EPH CONTROLS EDBS Electronic Cylinder Thermostat with High Limit Instruction Manual
- September 25, 2024
- EPH CONTROLS
Table of Contents
- EPH CONTROLS EDBS Electronic Cylinder Thermostat with High Limit
- Product Usage Instructions
- FAQ
- Factory Default Settings
- Specifications
- LCD Symbol / Button Description
- Mounting & Installation
- Installation Drawing
- Operating Instructions
- Setting the Date & Time
- Legionella Function
- Auto Lock Function
- High & Low-Temperature Limits
- Hysteresis Function
- High Limit Cut Out Temperature
- also available
- Contact
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
EPH CONTROLS EDBS Electronic Cylinder Thermostat with High Limit
Specifications
- Power supply: AC 200-240V, 50-60Hz
- Power consumption: Not specified
- Temperature control range: Not specified
- Ambient temperature: Not specified
- Admissible ambient humidity: Not specified
- Dimensions: Not specified
- Contact rating: Not specified
- Battery: Not specified
- Backlight: Available
- IP rating: Not specified
- Pollution degree: Not specified
- Rated impulse voltage: Not specified
- Automatic action: Not specified
- Temperature sensor: Not specified
- Temperature indication: LCD Display
Product Usage Instructions
Mounting & Installation
- The installation and connection should only be carried out by a qualified person.
- Loosen the screws on the back housing of the thermostat and remove it.
- Wire the thermostat following the Wiring Diagram provided on page 5 of the manual.
- Replace and tighten the back housing.
- Insert both cable sensors into the pocket.
- Secure the thermostat on the pocket by tightening the fixing screws.
Operating Instructions
Resetting the High Limit Thermostat
To reset the high limit thermostat:
- Remove the handwheel from the thermostat.
- Locate the reset button underneath the handwheel.
- Press the reset button to reset the thermostat.
Adjusting the Setpoint Temperature
- To adjust the temperature setpoint:
- Rotate the knob to adjust the temperature and press to confirm.
Setting the Date & Time
Double press the handwheel to enter the menu for setting date and time.
FAQ
Q: Can I replace the battery in the thermostat?
A: The manual does not specify battery replacement, please consult customer support for assistance with this issue.
Factory Default Settings
- Temperature indicator: °C
- Clock: 24 hours
- Day light saving: On
- Legionella function: Off
- Legionella set temperature: 65°C
- Auto lock: Off
- Backlight: Auto
- Maximum temperature setting: 80°C
- Minimum temperature setting: 10°C
- Hysteresis On: 5°C
- Hysteresis Off: 0°C
- High Limit Cut Out: 85°C – Not adjustable
Specifications
- Power supply: 230Vac 50-60Hz
- Power consumption: 1.8W
- Temperature control range: 10…80°C
- Ambient temperature: 0…45°C
- Admissible ambient humidity: 5-95%RH
- Dimensions: 100 x 105 x 42.5 mm
- Contact rating: 10A
- Battery: LIR 2032
- Backlight: Blue
- IP rating: IP20
- Pollution degree: Pollution Degree 2
- Rated impulse voltage: 4kV
- Automatic action: 1C
- Temperature sensor: NTC 10K @ 25°C
- Temperature indication: °C
LCD Symbol / Button Description
LCD Display
Button
Wiring
Caution!
- Mains voltage output only
Terminal Connections
- N/C Heat OFF
- N/O Heat ON
- L Live in from Mains Supply
- N Neutral in from Mains Supply
- COM Switch Live
Mounting & Installation
Caution!
- Installation and connection should only be carried out by a qualified person.
- Only qualified electricians or authorized service staff are permitted to open the thermostat.
- If the thermostat is used in a way not specified by the manufacturer, its safety may be impaired.
- Prior to setting the thermostat, it is necessary to complete all required settings described in the section.
The EDBS is designed to fit directly onto a hot water cylinder pocket.
- Loosen the 3 screws on the back housing of the thermostat.
- Remove the back housing.
- Wire the thermostat according to the Wiring Diagram on page 5.
- Replace the back housing and tighten the 3 screws.
- Insert both cable sensors into the pocket.
- Tighten the 3 fixing screws to ensure the thermostat is secured on the pocket.
Installation Drawing
Operating Instructions
Resetting the High Limit Thermostat
This thermostat consists of a control thermostat and a high limit thermostat.
The high limit thermostat has a maximum permissible temperature of 85°C. If
the high limit temperature is exceeded, the temperature will continuously
flash on the screen to alert you that a manual reset is required.
Manual reset is only possible after the temperature drops below 85°C.
To Reset the high limit thermostat
- Remove the handwheel from the thermostat.
- Note the location of the reset button underneath the handwheel.
- Reset the thermostat by pressing the reset button.
Adjusting the Temperature Setpoint
- Rotate to adjust the temperature setpoint.
- Press to confirm.
Setting the Date & Time
Double-press the handwheel to enter the menu will appear.
- Press once.
- Rotate to select the year.
- Press to confirm.
- Rotate to select the month.
- Press to confirm.
- Rotate to select the day.
- Press to confirm.
- Rotate to select the hour.
- Pres s to confirm.
- Rotate to select the minute.
- Press to confirm.
- Rotate to select daylight saving.
- Press to confirm and to return to the menu.
- Rotate to exit the menu .
- Press to confirm.
Alternatively, the menu will be exited after 20 seconds
Legionella Function
Legionella bacteria can thrive in hot water cylinders that have a water temperature of between 20°C and 50°C. The purpose of the Legionella function on this thermostat is to remove any threat of Legionella bacteria surviving by raising the temperature of the hot water in the cylinder above 60°C for a specific period of 1 hour. The legionella function on this thermostat will call to heat the hot water to a user-selected temperature of between 60°C & 70°C. Default is set at 65°C.
The Legionella function on this thermostat offers the user the following:
- Operation a maximum of once per day at a time chosen by the user.
- Operation from one to seven days a week.
- Temperature selection of between 60°C to 70°C.
- Temperature must reach the temperature required for a period of one hour.
It is best practice to activate the legionella function at a time of low or no demand on the hot water. For example: 3 a.m. When the legionella function is active the symbol will appear.
Setting the legionella function Off
- Double press the handwheel to enter the menu.
- Rotate to select the Legionella function. (Menu P02) will appear.
- Press once. “Off” will appear on the screen.
- Rotate to turn the Legionella function “On”.
- Press once to confirm. 65°C will flash on the screen.
- Rotate to select the desired temperature of between 60°C & 70°C.
- Press once to confirm. “03:00” will flash on the screen.
- Rotate to select the start time.
- Press once to confirm.
- MON” will flash. To select “MON”, rotate clockwise once.
- Rotate anti-clockwise once to skip “MON”.
- You can then choose to select or skip the other days of the week.
- Turn clockwise to Select or anti-clockwise to Skip.
- Press once to confirm and to return to the menu.
- Rotate to exit the menu .
- Press to confirm.
Alternatively, the menu will be exited after 20 seconds.
Auto Lock Function
- The Auto Lock function allows you to set an automatic handwheel lock for the thermostat.
- When activated, the thermostat will automatically lock if is not rotated or pressed for 5 minutes.
- You can lock or unlock the thermostat by pressing for 10 seconds
Setting the Auto Lock Function Off
Double-press the handwheel to enter the menu.
- Rotate to select the Auto-lock function. (Menu P03) will appear.
- Press once. “Off” will appear on the screen.
- Rotate to select “On”.
- Press once to confirm and to return to the menu.
- Rotate to exit the menu .
- Press to confirm.
- Alternatively, the menu will be exited after 20 seconds.
- To unlock the thermostat, press and hold for 10 seconds.
If Auto Lock function is not selected, it is still possible to lock or unlock the thermostat by pressing and holding for 10 seconds.
Backlight Mode Selection
There are 3 backlight settings available for selection:
- AUTO: Backlight stays on for 10 seconds after is pressed or rotated.
- ON: Backlight is permanently On
- OFF: Backlight is permanently Off
Setting the backlight: AUTO
Double-press the handwheel to enter the menu.
- Rotate to select the Backlight function. (Menu P04) will appear.
- Press once. “Auto” will appear on the screen.
- Rotate to select “On” or “Off”.
- Press once to confirm and to return to the menu.
- Rotate to exit the menu .
- Press to confirm.
Alternatively, the menu will be exited after 20 seconds.
High & Low-Temperature Limits
This function allows you to set the maximum and minimum temperatures for the thermostat.
Setting the Hi Lo function: High 80°C Low: 10°C
- Double press the handwheel to enter the menu.
- Rotate to select the Hi-Lo function. (Menu P05) will appear.
- Press once. “Hi” will appear on the screen.
- Rotate to select the maximum temperature.
- Press once to confirm. “Lo” will appear on the screen.
- Rotate to select the minimum temperature.
- Press once to confirm and to return to the menu.
- Rotate to exit the menu .
- Press to confirm.
Alternatively, the menu will be exited after 20 seconds
Hysteresis Function
The Hysteresis function allows you to set the switching differential of the thermostat when the temperature is both rising and falling. “HYS On” of 5°C means the thermostat will switch on if the temperature drops 5°C below the setpoint. “HYS Off” of 1°C means the thermostat will switch off if the temperature rises 1°C above the setpoint. Both Hysteresis On and Hysteresis Off can be adjusted from 0°C to 20°C.
Hysteresis Function
Setting the Hysteresis function: HYS On: 5°C & HYS Off 0°C
- Double press the handwheel to enter the menu.
- Rotate to select the Hysteresis function. (Menu P06) will appear.
- Press once. “HYS ON” will appear on the screen.
- Rotate to select the HYS ON temperature.
- Press once to confirm. “HYS OFF” will appear on the screen.
- Rotate to select the HYS OFF temperature.
- Press once to confirm and to return to the menu.
- Rotate to exit the menu .
- Press to confirm.
Alternatively, the menu will be exited after 20 seconds.
Calibrating the Thermostat
The calibration function allows you to calibrate the thermostat.
Setting the Calibration function:
- Double-press the handwheel to enter the menu.
- Rotate to select the Calibration function. (Menu P07) will appear.
- Press once. The current temperature is displayed.
- Rotate to select the required temperature.
- Press once to confirm and to return to the menu.
- Rotate to exit the menu .
- Press to confirm.
Alternatively, the menu will be exited after 20 seconds.
Legionella Check Function
This function allows you to check the last three times that the legionella function operated successfully. It is possible to check the date, time and the set legionella temperature for these three times.
Checking the legionella record
-
Double-press the handwheel to enter the menu.
-
Rotate to select the Legionella Check function. (Menu P08) will appear.
-
Press once. will appear.
-
This is the date and time of the last successful legionella operation.
-
Rotate clockwise.
-
will appear.
This is the temperature of the last successful legionella operation. -
Rotate clockwise.
-
will appear.
-
This is the date and time of the second last successful legionella operation.
-
Rotate clockwise.
-
will appear.
-
This is the temperature of the second last successful legionella operation.
-
Rotate clockwise.
-
will appear.
-
This is the date and time of the third last successful legionella operation.
-
Rotate the handwheel clockwise.
-
will appear.
-
This is the temperature of the third last successful legionella operation.
-
Press once.
-
Rotate to exit the menu .
-
Press to confirm.
Alternatively, the menu will be exited after 20 seconds
High Limit Cut Out Temperature
This function allows you to view the high limit cut out temperatures in the thermostat.
- Double press the handwheel to enter the menu.
- Rotate to select the Factory default function. (Menu P09)
- will appear.
- Press once.
- “NO” will appear on the screen.
- The high limit cut out temperature will appear on the screen.
- This is the factory default setting and is not adjustable.
- Press once to confirm and to return to the menu.
- Rotate to exit the menu .
- Press to confirm.
Alternatively, the menu will be exited after 20 seconds.
Factory Reset Function
This function allows you to restore the factory default settings in the thermostat.
- Double-press the handwheel to enter the menu.
- Rotate to select the Factory default function. (Menu P09)
- will appear.
- Press once.
- “NO” will appear on the screen.
- Rotate to select “YES”.
- Press once to confirm.
The thermostat will now reboot with the factory default settings.
also available
Electro – Mechanical Thermostats
Programmable Digital Thermostats
Non Programmable Digital Thermostats
Cylinder Thermostats
Contact
EPH Controls IE
- technical@ephcontrols.com
- www.ephcontrols.com/contact-us
- +353 21 471 8440
- Cork, T12 W665
EPH Controls UK
- technical@ephcontrols.co.uk
- www.ephcontrols.co.uk/contact-us
- +44 1933 322 072
- Harrow, HA1 1BD
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>