MUST PV3300 TLV Pure Sine Wave Solar Inverter User Manual

September 29, 2024
Must

MUST PV3300 TLV Pure Sine Wave Solar Inverter

The software supports installation on Windows systems. Scan the QR code for download or visit the website for downloading: https://sw.mustpower.com

Scan QR code for manual

WARNING!
This manual contains important instructions for all Inverter/Charger models that shall be followed during installation and maintenance of the inverter.

The following cases are not within the scope of warranty

  1. Out of warranty.
  2. Series number was changed or lost.
  3. Battery capacity was declined or external damaged.
  4. Inverter was damaged caused of transport shift, remissness, ect external factor
  5. Inverter was damaged caused of irresistible natural disasters.
  6. Not in accordance with the electrical power supply conditions or operate environment caused damage.

General Precautions

Before using it, read all instructions and markings:

  1. inverter
  2. battery
  3. user manual

CAUTION:

  1. To reduce risk of injury, charge only lead-acid rechargeable batteries. If customer use flooded batteries, batteries must be maintained regularly. Other battery types may cause damage and injury.
  2. Do not expose it to rain, snow or any type liquids. Inverters are designed for indoor use.
  3. Do not disassemble it. Take it to qualified service center when service or repair is needed.
  4. To prevent the risk of electric shock, disconnect all wiring before attempting any maintenance or cleaning. Only turning off the unit will not reduce the risk.

WARNING:

  1. Provide ventilation from the battery compartment to outdoors. The battery enclosure should be designed to prevent accumulation and concentration of hydrogen gas at the top of the compartment.
  2. NEVER charge a frozen battery and connect such 12V/24V/48V batteries to inverter.
  3. Input/output AC wiring mustn’t be less than 12AWG and not rated for 75 °C or higher. Battery cable mustn’t be rated for 75°C or higher and should be no less than 4AWG /6AWG gauge.
  4. Pay special attention when working with metal tools around batteries. Batteries short-circuiting could cause an explosion.
  5. Read the battery installation and maintenance instructions carefully before operating.

Personnel Precautions

  1. Better to prepare plenty of fresh water and soap nearby in case battery acid contacts skin, clothing or eyes.
  2. Avoid touching eyes while working near batteries.
  3. NEVER smoke or allow a spark or flame near batteries.
  4. Remove personal metal items such as rings, bracelets, necklaces, and watches when working with batteries. Batteries may provide heavy short-circuit current, which would be enough to make metal melt and causes severe burn.
  5. If a remote or automatic generator start system is used, disable the automatic starting circuit or disconnect the generator to prevent accident during servicing

Introduction
This inverter is applicable to different markets demands, it matches different voltage AC 120V/240V, also can set output voltage, frequency, charging voltage, charging current, it’s available to work in split phase power environment.

Features

  • Pure sine wave output
  • Friendly user interface
  • 3 Steps charging
  • MFD (multi-function display)
  • Overload and short-circuit protection
  • Set charging voltage/charging current.
  • Battery low voltage shutdown point can be set to 10/10.5/ll/ll.5/12V
  • Power-save mode
  • Set utility priority/ Battery priority
  • Set utility input wide/narrow range
  • Inverter voltage can be set to 100/110/120
  • Inverter frequency can be set to 50/60Hz
  • Set utility charging on/off switch
  • BOA MPPT charger
  • Acid or Lithium Select
  • WIFI PORT
  • BAT CAN Port

LCD Panel Description

MUST-PV3300-TLV-Pure-Sine-Wave-Solar-Inverter-\(4\)

  1. MENU
  2. UP
  3. DOWN
  4. ENTER
  5. AC LED
  6. INV LED
  7. FAULT
  8. LCD

Back panel printing description:

MUST-PV3300-TLV-Pure-Sine-Wave-Solar-Inverter-\(5\)

  1. Battery-/+
  2. BAT-CAN PORT
  3. REMOTE PORT
  4. AGS
  5. USB
  6. K. INPUT BREAKER
  7. Pl/-/+
  8. K. OUTPUT: HOT! – N lOOVAC/110 VAC/12fNK.
  9. K. OUTPUT: HOT2 – N lOOVAC/110 VAC/12fNK.
  10. K. OUTPUT: HOT! – HOT2 200VAC/220 VAC/24fNK.
  11. K. INPUT: HOT! – HOT2 200VAC/220 VAC/24fNK.
  12. SWITCH ON/OFF
  13. WIFI

Installation
Unpacking and inspection
Before installation, please inspect whole unit. Be sure that nothing inside the package is damaged. You should have received the following items inside of package.

  • User manual X 1
  • Communication cable X 1
  • Battery cables (RED/BLACK) X 2(Optional)

Mounting the Unit

Consider the following points before selecting where to install:

  • Do not mount the inverter on flammable construction materials.
  • Mount on a solid surface.
  • Install this inverter at eye level in order to read the LCD display clearly.
  • For proper air circulation to dissipate heat, require a clearance about 50 cm to the side and 80 cm above and below the unit.
  • The ambient temperature should be between 0’C and 40’C to ensure optimal operation.
  • The recommended installation position is to be adhered to the wall vertically.
  • Be sure to keep other objects and surfaces as shown in the diagram to guarantee sufficient heat dissipation and to have enough space for removing wires.

SUITABLE FOR MOUNTING ON CONCRETE OROTHER NON-COMBUSTIBLE SURFACE ONLY.

MUST-PV3300-TLV-Pure-Sine-Wave-Solar-Inverter-\(6\)

Install the unit by screwing four screws

MUST-PV3300-TLV-Pure-Sine-Wave-Solar-Inverter-\(7\)

DC Wiring Suggestion
It is suggested to keep battery bank as close as possible to inverter. battery cable length lm is suggested. Please find following minimum wire size. If DC cable longer than 1 m, please use thicker battery cables to bear power current going though.

Model Battery VoltageType Wire Type Model Battery Voltage Type Wire Type
lKW 12VDC 6AWG 3KW 24VDC 3AWG
24VDC 6AWG 48VDC 6AWG
l.5KW 12VDC 4AWG 4KW 24VDC 2AWG
24VDC 6AWG 48VDC 4AWG
2KW 12VDC 2AWG 5KW 48VDC 3AWG
24VDC 4AWG 6KW 48VDC 3AWG

Please connect cable size thicker enough, or connect several combined thin cables together to be same strong. Battery bank should be kept close to inverter; The shorter and thicker cables, the better the system performance.

Please follow battery connection steps below:
Assemble battery ring terminal. Connect all battery packs as units requires.

Battery cable and terminal size suggestion:
It’s suggested to connect at least l00Ah capacity battery pack for 1KW-3KW models, at least 200Ah for 4KW-6KW models.

NOTE: Insert the ring terminal of battery cable into inverter to battery connector, make sure the bolts are tightened with torque of 2-3Nm. Pay special attention to battery back and inverter are connected rightly, also ring terminals are tightly screwed to the battery terminals.

WARNING: Shock Hazard
Installation must be performed with care due to high battery voltage in series.

CAUTION!! Do not place anything between the flat part of the inverter terminal and the ring terminal. Otherwise, overheating may occur.

  • Do not apply antioxidant substance on the terminals before terminals are connected tightly.
  • Before making the final DC connection or closing DC breaker/ dis­connecter, be sure positive(+) must be connected to positive(+) and negative(-) must be connected to negative(-).

AC Input/Output Connection
CAUTION!! Before connecting to AC input power source, please install a separate AC breaker between inverter and AC input power source. This will ensure inverter can be disconnected safely during maintenance and fully protected from over current of AC input.

  • Please don’t connect the output wring to “Grid” terminal or connect the grid wring to the “Load” terminal. WARNING! All wiring must be performed by a qualified personnel.

WARNING! It’s very important to use appropriate cable for Grid connection for system safety and efficient operation. To reduce injury risk, please use the proper suggested cable size as below.

AC Wiring
We recommend using 10-16AWG wire to connect AC terminal block.
There are 3 different ways to connect AC wire to terminal block. All wirings are CE compliant, call our tech support if you are not sure about how to wire any part of your inverter.
Suggested cable requirement for AC wires

Model Gauge Torque Value
1-3KW 12-14AWG 1.2-1.6Nm
4-6KW 10-12AWG 1.4-1.6Nm

Please follow steps below to implement Load/Grid connection:

  • Before Load/Grid connection, be sure to open DC protector first.
  • Remove insulation sleeve 10mm for six conductors. And shorten phase Land neutral conductor N 3 mm.
  • Insert grid wires according to polarities indicated on terminal block and tighten terminal screws. Be Sure to connect PE protective conductor( )first.

