12VDC 300W Class 2 Constant Voltage LED Driver
Model: MD-012-300VWJ2V2
Images
PRECAUTIONS BEFORE INSTALLING
- Read all instructions before installation. To be sold with instructions.
- Only qualified personnel should install the unit.
- Installation must comply with the National Electrical Code (Article 450) and Canadian Electrical Code.
- Ensure the unit has the proper input/output voltage and output wattage for your application.
- Check the wire markings to ensure they match the wiring diagram on this installation guide.
- Turn off power at breaker before starting.
INSTALLATION GUIDELINES
-
The driver must be installed in a well-ventilated area free from explosives gases and vapors. Proper operation requires for free ow of air. Do not install inside a cabinet smaller than 12 W x 12 H x 15 L inches. If you are installing multiple drivers, keep a minimum space of 5″ (127mm) between each driver. For Indoor or Outdoor use.
-
Operate only within specified ambient temperature range of 4°F (-20°C) to 104°F (40°C). Operating at cooler surrounding air temperature will extend driver life.
-
Do not overload. Total wattage of all LED fixtures used must not exceed the 300 watt rating of this power supply. Maximum of 48 watt in each output for continuous use.
-
Route and secure wires so they will not be pinched or damaged.
-
All wiring must be in accordance with NEC/CEC, low voltage Class 2 circuit. For wire runs inside of walls, use properly certified CL2 or better cabling and
appropriate mounting hardware. If you are unclear as to how to install and wire this product, contact a qualified licensed electrician. Failure to install this device properly may result in electrical shock or fire. -
Do not install Class 2 low voltage wiring in the same run(s) as AC main power.
MOUNTING
Select a suitable location capable of supporting the weight of the transformer. Use the four keyholes on the transformer case. Screw cover closed. Mount the unit at a height greater than 1ft (30cm) from the ground.
Image
If used outdoors, the knockouts must point downward
Image
5″(127mm) min spacing between drivers
INPUT CONNECTIONS / GROUNDING
-
Remove the wiring cover (2 screws). Remove the wiring compartment knockout and install strain reliefs (not included). With power turned off at the breaker, route the input wires. Connect one wire to black(L) and one wire to white(N) to the corresponding pigtail wire.
-
For all wire connections use only UL/CSA listed wire nuts or wago connectors of suitable size and type.
-
The Driver case MUST be grounded in accordance with the NEC/CEC. Connect the ground wire to the driver green wire.
-
Use 3/8″ (1/2″ KO) cable connectors (not included) to secure wire.
-
If used outdoor, must have knockouts point downwards. Use only outdoor rated
UL/CSA listed strain relief (water tight). -
Maximum of 12AWG through branch circuit conductor suitable for 105°C (221°F) permitted in box.
Image
Knockouts Input
Install strain reliefs (Note: Use water tight strain relief for outdoor location installation)
OUTPUT CONNECTIONS (LOW VOLTAGE)
- Connect the wires of the light fixture to the driver wires – positive to the red(+) wire and negative to black(-) wire.
- Measure the output voltage for proper voltage to LED fixture.
- WARNING – Do not interconnect output terminations. Risk of Fire or Electric Shock.
- After all wiring completion, screw in wiring cover.
Image
Use appropriate UL/CSA listed wire nuts or wago connectors (not included) to
connect wires
Image
Input
Output
Green (G)
White (N)
Black (L)
Red (V+)
Black (V-)
CONNECTION DIAGRAM
NOTE: Do not use for Dimming
Image
text
WARNING
- Prevent reverse polarity.
- The LED Driver is not to be repaired. Do not use if it is damaged or defective.
- Installation involves special wiring methods to run wiring through a building structure. Consult a qualified licensed electrician.
TROUBLESHOOTING
Do not exceed 48 watts of continuous load in each output. Note the wattage information on the item (strip label) that is being powered. If wattage or amperage information is not available or unknown, do not use. Power supply may be very warm if overloaded and will damage the unit (void limited warranty).
This device complies with FCC 47 CFR Part 15, Part B. Operation is subject to the following two conditions: (1)May not cause harmful interference, 2)Must accept any interference received, including interference that may cause undesired operation.
LED World Inc. | #130 10615 48 ST SE | CALGARY, AB T2C 2B7 | CANADA | Version
1.0 03/28/24
Copyright © 2024 LED WORLD INC™. All Rights Reserved. We are not responsible
for errors or omissions. Product and specifications subject to change without
notice. Registered trademarks are owned by their respective registers, or
licensee(s).
References
- LED World Canada - A Commercial LED lighting supplier
- LED World Lighting - A Commercial LED lighting supplier
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>