AirGuard AG-1600 Fog Sanitization Machine User Manual
- June 6, 2024
- AirGuard
Table of Contents
AG-1600 Antibacterial Vaporizer
USER MANUAL
Safety Information
Thank you for choosing Air Guard. Please read the following safety information carefully before operating the machine. This information includes important safeguards about installation, usage, and maintenance. Pay attention to all warning labels and instructions Vin this manual and printed on the machine.
- Keep this device dry.
- Always connect to a grounded circuit to avoid the risk of electrocution.
- Before connecting the machine to power, always check the voltage indicated on the machine matches your local AC voltage. Do not use the machine if the AC power voltage does not match.
- Disconnect the machine from AC power before servicing and when not in use.
- If the supply cord is damaged, contact your local dealer for replacement.
- This product is for indoor use only! Do not expose to rain or moisture. If the fluid is spilled, disconnect AC power and clean with a damp cloth. If the fluid is spilled onto electronic parts, immediately unplug the machine and contact your local dealer for advice.
- No user-serviceable and modifiable parts inside. Never try to repair this product, an unauthorized technician may lead the machine to damage or malfunction.
- For adult use only. Children are being supervised not to play with the machine. Never leave the machine running unattended.
- The machine is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge.
- Installed in a well-ventilated area. Provide at least 50 cm of space around the machine.
- Never add flammable liquid of any kind to the machine.
- Make sure there are no flammable materials close to the machine while operating.
- Only use Air Guard Antibacterial Solution. Other solutions may lead to heater clog and malfunction.
- If the machine fails to work, unplug the machine and stop operation immediately. Contact your local dealer for advice.
- Before transporting the machine, make sure the fluid tank is completely drained.
- Do not drink the Air Guard solution. Store it securely. In case of eye contact, immediately look for medical advice.
Unpacking and Inspection
Immediately upon receiving the antibacterial vaporizer, carefully unpack the carton, check the content to ensure that all parts are present and have been received in good condition. If any parts appear damaged or mishandled from shipping, notify the shipper immediately and retain the packing material for inspection.
What is included:
1 x AG-1600 Antibacterial Vaporizer
1 x Wireless Remote Control
1 x Power Cord
1 x User Manual
Product Dimensions
Product Overview
Setting Up
Step 1: Place the machine on a flat surface and in a suitably large area
with at least 50 cm open space at each side of the machine and 2 meters for
the output direction of the machine.
Step 2: Fill the fluid tank with Air Guard fluid.
Step 3: Connect the machine to the suitably rated power supply. To
determine the power requirement for the machine refer to the label on the back
of the machine.
Always connect the machine to a protected circuit and ensure it is properly grounded to avoid the risk of electrocution.
Step 4: Turn on the power switch. Once powering up the machine, it takes approximately 6 minutes to complete the warming-up process to make the heater reach an operating temperature to work.
Operation Instructions
The date format is YYYY/MM/DD. The time format is HH:MM: SS.
The AG-1600 has a built-in clock and calendar. It is important to have an
accurate clock setting to ensure the proper operation of the schedule
application. To adjust the date and/or time displayed, on the main menu page
(Date/Time page), press and hold the MENU button for 3 seconds to enter the
date/time setting mode. Use ▲ (UP/TIMER) and ▼ (DOWN/VOLUME) buttons to adjust
the highlighted value. Once all changes have been made, press the STOP button
to confirm and save the selected setting.
Manual Mode (Volume Button ):
The AG-1600 has a quick access button to manually operate the unit in either “Normal” or “High” mode. After the unit has reached operating temperature simply press the▼ (DOWN /VOLUME) button and the unit will immediately begin to fog in the preselected mode and tap the STOP button to stop manual output. To change “ Volume” o utp ut mode, tap the MENU button once while on the main menu page (Date/Time page), use the ▲ (UP/TIMER) and ▼ (DOWN/VOLUME) buttons to scroll to “Output Volume,” tap the STOP button once to toggle between “Normal” and “High” using the ▲ (UP/TIMER) and ▼ (DOWN/VOLUME) buttons. Once you make your selection tap the STOP button once again to confirm and save the desired setting.
Timer Mode:
The AG-1600 includes an advanced built-in electronic timer control that allows
the unit to fog for a predetermined amount of time. To activate the timer
simply press the ▲ (UP/TIMER) while on the main menu page (Date/Time page). To
adjust the settings of the built-in timer tap the MENU button twice from the
main menu page (Date/Time page) until “Timer” is displayed in the menu, then
press the STO button to access the different timer settings. There are three
different settings that can be configured;
Waiting Time , Fogging Time, and Cycle Duration. Use the ▲ (UP/TIMER) and
▼ (DOWN/VOLUME) buttons to toggle between the different settings.
*Waiting Time* – is the amount of time in between blast and can be set
between 00:10 (10 seconds)and 60:00 (60 minutes) by using ▲ (UP/TIMER) and ▼
(DOWN/VOLUME) buttons. Once a setting has been made press the STOP button once
to confirm and save the setting.
Fogging Time – is the amount of time the unit will emit fog and can be
set between 00:10 (10 seconds) and 60:00 (60 minutes) by using ▲ (UP/TIMER)
and ▼ (DOWN/VOLUME) buttons. Once the setting has been made press the STOP
once button to confirm and save the setting.
Cycle Duration – is the number of times the machine will repeat the
above two settings before stopping and can be set between 1 and 20 times or
Continuous by using ▲ (UP/TIMER) and ▼ (DOWN/VOLUME) buttons. Once a setting
has been made press the STOP button once to confirm
and save the setting.
Note: If cycle duration is set to “Continuous” the AG-1600 will continue
to run the timer settings until the timer is switched off manually by pressing
the STOP button.
Once all settings are made press the STOP button again to exit the settings
menu and return to the main menu page (Date/Time page), press ▲ the (UP/TIMER)
button to trigger Timer mode, and press the STOP button to stop Timer mode.
Together the three different settings provide for an extremely flexible
fogging cycle, for example: If you wish the AG-1600 to fog for 5 minutes every
30 minutes, three times, set the Waiting Time to 30:00, the Fogging Time to
05:00, and the Cycle Duration to 3.
NOTE: At the end of the last cycle the AG-1600 will automatically go into
standby mode in three minutes, shutting down the heater and display to
conserve power.
Schedule Mode :
The AG-1600 comes with a built-in clock and calendar that allows the unit to
be triggered automatically at any time. This feature is especially useful when
wanting to sanitize a room or sphacelate at night or any other time when a
room is scheduled to be empty. There are two selectable schedules available:
Schedule 1 and Schedule 2. Both schedules have the same function and both can
be run simultaneously.
To access and activate the schedule 1 function tap the MENU button 3 times
from the main menu page (Date/Time page) until “Schedule 1” appears in the
menu, you can then use the ▲ (UP/TIMER) and ▼ (DOWN/VOLUME) buttons to toggle
between ON (activate) and OFF (deactivate).
To adjust the settings for schedule 1, press the STOP button while on
“Schedule 1” in the main menu page (Date/Time page) to access the different
schedule settings. There are three different settings that can be configured;
Day, Start Time, and Stop Time. Use the ▲ (UP/TIMER) and ▼ (DOWN/VOLUME)
buttons to toggle between the different settings.
Day set : – Is the day or days the schedule 1 will activate and is
represented by the following; S, M, T, W, T, F, S . an n d re present Sunday
through Saturday respectively. Use the ▲ (UP/TIMER) and ▼ (DOWN/VOLUME)
buttons to select the days you would like the AG-1600 to run. For example; If
you would like the AG-1600 to run on Mondays and Wednesdays, adjust the days
setting to read , M, , W, , , _. Only the “M” (Monday) and “W” (Wednesday)
should be displayed in the menu.
Once you have finished your selection press the STOP button once to confirm
and save the settings.
Start Time – is the time of day the AG-1600 will begin to fog. This
setting is displayed in 24 hour time and can be adjusted between 00:00 and
23:59 by using the ▲ (UP/TIMER) and ▼ (DOWN/VOLUME) buttons. Once you have
finished your selection press the STOP button once to confirm and save the
settings.
Stop Time – is the time of day the AG-1600 will stop the fogging
process. This setting is displayed in 24 hour time and can be adjusted between
00:00 and 23:59 by using the ▲ (UP/TIMER) and ▼ (DOWN/VOLUME) buttons. Once
you have finished your selection press the STOP button once to confirm and
save the settings.
Once all settings are made press the STOP button again to exit the settings
menu and return to the “Schedule 1” menu page and use the ▲ (UP/TIMER) and ▼
OWN/VOLUME) buttons to either activate or deactivate schedule 1.
Example of the schedule function:** If you wish the AG-1500 to start to fog
at 13:00 and stop fogging at 13:15 in the afternoon every Monday, the settings
should be set as follows: Day: , M, , , , , . , Start Time: 13:00, Stop
Time: 13:15,
To activate and change the setting for schedule two (2), tap the MENU button
four (4) times from the main menu page (Date/Time page) until “Schedule 2”
appears in the menu and follow the same instructions listed above for Schedule
- NOTE: At the end of a scheduled cycle, the AG-1600 will automatically go
into standby mode in three minutes, shutting down the heater and display to
conserve power.
Wireless Remote setting:
The AG-1600 wireless remote function can be turned off if necessary. On extremely rare occasions the AG-1600 may encounter wireless interference that will require the built-in wireless function to be switched off. To change the wireless setting, tap the MENU button five (5) times while on the main menu page (Date/Time page). After the fifth tap of the menu button, the menu will switch to the Remote Settings page. Toggle between “ON” (active) and “OFF” (inactive) using the ▲ (UP/TIMER) and ▼ DOWN/VOLUME) buttons. Once you make your selection tap the STOP button once to confirm and save the desired setting.
Wireless Remote Control Operation
The wireless remote control system consists of a transmitter equipped with two buttons to activate, deactivate and an onboard receiver attached to the rear panel of AG-1600.
W-1 Wireless Transmitter
Press button ○A to emit fog and press button ○B to stop.
Wireless Receiver
The maximum working distance of a wireless remote is 50 meters. The distance
varies, depending on the transmitter’s battery level, and blockage and
interference of radio signal.
Pair and Delete transmitters
Step 1: Power off AG-1600 Antibacterial Vaporizer
Step 2: Press and hold ▼ (DOWN) button
Step 3: Turn the power on and release ▼ the (DOWN) button when the LCD display
blinks
Step 4: Follow the instructions shown in the LCD display to pair or delete
transmitters
Notes:
One machine can be controlled by up to 10 transmitters while one transmitter
can be paired with an unlimited number of machines.
Transmitter battery replacement
If the wireless remote’s working distance is reduced, it is possible the
battery level is low. Undo the screws on the back of the transmitter case and
remove the cover. Replace with the same type and specification of battery
which is 27A 12V.
Fluid
Use Air Guard Antibacterial Solution for AG-1600. The machine is tested and calibrated with these authorized fluids to achieve the best performance. Warranty will be void if any other type of liquid is used. Improper use of liquid may lead to machine failure and danger.
Service and Maintenance
- Do not allow the machine and fluid to become contaminated.
- Regularly fill distilled water into the fluid tank and run the machine to clean the system. After cleaning, refill Air Guard fluids into the fluid tank and make sure the machine can produce fog properly.
- It is recommended to run the machine on a monthly basis in order to achieve the best performance and output condition.
- Excessive dust, liquid, and dirt built up will degrade performance and cause overheating.
Breaker Reset
Disconnect AC power before resetting the breaker. Only replace the fuse
with the same type and rating.
Step 1: Disconnect AC power.
Step 2: Flip breaker to ON position.
Step 3: Turn on the machine for testing.
Breaker
100-120V = 15A 250V
220-240V = 8A 250V
Technical Specifications
– Input voltage| US model : AC 100-120V, 50 / 60Hz 12A
EU model : AC 220-240V, 50 / 60Hz 6A
---|---
– Rated power| 1450W
– Warm-up time| 6 minutes (approx.)
– Maximum Fluid consumption| 40 ml/min
– Fluid tank capacity| 2.4L (0.63gal)
– Compatible fluid| Air Guard Antibacterial Solution
– Ambient temp. range| 0 °C – 40 °C (32 °F-104 °F)
– Output height| 2 meters height
– Control| Built-in Calendar Manual
Wireless Remote Timer
– Connection| IEC (Power)
– Dimension| L344 W193 H381 mm
(L13.54 W7.60 H15 inch)
– Weight| 10.7 kg (23.6 lbs)
M22 Moisture Co., Ltd.
Tel : +886 3 2227470 Fax : +886 3 2227469
www.airguard.com.twe-mail
sales@airguard.com.tw
C08AG1601