AC INPUT Connection
➔Ground (yellow-green)
HOT1 (brown or black)
HOT2 (brown or black)

WARNING:
Be sure that AC power source is disconnected before hard-wire it to the unit.

  • Then, insert Load wires according to polarities indicated on terminal block and tighten terminal screws. Be sure to connect PE protective conductor( ****)first

AC OUTPUT Connection
➔Ground (yellow-green)
HOT1 ➔ LINE {brown or black)
N ➔ Neutral {blue or white)
HOT2 ➔ LINE {brown or black)

MUST-PV3300-TLV-Pure-Sine-Wave-Solar-Inverter-\(11\)

  • Make sure the wires are securely connected

CAUTION: Appliances such as air conditioner are required at least 2-3 minutes to restart because it’s required to have enough time to balance refrigerant gas inside of circuits. If a power shortage occurs and recovers in a short time, it will cause damage to your connected appliances. To prevent this kind of damage, please check manufacturer of air conditioner if it’s equipped with time-delay function before installation. Otherwise, this inverter will be triggered overload fault and cut off output to protect your appliance but sometimes it still causes internal damage to the air conditioner.

PV Module Selection:
Please follow below steps to implement PV module connection:

  1. Remove insulation sleeve 10 mm for positive and negative conductors
  2. Check correct polarity of connection cable from PV modules and PV input connectors. Then, connect positive pole (+)of connection cable to positive pole (+) of PV input connector. Connect negative pole (-) of connection cable to negative pole (-) of PV input connector.
  3. Make sure the wires are securely connected.

MUST-PV3300-TLV-Pure-Sine-Wave-Solar-Inverter-\(13\)

Operation

MUST-PV3300-TLV-Pure-Sine-Wave-Solar-Inverter-\(14\)

Operation key instructions:

  • Switch button to control the machine On and off.
  • There are four buttons: MENU, UP, DOWN, ENTER.
  • Via UP and DOWN can check the various parameters display.
  • Long press MENU to enter the setting menu page, MENU and ENTER turn over the menu page, UP and DOWN to set the parameters. After setting, long press ENTER 2s to exit, except the inverter frequency and inverter voltage parameters, The setting parameters are not saved to the EEPROM. The EEPROM is saved only when the parameters are normally set. (To ensure that the parameters can be successfully saved, so every time after setting the parameters need restart the machine).

Fault Mode

LED instruction

LED LED state information
LED AC(green) Off No AC input
On AC normal
Blink AC over range
LED Inv(yellow)
Off
On Inverter mode
LED Fault(red) Off normal
On fault
Blink caution

BUZZER instruction

Buzzer state information
Buzzer off normal
Buzzer beep caution
Buzzer on fault

Setting key instructions

MUST-PV3300-TLV-Pure-Sine-Wave-Solar-Inverter-\(15\) MUST-PV3300-TLV-Pure-Sine-Wave-Solar-
Inverter-\(16\)

MUST-PV3300-TLV-Pure-Sine-Wave-Solar-Inverter-\(17\)

LCD display:

MUST-PV3300-TLV-Pure-Sine-Wave-Solar-Inverter-\(18\)

Operating mode description

MUST-PV3300-TLV-Pure-Sine-Wave-Solar-Inverter-33

AGS function

AGS function information
The AGS function is that the inverter will start the generator automatically via the dry contact when the battery is low voltage.

Note:
The generator must have dry contact function.
If you connect AC grid and Generator to Inverter input at the same time, the interlock device should be installed between generator output and inverter input. (To ensure the utility and generator will not provide power to inverter at the same time. It doesn’t need to be installed if only connect generator).

MUST-PV3300-TLV-Pure-Sine-Wave-Solar-Inverter-\(23\)

Dry contact operating voltage

Set Low Shutdown Voltage Operation Voltage Restoring Voltage
10V/20V/40V DC< l0.5V/21V/42V DC>13.5V/27V/54V
10.5V/21V/42V DC<l1V/22V/44V DC>13.5V/27V/54V
11V/22V/44V DC< 11.5V/23V/46V DC>13.5V/27V/54V
11.5V/23V/46V DC< 12V/24V/48V DC>13.5V/27V/54V
12V/24V/48V DC< 12.5V/25V/50V DC>13.5V/27V/54V

That is when the dry contact is engaged at DC<set low shutdown point+ 0.SV (battery low voltage warning point), at DC> 13.SV. (12V model)

Inverter Fan

**** DC fan:only full speed check the signal| Start inverter| Fullspeed| After start inverter| Half speed
---|---|---|---|---
Inverter T>50’C| Fullspeed| Inverter T<40’C| Half speed
Load>50%| Fullspeed| Load<45%| Half speed
4-6KW AC fan:dont check the signal| Fullspeed

Unit charge function:
Inverter & MPPT controller: solar energy not enough, inverter will charge remain current.

Inverter set charge current Solar charge current Inverter charge current
example:40A 0A 40A
l0A 30A
>40A 0A

UTI/SBU function:

Set Convert condition Convert stage specification
until AC cut off or over the AC range AC model to DC model

SBU

| DC<20 set page parameter| DC model to AC model
PV>l5V/,12,) & DC>21set page parameter and lmin| AC model to DC model

BTS-CAN function:

  • BMS communication connection,confirm that the setting content is correct,and the wiring is not abnormal, the inverter matching lithium battery communication protocol confirm that the setting is normal.

MUST-PV3300-TLV-Pure-Sine-Wave-Solar-Inverter-\(24\)

Port Lithium battery Inverter
CAN communication port difinition PIN 1 NC(Empty)
PIN 2 NC(Empty) PIN 2
PIN 3 NC(Empty) PIN 3
PIN 4 CANL PIN 4
PIN 5 CANH PIN 5
PIN 6 NC(Empty) PIN 6
PIN 7 NC(Empty)
PIN 8 NC(Empty)

MUST-PV3300-TLV-Pure-Sine-Wave-Solar-Inverter-\(25\)

Communication

Upper Computer Monitoring directions:

  • Monitoring software: This software supports the communication function for various models of our company. The software will searching the COM Port and inverter model automatically.

The operation steps are as follows:
Connect the Inverter and Computer. connect the inverter with a communication cable to the computer with usb communication port.

MUST-PV3300-TLV-Pure-Sine-Wave-Solar-Inverter-\(26\)

Install the software: Solar Power Monitor

  1. Put the CD in the computer CD driver, install the software Solar Power Monitor (Proper install following the steps)
  2. Choose Solar Power Monitor. exe and install.
  3. 0pen the PowerMonitor, turn on the machine.
  4. The SolarPowerMonitor will auto scan communication port. MUST-PV3300-TLV-Pure-Sine-Wave-Solar-Inverter-\(27\)
  5. Wait for a moment, Power Monitor will work normally. MUST-PV3300-TLV-Pure-Sine-Wave-Solar-Inverter-\(28\)

Monitor software function operation
Specific function Operations of the monitoring software, please refering to the HELP docs after the connection is successful.

Specification

Inverter Mode Specification

Model| 1012i1024I1512i1524I2012i2024I3024I3048I4024I4048I             5048 6048
---|---
Rated power(W)| lKW| l.5KW         2KW| 3KW| 4KW| 5KW          6KW
Power Factor| 1
Waveform| Pure sine wave
Output voltage RMS| 100V/1 l0V / 120VAC(200V/220V/240VAC)± 10%
Output frequency| 50HZ or 60HZ ( ±0.3HZ)
Inverter efficiency(peak)| >80%
**** Overload| 1000/o<Load< 110% (alarm 5min then stop output and fault code 07) 110%<Load<125% (alarm 60s then stop output and fault code 07)
Load>125% (alarm 10s then stop output and fault code 07)
Surge rating| 3000VA  I| 4500VA I    6000VA| 9000VA I 12000VA| 15000VA I 15000VA
Capable of starting

electric motor

| lP| 1.5P| 1.5P| 2P| 3P
Battery voltage| 12VDC/24VDC| 24VDC/48VDC| 48VDC
Minimum start voltage| 11VDC/22VDC/44VDC
Low battery cut off| (low voltage fault code04) (10/10.5/ll/ll.5/12V) for 12V model (20/21/22/23/24V) for 24V model
(40/42/44/46/48V) for 48v model
Low battery alarm| Add 0.5V/battery: (low battery alarm one second one time) (10/10.5/ll/ll.5/12V) +0.5Vdc for 12V model (20/21/22/23/24V) +1Vdc for 24v model
(40/42/44/46/48V) +2Vdc for 48v model
**** High voltage alarm| Add + 1V/battery: (high voltage one second one time/after 30s fault 03)
(12-14.5V) + 1V for 12V model
(24-29V) + 2V for 24v model (48-58V) + 4V for 48v model
Save mode| Load:-,40W(110V)/80W(220V)

AC Mode Specification
AC parameter

Input waveform Pure sine wave
Nominal input voltage 200Vac / 220Vac / 240Vac
Max input voltage 270Vac MAX
Input frequency 50HZ/60HZ (auto sensing)
Output waveform Same as input waveform
Overload protection Breaker + software protection
Output short circuit Breaker+ software protection
Efficiency(AC mode) >95%® load, full battery)
Transfer time AC TO DC 15ms(Typical)
Transfer time DC TO AC 15ms(Typical)

AC input voltage range: ( ±SV)

model range Low cutoff Low recover High cutoff High recover
220V narrow AC<180V AC>190V AC>270V AC<265V
F<40HZ F>45 HZ F>70HZ F<65HZ
wide AC<140V AC>l5 0V AC>270V AC<265V
F<40HZ F>45 HZ F>70HZ F<65 HZ

Charge Mode Specifications
Max charge current: ( ±5A)

model lK 1.5K 2K 3K 4K 5K 6K
12V 30A 45A 60A
24V 20A 25A 30A 40A 60A
48V 20A 30A 35A 40A

Min charge current 10A. change by every 5A.

Charge mode AC range:

Setting Low voltage Charge mode recover Charge mode
220V AC wide range AC>265V Stop charge AC<260V Charge recover
AC<l55V Stop charge AC>160V Charge recover

40<F<70HZ charge

Solar charger(MPPT controller) electrical specification

Type MPPT-80A
Nominal system voltage 12V/24/48V(auto detection);
Maximum charge current 80A±4A
Battery voltage 12V
Maximum solar input voltage 100±2V
PV array MPPT voltage range 15-95V
Maximum input power 1250W
Charging stages Bulk, absorption, float
Over charging voltage l5.5V/30.0V/45.0V /60 . 0V
Over charging comeback voltage 14.5V/29.5V/44.5V /59.0V
Battery defect voltage 10.0V /17.0V/25.5V/34.0V

Charge mode:

Charge current adjustable| Charge current adjustable: 10A min (adjust by every 5A)
---|---
Battery voltage| 10-14.5Vdc/20-29Vdc/40-58Vdc
Short circuit protection| breaker
Over charge protection| Bat V charge voltage+lV/battery,ls 1 time for 30s then alarm 03
rule| Boost CC -Boost CV – Boost FV
Charging algorithm for lead acid battery(Lithium battery charging curveThe charging current in the fioat charging stage is 10A)| MUST-PV3300-TLV-
Pure-Sine-Wave-Solar-Inverter-\(29\)
---|---
Charging algorithm for Lithium battery(Lithium battery charging curveThe charging current in the fioat charging stage is 10A)| MUST-PV3300-TLV-Pure-
Sine-Wave-Solar-Inverter-\(30\)

LCD display instruction

When inverter alarm, even it back to recovery mode. We must restart inverter to clear fault.

MUST-PV3300-TLV-Pure-Sine-Wave-Solar-Inverter-34

MPPT controller warning:

MUST-PV3300-TLV-Pure-Sine-Wave-Solar-Inverter-35

GUARANTEE CERTIFICATE

  • Serial No.: 

MUST-PV3300-TLV-Pure-Sine-Wave-Solar-Inverter-\(31\)

  • Serial No.:

MUST-PV3300-TLV-Pure-Sine-Wave-Solar-Inverter-\(32\)

Documents / Resources

| MUST PV3300 TLV Pure Sine Wave Solar Inverter [pdf] User Manual
PV3300 TLV, PV3300 TLV, PV3300 TLV Pure Sine Wave Solar Inverter, PV3300 TLV, Pure Sine Wave Solar Inverter, Sine Wave Solar Inverter, Wave Solar Inverter, Solar Inverter, Inverter
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals