caple KAR-CO Coloured Stainless Steel Tap Instruction Manual
- May 15, 2024
- caple
Table of Contents
caple KAR-CO Coloured Stainless Steel Tap
Specifications
- Model Codes : KAR/CO, KAR/GD, KAR/GM, KAR/BS
- Customer Care Helpline: 0117 938 1900
- Websit e: www.caple.co.uk
- Guarantee : 5 years
Product Usage Instructions
Installation Instructions
- Turn the tap so it faces forward with the hot water connection on the left.
- Flush hot and cold pipes thoroughly to remove debris.
- A 35mm hole is required in the sink or worktop.
- Screw the fixing bolt into the tap base without damaging the threads.
- Place the rubber washer over the fixing bolt flush to the bottom.
Care of Your Taps
- Clean with soap or mild liquid detergent and water, then dry with a soft cloth.
- Avoid chemical cleaners or bleach-based solutions.
- Avoid abrasive cleaners, liquids, powders, or pads.
Pre-Installation Checks
- Ensure the hot water supply temperature does not exceed the maximum pressure of 5 bar.
- Seek advice from a qualified installer.
Post Installation Points
- Use PTFE tape on screw connections before fully tightening.
- Check for leaks before use and flush hot and cold water to remove dislodged particles.
These instructions are intended as a guide. If in doubt, seek advice from a certified plumber.
FAQ
- Q: What should I do if I encounter leaks after installation?
- A: Check the connections, ensure they are tight, and if needed, reapply PTFE tape before tightening. If leaks persist, contact customer care.
- Q: Can I use abrasive cleaners on the tap surface?
- A: No, abrasive cleaners can damage the finish and void the guarantee. Only use soap or mild detergent with water for cleaning.
INSTALLATION GUIDE
Thank you for purchasing your Caple Tap. These taps have been manufactured and inspected to exacting standards and are guaranteed to give years of trouble- free operation providing our care and installation guidelines have been followed.
NOTE: Please see back page for installation instructions
INSTALLATION INSTRUCTIONS
- Turn the spout and body so the tap is facing forwards, the screw on the spout indicates the rear of the body. The hot water connection should be on the left of the tap.
- Ensure the hot and cold pipes are thoroughly flushed to remove any debris.
- A 35mm hole is required in either the sink or worktop.
- The fixing bolt must be screwed into the tap base, ensuring the threads of the bolt are not damaged in the process.
- Pass the rubber washer over the fixing bolt flush to the bottom of the tap base, then pass the bolt through the sink or worktop (ensuring the nylon washer remains directly under the tap base).
- Pass the rubber washer and then the metal washer (on the underside of the sink/worktop) over the fixing bolt and fix using the fixing nut.
- Screw the flexi-tail pipes into the base of the tap, ensuring the pipe threads are not damaged in the process. If the flexi-tails are already inserted into the tap base, please ensure these are screwed in tightly to prevent any leaks.
- Finally, connect the flexi-tail pipes to the hot and cold supplies ensuring they are connected to the correct supplies.
CARE OF YOUR TAPS
- Only clean your taps with soap or mild liquid detergent and clean water then dry using a soft cloth
- Do not use chemical cleaners, or bleach-based solutions to clean your tap, contact could affect the finish of your tap.
- Do not use abrasive cleaners, liquids, powders or pads. These will damage the finish of your tap and void the guarantee.
- Provided all of the above points are adhered to the surface finish of your Caple Tap is guaranteed for 5 years.
PRE INSTALLATION CHECKS
- The temperature of the hot water supply must not exceed 70°C.
- Water pressure requirements: The minimum required pressure varies depending on the model, the maximum pressure is 5 bar.
- Always seek advice from a qualified installer to ensure your installation and water supply to your taps comply with the water regulation (WRAS) requirements and good plumbing practices.
- It is good practice to ensure that both hot and cold water supplies to your tap are of equal pressure to provide a consistent flow. If supplies are not of equal pressure then a non-return valve should be fitted on the hot inlet.
- Supplies of water should be from a common source (mains or tank fed).
- We recommend that a service valve is installed in the supply lines to the tap to enable water isolation if required.
POST-INSTALLATION POINTS
- We suggest when connecting screw connections that PTFE tape is used before the joints are fully tightened.
- Before use correctly check the installation for leaks, and turn the hot and cold water on to thoroughly flush any small particles that may have been dislodged during the tap installation.
THESE INSTRUCTIONS ARE INTENDED AS A GUIDE, IF IN ANY DOUBT ENSURE YOU SEEK ADVICE FROM A CERTIFIED PLUMBER.
GUARANTEE
- Your Caple tap is guaranteed for 5 years.
- Should you have any defects as detailed above during the appropriate guarantee period we guarantee to repair or replace the defective products or parts, or, at our option refund the purchase price assuming we were advised immediately of any claim in writing.
- You must keep proof of purchase (such as your receipt) to facilitate your guarantee.
TERMS AND CONDITIONS
- Guarantee conditions are only valid if the Care guidelines listed above are followed.
- Our obligation under the guarantee is to the original purchaser, and may not be transferred.
- The guarantee is valid for UK domestic installations only and relates to defects in manufacture, materials and workmanship only.
- Issues that arise due to normal wear and tear (for example valves, discs or washers), poor installation, improper use or accidental damage are not covered by the Caple guarantee. Spare parts can be purchased from our Customer care helpline 0117 938 1900.
- No liability is accepted for consequential damage to other household fixtures, fittings or furnishings relating to any claim – even it is attached to the product.
- If it is more economically viable a replacement tap will be supplied, this tap might vary from the original design should range changes of occurred since the initial supply.
- We reserve the right to inspect any tap before committing to support under the guaranteed conditions.
contact
- Customer care helpline:
- 0117 938 1900
- www.caple.co.uk
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>