Blue White F-300S,F-300SL Flowmeter Sensor Installation Guide

September 23, 2024
Blue-White

Blue White F-300S,F-300SL Flowmeter Sensor

Specifications

  • Voltage: 100 VAC or VDC
  • Current: Abs. Max. 0.250 Amp AC/DC
  • Power: Abs. Max. 5 Watts Max.
  • Contact Configuration: N.O. A, SPST
  • Form: PVDF, Black
  • Housing Material: PVDF, Black
  • Lead type: Red & Black, #24 Gage, 5 feet

Dimensions

  • A: 0.26 (6.6mm)
  • B: 2.8 (71mm)
  • C: 1.3 (33mm)
  • D: 1.3 (33mm)

Installation

  1. Loosen the Lock Screw (Thumb Screw) by rotating it counter-clockwise to allow the sensor to slide over the top of the F-300 flowmeter easily.
  2. Slide the sensor to the desired location on the flowmeter body.
  3. Secure the sensor in place by tightening the Lock Screw (rotate clockwise).

Flow Switch
The sensor contact is closed when the top of the float is inside the Alarm Trigger Zone (Hysteresis).
The sensor contact is open when the top of the float is outside of the Alarm Trigger Zone.

Flow Rate
If the float leaves the Alarm trigger zone, a built-in contact closure switch can remotely turn on/off a chemical pump and/or other external devices.

Frequently Asked Questions (FAQ)

  1. How do I know if my F-300 model is compatible with the flow sensor?
    F-300S is compatible with models 1.5 – 4, while F-300SL is compatible with models 1 – 1.25.

  2. What should I do if my pool water contains metallic particles?
    If your pool water contains metallic particles from rust or stainless steel exposed to chlorine, you may need to clean the F-300 flow meter more frequently.

Check F-300 models to ensure flow switch / flow rate sensor is compatible. F-300 flow meter float must be replaced with provided magnetized Yellow Float.

Note: F-300 may require more frequent cleaning if pool water contains metallic particles from rust or from stainless steel exposed to chorine.
How do you know if your model F-300 is compatible for use with flow sensor?

  • F-300S is compatible with 1.5” – 4” models.
  • F-300SL is compatible with 1” – 1.25” models.

Specifications

Voltage 100 VAC or VDC Abs. Max.
Current 0.250 Amp AC/DC Abs. Max.
Power 5 Watts Max.
Contact Configuration N.O.
Form A, SPST
Housing Material PVDF, Black
Lead type Red & Black, #24 Gage, 5 feet

Dimensions

Approx. trigger range: Contact will trigger (close) when magnetic float present (within range A).

A 0.26” (6.6mm)
B 2.8” (71mm)
C 1.3” (33mm)
D 1.3” (33mm)

Circuit Diagram

High surge currents may cause damage to the sensor and significantly reduce its life, the following circuit is, therefore, highly recommended.

VOLTAGE @ Max AMP. (V) Minimum R (OHM) +-  20%
30 DC/AC @ .033 AMP. 1000
--- ---
24 DC/AC @ .040 AMP. 680
12 DC/AC @ .083 AMP. 150
6 DC/AC @ .166 AMP. 36
4 DC/AC @ .250 AMP. 16

www.Blue-White.com

Installation
Lock Screw (Thumb Screw) should be loosened (counter clockwise) so the sensor can slide with ease over the top of the F-300 flowmeter. Slide to desired location on flowmeter body. Secure with Lock Screw by tightening (rotate clockwise).  Sensor contact is closed when top of float is inside the Alarm Trigger Zone (Hysteresis)  Sensor contact is open when top of float is outside of the Alarm Trigger Zone
4.1) Flow Switch: See Figure 1
4.1) Flow Rate: See Figure 2

Flow Switch Figure 1

If float leaves “Alarm trigger zone,” a built-in contact closure switch can remotely turn on/off a chemical pump and/or other external devices.
With sensor installed all the way down, the switch can detect a flow / no flow situation.

Flow Rate Figure 2

With flow rate sensor installed at targeted flow rate, the sensor can detect if your flow is within desired range.
Flow Sensor can be moved to any position along scale. Tighten Lock Screw with fingers to secure position.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals