caple VAP2 Steaming Water Tap Instruction Manual
- June 1, 2024
- caple
Table of Contents
- SAFETY INSTRUCTIONS
- IMPORTANT
- ACCESSORIES SUPPLIED
- INSTALLING THE VAPOS 3IN1 STEAMING HOT WATER TAP
- VAPOS 3IN1 INSTALLATION
- INSTALLING THE JOYA 3IN1 STEAMING HOT WATER TAP
- JOYA 3IN1 INSTALLATION
- OPERATION
- BOILER HEATING TIME
- TAP DIMENSIONS
- BOILER TECHNICAL SPECIFICATION
- CARE AND MAINTENANCE
- TROUBLESHOOTING
- CUSTOMER SUPPORT
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
caple VAP2 Steaming Water Tap
Contact Caple on 0117 938 7420 for spare parts or www.caple.co.uk
SAFETY INSTRUCTIONS
This steaming hot water tap is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the
appliance.
Cleaning and user maintenance must not be made by children without
supervision.
This appliance is intended to be used in household and similar applications
such as:
- Staff kitchen areas in shops, offices and other working environments.
- Farm Houses.
- By clients in hotels, motels and other residential type environments.
- Bed and breakfast type environments.
To avoid all risk, if the plug or power cable is damaged, it must only be replaced by a Caple appointed engineer.
Do not wash children, hair or any pets in a sink within reach of this steaming water tap. Although there are safety features in place, the steaming water could cause scalding by release of near boiling water.
This appliance can be used by children aged from 8 years and above if they
have been given supervision or instruction concerning use of the appliance in
a safe way and if they understand the hazard involved.
Cleaning and user maintenance must not be made by children unless they are
older than 8 and supervised. Keep the appliance and its cord out of the reach
of children aged less than 8 years.
Appliances can be used by persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have been given
supervision or instruction concerning use of the appliance in a safe way and
understand the hazards involved.
Children must not play with this appliance.
When not in use and before cleaning, always unplug the appliance.
IMPORTANT
Read the instruction manual carefully before using the appliance for the first
time.
This appliance is designed solely to dispense hot and cold water, also to
dispense near boiling water. Other types of use are not permitted and may
prove dangerous. Caple will not be held liable for any damage caused by the
incorrect use of the appliance.
Do not use any accessories or attachments not recommended by Caple as this may
result in fire, electric shock or injury.
To protect against fire, electrical shock and injury to persons, do not
immerse cord or plugs in water or any other liquid.
Never touch the under-counter parts of the appliance with wet or damp hands.
Never touch the plug with wet or damp hands.
Make sure the socket used is freely accessible at all times, enabling the
appliance to be unplugged when necessary. Unplug directly from the plug only.
Never pull the power cable as you could damage it.
If the appliance is faulty, do not attempt to repair it.
Unplug from the mains electric socket and contact Caple Service either by
phone 0117 938 7420 or email service@caple.co.uk.
Keep all packaging (including plastic bags, polystyrene foam etc) out of the
reach and away from children.
This appliance produces very hot, near boiling water and steam may form while
it is in operation. Avoid contact with splashes of hot water or hot steam.
Always follow the instructions and use the lever handles to control the
product.
Do not rest large or unstable objects on any part of the appliance.
Do not rest vessels containing liquids, inflammable or corrosive materials on
top of any part of the appliance.
IMPORTANT
Caple cannot be held responsible for injuries or losses caused by incorrect use or installation of this product. Please note that Caple reserve the right to invalidate the guarantee supplied with this product following incorrect installation or misuse of the appliance. The guarantee may become void in the event of the water filter not being replaced at the required six month intervals or it not being set to the correct setting as outlined in the filter installation instructions. Under no circumstances should any external covers be removed for servicing or maintenance except by suitably qualified personnel.
ENVIRONMENTAL PROTECTION
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your Local Authority or retailer for recycling advice. This appliance is marked according to the European directive on Waste Electrical and Electronic Equipment (WEEE).
By ensuring this product is disposed of correctly, you will help prevent
potential negative consequences for the environment and human health, which
could otherwise be caused by inappropriate waste handling of this product. The
symbol on the product indicates that this product may not be treated as
household waste. Instead it shall be handed over to the applicable collection
point for the recycling of electrical and electronic equipment. Disposal must
be carried out in accordance with local environmental regulations for waste
disposal.
For more detailed information about treatment, recovery and recycling of this
product, please contact your local council, your household waste disposal
service or the retailer where you purchased the product.
WARRANTY
Your new appliance is covered by warranty. The warranty card is enclosed – if it is missing, you must provide the following information to your retailer in order to receive a replacement: date of purchase, model and serial number. Registration can also be completed online by visiting www.caple.co.uk.
Ensure you keep your warranty card safe, you may need to show it to Caple
Service together with proof of purchase. If you fail to show your warranty
card you will incur all repair charges.
Spare parts are only available from Caple Service and spare parts authorised
centres.
CE DECLARATIONS OF CONFORMITY
This appliance has been manufactured to the strictest standards and complies
with all applicable legislation, Low Voltage Directive (LVD) and
Electromagnetic Compatibility (EMC).
UKCA DECLARATIONS OF CONFORMITY
This appliance has been manufactured to the strictest standards and complies
with all applicable legislation.
ACCESSORIES SUPPLIED
You will receive 3 separate boxes for this product:
- Tap
- BOILER2 – boiler tank
- PURITI7 – Filter and fixings
The contents of the boxes should be as follows:
TAP
- 1 x Tap and relevant fixings (including all flexi tails for hot, cold and boiling water connections)
BOILER
- 1 x Boiler
- 1 x Steam release valve
- 1 x Flexi tail for boiler inlet
- 1 x Clear silicone steam release tube with threaded metal connector for plumbing
- 1 x Instruction book
- 1 x Hanging Plate
INCLUDED IN THE PURITI7 FILTER BOX:
- 1 x T-piece connector for main cold water to supply
- 1 x Push fit to thread adaptor
- 1 x Claris Ultra filter with installation guide
- 1 x Adjustable filter head and fittings
- 1 x Blue tube for cold water supply to filter
- 2 x Water hardness testing strips
INSTALLING THE VAPOS 3IN1 STEAMING HOT WATER TAP
- In order to prevent an electric shock, do not place electrical wires, plugs or the dispenser in a wet or damp location.
- If any cables or sockets have signs of damage, do not connect the appliance to the power supply. These should be replaced by a Caple Service agent.
- When installing the dispenser, you should allow 10 to 15cm of space around it for ventilation.
- You must never use a spare part which is not recommended by Caple.
- The temperature adjustment controls the water temperature, not the water flow.
- Do not ‘dry heat’ the water tank as this can cause heating of the pipes and the water tank will become damaged. You must ensure the tank has been filled with water before switching the boiler on at the mains.
VAPOS 3IN1 INSTALLATION
- The power outlet must be correctly earthed and also be able to be isolated by a switch.
- Use a separate circuit for the boiler, which is also correctly earthed.
- The tap can be installed into the sink or the worktop using a 35mm hole.
- Install the water boiler vertically, it must not be placed on its side. It can be stood on the base of the cabinet, but it is recommended to fix the boiler in position using the brackets provided.
INSTALLATION STEPS
-
Install the tap onto the sink or the worktop as shown below, and tighten the fixing screw.
-
Screw the 3 flexible hoses into the base of the tap. The red hose connects to the hot water, the blue hose connects to the cold water, and the longer plain steel hose (1 meter) connects to the boiling water.
-
Attach the T-piece connector to the Cold mains water supply, to allow a seperate flow to go direct to the water filter. Using the Blue tube supplied with the filter, cut it to the appropriate length and connect this to the T-piece connecter via the push fit connection. The opposite end can then be attached to the inlet on the filter head.
-
Follow the instructions supplied with the filter and filter head to ensure it is installed correctly, and set to the correct setting for the water hardness in your area. Failure to do this will invalidate your guarantee.
-
The hot & cold tap tails can be connected directly to the hot & cold mains water, and the boiling water flexi tail can connect to the outlet on the top of the boiler.
-
Attach the Boiler inlet flexi tail onto the valve on the side of the boiler, and finally, using the remainder of the blue tube, connect this to the filter head outlet and then to the end of the Boiler inlet flexi tail using the push fit to threaded adaptor.
-
The clear silicone hose connects to the steam release valve on the side of the boiler, and can then be attached to the existing plumbing using the threaded metal connector.
-
Once all of the connections have been made, turn on the standard cold/hot water supply by using the right hand lever on the tap to test the cold water (blue colour indicator) and hot water (red colour indicator). Switch it off after the flow becomes normal.
-
Turn on the left lever of the tap (with child safety lock, push the lever down and backwards), until the water completely fills the boiler tank and begins to flow from the tap continuously. Let the water flow for at least 5 minutes in order to flush the tubes, boiler and filter.
-
Check all connections to ensure that no tubes are stretched or twisted and there are no leakages, then fix the boiler in the final location using the brackets supplied. The boiler must be installed upright.
- To fix the boiler to the cabinet, remove the hanging plate from the packaging:
- Mark the fixing location of the hanging bracket on the inside of the cabinet and install the bracket fixing screws into the cabinet.
- Using the nut and thread on the top of the boiler, fit the bracket.
- Fix the boiler in position by locating the bracket on the screws previously fixed into the cabinet.
- Tighten all screws to securely fix in place.
-
Connect the boiler to the power supply.
(PLEASE ENSURE THE BOILER TANK IS FULL OF WATER BEFORE SWITCHING ON, ANY DAMAGE CAUSED BY NOT FOLLOWING THIS INSTRUCTION WILL NOT BE COVERED BY THE GUARANTEE). -
Test the dispenser. Adjust the temperature of the boiler to the highest setting, wait for 10 minutes until you can hear the water boiling. The ‘HEATING’ light will illuminate whilst the boiler is heating. Once it has reached the desired temperature, ‘READY’ will be displayed.
NOTE:
It may take a few seconds for the water to begin to flow as it makes the way
up the tube (the time will vary depending on the length of the tube). Always
allow the water to run for a few seconds before using the steaming water to
make a drink. This will ensure any water which may have cooled in the tube has
been expelled first, allowing for a steaming hot beverage to be made.
INSTALLING THE JOYA 3IN1 STEAMING HOT WATER TAP
- In order to prevent an electric shock, do not place electrical wires, plugs or the dispenser in a wet or damp location.
- If any cables or sockets have signs of damage, do not connect the appliance to the power supply. These should be replaced by a Caple Service agent.
- When installing the dispenser, you should allow 10 to 15cm of space around it for ventilation.
- You must never use a spare part which is not recommended by Caple.
- The temperature adjustment controls the water temperature, not the water flow.
- Do not ‘dry heat’ the water tank as this can cause heating of the pipes and the water tank will become damaged. You must ensure the tank has been filled with water before switching the boiler on at the mains.
JOYA 3IN1 INSTALLATION
- The power outlet must be correctly earthed and also be able to be isolated by a switch.
- Use a separate circuit for the boiler, which is also correctly earthed.
- The tap and handles can be installed into the sink or the worktop using 35mm cutout holes.
- Install the water boiler vertically, it must not be placed on its side. It can be stood on the base of the cabinet, but it is recommended to fix the boiler in position using the brackets provided.
INSTALLATION STEPS
-
Install the tap onto the sink or the worktop as shown below, and tighten the fixing screw.
-
Screw the Hot & Cold flexi hoses into the base of the hot & cold handle. The red hose connects to the hot water, the blue hose connects to the cold water. The boiling water flexible hose connects to the base of the boiling water handle. Each handle then needs to be connected to the spout via the additional flexi hoses, as shown in the diagram here:
-
Attach the T-piece connector to the Cold mains water supply, to allow a seperate flow to go direct to the water filter. Using the Blue tube supplied with the filter, cut it to the appropriate length and connect this to the T-piece connecter via the push fit connection. The opposite end can then be attached to the inlet on the filter head.
-
Follow the instructions supplied with the filter and filter head to ensure it is installed correctly, and set to the correct setting for the water hardness in your area. Failure to do this will invalidate your guarantee.
-
The hot & cold tap tails can be connected directly to the hot & cold mains water, and the boiling water flexi tail can connect to the outlet on the top of the boiler.
-
Attach the Boiler inlet flexi tail onto the valve on the side of the boiler, and finally, using the remainder of the blue tube, connect this to the filter head outlet and then to the end of the Boiler inlet flexi tail using the push fit to threaded adaptor.
-
The clear silicone hose connects to the steam release valve on the side of the boiler, and can then be attached to the existing plumbing using the threaded metal connector.
-
Once all of the connections have been made, turn on the standard cold/hot water supply to test the cold water (blue colour indicator) and hot water (red colour indicator). Switch it off after the flow becomes normal.
-
Turn on the Boiling water supply (with child safety lock, push the button in and backwards), until the water completely fills the boiler tank and begins to flow from the tap continuously. Let the water flow for at least 5 minutes in order to flush the tubes, boiler and filter.
-
Check all connections to ensure that no tubes are stretched or twisted and there are no leakages, then fix the boiler in the final location using the brackets supplied. The boiler must be installed upright. To fix the boiler to the cabinet, remove the hanging plate from the packaging:
- Mark the fixing location of the hanging bracket on the inside of the cabinet and install the bracket fixing screws into the cabinet.
- Using the nut and thread on the top of the boiler, fit the bracket.
- Fix the boiler in position by locating the bracket on the screws previously fixed into the cabinet.
- Tighten all screws to securely fix in place.
- Connect the boiler to the power supply (please ensure the boiler tank is full of water before switching on, any damage caused by not following this instruction will not be covered by the guarantee).
- Test the dispenser. Adjust the temperature of the boiler to the highest setting, wait for 10 minutes until you can hear the water boiling. The ‘HEATING’ light will illuminate whilst the boiler is heating. Once it has reached the desired temperature, ‘READY’ will be displayed.
NOTE:
It may take a few seconds for the water to begin to flow as it makes the way up the tube (the time will vary depending on the length of the tube). Always allow the water to run for a few seconds before using the steaming water to make a drink. This will ensure any water which may have cooled in the tube has been expelled first, allowing for a steaming hot beverage to be made.
OPERATION
Turn on the boiler press the button. To adjust the water temperature, press the arrows on the control panel to increase and decrease the temperature. The temperature can be adjusted from approximately 25°C to 98°C.
Turn on the boiler press the button. To adjust the water temperature, press the and arrows on the control panel to increase and decrease the temperature. The temperature can be adjusted from approximately 25°C to 98°C.
Vapos Press the lever downwards to release the safety lock, and then push
the lever backwards.
There is a safety spring mechanism which will switch off the water supply if
you let go of the lever. Please hold the lever back for the full time you need
to draw boiling water from the tank. Then release it to switch it off.
Joya Push the button at the rear of the handle inwards to release the
safety mechanism, and then turn the handle. There is a safety spring mechanism
which will switch off the water supply if you let go of the handle. Please
keep the handle fully twisted for the full time you need to draw boiling water
from the tank. Then release it to switch it off.
In order to guarantee the performance and quality of your steaming water tap, do not stretch the tubes after installation, take extreme care not to touch any of the tubes or fixings.
If the flow reduces this may be due to the filter needing replacement. The water filter must be replaced at least once every 6 months, failure to do this may invalidate the guarantee.
If the boiler is not going to be used for a long period of time, please turn
it off, and disconnect it from the power supply. Allow the steaming water to
flow from the tap until it runs cold.
When you are ready to use the boiler again, ensure you fill the tank
completely before connecting the boiler to the power supply and setting the
temperature control to the desired temperature setting. Failure to fill the
tank prior to switching on may cause damage and invalidate the guarantee.
It is important that the water filter is replaced at least every 6 months and
installed according to the instructions supplied with the filter. Failure to
correctly set the filter head to the correct setting or replace the filter
when required will affect the boilers performance and cause scale build-up,
this may invalidate the guarantee.
BOILER HEATING TIME
The below table shows the effect on the temperature of the water as water is drawn from the boiler. For example, if you take 1250ml of boiling water (enough for around 9 cups of tea) in one go, the remaining water in the boiler will drop to 96˚C and take around 245 seconds to heat back to 98˚C. ‘HEATING’ will illuminate on the temperature adjustment screen when the temperature drops below the set temperature. ‘READY’ will illuminate when it has heated back to the desired temperature.
TEMPERATURE ADJUST SWITCH:
MAX
| TEMPERATURE OF INLET WATER:
28˚C
| PRESSURE OF INLET WATER:
1.5 – 2BAR
---|---|---
| | | |
0| 0| 98| 0| READY
0-250| 5| 98| /| READY
0-500| 10| 98| /| READY
0-750| 15| 98| /| READY
0-1000| 20| 98| /| READY
0-1250| 25| 96| 245| HEATING
0-1500| 30| 96| 305| HEATING
0-1750| 35| 94| 330| HEATING
0-2000| 40| 94| 385| HEATING
0-2250| 45| 92| 440| HEATING
NOTE:
The above data is based on tested water taken directly from the boiler tank,
not the tap. The water temperature from the tap will be different dependent on
the length of the hose between the boiler and the tap.
TAP DIMENSIONS
VAP2/3IN1/SS
VAPQ2/3IN1/SS
JOYA/3IN1/SS
BOILER TECHNICAL SPECIFICATION
BOILER2
Rated Voltage: | 220-240V |
---|---|
Rated Frequency: | 50Hz |
Rated Power: | 1700W |
Rated Current: | 10A |
Capacity : | 3.5L |
Temperature Range: | 25-98˚C |
Minimum Water Pressure: | 0.5 |
Maximum Water Pressure: | 7 |
Power Consumption: | 0.89KWh/24H |
Inside Material: | Stainless Steel |
CARE AND MAINTENANCE
IMPORTANT:
You must not perform any care or maintenance on this product without first
switching off the power supply and disconnecting the boiler from the mains.
CLEANING
This product can be cleaned by simply using warm water with a small amount of
mild detergent added. Use a soft cloth (not a scouring pad as this will damage
the surface) and wipe the exterior of the boiler and tap. DO NOT use any
abrasive cream cleaners (including Cif and Cillit Bang), these cleaning fluids
can also damage the surface and remove the markings on the tank and tap
surface.
REPLACING THE FILTER
Replacing a filter cartridge:
-
Slowly unscrew the used cartridge by turning counter-clockwise. This will unlock it from the filter head and enable it to be removed. During this process, incoming tap water supply and outgoing filtered water valves in the filter head shut-off automatically.
The system will expand and a small amount of expansion water may escape from the flush hose due to peaks in pressure. Please keep this in mind and place a suitable container underneath the flush hose. -
Open the flush/pressure release valve (see figure 1) and lead the rinsing hose into a suitable container (e.g. bucket) or to the drain.
-
Remove the new filter cartridge from its packaging and check for any damage.
-
Insert the filter cartridge into the filter head and turn the cartridge clockwise until it stops and end position is reached. The flow in the filter head is reopened and the system vented and flushed via the flush/ pressure release valve. Flush filter for 10 litres.
-
Close the flush/pressure release valve (see figure 2) – the system is now ready for use.
-
After replacing the filter cartridge, check all components for seal integrity, water must not escape from any point.
NOTE:
The flush water will be milky or cloudy at first. This is due to the dispersing air and will clear up quickly after flushing the cartridges with appropriate volume of water. Now check that the cartridge position is correct by ensuring the mark on the filter cartridge aligns with the larger recession of the wall mounting bracket. When inserting the cartridge, check the position of the cartridge label. This should face forwards once in the end position so that all of the necessary information is visible.
For further information please refer to the manual supplied with your filter.
BOILER TEMPERATURE LIMITER
The Boiler is fitted with a Temperature Limiter which will automatically power off the unit if overheating is detected. To reset the Boiler, follow the below steps:
-
Turn off the power to the boiler and wait 40 minutes. This will allow the internal temperature to lower.
NOTE: If the full 40 minutes is not allowed, the reset process will not be possible. -
The reset button is located underneath the boiler.
-
Remove the cover by unscrewing it and press the reset button.
-
Re-install the cover for the reset button.
-
Fill water into the tank by turning the boiling water lever on the tap. Once full, turn the power back on.
TROUBLESHOOTING
Below is a table of possible malfunctions, this should help you to solve any problems without the need to contact Caple Service.
FAU LT | REASON | SOLUTION |
---|---|---|
E1 (Displayed on Boiler Screen) | Leakage of electricity. The electric | |
current is over 25mA which triggers the leakage protective device. | Turn off |
the power and contact Caple Service.
E2 (Displayed on Boiler Screen)| Tank heating without water inside. The
rate of temperature rising reaches 1°C/ Second, triggering the protective
device.| Turn off the power. Fill water into the tank by turning the boiling
water lever on the tap. Once full, turn the power back on.
E3 (Displayed on Boiler Screen)| Temperature sensor failure.| Turn off
the power and contact Caple Service.
WATER ICING IN THE TANK| Anti-freeze protection failure.
When the boiler is off, if the water temperature in the tank is below 4°C, the boiler will auto-start heating until the water temperature reaches 12°C.
| If the Anti-freeze protection does not solve this issue, turn off the power
and contact Caple Service.
HOT WATER OR STEAM ARE RELEASED FROM THE TAP WHEN NOT IN USE| The auto-
close system on the boiling water handle has malfunctioned and the lever has
not sprung back to the ‘off’ position.
The valve is leaking.| Replace the spring for auto-close handle system.
Replace the valve.
THE WATER IS NOT HOT| There is no power supply to the boiler. The boiler
is turned off.
The temperature has been set too low.
| Check the power supply. Check the boiler is turned on.
Turn the temperature setting up.
THE FLOW HAS REDUCED| Low mains water pressure.
The Puriti filter needs changing.
| Check the water pressure. Replace the water Puriti filter.
THERE IS NO WATER FLOW| The water valve may have been switched off.
The inlet pipes may be twisted.| The water valve may have been switched off.
The inlet pipes may be twisted.
FAU LT| REASON| SOLUTION
---|---|---
THE WATER DOES NOT FLOW IMMEDIATELY| The boiler tank is not full of
water.| Open the tap valve, wait a few minutes until the water fills the tank.
Once the tank is full, water will begin to flow out of the tap. It is normal
when first used for this to happen.
BOILER IS DEAD, AND NO LONGER WORKING| Temperature limiter is activated
due to overheating.| Reset temperature limiter via switch on bottom of the
boiler (see page 27 for further info)
If you have a problem which cannot be resolved by using the troubleshooting table please contact Caple Service, by telephone on 0117 938 7420 or by email at service@caple.co.uk
CUSTOMER SUPPORT
Caple Service
Fourth Way
Avonmouth
Bristol
BS11 8DW
T: 0117 938 1900
E: service@caple.co.uk
www.caple.co.uk
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>