MARVEL MRNP215-IS01A Undercounter Refrigeration Owner’s Manual
- September 24, 2024
- Marvel
Table of Contents
- MRNP215-IS01A Undercounter Refrigeration
- Product Information
- Specifications
- Product Usage Instructions
- Warranty Registration
- Installation and Maintenance
- Safety Instructions
- Unpacking Your Appliance
- Product Showcase
- Where can I find the serial number of the appliance?
- What do I do if there is damage during transit?
MRNP215-IS01A Undercounter Refrigeration
Product Information
Specifications
- Model: MRNP215-IS01A
- Brand: Marvel
- Type: Undercounter Refrigeration
- Refrigerant: R600a (isobutane)
Product Usage Instructions
Warranty Registration
To register your product warranty, visit
www.marvelrefrigeration.com and
provide the following information:
- Serial Number
- Date of Purchase
- Dealer’s name and address
Installation and Maintenance
Refer to the owner’s guide for detailed instructions on
installing and maintaining your Marvel undercounter refrigerator.
Contact the Technical Support team at
616-754-5601 for
assistance.
Safety Instructions
Exercise caution when installing, maintaining, or operating the
appliance. Follow all safety instructions provided in the manual to
ensure safe usage.
Unpacking Your Appliance
When unpacking your appliance, ensure to use two or more people
due to excessive weight. Remove all internal packaging materials
and inspect the appliance for any damage before disposal of
packaging.
Product Showcase
Share photos of your Marvel product in its new home by emailing
them to marketing@marvelrefrigeration.com for a chance to be
featured on the website and social media.
FAQ
Where can I find the serial number of the appliance?
The serial number is located on the back of the cabinet near the
top.
What do I do if there is damage during transit?
If your appliance is damaged during transit, keep the packaging
for inspection and contact customer support for assistance.
OWNER’S GUIDE & SERVICE MANUAL
MARVEL UNDERCOUNTER REFRIGERATION
Model: MRNP215-IS01A
WELCOME
Welcome to the Marvel Experience!
Warranty Registration
Thank you for choosing our quality product to add to your home. We are
thrilled to welcome you to our growing community of Marvel owners, who trust
in our products and our support.
The information in this guide is intended to help you install and maintain
your new Marvel undercounter model to protect and prolong its lifetime. We
encourage you to contact our Technical Support team at
616-754-5601 with any questions.
It is important you register your product warranty after taking delivery of your appliance. You can register online at www.marvelrefrigeration.com.
The following information will be required when registering your appliance: Serial Number Date of Purchase Dealer’s name and address
Online registration available at
marvelrefrigeration.com
Got a Marvelous Design?
We would love to see how your Marvel product looks in its new home. You can
send us photos of your installed product at marketing@marvelrefrigeration.com,
and we might feature your Marvel home design on our website and social media!
The serial number is located on the back of the cabinet near the top.
IMPORTANT SAFETY INSTRUCTIONS
Important Safety Instructions
Warnings and safety instructions appearing in this guide are not meant to
cover all possible conditions and situations that may occur. Common sense,
caution and care must be exercised when installing, maintaining or operating
this appliance.
Recognize Safety Symbols, Words and Labels
! WARNING
WARNING – You can be killed or seriously injured
if you do not follow these instructions.
! CAUTION
CAUTION – Hazards or unsafe practices which could result in personal injury or
property/product damage.
NOTE
NOTE – Important information to help assure a
problem-free installation and operation.
! WARNING
State of California Proposition 65 Warning: This product contains one or more
chemicals known to the State of California to cause birth defects or other
reproductive harm.
! WARNING
State of California Proposition 65 Warning: This product contains one or more
chemicals known to the State of California to cause cancer.
! WARNING
WARNING – This unit contains R600a (isobutane)
which is a flammable hydrocarbon. It is safe for regular use. Do not use sharp
objects to expedite defrosting. Do not damage refrigerant circuit.
3
UNPACKING YOUR APPLIANCE
! WARNING
! CAUTION
EXCESSIVE WEIGHT HAZARD
Use two or more people to move product. Failure to do so can result in
personal injury.
Remove Interior Packaging
Your appliance has been packed for shipment with all parts that could be
damaged by movement securely fastened. Remove internal packing materials and
any tape holding internal components in place. The getting started guide is
shipped inside the product in a plastic bag along with the warranty
registration card and other accessory items.
Important
Keep your carton and packaging until your appliance has been thoroughly
inspected and found to be in good condition. If there is any damage, the
packaging will be needed as proof of damage in transit. Afterwards, please
dispose of all items responsibly.
! WARNING
If the appliance was shipped, handled or stored in other than an upright
position for any period of time, allow the appliance to sit upright for a
period of at least 24 hours before plugging in. This will assure oil returns
to the compressor. Plugging the appliance in immediately may cause damage to
internal parts.
! WARNING
WARNING – Help Prevent Tragedies
Child entrapment and suffocation are not problems of the past. Junked or
abandoned refrigerators are still dangerous, even if they sit outside for
“just a few hours”.
If you are getting rid of your old refrigerator, please follow the
instructions below to help prevent accidents.
Before you throw away your old refrigerator or freezer: · Take off the doors
or remove the drawers. · Leave the shelves in place so children may not
easily climb inside.
WARNING – Dispose of the plastic bags which can
be a suffocation hazard.
Note to Customer
This merchandise was carefully packed and thoroughly inspected before leaving
out facility. Responsibility for its safe delivery was assumed by the retailer
upon acceptance of the shipment. Claims for loss or damage sustained in
transit must be made to the retailer.
NOTE
DO NOT RETURN DAMAGED MERCHANDISE TO THE MANUFACTURER – FILE THE CLAIM WITH
THE RETAILER.
4
ELECTRICAL
Do not remove ground prong
Electrical Connection
A grounded 115 volt, 15 amp dedicated circuit is required.
This product is factory equipped with a power supply cord that has a three-
pronged, grounded plug. It must be plugged into a mating grounding type
receptacle in accordance with the National Electrical Code and applicable
local codes and ordinances. If the circuit does not have a grounding type
receptacle, it is the responsibility and obligation of the customer to provide
the proper power supply. The third-ground prong should not, under any
circumstances, be cut or removed.
! WARNING
Shock Hazard Electrical Grounding Required
Never attempt to repair or perform maintenance on the unit until the
electricity has been disconnected.
Never remove the round grounding prong from the plug and never use a two-prong
grounding adapter.
Altering, cutting or removing power cord, removing the power plug, or direct
wiring can cause serious injury, fire, loss of property and/or life, and will
void the warranty.
Never use an extension cord to connect power to the unit.
Always keep your working area dry.
NOTE
Ground Fault Circuit Interrupters (GFCI) are prone to nuisance tripping which
will cause the appliance to shut down. GFCI’s are generally not used on
circuits with power equipment that must run unattended for long periods of
time, unless required to meet local building codes and ordinances.
5
CUTOUT AND PRODUCT DIMENSIONS
Prepare Site
Your Marvel product has been designed for either freestanding or built-in
installation. When built-in, your unit does not require additional air space
for top, sides, or rear. However, the front grille must NOT be obstructed, and
clearance is required for an electrical connection in the rear.
! CAUTION
Unit can NOT be installed behind a closed cabinet door. If you would like to
align the face of the unit with other adjacent cabinet doors, you may need to
alter the wall just behind the drain connection on the unit to accomodate the
drain.
Cutout Dimensions
Front
33 / ” (860 mm
Preferred location
for electrical and
water is in adjacent
cabinet.
5/8″
(16 mm)
24″ (610 mm)
7″ (178 mm)
4″ (102 mm)
15″ (381 mm)
Product Dimensions
Rear
Top Side
105
6
INSTALLING YOUR APPLIANCE
General Installation
Leveling Information
1. Use a level to confirm the unit is level. Level should be placed along top
edge and side edge as shown.
1
Installation
1. Plug in the power/electrical cord. 2. Gently push the unit into position.
Be careful not to
entangle the cord or water and drain lines, if applicable. 3. Re-check the
leveling, from front to back and side to
side. Make any necessary adjustments. The unit’s top surface should be
approximately 1/8″ (3 mm) below the countertop. 4. Install the anti-tip
bracket. 5. Remove interior packing material and wipe out the inside of the
unit with a clean, water-dampened cloth.
2. If the unit is not level, adjust the legs on the corners of the unit as necessary.
Turn to Adjust
3. Confirm the unit is level after each adjustment and repeat the previous
steps as needed.
Installation Tip
If the room floor is higher than the floor in the cutout opening, adjust the
rear legs to achieve a total unit rear height of 1/8″ (3 mm) less than
opening’s rear height. Shorten the unit height in the front by adjusting the
front legs. This allows the unit to be gently tipped into the opening.
Readjust the front legs to level the unit after it is correctly positioned in
the opening.
7
DOOR REVERSAL
Reverse Door Swing
The hinges are attached to the right-hand side of the door when the product is
shipped from the factory. However, the ice maker is designed so that the
hinges may be installed on either side. If the hinges are moved to the left-
hand side, the door will open to the left.
Prepare Door
1. Rotate door 180°. 2. Remove gasket and gasket channel cover. 3. Install
gasket and gasket channel cover on opposite
end of door.
Remove Door
1. On both hinges, loosen but do not remove the outside screws.
2. Remove the inside screws. 3. Carefully shift the door to the right to free
the hinges
from the loosened screws. Set door aside with hinges still attached. 4.
Tighten the screws.
Install Door
1. On the opposite side of the cabinet, loosen but do not remove the outside
screws.
2. Remove the inside screws. 3. Line up the holes on the hinges with the
loosened
screws and slide door all the way to the left. 4. While still holding the
door, install the remaining
screws. 5. Tighten all 4 screws. 6. Check door for proper swing.
8
INTEGRATED PANEL DIMENSIONS
Integrated Panel
Integrated Panel Dimensions
NOTE
Due to differences in surrounding cabinetry, the panel may not perfectly align
with door. The procedure below is designed to prepare a finished integrated
panel that seamlessly integrates with surrounding cabinetry.
The door panel must not weigh more than 20 lbs (10 kg).
It is important to ensure that all drilled holes are drilled to the correct
depth in order to avoid splits in the wood when hardware is installed.
When applying an integrated panel to a unit, ensure that both sides are
finished in order to prevent warping.
A full integrated door panel completely covers the door frame and provides a
built-in appearance.
Integrated Panel Preparation
1. Cut the panels to the dimensions listed in the diagram below. For optimal
results, have a qualified carpenter verify all measurements.
2. Optional: Stain or finish panel to desired stain or color. Be sure to
closely follow the instructions provided by the manufacturer.
3. Optional: Install handles and hardware.
BACK SURFACE MUST HAVE AMPLE FLAT SURFACE
TO MOUNT OVERLAY PANEL FLAT AND WITHOUT 3/4″
INTERFERENCE
(19 mm)
14 / ” (376 mm)
30 / ” (764 mm)
9
INTEGRATED PANEL INSTALLATION
Prepare Integrated Panel
1. Remove door from unit (see Door Reversal) 2. On a flat surface, line up
the door to the integrated door
panel and clamp. 3. Remove gasket channel filler to expose side holes. 4.
Intall 10 screws to secure door panel.
5. Reinstall gasket channel filler. 6. Remove clamps. 7. Reinstall door to
unit (see Door Reversal)
10
Display Panel
OFF
USING YOUR ELECTRONIC CONTROLS
Light Button
Ice No Water Drain Lamp Lamp Lamp
!
Control Function Guide
FUNCTION
Light Button Ice Lamp No Water Lamp Drain Lamp
COMMAND
Press and release Lights up when operation switch is set to “ICE” Lights up to
indicate low water supply Lights up to indicate activation of the drain valve.
NOTES
Light turns on or off
11
INSTALLING THE WATER SUPPLY
Water Hookup
Prepare Plumbing
Plan the arrangement of the water supply pipes. Connect a 1/4″ diameter copper
waterline to the tap water supply line. Install a shutoff valve between the
tap water pipe and the product so that the user can operate the valve. Do not
install the shutoff valve at the back of the product. Do not use a self-
piercing valve. Water quality directly affects performance and product life
use of an inline water filter is strongly recommended & do not use softened
water.The pressure of the tap water should be maintained at a level between
20psi (1.4bar) and 80psi (5.5bar).
Do not use tape or joint compound when attaching a braided flexible water
supply line that includes a rubber gasket. The gasket provides an adequate
seal other materials could cause blockage of the valve.
Failure to follow recommendations and instructions may result in damage and/or
harm, flooding or void the product warranty.
Use new hose set. Do not reuse old hose set.
! CAUTION
! CAUTION
Turn off water supply and disconnect electrical supply to unit prior to installation.
Plumbing installation must observe all state and local codes. All water and
drain connections MUST BE made by a licensed/qualified plumbing contractor.
Failure to follow recommendations and instructions may result in damage and/or
harm.
Water Supply Connection
When connecting the water supply, please note the
following:
· Before installing the unit and connecting to the cold water supply, review
the local plumbing codes.
· Softened water is not recommended as it may result in softer ice than
desired. If using softened water, install a bypass to supply untreated water
to the ice maker.
· Water produced by reverse osmosis and deionized water are NOT recommended.
It us more corrosive than tap water and can cause harm to the equipment over
time.
· Connection to the water main is made with hose-set
only. · Hose-set must be new, not reused, and in compliance
with IEC 61770.
· The water line MUST have a shut-off valve in the supply line.
· The water line should be looped into 2 coils. This will allow the unit to be
removed for cleaning and servicing. Make certain that the tubing is not
pinched or damaged during installation.
Use caution when handling back panel. The edges could be sharp.
Install Water Supply
1. Install the inlet pipe (1/4″ diameter copper pipe) on the wall and connect
the water supply valve.
2. Use the inlet pipe after cutting it to the required length. 3. Wash the
inlet pipe. 4. Connect the inlet pipe with the copper pipe using the
flare nut. 5. Connect the inlet pipe with the water supply valve of
the product using the flare out. 6. Turn on the tap and check for any leakage.
Drain Tube
Water Inlet Tube Shut-Off Valve
Water Filter
!
Do not use any plastic water supply line. The line is under pressure at all
times. Plastic may crack or rupture with age and cause damage to your home.
12
INSTALLING THE DRAIN PLUMBING
Drain
SECURE DRAIN HOSE TO BACK PANEL
! CAUTION
Do not pull or bend the drain hose to avoid damage to the drain pump. Drain
hose must be secured to the rear of the machine before connecting to drain.
1. Find hose clamp and screw in the literature package that came with your
machine.
2. Secure hose using supplied clamp and screw.
There is a possibility that hose connections may have loosened during
shipment. Verify all connections and fittings are free from leaks.
! CAUTION
This equipment is to be installed with adequate backflow protection to comply
with applicable federal, state and local codes.
Hookup Drain Pump See below for typical installations.
DRAIN HOSE
CLAMP
Drain Connection
! CAUTION
Failure to connect water supply or drain line connections properly can result
in personal injury and property damage. Do not pull the drain hose to avoid
damage to drain pump.
! CAUTION
The floor drain must be large enough to accommodate drainage from all attached
drains. Follow these guidelines when installing drain lines to prevent water
from flowing back into the ice maker storage bin and/or potentially flowing on
to the floor, which may result in personal injury or property damage.
NOTE
Drain can NOT be located directly below the unit. Unit has a solid base that will not allow the unit to drain below itself.
NOTE
The maximum lift for the drain pump is 10 feet. This must be done as close to
the rear of the unit as possible.
13
ICE MAKER OPERATION
Ice
! CAUTION
Do not put anything other than ice in the ice bin. Wine or beer bottles are
unsanitary and a detached label may block the drain.
! CAUTION
If the ice storage bin is full of water, turn off the ice maker and clean the
mesh on the bottom of the ice bin.
Approximate size and shape of a cube (image not to scale).
Ice-Making Process
Water flows into the drum, and as the auger rotates, the water freezes and is
ejected upward. Impurities in the water are periodically discharged by the
drain valve to create clean ice
Operation Time
The machine continues to operate until the ice bin is full, which takes about
10 hours (this time will vary slightly based upon ambient and water
temperatures).
The machine ceases ice production when the ice level reaches the temperature
sensing tube located on the right side.
! CAUTION
When the door is open, the ice maker cannot detect if the bin is full. Be sure
to keep door closed during ice production.
14
CARE AND CLEANING
Cleaning
NOTE
Use only Marvel Ice Machine Cleaner (S41013789), available for purchase from
marvelrefrigeration.com or your dealer. It is a violation of federal law to
use this solution in a manner inconsistent with its labeling. Use of any other
cleaner can cause damage to the ice machine and will void the warranty. Read
and understand all labels printed on the package before use.
Marvel Ice Machine Cleaner is used to remove lime scale and other mineral
deposits. Refer to the following steps to initiate the self-cleaning cycle.
External Cleaning
If the surface of the door and lever become stained, clean immediately. If the
door and/or gasket have spots on the surface, remove the spots using soap and
warm water with a non-abrasive cloth or sponge. For stainless steel exterior,
use a soft and non-abrasive stainless steel cleaner (such as the liquid
variety of Barkeeper’s Friend) and a soft lintfree cloth.
Clean the Ice Bin
The ice bin should also be cleaned regularly. Combine 1 ounce of bleach with 2
gallons of warm water at 95°F 115°F (35°C – 45°C) to use as a cleaning
solution. Dampen a clean cloth with the cleaning solution and wash the inside
of the ice bin. Pour a small quantity of the solution into the drain pipe,
then dry the interior.
Internal Cleaning
1. Dilute 2 oz. of Ice Machine Cleaner into two quarts of water.
2. Open the door and pour approximately 1 quart (1 liter) of cleaning
solution into the ice spout.
3. Toggle the lower front mode switch to .
4. The ice maker automatically cleans, drains, and supplies water repeatedly,
which takes about 10 minutes.
5. Use a sponge or cloth to clean the inside of the reservoir with the
remaining cleaning solution.
6. After 10 minutes, rinse the inside of the reservoir with clean water,
pouring some water into the ice spout.
7. Toggle the mode to switch to again. 8. After about 10 minutes, the
cleaning processes will be
completed.
15
CARE AND CLEANING
Cleaning the Condenser
! WARNING
Disconnect electric power to the unit before cleaning the condenser. DO NOT
use any type of cleaner on the condenser unit. Condenser may be cleaned using
a vacuum, soft brush, or compressed air. The condenser should be cleaned 2-3
times a year to remove any lint that has penetrated the condenser. When
cleaning the condenser, remove the front lower panel. Then, remove any dust
and lint from the condenser using a soft bristle brush. For the position of
the condenser, refer to the drawing.
16
OBTAINING SERVICE
If Service is Required:
· If the product is within the first year warranty period, please go to
marvelrefrigeration.com/request-productservice or call Marvel Customer Service
at 616.754.5601 for directions on how to obtain warranty coverage in your
area.
· If the product is outside the first year warranty period, Marvel Customer
Service can provide recommendations of service centers in your area. A listing
of authorized service centers is also available at www.marvelrefrigeration.com
under the service and support section.
· In all correspondence regarding service, be sure to give the service number,
serial number, and proof of purchase.
· Try to have information or description of nature of the problem, how long
the appliance has been running, the room temperature, and any additional
information that may be helpful in quickly solving the problem.
· Table “B” is provided for recording pertinent information regarding your
product for future reference.
For Your Records Date of Purchase Dealer’s name Dealer’s Address Dealer’s City
Dealer’s State Dealer’s Zip Code Appliance Serial Number Appliance Service
Number Date Warranty Card Sent (Must be within 10 days of purchase).
Table B
17
TROUBLESHOOTING
CURRENT CONDITION
Ice Making
Washing
Ice Full (Storage bin)
LAMP
···
ICE
NO DRAIN
WATER
CAUSES
ACTION
L
When the operation switch is switched to the position
When the operation switch is
When you turn the operation switch to the
B
changed to , the `ICE’ lamp blinks (every ‘off’ position, the water will drain and stop
1 second)
after performing the cleaning procedure.
When the storage bin is full of ice (Ice
B
Lamp on every 2 seconds, turns off for 1
second repeatedly).
Drain valve operating
Water supply error
B
Water drain error
Evaporator temperature
B
B
Evaporator
B
temperature error
Ice full sensor error
Evaporator temperature sensor error
B
B
B
Air temperature
B
sensor
Evaporator freezing
L
L
L = Lamp On; B =Lamp Blinking
L
When the drain valve opens
When water level is not detected by the water level sensor due to no water supply for 2 minutes. (Er15). Automatically resets after 5 minutes.
Check water supply pressure. Check water level sensor. Start operation after action.
If the lower limit water level sensor is not
Replacement of water level sensor.
B
detected within 2 minutes as the drain valve Check drain valve operation. operates. (Er16). Automatically resets after Check for clogged drain.
5 minutes.
Start operation after action.
When the Evaporator temperature is 32°F
B
or more after 30 minutes passed during
Check refrigerant leakage.
the ice making (Er01)
Check sensor and attachment abnormality.
When the Evaporator temperature is 32°F or more after 10 minutes passed during
Resupply power after resolving cooling problem.
the ice making (Er03)
B
When the ice full temperature sensor in the storage bin is disconnected or shorted
When the EVA temperature sensor at the Check sensor and attachment abnormality. evaporator outlet is disconnected or shorted Start operation after sensor part repair.
When the air temperature sensor in front
B
of the condenser is disconnected or
shorted
L
When the evaporator outlet temperature drops below -7.6°F while the ice maker is
Operate after the temperature is over 50°F and 1 hour has passed.
running. (Er25)
18
TROUBLESHOOTING
-The following maintenance schedule is guideline -Maintenance and repair should be done more frequently according to water quality,
equipment usage environment and local hygiene regulations.
Maintenance Schedule
Frequency Area
Daily
Scoop
Monthly External water filter Outside of the ice maker
Every 6 Months
Storage Bin, Inner door, Ice outlet(Spout) Icemaker andStorage Bin
Evaporator Condensate Drain Pan and Gear Motor Drain Pan
Task Clean the scoop using a neutral cleaner. Rinse thoroughly after cleaning.
Make sure that the pressure is adequate and make changes if needed. Wipe down
with clean, soft cloth. Use a damp cloth containing a neutral cleaner to wipe
off oil or dirt build up. Clean any chlorine staining (rustcolored spots)
using a non-abrasive cleanser. Wipe clean with clean cloth and warm water.
Clean and disinfect according to the disinfection instructions given in the
instruction manual. Wipe down with clean cloth and warm water.
Yearly
After 3 Years, then Yearly
Ice maker and reservoir Always check that it is kept clean.
Ice exit fixing seal bolt
Check for leaks around the seal bolt. Tighten if necessary and replace O-rings. Always replace the O-ring when loosening the seal bolt and tighten it again.
Condenser (air-cooled)
If there isno O-ring, apply Loctite 243 or equivalent fixing agent so that it
does not leak.
Inspect for cleaning. If necessary, clean with a brush or vacuum cleaner If
the dust adhesion is severe, spray the pin cleaning agent, clean the dust,
spray it with clean water, rinse gan, dpdprlyy with air gun. Celeqan
condensegr evgeery 6 months.
Water supply valve and Drain valve
Water hose
Close the shutoff valve to shut off the water supply line and drain the water. Check the water hose and clean it if necCCellseesaaannrycc. oonnddeennsseerr eevveerryy 66 mmoonntthhss..
Ice maker
Inspect for oil marks, loose components, tightening parts and wires.
Upper bearing (Ice exit head)
Check that 0.02″ round bar or pin gauge (or clearance gauge) is inserted into auger and bearing clearance, and replace all uCplpeearnacnodnldoewnesrebreeavrienrgys 6(icmeoenxtithsh.ead
and lower housing)
Mechanical seal
Check for leaks in the bottom housing, and if there is a leak, disassemble the auger
to replace the mechanical seal. (Water with a lot of calcium will shorten
the life of replacement parts.)
Upper and lower bearings, Please chek. If the auger and bearing clearance exceeds the factory recommended
Housing O-ring,
value (0.02″ or less), replace both the upper and lower bearings.
Mechanical seals,
If the contact surface of the mechanical seal is worn, cracked, or scratched, replace it.
Evaporator cylinder, Auger
19
LED UV
WIRE DIAGRAM
20
Product Liability
Field service technicians are authorized to make an initial assessment in the
event of reported damages. If there are any questions about the process
involved, the technician should call Marvel for further explanation. While
inspecting for defects or installation issues, photos should be taken to
document any damages or issues found. During the assessment, if the service
technician is able to find the source of the damage and it can be resolved by
replacement of a part, the servicer is authorized to replace the part in
question. The part that caused the damage must be returned to Marvel in its
entirety. The part must be clearly labeled with the serial number of the unit
it was removed from, the date, and the servicer who removed the part. If the
service technician determines the damage is the result of installation issues
(water connection/drain, etc.), the consumer would be notified and the issues
shall be resolved at the direction of the consumer. If damage is evident and
the service technician is unable to find the source, Marvel must be contacted
at 616.754.5601 for further direction.
1260 E. Van Deinse St· Greenville, MI 48838 T: +1.616.754.5601
Website: www.marvelrefrigeration.com The original refrigeration experts since
1892.
Product Liability
21
PARTS LIST
8
MRNP215-IS01A
3
21 11 18
17
6 10
1
19 8
2 20
25
5 4
22
PARTS LIST
1 AIR SENSOR (BLUE)
80-55453-06
2 AUGER ASSEMBLY
80-55381-02
3 BACK PANEL (REAR COVER)
80-55342-09
4 BASE BRACKET(G-BOX)
80-55342-01
5 CAPACITOR KIT
80-55453-05
6 COMPLETE CONTROL KIT
80-55398-07
7 COMPRESSOR ASSEMBLY
80-55453-04
8 CONDENSER ASSEMBLY
80-55453-02
9 CONDENSER FAN ASSEMBLY
80-55453-03
10 DISPLAY ASSEMBLY
80-55398-06
11 DOOR ASSY, PANEL-READY W/ 80-55354-01
12 DRAIN ASSEMBLY
80-55227-04
13 DRAIN KIT FOR PUMP
80-55227-07
14 DRAIN PUMP ASSEMBLY
80-55227-03
15 DRAIN PUMP ASSY(BLDC)
80-55227-01
16 EVAPORATOR ASSEMBLY
80-55381-01
- Not Pictured
17 FRONT LOW-COVER KIT
80-55342-08
18 GASKET, DOOR (INTEGRATED) 80-55453-08
19 GRILLE ASSEMBLY (OUTDOOR) 80-55453-13
20 ICE MAKING UNIT (NUGGET)
80-55381-03
21 ICE SCOOP ASSEMBLY
80-55352-00
22 INLET SOCKET ASSEMBLY
80-55227-08
23 LEVELING LEGS
80-55342-02
24 MAGNET ASSEMBLY
80-55342-04
25 MAIN BOARD KIT
80-55398-09
26
MOTOR+GEAR BOX ASSY(1:200, 40W)
80-55381-04
27 POWER CORD ASSEMBLY*
80-55398-10
28 SMPS BOX KIT
80-55398-08
29 U-PIPE ASSEMBLY
80-55381-05
30 WATER INLET VALVE ASSEMBLY 80-55227-05
31 WATER RESERVOIR ASSEMBLY 80-55381-06
32 WATER VALVE ASSEMBLY
80-55227-06
6 24
28 25
23
Ordering Replacement Parts
Parts may be o rdered online at partsformarvel.com
Or contact:
www.marvelrefrigeration.com (Servicers choose “Login” for service account).
Phone Numb er: 616-754-5601
NOTICE Use only genuine Marvel replacement parts. The use of non-Marvel parts
can reduce performance, damage the unit, and void the warranty.
Warranty parts will be shipped at no charge after Marvel confirms warranty
status. Please provide the model, serial number, part number and part
description. Some parts will require color or voltage information.
Marvel requires the return of original parts, we will inform you when the
parts order is taken. This requirement will be noted on your packing list. A
prepaid shipping label will be emailed to you. Please enclose a copy of the
parts packing list and be sure the model and serial numbers are legible on the
paperwork. Tag the part with the reported defect.
Customers and non-authorized servicers may order non warranty parts at
www.partsformarvel.com. Authorized servicers with a servicer login may order
non-warranty
parts at www.marvelrefrigeration.com.
Ordering Replacement Parts
24
R-600A Specifications & Handling
Gloves and Eye Protection must be used.
,.,
. ·
‘
R-600a is considered non-toxic, but is flammable when mixed with air.
Keep a dry powder type fire extinguisher in the work area.
RISK Of FIRE OR EXPLOSION. FLAMMABLE REFRIGERANT USED. TO BE REPAIRED ONLY BY
TRAINED SERVICE PERSONNEL DO HOT PUNCTURE REFRIGERANT TUBING
RISK Of FIRE OR EXPLOSION. FIAMHA_BLE REFRIGERANT USED. CONSULT REPAIR
IIANUAVOWHER’S GUIDE BEFORE ATTEMPTING TO SERVICE THIS PRODUCT. ALL SAFETY
PRECAUTIONS HUST BE FOUOWEO. RISK Of FIRE OR EXPLOSION. DISPOSE Of PROPERTY IN
ACCORDANCE WITH FEDERAL OR LOCAL REGULATIONS. FLAHHABLE REFRIGERANT USED.
R-600A Specifications
R-600a is heavier than air, do not allow any leakage/migration to low areas
such as basements and stairs.
Never use a torch on a fully charged refrigeration system.
Never substitute Marvel OEM replacement parts or methods of construction.
R-600a must be stored and transported in appro ved containers.
25
I IA WARNING
Only skilled and well trained service technicians permitted to service R-600a
equipped products.
All tools and equipment must be approved for use with R-600a refrigerant.
Local, state and federal laws, standards must be observed along with proper
certification and licensing.
Ventilation is required during servicing.
No conversions to R-600a from any other refrigerants. OEM R-600a equipped unit
only.
Service area must be free of ignition sources.
No smoking is allowed in the service area.
All replacement electrical components must be OEM and installed properly
(sealed and covered).
If the evaporator is cold prior to service, it must be thawed prior to
service.
When using a vacuum pump, start pump before opening refrigeration system.
Vacuum pump and recovery equipment should be at least 10 feet from the work
area.
It is recommended that a simple LPG gas detector is on site during service.
Ensure that all R-600a is removed from the system prior to brazing any part of
the sealed system.
Only a clean, dry leak free system should be charged with R-600a.
R-600A SPECIFICATIONS/LABELING R-600a equipped products are labeled (both the
unit and the compressor).
R-600a is colorless and odorless.
R-600a is considered non-toxic, but is flammable when mixed with air.
Do not remove or alter any R-600a labeling on the product.
Use only a refrigerant grade R-600a from a properly labeled container.
RECOVERING/RECLAIMING R-600A (R-600a has been exempted from
recovery/reclaiming requirements by the US EPA)
Recovery/Reclaiming equipment must be approved for use with R-600a.
Ensure the evaporator is at room temperature prior to recovery/reclaiming
R-600a.
Use a common piercing pliers or piercing valve to remove R-600a from the
compressor process tube. (Note: Piercing devices must not be lelt on the
system and must be replaced with a Schrader type valve.)
R-600A Specifications
26
Evacuate/reclaim via the piecing pliers to ensure the system is empty of
R-600a before any system work is performed.
GAS LEAi<
LOCATOII
The recovery cylinder must be evacuated (no air inside) prior to accepting
R-600a. The recovery cylinder must not be filled more than 45% safe fill level
and refrigerants must not be mixed. The recovery cylinder must be clearly
marked with R600a and Flammable Warning labels.
Ensure proper ventilation during recovery/reclaiming of R600a. Start vacuum
pump/recovery pump prior to piercing the compressor process tube.
Follow recovery/reclaim OEM instructions for the specific equipment used.
SYSTEM REPAIR Ensure no residual R-600a refrigerant is left within the system
prior to repair (simple venting is not sufficient).
Evacuate and charge with dry nitrogen for leak checks.
Repair leaks or replace system parts as required.
When re-brazing, the system must be purged with dry nitrogen and at least one
access point open to the atmosphere. When re-brazing, proper ventilation is
required along with constant monitoring for the presence of R600a refrigerant.
The filter dryer must be replaced any time the sealed system is serviced. No
system should be open to the atmosphere for longer than 15 minutes to avoid
moisture migration into the system components. LEAK DETECTION After removal of
the R-600a, the unit can be charged with dry nitrogen or helium. Electronic
leak detection or soap solution can be used to check for nitrogen/helium
leaks.
Never use a halide torch or lighted match to check the system for leaks at any
time. The high side of the refrigeration system (compressor discharge to
outlet of drier) must be leak tested with the compressor running.
R-600A Specifications
27
The low side of the refrigeration system (evaporator, compressor and suction
line) must be leak tested with the compressor off (equalized pressure).
RECHARGING No air is ever to be allowed inside the refrigeration system
(R-600a refrigerant or dry nitrogen only).
Never use a torch on a fully charged refrigeration system.
Install a Schrader Type access port on the compressor process stub.
Proper ventilation during service is required.
Never apply a torch to a charged R-600a refrigeration system.
Use OEM replacement service parts and do not alter the construction of the
unit.
Evacuate the system to 100 microns prior to charging.
Weigh in the R-600a charge using a refrigerant scale. (run compressor an extra
two minutes to clear the charging hoses).
Seal the Schrader Type access port, a proper cap and seal must be used to
close the system.
SUMMARY Safely handling R-600a requires proper procedures and training.
R-600a approved service tools must be used.
R-600a labeling must not be removed or altered.
R-600A Specifications
28
COMPRESSOR SPECIFICATIONS
! WARNING
Electrocution can cause death or serious injury. Burns from hot or cold
surfaces can cause serious injury. Take precautions when servicing this unit.
Disconnect the power source.
Do not stand in standing water when working around electrical appliances.
Make sure the surfaces you touch are not hot or frozen.
Refrigerant Voltage Frequency Run Cap Start Winding Run Winding LRA FLA Starting Device Overload
Check Terminal Pins
To measure the start winding resistance, measure across the C and S pins.
To measure the run winding resistance, measure across the C and R pins.
Also check S to R and you should get the sum of the run and start windings.
To ensure the windings are not shorted, check the S and R to ground.
HYS67MGU72a
R600a 115 – 127 VAC 60 Hz 8F/450 VAC 8 Ohm at 77°F 7.1 Ohm at 77°F 11 A 7.6 A
QP2-4R7 DRB26p61A1
29
HOUSEHOLD PRODUCT WARRANTY
Marvel Refrigeration (Marvel) Limited Warranty
ONE YEAR LIMITED PARTS & LABOR WARRANTY For one year from the date of original
purchase, this warranty covers all parts and labor to repair or replace any
part of the product that proves to be defective in materials or workmanship.
For products installed and used for normal residential use, material cosmetic
defects are included in this warranty, with coverage limited to 60 days from
the date of original purchase. All service provided by Marvel under the above
warranty must be
performed by a Marvel factory authorized servicer, unless otherwise specified
by Marvel. Service provided during normal business hours.
TWO YEAR LIMITED PARTS & LABOR WARRANTY (MARVEL PROFESSIONAL PRODUCTS) For two
years from the date of original purchase, this warranty covers all parts and
labor to repair or replace any part of the product that proves to be defective
in materials or workmanship. For products installed and used for normal
residential use, material cosmetic defects are included in this
warranty, with coverage limited to 60 days from the date of original purchase.
All service provided by Marvel under the above warranty must be performed by a
Marvel factory authorized servicer, unless otherwise specified by Marvel.
Service provided during normal business hours.
AVAILABLE THIRD YEAR LIMITED WARRANTY (MARVEL PROFESSIONAL PRODUCTS) For
designated Marvel Professional product, Marvel offers a one year extension of
the two year warranty coverage from the date of purchase, free of charge. To
take advantage of this third year warranty, you must register your product
with Marvel within 60 days from the date of purchase at
marvelrefrigeration.com and provide proof of purchase. Nugget Ice Machine
proof of purchase must include the purchase of an in-line water filter
and filter head to qualify for this additional limited warranty.
LIMITED FIVE YEAR SEALED SYSTEM WARRANTY For five years from the date of
original purchase, Marvel will repair or replace the following parts, labor
not included, that prove to be defective in
materials or workmanship: compressor, condenser, evaporator, drier, and all
connecting tubing. All service provided by Marvel under the above warranty
must be performed by a Marvel factory authorized servicer, unless otherwise
specified by Marvel. Service provided during normal business hours.
WARRANTY TERMS
These warranties apply only to products installed in any one of the fifty
states of the United States, the District of Columbia, or the ten provinces of
Canada. The warranties do not cover any parts or labor to correct any defect
caused by negligence, accident or improper use, maintenance, instal-
lation, service, repair, acts of God, fire, flood or other natural disasters.
The product must be installed, operated, and maintained in accordance with the
Marvel User Guide.
The remedies described above for each warranty are the only ones that Marvel
will provide, either under these warranties or under any warranty arising by
operation of law. Marvel will not be responsible for any consequential or
incidental damages arising from the breach of these warranties or any other
warranty, whether express, implied, or statutory. Some states do not allow the
exclusion or limitation of incidental or consequential
damages, so the above limitation or exclusion may not apply to you. These
warranties give you specific legal rights, and you may also have other rights
which vary from state to state.
Any warranty that may be implied in connection with your purchase or use of the product, including any warranty of merchantability or any war-
ranty fit for a particular purpose is limited to the duration of these warranties, and only extends to five years in duration for the parts described
in the section related to the five year limited warranty above. Some states do not allow limitations on how long an implied warranty lasts, so the
above limitations may not apply to you.
·
The warranties only apply to the original purchaser and are non-transferable.
·
The second, third, and five year warranties cover products installed and used for normal residential use only.
·
The warranties apply to units operated outside only if designed for outdoor use by model and serial number.
·
Replacement water filters, light bulbs, and other consumable parts are not covered by these warranties.
·
The start of Marvel’s obligation is limited to four years after the shipment date from Marvel.
·
In-home instruction on how to use your product is not covered by these warranties.
·
Food, beverage, and medicine loss are not covered by these warranties.
·
If the product is located in an area where Marvel factory authorized service is not available, you may be responsible for a trip charge or
you may be required to bring the product to a Marvel factory authorized service location at your own cost and expense.
·
Units purchased after use as floor displays, and/or certified reconditioned units, are covered by the limited one year warranty only and
no coverage is provided for cosmetic defects.
·
Signal issues related to Wi-Fi connectivity are not covered by these warranties.
For parts and service assistance, or to find Marvel factory authorized service
near you, contact Marvel Refrigeration: MarvelRefrigeration.com ·
techsupport@MarvelRefrigeration.com · +616.754.5601
1260 E. Van Deinse St., Greenville, MI 48838
30
Marvel Refrigeration
1260 E. Van Deinse St. Greenville MI 48838
616.754.5601
www.marvelrefrigeration.com
All specifications and product designs subject to change without notice. Such
revisions do not entitle the buyer to corresponding changes, improvements,
additions, replacements or compensation for previously purchased products.
31
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>