Product Information

General Specifications

  • Model Series: MITRA, ARUNA, CERES, GAIA, ILLONA, NORA, SENNA,
    THERMA

  • Model: FH25/FH25S

  • Digital room thermostat designed for underfloor heating and
    cooling system

  • Features:

    • Sensitive Temperature Measurement
    • Hysteresis Adjustment
    • Temperature Calibration
    • ON/OFF Control
    • Wired connection
    • Floor sensor temperature setting
    • Heating/Cooling Modes

Specifications

  • Dimensions (H / L / W): Not specified
  • Operating Current: Not specified
  • Relay NO Switching Current: Not specified
  • Temperature Measurement Accuracy: Not specified
  • Operating Sensitivity: Not specified
  • Operating Temperature Range: Not specified
  • Operating Temperature Storage Temperature: Not specified

Product Usage Instructions

Room Thermostat Placement

Place the Room Thermostat in a frequently used room in your
living space, like the hall or living room. Avoid areas with high
air circulation, near heating units, or in direct sunlight.
Recommended height is 150 cm from the floor.

Temperature Calibration

Calibrate the Room Thermostat based on the temperature in your
living space. Press and hold the button for 3 seconds while the
device is off. Follow on-screen instructions to calibrate.

Heating/Cooling Modes

To switch between heating and cooling modes:

  1. Turn off the device.
  2. Press and hold the button for 3 seconds.
  3. Adjust settings to choose heating or cooling mode.
  4. Save settings by turning off the device.

FAQ

Q: How do I know if the heating or cooling unit is

working?

A: Check the Heating or Cooling Indicator on the Room
Thermostat. Blinking indicates working, steady light indicates not
working.

“`

ENGLISH

UNDERFLOOR HEATING THERMOSTAT
generallife.com.tr SERIES: MITRA, ARUNA, CERES, GAIA, ILLONA, NORA, SENNA, THERMA

FH25/FH25S USER MANUAL

GENERAL SPECIFICATIONS

FH25/FH25S is a digital room thermostat designed for underfloor

heating and cooling system. The user can get more comfortable and

economic heating/cooling by adjusting the room thermostat with the

required temperature.

Sensitive Temperature Measurement

Hysteresis Adjustment

Temperature Calibration

ON/OFF Control

Wired connection

Floor sensor temperature setting

Heating/Cooling Modes

FH25/FH25S AND EQUIPMENTS Room Thermostat

Dowels and Screws

TECHNICAL DATA Dimensions ( H / L / W ) Operating Current Relay NO Switching Current
Temperature Measurement Accuracy Operating Sensitivity Operating Temperature Range Operating Temperature Storage Temperature
ROOM THERMOSTAT

85.7mm / 85.7mm / 33.5mm 230V AC 7A (240VAC ­ Resistive load) 10A (120VAC ­ Resistive load) 0.1oC
(-2.0oC) ­ (+2.0oC) (5oC) ­ (30oC) (-10oC) ­ (+50oC) (-20oC) ­ (+60oC)

1

2

3

4

5

1

Room Temperature

2

Underfloor Heating Temperature*

3

Set Temperature

Heating Indicator

– If the Heating Indicator is blinking, the heating unit is

4

working.

– If the Heating Indicator lights up constantly, the heating

unit is not working.

Cooling Indicator

– If the Cooling Indicator is blinking, the cooling unit is

5

working.

– If the Cooling Indicator is steady, the cooling unit is not

working.

  • External floor sensor is only active when it is connected.

ROOM THERMOSTAT PLACEMENT Place your Room Thermostat in a room you use frequently in your living space. For example; like the hall or living room of your home. Avoid installing the Room Thermostat in places where there is a lot of air circulation, such as at the doorway or by the window. Also, do not place it close to heating units (heater core, fireplace, etc.) and in direct sunlight. We recommend that the room thermostat is placed at a height of 150 cm from the floor.
min. 20 cm
ROOM THERMOSTAT TEMPERATURE CALIBRATION Temperature sensors used in Room Thermostats are very sensitive. Based on the temperature on the thermometers in your living space you need to calibrate your Room Thermostat. For this: While your device is off, press and hold the button for 3 seconds. Press the button until you see the calibration menu that says ” ”
press it. The temperature difference you want from the calibration menu, Adjust by turning the button to the right or left. This value can be adjusted between “-8°C” and “+8°C”. Press the button until the device turns off to save the settings and exit. Note: Recommended temperature calibration setting is “0.0oC”.
ROOM THERMOSTAT HEATING / COOLING MODES Your Room Thermostat has heating and cooling modes. In order to switch easily between heating and cooling modes: While your device is turned off, press and hold the button for 3
seconds. Press the button until the ” ” menu appears. You can switch between ” ” (heating) and ” ” (cooling) modes
by turning the button to right or left in the ” ” menu. To save the settings and exit, press the button until the device turns
off. The settings you have made have been saved. Once you turned on
your device, it will operate with the changed settings.
ROOM THERMOSTAT HYSTERESIS POSITIVE MENU The hysteresis positive factory setting of your Room Thermostat is 0.5°C. This value can be adjusted between “0.1°C” and “2.0°C”. While the hysteresis positive value is 0.5°C, your Room Thermostat will send a command to your heating unit when the room temperature rises 0.5°C above the set temperature. For example, when we set the Room Thermostat to 22.0°C, your heating unit will stop when the room temperature rises to 22.5°C. To change the hysteresis positive setting: While your device is off, press and hold the button for 3 seconds. “Press the button until the ” ” menu appears. In the hysteresis positive menu, you can adjust the operating
sensitivity by turning the ” ” button to the right or left. Press the button until the device turns off to save the settings and
exit. The settings you have made have been saved. When you turn on
your device, it will work with the operating sensitivity you have set.

150 cm

ROOM THERMOSTAT HYSTERESIS NEGATIVE MENU The hysteresis negative factory setting of your Room Thermostat is -0.5°C. This value can be adjusted between “-0.1°C” and “-2.0°C”. While the hysteresis negative value is -0.5°C, your Room Thermostat will send a command to your heating unit when the room temperature drops 0.5°C below the set temperature. For example, when we set the Room Thermostat to 22.0°C, your heating unit will work when the room temperature drops to 21.5°C. To change the hysteresis negative setting :While your device is off, press and hold the button for 3 seconds. Press the button until the ” ” menu appears. In the hysteresis negative menu, you can adjust the operating
sensitivity by turning the ” ” button to the right or left. Press the button until the device turns off to save the settings and
exit. The settings you have made have been saved. When you turn on
your device, it will work with the operating sensitivity you have set.
FLOOR SENSOR TEMPERATURE SETTING MENU If a floor sensor is installed with Room Thermostat, only GENERAL Life floor sensor should be installed. Otherwise, the product will be out of warranty. In case of floor sensor connected, the following settings apply. The factory temperature setting for floor sensor is 28°C. This value can be adjusted between 23°C and 34°C. The floor sensor operating sensitivity is 1°C. For example, when you set the floor sensor temperature to 28°C, your Room Thermostat will stop the heating unit from working when the floor temperature rises to 29°C. When the floor temperature drops to 27°C, it starts the heating unit of the Room Thermostat. To change the floor sensor temperature: Press and hold the button for 3 seconds while your device is off. Press the button until the ” ” menu appears. Adjust the operating temperature by turning the ” ” button to the
right or left in the floor sensor temperature menu that appears. Press the button until the device turns off to save the settings and
exit. The settings you have made have been saved. When you turn on
your device, it will operate at the floor sensor temperature you have set.
FACTORY RESET You can reset the Room Thermostat to its factory default settings. This action resets the calibration setting and hysteresis settings to the factory setting. To factory reset your Room Thermostat: While your device is off, press and hold the button for 3 seconds. Press the button until the ” ” menu appears. While in the ” ” menu, turn the button to the right or left, select the
” ” option and press the button. Your device will turn off and reset to factory settings.
ROOM THERMOSTAT WORKING PRINCIPLE Heating Mode As soon as you energize your Room Thermostat, it will start working. Your room thermostat takes the average room temperature of last 40 seconds as basis. If the ambient temperature rises above the hysteresis positive temperature you set, your Room Thermostat turns off the heating unit, and if it drops below hysteresis negative temperature value, it turns on the heating unit. Thus, it is ensured that the ambient temperature remains within a certain range. If the floor sensor measures temperature above 28°C, it turns off the heating unit.
*External floor sensor is only active when it is connected.

Room Temperature
Set Temperature
Heating Unit On
Heating Unit Off

22.5oC 22.0oC 21.5oC Time

Cooling Mode As soon as you energize your Room Thermostat, it will start working. Your room thermostat takes the average room temperature of last 40 seconds as basis. If the ambient temperature rises above the hysteresis positive temperature you set, your Room Thermostat will start the cooling unit and if it drops below hysteresis negative temperature value, will stop the cooling unit. Thus, it is ensured that the ambient temperature remains within a certain range.

*External floor sensor is deactivated in the cooling mode.

Room Temperature
Set Temperature

22.5oC 22.0oC 21.5oC

Cooling Unit On

Cooling Unit Off

Time

1

2

3

4

ROOM THERMOSTAT WIRING DIAGRAM

1

4

2

5

N

L

NTC

L1

N1

3

6 WARNING!

The assembly of product should be done according to the image above.

For electrical connection, please see diagram 5.

Should not be used in case the usage of a wiring center.

WIRING DIAGRAM FOR ACTUATORS

N

L

L1

N1

230V AC

ACTUATOR

5

WIRING DIAGRAM FOR WIRING CENTER

N

L

L1

N1

230V AC

WIRING CENTER

WARNING! Operating related to the control panel, heating / cooling unit or electrical installation must be carried out by persons with professional qualifications.

DECLARATION OF CONFORMITY

ISIPARK Ç VE DI TC. N. ISITMA SSTEMLER OTO. SAN.A..which

Head Office and production site is located on Fatih Mah. 1188

Sk.No:13/A Sarniç – Gaziemir – ZMR ­ TÜRKYE confirms and

declares that the product marked with CE and its specifications below

is covered by the provisions of the mentioned directive.

Brand

: GENERAL Life

Product Name : FH25/FH25S

Product Type : Underfloor Heating Thermostat

Compatible Directives:

Electromagnetic Compatibility Regulation 2014/30/EU

(EN 61000-6-1:2019, EN 61000-6-3:2021)

Low Voltage Directive 2014/35/EU (IEC 60730-2-9)

Additional Information: The mentioned product can be used with

boilers with on / off output and compliance with the directives only

covers the product. ISIPARK is not responsible for the entire system’s

compliance with the directives. This statement is not valid if changes

are made to the product without our approval.

6

WARRANTY CONDITIONS 1-The warranty period starts from the invoice date and warranted against manufacturing defects for 2 years. 2-Devices and apparatus are delivered to the customer in working condition in our company. On-site commissioning is subject to a service fee. 3-The repair of the devices and apparatus covered by the warranty is carried out in our company factory and should send by a contracted transportation company. In on-site services, the transportation and accommodation expenses of the service personnel belong to the customer. The shift fee during transportation is added to the service fee and collected in advance. 4-The maintenance of devices and apparatus is done in our company. For the maintenance of the devices and apparatus, the round travel fares belong to the customer. 5-In case of malfunctioning of the devices and apparatus whose warranty period continues, it is tested in our company whether the malfunction is caused by a customer or manufacturer fault, and it is reported with a report issued by our company. 6-In case of detection of manufacturer-induced errors of devices and apparatus whose warranty period continues, the customer can request a replacement or repair of the devices and apparatus at full expense by the manufacturer, unless it’s higher than the product’s price. 7-In the event that the faults of the devices and apparatus whose warranty period continues are determined as caused by the customer, all expenses would belong to the customer. 8-Customers should be aware of damages (if there are any) of product and warn manufacturer since the day warranty duration starts.If customer do not warn manufacturer with knowledge of damage, customer loses the rights of article 6. 9-Malfunctions resulting from the use of devices and apparatus contrary to the matters stated in the User Manual are not covered by the warranty. 10-Devices and their apparatus are out of warranty if they are beaten, broken or scratched by the customer. 11-Damages resulting from the use of devices and apparatus belonging to other brands and models without the approval of the manufacturer are not covered by the warranty. 12-Battery leakage and errors due to rust, oxidation, and liquid contact by working in acidic/humid environments are not covered by the warranty. 13-When the product is not used for a long period (more than 15 days), remove the batteries. Otherwise, malfunctions that will occur are out of warranty. 14-Damages that may occur during the transportation of devices and apparatus are not covered by the warranty. Customers can take transportation insurance. 15-Damages caused by mains voltage / faulty electrical installation are not covered by the warranty. 16-Devices and apparatuses are out of warranty for malfunctions caused by force majeure such as fire, flood, earthquake, etc. 17-All of the devices and apparatuses, including all their parts, are under the warranty of our company. 18-In case of malfunction of the devices and apparatuses within the warranty period, the time spent during repairment period is added to the warranty period. The repair period of the product cannot exceed 20 working days. This period starts from the date of notification to the service station of the malfunction related to the product or, in the absence of a service station, to the seller, dealer, agency, representative, importer or manufacturer of the product. Consumer can report the problem by; phone, fax, e-mail, registered and reply paid letter or a similar way. However,in case of a conflict , responsibility of prove is belong to the customer. If the malfunction of the product is not repaired within 20 working days, the manufacturer-producer or importer; has to allocate another product with similar features to the use of the consumer until the repair of the product is completed. 19-Although the consumer uses his/her repair rights, -If the product breaks down for 4 times in a year or 6 times in warranty duration and these problems effects main purpose of the product. (starting from delivery time during warranty.) – Exceeding the maximum time required for repair, – In the event that the service station is not available, if it is determined that the repair of the defect is not possible with the report prepared (in order) by one of the seller, dealer, agency, representative, importer or manufacturer, a refund or a price discount at the rate of defect can be requested. 20-The customer can make complaints and appeals to consumer courts or consumer arbitration committees. 21-The warranty document must be kept by the customer during the warranty period. If the document is lost, a second document will not be issued. In case of loss, repair and replacement of devices and apparatus will be made for a fee.
7

WARRANTY CERTIFICATE
Manufacturer Title: ISIPARK Ç DI TC. A.. Address: Fatih Mah. 1188 Sk. No:13/A Sarniç Gaziemir zmir-TÜRKYE Tel: +90 (232) 457 99 50 Fax: +90 (232) 457 91 22 E-mail: generallife@generallife.com.tr Authorized Signature: Company Stamp:
Product Type: Underfloor Heating Thermostat Brand: GENERAL Life Model: FH25/FH25S Warranty Period: 2 Years Max. Time to Repair: 20 Days Bandrol and Serial Number:

Vendor Title:

Address:

Tel:

Fax:

E-Mail:

Invoice Date and Number:

Delivery Time and Place:

Authorized Signature:

Company Stamp:

Product Type: Underfloor Heating Thermostat Brand: GENERAL Life Model: FH25/FH25S

STAMP

ISIPARK reserves the rights of changing product specifications and user manuals. * For all changes, you may visit generallife.com.tr
8

V-01.2023

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals