LSC REDBACK PATcH Pre Wired Patch Optional Test Module User Manual
- September 18, 2024
- LSC
Table of Contents
REDBACK PATCH
User Manual
REDBACK PATcH Pre Wired Patch Optional Test Module
Disclaimer
LSC Control Systems Pty Ltd has a corporate policy of continuous improvement,
covering areas such as product design and documentation. To achieve this goal,
we undertake to release software updates for all products on a regular basis.
In light of this policy, some detail contained in this manual may not match
the exact operation of your product. Information contained in this manual is
subject to change without notice.
In any event, LSC Control Systems Pty Ltd cannot be held liable for any
direct, indirect, special, incidental, or consequential damages or loss
whatsoever (including, without limitation, damages for loss of profits,
business interruption, or other pecuniary loss) arising out the use or the
inability to use this product for its intended purpose as expressed by the
manufacturer and in conjunction with this manual.
Servicing of this product is recommended to be carried out by LSC Control Systems Pty Ltd or its authorized service agents. No liability will be accepted whatsoever for any loss or damage caused by service, maintenance or repair by unauthorized personnel. In addition, servicing by unauthorized personnel may void your warranty.
LSC Control Systems products must only be used for the purpose for which they
were intended.
Whilst every care is taken in the preparation of this manual, LSC Control
Systems takes no responsibility for any errors or omissions.
Copyright Notices
“LSC Control Systems” is a registered trademark.
The contents of this manual are copyright of LSC Control Systems Pty. Ltd. ©
2020.
All Trademarks referred to in this manual are the registered names of their
respective owners.
lsccontrol.com.au is owned and operated by LSC
Control Systems Pty Ltd.
All rights reserved.
Contact Details
LSC Control Systems Pty. Ltd.
ABN 21 090 801 675
65-67 Discovery Road
Dandenong South, Victoria 3175 Australia
Tel: +61 3 9702 8000
email: info@lsccontrol.com.au
web: www.lsccontrol.com.au
Redback Patch System
1.1 About this Manual
This manual describes the Redback Patch Bays and Test Modules manufactured by
LSC Control Systems.
1.2 Redback Patch Bay Overview
The Redback Patch Bay is the most compact patch panel system available on the
market today.
The unique and clever design does not compromise on usability. The slimline
construction makes it ideal for mounting in small equipment rooms, on catwalks
or backstage areas. When the cables are not in use, they are neatly arranged
to avoid a potential trip hazard.
1.3 Patching
A typical theatrical lighting installation will consist of many lighting
outlets located at different locations throughout the venue. Some shows might
need a lot of FOH (Front Of House) lights and not many on stage. Another show
might need lots of lights on stage and not many at FOH. The large number of
outlets allow flexibility when lighting each show. In smaller installations
where cost is a major factor, providing a dimmer or switch channel for each
outlet in the venue is unlikely to be viable. Instead, each outlet is wired
back to a Redback Patch Bay located next to the dimmer/switches. Therefore,
depending on the show, the lights required can be chosen from the patch bay
and plugged into the dimmers/switches offering a degree of flexibility that
could not be achieved easily in any other way.
The piggy-back plugs also allow the paralleling of circuits. For example, a
lighting bar might be rigged with 4 wash lights that are plugged into separate
outlets. The 4 patch leads for these outlets can be piggy-backed into one
dimmer circuit to control all 4 lights simultaneously, thus saving 3 dimmer
circuits.
In the following simplified example, a 24 circuit Redback patch bay provides
connections to 12 circuits on the stage and 12 circuits at the FOH. A 12
channel GEN VI Switch/Dimmer provides the controlled power. For this example,
4 FOH circuits are patched into Dim/Sw channels and 7 stage circuits are
patched into Dim/Sw channels.
1.4 Frame and Module Sizes
Four frame sizes of Redback Patch Bay are available. Frames are fitted with 12
circuit patch modules allowing for systems up to 36, 72, 144 or 240 circuits.
Frame Size | 36 | 72 | 144 | 240 |
---|---|---|---|---|
Quantity of Patch Modules | 1-3 | 4-6 | 7-12 | 13-20 |
Quantity of Patch Circuits | 12-36 | 48-72 | 84-144 | 156-240 |
A frame size larger than initially required may be used to allow for future
expansion. The required number of 12-circuit patch modules are fitted with the
empty locations filled with blank panels.
Install what you need today then add extra circuits when your requirements
expand.
1.5 Cable Management
The optional cable management clips are available and help in arranging unused
cables to aid in access to the required patch leads.
Test Module
The optional test module has 3 functions. It provides a “Test Circuit” 240
volt hot power outlet for testing circuits, a “Test Load” LED to show the
presence of power and a LED work light outlet.
The test module can be included from the factory or it can be retrofitted to
the patch panel after installation. The module requires a 10A power supply of
nominal 220-240V AC, single phase 5060Hz connected via 3-way terminal block on
the rear.
-
Test Circuit.
The 3-pin test circuit outlet provides a source of 240 volt power (protected by a 10Amp RCBO circuit breaker) that can be used to identity or test any load circuit. Plug any patch bay cable into the test circuit 240 volt outlet to provide power to its connected load and to confirm that the connected lamps are in fact operating. A “Test Current Amps” indicator shows the current drawn by the load including an “Overload” warning LED. This can be used to prevent possible overloading of a dimmer circuit. -
Test Load.
The Test Load 3-pin plug and lead is connected to a “Test Load LED” indictor and an internal test load of 25 Watts. The test lead can be plugged into the output of any dimmer or switch channel and the LED will indicate the presence of power. The LED can also be used to observe correct dimmer operation because its intensity will vary as the dimmer is dimmed up and down. The 25 Watt load is included because some types of dimmers require a minimum load to operate correctly. The load must only be connected for a duration of one minute or less. The test load is protected by an auto-resetting fuse. -
LED work light outlet and switch.
The 3 pin XLR pinouts are:
Pin 1 – Do not use
Pin 2 – 0v
Pin 3 – +12v DC
This wiring is the same for all LSC products and many brands of LED work lights however some brands use a different wiring configuration and might need to be modified.
2.1 Self Test
To test both the “Test Circuit” and the “Test Load”, momentarily plug the Test
Load plug into the Test Circuit outlet and ensure that the Test Circuit
breaker is on. The “Test Load LED” will light, indicating that the Test
Circuit is providing power. Unplug the Test Load plug.
Installation
Note: All electrical work must be carried out by suitably qualified persons.
Typical Installation. 144 Patch Points and 24 Dim/Switch channels
3.1 Step 1
Install the empty Redback mounting frame onto the wall surface or Unistrut
using 6mm or ¼ inch fasteners in all four mounting holes.
The bottom of the chassis should be a minimum of 1270mm above the floor to
allow hanging clearance.
3.2 Step 2.
External wiring can enter the chassis either directly through the wall cavity
or through the end panels by removing the required quantity of cable knockouts
at the top and bottom of the frame.
3.3 Step 3
Starting at the bottom and working up, the patch modules can now be installed
in the frame and load circuits terminated.
Each 12 circuit patch module has an interlocking lip that temporarily holds
the module at an angle, exposing the terminating strip for easy access. Each
tail circuit has an Active (A), Neutral (N) and Earth (E) screw termination.
An empty space above each circuit termination label allows custom patch numbers to be written.
3.4 Step 4
Ensure that each patch module has the earth terminated to the chassis using
the provided spade terminal.
The patch module can now be positioned and screwed into the frame.
Repeat steps 3 and 4 for the remaining patch modules.
Extra spade terminals are provided internally for the termination of the
installation building wiring earth to the Redback patch chassis.
3.5 Step 5
An optional test circuit panel can be installed at the top of the Redback
patch chassis. This panel requires a 240VAC/10 Amp mains source which provides
power to connected test loads. A three terminal screw header allows for Active
(A), Neutral (N) and Earth (E) screw termination. The panel earth wire is
terminated to the chassis using the spade terminal provided.
Specifications
4.1 Mounting Frame
Side aluminium extrusions and powder-coated metal end plates similar in
construction to LSC’s REDBACK wallmount dimmers.
Cable access via open rear entry or knock-out panels in top and bottom end
plates.
Easy-access mounting holes for quick installation.
Blank panels provided for expansion modules.
12-36 | 48-72 | 84-144 | 156-240 |
---|---|---|---|
Expandable from 12 circuits up to 36 circuits | Expandable from 48 circuits up | ||
to 72 circuits | Expandable from 84 circuits up to 144 circuits | Expandable |
from 156 circuits up to 240 circuits
515mm (w) x 120mm (d) x 284mm (h)| 515mm (w) x 120mm (d) x 417mm (h)| 515mm
(w) x 120mm (d) x 684mm (h)| 515mm (w) x 120mm (d) x 1040mm (h)
Weight: 8kg (12 circuits) up to 12kg
(36 circuits)| Weight: 16kg (48 circuits) up to 21kg
(72 circuits)| Weight: 26kg (84 circuits) up to 38kg
(144 circuits)| Weight: 44kg (156 circuits) up to 61kg
(240 circuits)
4.2 Patch Module
12 circuits per module in 1RU high 19″ rackmount.
10A moulded piggy-back plug and 1300mm cable per circuit.
Individual Active-Neutral-Earth 4mm2 pressure-pad terminals for each circuit.
484mm wide x 44mm high folded corrosion-resistant, powder-coated metal
housing.
Supplied rear-printed mylar labels for circuit numbering.
Custom circuit numbering available on request.
Weight: 2kg.
4.3 Test Module
3-pin Australian GPO test outlet with 10A RCBO protection.
Test load of 25W max for a duration of one minute.
Flying test lead with 3-pin plug fitted with inbuilt, auto-resetting fuse.
LED indicator for circuit load output and overload indication.
Requires 10A power supply of nominal 220-240V AC, single phase 50-60Hz
connected via 3-way terminal block.
484mm wide x 44mm high folded corrosion-resistant, powder-coated metal housing
with rear screened polycarbonate front label.
Compliance Statements
The Redback Patch Bay range from LSC Control Systems Pty Ltd meets all required CE (European), RCM (Australian) and UKCA (United Kingdom) standards.
CENELEC (European Committee for Electrotechnical Standardization).
Australian RCM (Regulatory Compliance Mark).
WEEE (Waste Electrical and Electronic Equipment).
The WEEE symbol indicates that the product should not be discarded as unsorted waste but must be sent to separate collection facilities for recovery and recycling.
For more information about how to recycle your LSC product, contact the dealer where you purchased the product or contact LSC via email at info@lsccontrol.com.au
You can also take any old electrical equipment to participating civic amenity sites (often known as ‘household waste recycling centres’) run by local councils. You can locate your closest participating recycling centre using the following links.
- AUSTRALIA http://www.dropzone.org.au.
- NEW ZEALAND http://ewaste.org.nz/welcome/main
- NORTH AMERICA http://1800recycling.com
- UK www.recycle-more.co.uk.
LSC Control Systems ©
+61 3 9702 8000
info@lsccontrol.com.au
www.lsccontrol.com.au
References
- Search. Find. Recycle - RecycleNation
- Search. Find. Recycle - RecycleNation
- LSC
- LSC
- LSC
- Everything you need to know to Recycle More
- Everything you need to know to Recycle More
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>