Specifications:

  • Compatibility: All OS that supports USB HID
    Keyboards

  • LED Status Indicators: Num Lock, Caps Lock,
    Scroll Lock

  • Temperature Range: N/A

  • Supply Voltage: 5 V +/-10% through USB

  • Current Consumption: Max. 100 mA (USB: low
    power device)

  • Connector: USB Type A

  • Dimensions: Approx. 14.37×5.47×0.67in /
    365x139x17mm

  • Interface: USB 2.0 FS

  • Key Switch Technology: Scissor Balancing key
    guidance with protected contact system

  • Key Travel: Approx. 2 +/- 0.5mm

  • Key Actuation Force: Approx. 65g

  • Weight: Approx. 1.3lb / 600g (without
    packaging)

  • Touchpad: integrated into the keyboard,
    approx. 74×37 mm

  • Agency Approvals / Tests: CE, RoHS, EN
    60601-1-2:2015*

Product Usage Instructions:

CLEAN Function Activation/Deactivation:

To activate/deactivate the CLEAN function, use the key
combination Fn + Shift (Clean on/off).

The mode ‘CLEAN function active’ is indicated by flashing all
status LEDs. During this mode, all key entries are suppressed to
allow cleaning or disinfection of the keyboard.

The ‘CLEAN function active’ mode ends automatically after a
timeout of 5 minutes or by using the key combination again.

Cleaning and Disinfection:

Please follow the instructions provided by your authorities for
standard disinfection of surfaces for reprocessing of the
keyboard.

Frequently Asked Questions (FAQ):

Usage of Medical Protective Gloves:

Nitrile gloves reduce the risk of allergic reactions and help
prevent discoloration caused by latex wear.

“`

Instructions and Safety Information
AK-C7412F-GUS series
The corded keyboard AK-C7412 is a high quality, highly reliable hygiene keyboard with integrated touchpad. It is particularly designed for the use at hospitals and by practitioners. The keyboard is sealed with a silicone membrane. The CLEAN function avoids sending keystrokes to your PC during cleaning/disinfection. Please follow the instructions provided by your authorities for standard disinfection of surfaces for reprocessing of the keyboard.

Delivery Content:
1x Corded Keyboard 1x User Manual

Manufacturer:
Cherry Digital Health GmbH Cherrystraße 2 D-91275 Auerbach/OPf.

Web: www.cherry.de Tel: +49 (0) 9643-2061-100

Legal information: The product complies with the Directive EMC 2014/30/EU. The full text of the EU declaration of conformity is available at the following internet addresses: http://www.cherry.de/compliance
Electrical and electronic equipment (EEE) is marked with the symbol of the crossed-out wheeled bin indicating the requirement not to dispose of waste electrical and electronic equipment (WEEE) as unsorted municipal waste and to collect such WEEE separately. Final users of WEEE from private households shall be able to return WEEE as per EU country local regulations into established collection facilities free of charge. Please consult your municipal waste department for detailed advice on separate collection of WEEE.
The packaging material used with this product is identified as PAP-20 and LDPE-04. Please follow the rules of your local community on collection of used packaging.

Frequently Asked Questions (FAQ):
Usage of Medical Protective Gloves! Nitrile gloves reduce the risk of allergic reactions and help prevent discoloration caused by latex wear.
How to activate/deactivate the CLEAN function?
The key combination “Fn” + “Shift (Clean on/off)” activates and deactivates the CLEAN function.
The mode CLEAN function active’ is indicated by flashing all status LEDs. During this mode the user can wipe disinfect or clean the keyboard and all key entries are suppressed. The modeCLEAN function active’ ends automatically after a timeout of 5 minutes or by key combination

Specification:

Compatibility

All OS that supports USB HID Keyboards

LED Status Indicators

Num Lock, Caps Lock, Scroll Lock

Temperature Range

Storage: 4 °F to 140 °F / -20 °C to +60 °C

Operation: 32 °F to 122 °F / 0 °C to +50 °C

Supply Voltage

5 V +/-10% through USB

Current Consumption

Max. 100 mA (USB: low power device)

Connector

USB Type A

Dimensions

Approx. 14.37×5.47.0.67in / 365x139x17mm

Interface

USB 2.0 FS

Key Switch Technology

Scissor Balancing key guidance with

protected contact system

Key Travel

Approx. 2 +/- 0,5mm

Key Actuation Force

Approx. 65g

Weight

Appr. 1.3lb / 600g (without packaging)

Touchpad

integrated into the keyboard, approx. 74×37 mm

Agency Approvals / Tests

CE, RoHS, EN 60601-1-2:2015*

*No Medical Device acc.to Regulation (EU) 2017/745

All rights reserved. Copy or duplication, except for personal use, not permissible without specific prior written consent by Cherry Digital Health GmbH. Contents are subject to change without notice. Errors excepted. Copyright by Cherry
Digital Health GmbH. Version 20240628

Bedienungsanleitung und Sicherheitsinformationen
AK-C7412F-GUS Serie

Die kabelgebundene AK-C7412 ist eine hochwertige und zuverlässige HygieneTastatur mit integriertem Touchpad. Sie ist besonders für den Einsatz in Krankenhäusern und Arztpraxen geeignet. Die Tastatur wird durch eine SilikonUmhüllung geschützt.
Die ,,CLEAN Funktion” sorgt dafür, dass die Tastatur während der Reinigung/Desinfektion keine Tasteneingaben an den Computer sendet. Die Routine-Desinfektion folgt den Richtlinien der Deutschen Gesellschaft für Hygiene und Mikrobiologie. Für die Wischdesinfektion können Desinfektionsmittel nach den Vorgaben des Verbunds für angewandte Hygiene e.V. (,,VAH-Liste”) eingesetzt werden.

Lieferumfang:
1x Kabeltastatur 1x Bedienungsanleitung

Hersteller:
Cherry Digital Health GmbH Cherrystraße 2 D-91275 Auerbach/OPf.

Web: www.cherry.de Telefon: +49 (0) 9643-2061-100

Rechtliche Hinweise: Das Produkt entspricht der Richtlinie EMV 2014/30/EU. Der vollständige Text der EU-Konformitätserklärung ist unter folgender Internetadresse verfügbar: http://www.cherry.de/compliance
Das auf Elektro- und Elektronikgeräten regelmäßig abgebildete Symbol einer durchgestrichenen Mülltonne weist darauf hin, dass das jeweilige Gerät am Ende seiner Lebensdauer getrennt vom unsortierten Siedlungsabfall zu erfassen ist. Besitzer von Altgeräten aus privaten Haushalten können diese bei den Sammelstellen der öffentlich-rechtlichen Entsorgungsträger oder bei den von Herstellern oder Vertreibern im Sinne des ElektroG eingerichteten Rücknahmestellen unentgeltlich abgeben.
Das verwendete Verpackungsmaterial wird durch folgende Nummern und Abkürzungen beschrieben: PAP-20 und LDPE-04. Bitte entsorgen Sie Verpackungsmaterial gemäß den Richtlinien Ihres Entsorgungssystems.

Häufig gestellte Fragen (FAQ):
Verwendung von medizinischen Handschuhen! Nitrilhandschuhe verringern das Risiko allergischer Reaktionen und vermeiden Verfärbungen durch den Abrieb von Latex.
Wie aktiviere/deaktiviere ich die CLEAN-Funktion? Die Tastenkombination “Fn” + “Shift (Clean on/off)” aktiviert und deaktiviert die CLEAN-Funktion. Der Modus “CLEAN Funktion aktiv” wird durch gleichzeitiges Blinken aller Status LEDs angezeigt. In diesem Modus kann der Nutzer die Tastatur reinigen oder desinfizieren; Tastenbetätigungen werden unterdrückt. Der Modus “CLEAN- Funktion aktiv” endet automatisch nach 5 Minuten oder über Betätigung der Tastenkombination.

Technische Daten:

Kompatibilität

Alle Betriebssysteme, die eine Standard USB

Tastatur unterstützen

LED-Statusanzeigen

Num Lock, Caps Lock, Scroll Lock

Temperaturbereich

Lagerung: -20 °C bis +60 °C

Betrieb: 0 °C bis +50 °

Spannungsversorgung

5 V +/-10 % (USB-Schnittstelle)

Stromverbrauch

Max. 100 mA (USB: low power device)

Stecker

USB Typ A

Abmessungen

Ca. 365x139x17mm

Schnittstelle

USB 2.0 FS

Tastentechnologie

Scherentechnologie, Tastenführung mit

geschlossenem Kontaktsystem

Tastenhub

Ca. 2 +/- 0,5mm

Tasten-Betätigungskraft

Ca. 65g

Gewicht

Ca. 600g (ohne Verpackung)

Touchpad

In die Tastatur integriert, ca. 74x37mm

Zulassungen

CE, RoHS, EN 60601-1-2:2015*

  • Kein Medizinprodukt nach Verordnung (EU) 2017/745

Alle Urheberrechte vorbehalten. Kopie oder Vervielfältigung, außer zum persönlichen Gebrauch, ohne vorherige, schriftliche Zustimmung nicht gestattet. Änderungen und Irrtümer vorbehalten. Version 20240628

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals