 15° from horizontal.
- Do not use this machine for pipe thawing.
- This machine must be located where there is free circulation of clean air without restrictions for air movement. Do not cover the machine with paper, cloth or rags when switched on.
- Dirt and dust that can be drawn into the machine should be kept away from the item.
- This machine has a protection rating of IP23. Keep it dry when possible and do not place it on a wet ground or in puddles.
- Locate the machine away from a radio controlled machinery. Normal operation may adversely affect the operation of a nearby radio controlled machinery, which may result in injury or equipment damage. Read the section on electromagnetic compatibility in this manual.
- Do not operate in areas with an ambient temperature greater than 40°C.
Duty cycle and Overheating
The duty cycle of a welding machine is the percentage of time in a 10 minute
cycle at which the welder can operate the machine at rated welding current.
Example: 60% duty cycle:
Excessive extension of the duty cycle will cause the thermal protection
circuit to activate.
Input Supply Connection
Check the input voltage, phase, and frequency of the power source that will be
connected to this wire feeder.
The acceptable level of input voltage is indicated in the section „Technical
Specificationsʺ and on the rating plate of the power source. Verify the
connection of grounding wires from the power source to the input source.
Controls and Operational Features
-
EURO Socket: For connecting a welding gun (for GMAW, FCAW process).
-
Quick Coupling Socket: Coolant outlet (supplies cool coolant to the welding gun)
-
Quick Coupling Socket: Coolant inlet (takes warm coolant from the welding gun).
WARNING
Maximum coolant pressure is 5 bar.
- Output Socket for SMAW and CAG welding: For connecting welding cable with an electrode holder.
- U7 User Interface: See „User Interfaceʺ section.
- Gas Quick Coupling Socket: For connecting a gas pipe.
WARNING
The machine allows the use all suitable shielding gases with a maximum
pressure of 5 bar.
-
Control Socket: 5 pins socket for connecting a control cable. The CAN protocol is used for communication between the power source and wire feeder.
-
Current Socket: For connecting a welding cable.
-
Quick Coupling Socket: Coolant inlet (supplies cool coolant from cooler to the welding machine).
-
Quick Coupling Socket: Coolant outlet (takes warm coolant from welding machine to cooler).
-
Gas Flow Regulator Plug: Gas Flow Regulator can be purchased separately. See “Accessories” section.
-
Switch: Cold Inch / Gas Purge: This switch allows wire feeding (wire test) and gas flow (gas test) without switching on the output voltage.
-
Transport Holder: For the feeder lifting and transporting using a crane.
-
Wire Spool Holder: For wire spool with maximum 16kg weight. Holder allows mounting plastic, steel and fiber spools on the 51mm spindle.
WARNING
Be sure that wire spool case has to be completely closed during welding. -
Spool with Wire: Not supplied as standard.
-
Wire Drive: 4-rolls wire drive.
WARNING
The side panel and wire spool case have to be completely closed during welding.
WARNING
Do not use handle to move the machine during operation. -
Remote Control Socket: For connecting a Remote Control (see “Accessories” chapter).
-
USB Port: For connecting the USB memory and software updates.
User Interface Advanced (U7)
Detailed operation of User Interface U7 can be found in the Advanced (U7)
IM3170 user manual.
Loading the Wire Spool
Spools of wire with a maximum weight of 16 kg can be used without an adapter.
Holder allows mounting plastic, steel and fiber spools on the 51mm spindle.
It is possible to use other spools after using the appropriate adapter, which
can be purchased separately (see “Accessories” chapter).
Loading the Electrode Wire
- Turn the input power OFF.
- Open the spool wire case.
- Unscrew the locking nut of the sleeve [14].
- Load the spool wire on the sleeve so that the spool turns clockwise when the wire is feed into the wire feeder.
- Make sure that the spindle brake pin goes into the fitting hole on the spool.
- Screw in the locking nut of the sleeve.
- Open the wire drive door.
- Put on the wire roll with the correct groove corresponding to the wire diameter.
- Free the end of the wire and cut off the bent end making sure it has no burr.
WARNING
Sharp end of the wire can hurt.
- Rotate the wire spool clockwise and thread the end of the wire into the wire feeder as far as the Euro Socket.
- Adjust force pressure roll of the wire feeder properly.
Adjustments of Brake Torque of Sleeve
To avoid spontaneous unrolling of the welding wire the sleeve is fitted with a
brake.
Adjustment is carried by rotation of its screw M10, which is placed inside of
the sleeve frame after unscrewing the brake locking nut.
- Locking Nut.
- Adjusting Screw M10.
- Pressing Spring.
Turning the M10 screw clockwise increases the spring tension and increase the
brake torque Turning the M10 screw anticlockwise decreases the spring tension
and decrease the brake torque.
After finishing of adjustment, you should screw brake locking nut again.
Adjusting of Pressure Roll Force
The pressure arm controls the amount of force the drive rolls exert on the
wire. Pressure force is adjusted by turning the adjustment nut clockwise to
increase force, counterclockwise to decrease force. Proper adjustment of
pressure arm gives the best welding performance.
WARNING
If the roll pressure is too weak, the roll will slide on the wire. If the roll
pressure is set too heavy the wire may be deformed, which cause feeding
problems in the welding.
The pressure force should be set properly. For this purpose decrease the
pressure force slowly until the wire just begins to slide on the drive roll
and then increase the force slightly by turning of the adjustment nut by one
turn.
Inserting Electrode Wire into Welding
Torch
- Turn the welding machine off.
- Depending of welding process connect proper welding torch to the euro socket [1]. Rated parameters of the torch and welding machine should be matched.
- Depends on type of gun must be remove the nozzle from the gun and contact tip or protection cap and contact tip.
- Turn the welding machine on.
- Hold the Cold Inch/Gas Purge Switch [12] or use torch trigger until wire appear over threaded end of the gun.
- When the Cold Inch Switch [12] or torch trigger is released the spool of wire should not unwind.
- Adjust wire spool brake accordingly.
- Turn the welding machine off.
- Install a proper contact tip.
- Depending on the welding process and the type of the gun, install the nozzle (GMAW process) or protection cap (FCAW process).
WARNING
Take precaution to keep eyes and hands away from the end of the gun while the
wire is being come out of the threaded end.
Changing Driving Rolls
WARNING
Turn the input power off before installation or changing drive rolls.
Wire Feeders LF 56D is equipped with drive roll V1.0/V1.2 for steel wire. For
others wires and sizes it is required to install proper drive rolls kit (see
“Accessories” chapter) and follow instruction:
- Turn the input power OFF.
- Unlock 4 rolls by turning 4 Quick-Change Carrier Gear [26].
- Release the pressure roll levers [27].
- Change the drive rolls [25] corresponding to the used wire.
WARNING
Be sure that the gun liner and contact tip are also sized to match the
selected wire size
WARNING
For wires with the diameter larger than 1.6mm, the following parts have to be
changed:
- The guide tube of the feeding console [23] and [24].
- The guide tube of the Euro Socket [22].
- Lock 4 new rolls by turning 4 Quick-Change Carrier Gear [26].
- Insert the wire through the guide tube, over the roller and through the guide tube of Euro Socket into liner of gun. The wire can be pushed into the liner manually for a few centimeters, and should feed easily and without any force.
- Lock the pressure roll levers [27].
Gas Connection
WARNING
- CYLINDER may explode if damaged.
- Always fix the gas cylinder securely in an upright position, against a cylinder wall rack or purpose-made cylinder cart.
- Keep cylinder away from areas where it may be damaged, heated or electrical circuits to prevent possible explosion or fire.
- Keep cylinder away from welding or other live electrical circuits.
- Never lift welder with cylinder attached.
- Never allow welding electrode to touch cylinder.
- Build up of shielding gas may harm health or kill. Use in a well-ventilated area to avoid gas accumulation.
- Close the gas cylinder valves thoroughly when not in use to avoid leaks.
WARNING
Welding machine supports all suitable shielding gases at a maximum pressure of
5,0 bar.
WARNING
Before use, make sure that the gas cylinder contains gas suitable for the
intended purpose.
- Turn off input power at the welding power source.
- Install a proper gas flow regulator to the gas cylinder.
- Connect the gas hose to the regulator using the hose clamp.
- The other end of the gas hose connect to the gas connector on the power source rear panel or directly to the quick connector located on the rear panel of the wire feeder [6]. More details you will find in power source instruction manual.
- Connect by dedicated interconnection cable (see „Accessoriesʺ chapter) wire feeder and power source.
- Turn on input power at the welding power source.
- Open the gas cylinder valve.
- Adjust the shielding gas flow of the gas regulator.
- Check gas flow with Gas Purge Switch [12].
WARNING
To weld GMAW process with CO2 shielding gas, CO2 gas heater should be used.
Transport and Lifting
WARNING
Falling equipment can cause injury and damage to unit.
During transporting and lifting with a crane, adhere to the following rules:
- For lifting a suitable lifting equipment capacity.
- Dedicated handle [13] can be used to lifting and transporting using a crane only. This solution enables welding while lifting the feeder.
Maintenance
WARNING
For any repair operations, modifications or maintenances, it is recommended to
contact the nearest Technical Service Center or Lincoln Electric. Repairs and
modifications performed by unauthorized service or personnel will cause the
lost of the manufacturer’s warranty Any noticeable damage should be reported
immediately and repaired.
Routine maintenance (everyday)
-
Check condition of insulation and connections of the work leads and insulation of power lead. If any insulation damage exists replace the lead immediately.
-
Remove the spatters from the welding gun nozzle. Spatters could interfere with the shielding gas flow to the arc.
-
Check the welding gun condition: replace it, if necessary.
-
Check condition and operation of the cooling fan. Keep clean its airflow slots.
Periodic maintenance (every 200 working hours but at least once a year)
Perform the routine maintenance and, in addition: -
Keep the machine clean. Using a dry (and low pressure) airflow, remove the dust from the external case and from the cabinet inside.
-
If it is required, clean and tighten all weld terminals.
The frequency of the maintenance operations may vary in accordance with the working environment where the machine is placed.
WARNING
Do not touch electrically live parts.
WARNING
Before removed case, machine has to be turned off and the power lead has to be
disconnected from mains socket.
WARNING
Mains supply network must be disconnected from the machine before each
maintenance and service. After each repair, perform proper tests to ensure
safety.
Technical Specifications
NAME | INDEX |
---|---|
LF 56D | K14336-1 |
INPUT
Input Voltage U1| Input Amperes I1| EMC Class
40Vdc| 4Adc| A
RATED OUTPUT
Duty Cycle 40°C (based on a 10 min. period)| Output Current
100%| 420A
60%| 500A
Welding Current Range| Peak Open Circuit Voltage
5 ÷ 500A| 113Vdc peak
DIMENSION
Weight| Height| Width| Length
17,7 kg| 516 mm| 302 mm| 642 mm
WIRE FEED SPEED RANGE / WIRE DIAMETER
WFS Range| Drive Rolls| Drive roll diameter
1.5 ÷ 22 m/min| 4| Ø37
Solid Wires| Aluminum Wires| Cored Wires
0.8 ÷ 1.6 mm| 1.0 ÷ 1.6 mm| 0.9 ÷ 1.6 mm
OTHERS
Protection Rating| Maximum Gas Pressure
IP23| 0,5 MPa (5 bar)
Operating Temperature| Storage Temperature
from -10°C to +40°C| from -25°C to 55°C
Customer Assistance Policy
The business of The Lincoln Electric Company is manufacturing and selling high quality welding equipment, consumables, and cutting equipment. Our challenge is to meet the needs of our customers and to exceed their expectations. On occasion, purchasers may ask Lincoln Electric for advice or information about their use of our products. We respond to our customers based on the best information in our possession at that time. Lincoln Electric is not in a position to warrant or guarantee such advice, and assumes no liability, with respect to such information or advice. We expressly disclaim any warranty of any kind, including any warranty of fitness for any customer’s particular purpose, with respect to such information or advice. As a matter of practical consideration, we also cannot assume any responsibility for updating or correcting any such information or advice once it has been given, nor does the provision of information or advice create, expand or alter any warranty with respect to the sale of our products
Lincoln Electric is a responsive manufacturer, but the selection and use of
specific products sold by Lincoln Electric is solely within the control of,
and remains the sole responsibility of the customer. Many variables beyond the
control of Lincoln Electric affect the results obtained in applying these
types of fabrication methods and service requirements.
Subject to Change – This information is accurate to the best of our knowledge
at the time of printing. Please refer to
www.lincolnelectric.com for any updated
information.
WEEE
Do not dispose of electrical equipment together with normal waste!
In observance of European Directive 2012/19/EC on Waste Electrical and
Electronic Equipment (WEEE) and its implementation in accordance with national
law, electrical equipment that has reached the end of its life must be
collected separately and returned to an environmentally compatible recycling
facility. As the owner of the equipment, you should get information on
approved collection systems from our local representative.
By applying this European Directive you will protect the environment and human
health!
Spare Parts
Part List reading instructions
- Do not use this part list for a machine if its code number is not listed. Contact the Lincoln Electric Service Department for any code number not listed.
- Use the illustration of assembly page and the table below to determine where the part is located for your particular code machine.
- Use only the parts marked “X” in the column under the heading number called for in the assembly page (# indicate a change in this printing)
First, read the Part List reading instructions above, then refer to the “Spare Part” manual supplied with the machine that contains a picture- descriptive part number cross-reference.
Reach
Communication in accordance with Article 33.1 of Regulation (EC) No 1907/2006 – REACh. Some parts inside this product contain:
Bisphenol A, BPA, EC 201-245-8, CAS 80-05-7
Cadmium, EC 231-152-8, CAS 7440-43-9
Lead, EC 231-100-4, CAS 7439-92-1
Phenol, 4-nonyl-, branched, EC 284-325-5, CAS 84852-15-3 in more than 0,1% w/w
in homogeneous material. These substances are included in the ʺCandidate List
of Substances of Very High Concern for Authorisationʺ of REACh.
Your particular product may contain one or more of the listed substances. Instructions for safe use:
- use according to Manufacturer instructions, wash hands after use;
- keep out of reach of children, do not put in mouth,
- dispose in accordance with local regulations.
Authorized Service Shops Location 09/16
- The purchaser must contact a Lincoln Authorized Service Facility (LASF) about any defect claimed under Lincoln’s warranty period.
- Contact your local Lincoln Sales Representative for assistance in locating a LASF or go to
www.lincolnelectric.com/en-gb/Support/Locator.
Electrical Schematic
Refer to the “Spare Part” manual supplied with the machine.
Accessories
OPTIONS & ACCESSORIES
K14204-1| WIRE FEEDER DRUM QUICK CONNECTOR
K14175-1| GAS FLOW METER KIT
K10095-1-15M| REMOTE CONTROL 6-PINS, 15M
K2909-1| 6-PIN/12-PIN ADAPTER
K14091-1| REMOTE MIG LF 45 PWC300-7M (CS/PP)
E/H-400A-70-5M| ELECTRODE HOLDER 400A/70MM² – 5M
K10158-1| ADAPTER FOR SPOOL TYPE B300
K10158| ADAPTER FOR SPOOL TYPE B300
R-1019-125-1/08R| ADAPTER FOR SPOOL S200
W000010136| FLAIR 600 GOUGING TORCH WITH MOUNTED LEAD 2,5M
COMPATIBLE POWER SOURCES
K14183-1| POWERTEC® i350S
K14184-1| POWERTEC® i420S
K14185-1| POWERTEC® i500S
K14258-1| SPEEDTEC® 400SP
K14259-1| SPEEDTEC® 500SP
K4283-1| FLEXTEC® 350x CONSTRUCTION
K4284-1| FLEXTEC® 350x STANDARD
K3607-2| FLEXTEC® 500x
MIG/MAG TORCHES
W10429-36-3M| LGS2 360 G-3.0M MIG GUN AIR COOLED
W10429-36-4M| LGS2 360 G-4.0M MIG GUN AIR COOLED
W10429-36-5M| LGS2 360 G-5.0M MIG GUN AIR COOLED
W10429-505-3M| LGS2 505 W-3.0M MIG GUN WATER COOLED
W10429-505-4M| LGS2 505 W-4.0M MIG GUN WATER COOLED
W10429-505-5M| LGS2 505 W-5.0M MIG GUN WATER COOLED
PROMIG MAGNUM
W000345072-2| PROMIG MAGNUM 370 3M
W000345073-2| PROMIG MAGNUM 370 4.5M
W000345069-2| PROMIG MAGNUM 400W 3M
W000345070-2| PROMIG MAGNUM 400W 4.5M
W000345075-2| PROMIG MAGNUM 500W 3M
W000345076-2| PROMIG MAGNUM 500W 4.5M
ROLL KIT FOR SOLID WIRES
KP14150-V06/08| ROLL KIT 0.6/0.8VT FI37 4PCS GREEN/BLUE
KP14150-V08/10| ROLL KIT 0.8/1.0VT FI37 4PCS BLUE/RED
KP14150-V10/12| ROLL KIT 1.0/1.2VT FI37 4PCS RED/ORANGE
KP14150-V12/16| ROLL KIT 1.2/1.6VT FI37 4PCS ORANGE/YELL
KP14150-V16/24| ROLL KIT 1.6/2.4VT FI37 4PCS YELL/GREY
KP14150-V09/11| ROLL KIT 0.9/1.1VT FI37 4PCS
KP14150-V14/20| ROLL KIT 1.4/2.0VT FI37 4PCS
ROLL KIT FOR ALUMINIUM WIRES
KP14150-U06/08A| ROLL KIT 0.6/0.8AT FI37 4PCS GREEN/BLUE
KP14150-U08/10A| ROLL KIT 0.8/1.0AT FI37 4PCS BLUE/RED
KP14150-U10/12A| ROLL KIT 1.0/1.2AT FI37 4PCS RED/ORANGE
KP14150-U12/16A| ROLL KIT 1.2/1.6AT FI37 4PCS ORANGE/YELL
KP14150-U16/24A| ROLL KIT 1.6/2.4AT FI37 4PCS YELL/GREY
ROLL KIT FOR CORED WIRES
KP14150-V12/16R| ROLL KIT 1.2/1.6RT FI37 4PCS ORANGE/YELL
KP14150-V14/20R| ROLL KIT 1.4/2.0RT FI37 4PCS
KP14150-V16/24R| ROLL KIT 1.6/2.4RT FI37 4PCS YELL/GREY
KP14150-V09/11R| ROLL KIT 0.9/1.1RT FI37 4PCS
KP14150-V10/12R| ROLL KIT 1.0/1.2RT FI37 4PCS -/ORANGE
WIRE GUIDES
0744-000-318R| WIRE GUIDE SET BLUE Ø0.6-1.6
0744-000-319R| WIRE GUIDE SET RED Ø1.8-2.8
D-1829-066-4R| EURO WIRE GUIDE Ø0.6-1.6
D-1829-066-5R| EURO WIRE GUIDE Ø1.8-2.8
INTERCONNECION CABLES
K14198-PG| CABLE PACK 5PIN G 70MM2 1M
K14198-PG-3M| CABLE PACK 5PIN G 70MM2 3M
K14198-PG-5M| CABLE PACK 5PIN G 70MM2 5M
K14198-PG-10M| CABLE PACK 5PIN G 70MM2 10M
K14198-PG-15M| CABLE PACK 5PIN G 95MM2 15M
K14198-PG-20M| CABLE PACK 5PIN G 95MM2 20M
K14198-PG-25M| CABLE PACK 5PIN G 95MM2 25M
K14198-PG-30M| CABLE PACK 5PIN G 95MM2 30M
K14199-PGW| CABLE PACK 5PIN W 95MM2 1M
K14199-PGW-3M| CABLE PACK 5PIN W 95MM2 3M
K14199-PGW-5M| CABLE PACK 5PIN W 95MM2 5M
K14199-PGW-10M| CABLE PACK 5PIN W 95MM2 10M
K14199-PGW-15M| CABLE PACK 5PIN W 95MM2 15M
K14199-PGW-20M| CABLE PACK 5PIN W 95MM2 20M
K14199-PGW-25M| CABLE PACK 5PIN W 95MM2 25M
K14199-PGW-30M| CABLE PACK 5PIN W 95MM2 30M
Connection configuration
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>