SAFETY
1.1. ELECTRICAL SAFETY
‰ WARNING! It is the user’s responsibility to check the following:
Check all electrical equipment and appliances to ensure that they are safe
before using. Inspect power supply leads, plugs and all electrical connections
for wear and damage. Sealey recommend that an RCD (Residual Current Device) is
used with all electrical products.
Electrical safety information. It is important that the following information
is read and understood:
Ensure that the insulation on all cables and on the appliance is safe before
connecting it to the power supply.
Regularly inspect power supply cables and plugs for wear or damage and check
all connections to ensure that they are secure.
Important : Ensure that the voltage rating on the appliance suits the
power supply to be used and that the plug is fitted with the correct fuse.
DO NOT pull or carry the appliance by the power cable.
DO NOT pull the plug from the socket by the cable.
DO NOT use worn or damaged cables, plugs or connectors. Ensure that any faulty
item is repaired or is replaced immediately by a qualified electrician.
If the cable or plug is damaged during use, switch off the electricity supply
and remove from use. Ensure that repairs are carried out by a qualified
electrician.
1.2. GENERAL SAFETY
WARNING! Ensure Health & Safety, government and local authority
regulations relating to the transfer of diesel are adhered to when using this
equipment. Familiarise yourself with the application, limitations and specific
hazards peculiar to the pump.
WARNING! Disconnect pump from the mains power before changing accessories,
servicing or performing any maintenance.
Maintain pump in good condition (use authorised service agent). Drain before
dismantling.
Maintain correct balance and footing. Ensure the floor is not slippery and
wear non-slip shoes.
Ensure the transfer area is free of clutter and has adequate lighting.
Keep children and unauthorised persons away from the working area.
Replace/repair damaged parts. Use genuine parts. Unauthorised parts are
dangerous and will invalidate warranty.
DO NOT use the pump without the delivery nozzle attached.
DO NOT start or stop the pump by switching on or off at the mains power
supply.
DO NOT operate the unit with wet hands. We recommend the use of gloves and
goggles.
It is installer’s responsibility to ensure all supply pipes, fixtures and
fittings are adequate for the safe flow of diesel fuel.
DO NOT use this pump for transferring the following liquids; Acetone, Benzene,
Cresol, Ethyl, Phenol, Methyl ethyl, Concentrated caustic soda liquid, Nitric
acid, Hydrochloric acid, Sulphuric-acid, thinner or solvents, Etc.
DO NOT use for concentrated acids.
Only use on applicable liquids written on the specifications. Make sure to use
the pump on even surface.
DO NOT use when the cable and plug is damaged or if plug is loose on outlet.
Keep the power supply adapter out of direct sunlight, water vapour, soft coal,
dust, and damp air etc.
DO NOT touch and operate any plug or power supply units with wet hands.
Make sure the pump is tightly secured to the drum (tank) before turning the
pump on.
DO NOT refuel directly while the vehicle or equipment is turned on.
DO NOT leave the pump unattended.
DO NOT allow children to operate the product without adult supervision. Wash
and clean out the outlet, plug, and plug blades regularly.
If the power supply adapter falls into the water, pull the plug out and DO NOT
reuse it.
Make sure to hold on the plug and pull it out from the outlet. (DO NOT pull on
the cable).
DO NOT get power cable damaged, bent, pulled, twisted, or bound.
DO NOT get the plug and outlet wet.
When you hand it over to another person, be sure to give them the
instructions too.
DO NOT use deteriorated or contaminated liquids and fuels.
DO NOT use this pump for hot liquids above 40°C (104°F ).
Use it in a well-ventilated area since the power supply adaptor becomes a
little hot.
DO NOT run the pump ‘dry’ or let the pump idle without transferring.
DO NOT run the pump for longer than 15 minutes.
Make sure to turn on the power after using the pump.
Make sure to remove any left-over liquid in the discharge hose after each use.
After using the pump, DO NOT keep it on its side or upside down.
DO NOT alter or disassemble the pump.
DO NOT shock the pump and power supply adapter. Also DO NOT strain the power
cable.
When cleaning up the pump, DO NOT use thinner, benzene, organic solvent, or
glass cleaners.
INTRODUCTION
Electric drum mounted pump designed for pumping diesel, AdBlue®, antifreeze, detergents, water and light oils up to a viscosity of 100cst. Fitted with built-in fuse for protection, with a silenced motor keeping noise to a minimum. Telescopic suction tube features a stainless steel filter at the base of the tube, preventing foreign matter from entering the motor. Pump housing features a convenient holder for storing the dispensing nozzle. Includes 230V mains adaptor and 12V battery clips allowing user to operate unit with whichever supply is available. Supplied with a 2”BSP adaptor, 2m hose and manual dispensing nozzle with spout.
SPECIFICATION
Model No:…………………………………………….. TP6818.V2
Current: …………………………………………………………….. 3A
Duty Cycle:………………………………… 15min on, 30min off
Flow Rate:…………………………………………………. 16L/min
Fuse Rating:………………………………………………………. 5A
Power: ………………………………………………………….16.8W
OPERATION
4.1. Adjust the length of the suction pipe to fit the drum, (fig.2).
4.2. Insert the suction pipe into the drum (fig.2).
4.3. Tighten the drum bung adapter (fig.3).
4.4. Connect power supply to the pump (fig.4).
4.5. Pull out the nozzle from the nozzle holder (fig.5).
4.6. Place the nozzle into the receiving container (fig.6).
4.7. Switch on the pump by moving the switch up (fig.7).
4.8. Pull the nozzle lever and start supplying the liquid (fig.8).
4.9. Release the leaver when the liquid supply is complete (fig.9).
4.10. Switch off the pump by moving the switch down (fig.10).
4.11. Lift the nozzle up and pull the lever (fig.11).
4.12. Drain the liquid in the hose back into the drum (fig.12).
4.13. Insert nozzle into the nozzle holder for storage (fig.13).
MAINTENANCE
5.1. Switch off and remove power supply before any maintenance.
5.2. Clean the pump and inspect all piping connections for leaks.
5.3. Clean the filter (refer to parts list) by removing end cap remove filter
and clean.
5.4. Store in a dry, childproof location.
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools,
accessories and packaging should be sorted, taken to a recycling centre and
disposed of in a manner which is compatible with the environment. When the
product be comes completely unserviceable and requires disposal, drain any
fluids (if applicable) into approved containers and dispose of the product and
fluids according to local regulations.
WEEE REGULATIONS
Dispose of this product at the end of its working life in compliance with the
EU Directive on Waste Electrical and Electronic Equipment (WEEE). When the
product is no longer required, it must be disposed of in an environmentally
protective way. Contact your local solid waste authority for recycling
information.
Note: It is our policy to continually improve products and as such we
reserve the right to alter data, specifications and component parts without
prior notice. Please note that other versions of this product are available.
If you require documentation for alternative versions, please email or call
our technical team on technical@sealey.co.uk
or 01284 757505.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is