aoi UH-OM1 II Underwater Housing User Guide
- September 17, 2024
- AOI
Table of Contents
UH-OM1 II Underwater Housing
Specifications
- Model: AOI UH-OM1 II
- Compatibility: OM SYSTEM OM-1 & OM-1 Mark II cameras
- Material: High-quality durable plastic
- Accessories: Various accessories included, see full list in the manual
Product Usage Instructions
Items Included in the Package
- AOI UH-OM1 II Underwater Housing
- Body Cap / Storage Box for PEN Mount Housing (AOI BC-02)
- USB Type-C Charging Cable (AOI USBC-02)
Names of the Parts
Installing Camera in the Housing
- Ensure camera and lens compatibility with the housing, lens port, and lens gear.
- Press down Port Release Button and rotate the Body Cap counterclockwise to remove it from the Housing Body.
- Press down the Latch on the side of the Storage Box and rotate the Top Cap counterclockwise to open it.
Frequently Asked Questions (FAQ):
Q: What should I do if water leaks into the housing?
A: Immediately remove the camera and dry the housing thoroughly. Check O-rings
and seals for damage.
AOI UH-OM1 II UNDERWATER HOUSING
GENERAL GUIDE
Thank you for your purchase of an AOI product. Please read this general guide prior to using the housing. It will provide an overview of how this product can be used for optimal performance. For additional information, please consult your local dealer or write to info@aoi-uw.com
- Press down Port Release Button and rotate the Body Cap counterclockwise by about 90 degree. Then pull out the Body Cap from the Housing Body (fig. i & ii).
- Holding the base of the Storage Box, press down the Latch on the side and rotate the Top Cap about 30 degree counterclockwise,then you can lift up the Top Cap (fig. iii & iv).
- unlock the Security Lock on the Cam Lock (fig. v). Press down the Cam Lock Release and rotate the Cam Lock clockwise at the same time (fig. vi). Rotate the Cam Lock until the Rear Cover is fully separated from the Cam Lock (fig. vi).
Items Included in the package
- AOI UH-OM1
- Housing Body
- Body Cap / Storage Box for
- PEN Mount Housing (AOI BC-02)
- USB Type-C Charging Cable (AOI USBC-02)
- LCD Monitor Hood (AOI LCDH-01)
- Spare O-Ring for Vacuum Valve
- Protection Cap x 1pc. (AOI SRV-01)
- Vacuum Pump (AOI VP-03)
- Spare Main Seal
- O-Ring x 1pc. (AOI SOR-04)
- Spare Secondary Seal Ring x 1pc. (AOI SSR-04)
- Silicone Grease (AOI SIGR-5) 1 Silica Gel (AOI SIGE-3) x 1pc.
- Lanyard (AOI LYD-01) 2 Micro-Fiber Cleaning Cloth (AOI MC-01) AOl Logo Sticker
- General Guide 1 O-ring Remover ( AOI ORR-02 )
- Hot Shoe Connector (AOI HSC-02)
Names of the Parts
- Body Cap (Storage Box)
- Button
- Port Release Button
- LOCK Button
- Lanyard Eyelet
- Vacuum Valve
- Cam Lock Release
- Fiber Optic Cable Ports
- Cam Lock
- Cold Shoe
- Security Lock
- Button
- Front Dial 1 Camera ON/OFF Lever
- Shutter Release Lever
- AF Button
- AF-ON Button Lever
- Lens Gear
- Control Knob Video
- Button
- Lens Release
- Button < Main Seal O-ring
- Camera Positioning Bumpers
- Camera Front Stoppers
- Camera Top Stopper
- Secondary Seal Ring
- Multi-control
- Device ON/OFF Switch
- Multi-control Signal Indicator
- USB Type-C Port
- Camera ON/OFF Actuation Lever
- Bridge Gear for Lens Gear
- MENU Button
- LCD Monitor Hood Rails
- LCD Hood String Eyelet
- LCD Monitor Window
- Button
- Button
-
- Button
- Button
- INFO Button
- Button
- Button
- A Button
- FN Lever € AF-ON Lever
- ISO Button
- Rear Dial
- AEL Lever
- Mode Dial
Installing camera in the housing
- Before use, ensure the camera (OM SYSTEM OM-1 & OM-1 Mark II ) and camera lens are compatible with the housing, lens port and lens gear.
For more information about AOl UH-OM1 Il Expansion Pathway and PEN Mount Lens Ports System, please visit www.aoi-uw.com or consult with your local dealer. –
-
Press down Port Release Button and rotate the Body Cap counterclockwise by about 90 degree. Then pull out the Body Cap from the Housing Body (fig. i & ii).
-
Holding the base of the Storage Box, press down the Latch on the side and rotate the Top Cap about 30 degree counterclockwise, then you can lift up the Top Cap (fig. iii & iv).
-
Unlock the Security Lock on the Cam Lock (fig. v). Press down the Cam Lock Release and rotate the Cam Lock clockwise at the same time (fig. vi). Rotate the Cam Lock until the Rear Cover is fully separated from the Cam Lock (fig. vi).
-
Turn on the Multi-control Device. If its battery power is low, the Signal Indicator will show Blue Quick Blinking. You should connect the supplied USB Type-C Charging cable to the USB Type-C Port on the Multi-control Device and the other end to a USB Charger DC 5V, minimum 0.5A (not supplied) (fig. viii). It will take approx. 1.5 hours to fully charge the battery. Table 1 below shows the status of the battery charging and the corresponding colors of the Signal Indicator
-
Battery operation time per charge is approx. 4 days (based on 3 dives/day and approx. 1 hour/dive).
-
Turn off the camera before installing it into the housing. Remove all camera accessones such as Lanyard, Lens Filter or Hand Grip, etc. h. Pull up the Camera ON/OFF Actuation Lever before you install the camera into the housing (fig. ixO).
-
Return the Camera Monitor back to its original position with the display facing outside and ensure the Camera Strap Eyelets are folded down against the camera body (fig. x). Load the camera into the housing gently and do not hold the camera by the Monitor Screen while inserting
-
After the camera is properly loaded, push down the Camera ON/OFF Actuation Lever and engage with the camera ON/OFF Lever(fig. ix®).
-
If using the Optical Flash Trigger for the external Slave Strobes, the Hot Shoe Port on the Must control eric eig en the camera’s Hot Shoe and the USB Type-C
-
Turn on the power of the Multi-control Device (fig. xili).
-
To check if the Hot Shoe Connector is connected properly, go to the RC menu on the camera. If the connection is good, the RC Menu text will show solid white. Otherwise, all text will show gray and can’t be activated.
-
Before closing the housing, ensure the camera is positioned properly against the Camera Positioning Bumpers in the front of the housing. Check that the Main Seal O-ring and Secondary Seal Ring are clean, intact, and properly positioned. There are no obstacles such as the lanyard or strips preventing the secure closure of the housing. o. Close the Housing Rear Cover by rotating the Cam Lock counterclockwise until a “Click” sound is heard (fig. xiv). If you encounter resistance, clear obstacles before continuing.
-
Switch the Security Lock on the Cam Lock to the “LOCK” position in order to prevent Cam Lock from opening accidentally (fig. xv).
-
Once the camera is installed and the housing is closed, turn on the power of the camera and make sure all housing controls and lens gear function properly. Check that the Optical Flash Trigger is functioning with the external slave strobe(s).
Installing Lens Port in the housing
- To install the Port Lens, align the Alignment Marks on the Lens Port and the Housing Body and then push the Lens Port completely down into the Housing Body(fig. xvi). Rotate the Lens Port clockwise until a “Click” sound is heard. When the Port Release Button is no longer depressed, the Lens Port is properly installed and locked (fig. xvii).
Pre-checking before Diving
- Pre-Check Fn Lever a. Remember to set the Fn Lever position on the Housing before going into water.
- Before closing the Housing, ensure the Fn Lever on the Housing and AEL Button on the Camera are at the same position. For example, if the Fn Lever on the Housing is set to position “1”, also set the AEL Button on the Camera to position “1”. Otherwise, all the buttons will not work during use.
- In case the Fn Lever and AEL Button were not set prior to closing the housing, it is still possible to set the Fn Lever and AEL Button while underwater or when the Housing is closed and secure. Push the Fn Lever to set it to the same position of the AEL Button when the Housing is.
Perform Vacuum Analyzation
-
Turn on the Vacuum Analyzation and Wet Detection System (VWS) by power on the Multi-control Device, the Signal Indicator will show Blue Blinking or Blue Quick Blinking (once/sec). If it is not operated for more than 10 minutes, the Vacuum Analysis and Wet Detection System will go into standby mode and the Signal Indicator will show Blue Blinking (once/5 sec). Close the Rear Cover according to the steps described in Installing camera into the housing
-
Take off the Protection Cap from the Vacuum Valve and connect the Vacuum Pump onto the red colored Vacuum Valve Tip. Pull and Release the Vacuum Pump handle gently and repeatedly for Vacuum Pumping. During the Vacuum Pumping process, check carefully for changes in color on the Signal Indicator (fig. xviii ~ xxi).
-
Color Codes Indication:
- Yellow Quick Blinking Internal pressure has started to drop. Continue to pump.
- Yellow Slow Blinking Internal vacuum level is close to the desired value. Slow down pumping.
- Yellow Still | Internal vacuum level has been reached. Stop pumping and the Vacuum Analyzation Process will start automatically.
- Yellow and Red Blinking alternately Internal vacuum level is above the desired value. Stop pumping and carefully release air by gently twisting the red colored Vacuum Release Tip counterclockwise slightly until the Signal Indicator shows Yellow Still (fig. xxii). If too much air is released from the housing, the Signal Indicator will change back to Yellow Blinking again. Resume vacuum pumping until Signal Indicator shows Yellow Still.
- The Vacuum Analyzation Process will start automatically once the Signal Indicator shows Yellow Still. Disconnect the Vacuum Pump from the Vacuum Valve carefully and then put back Protection Cap to the Vacuum Valve (fig. xxiii). Do not move or shake the housing or put the housing under the sun when the analyzation process has started.
- The Vacuum Analyzation Process takes approx. 3 minutes. Once the process is completed, the Signal Indicator will show different color depending on the result:
- Green Blinking – Vacuum Analyzation passed and Housing is ready to go into the water.
- Red Blinking – Vacuum Analyzation failed and inspection for the leakage is required. Please re-check all the seals on the housing. Power off the Multi-control Device to reset the system and attempt the Vacuum Analyzation process again.
Perform Water Leakage
Test Once Vacuum Analyzation is completed successfully and Vacuum Valve
Protection Cap is secured, review the housing further by checking for water
leakage. Submerge it in a shallow water tank. While submerged, activate all
the control buttons, control switches, and control knobs in order to have a
dynamic test to prove all the sealed moving parts are water sealed property.
If there is no water droplet observed inside the housing after Underwater
Dynamic Test, it means the housing is fully watertight. If water leaks into
the housing, the water droplets will be detected by the Wet Sensor Strip
located in the lowest part of the housing. Signal Indicator will show Red
Still and 5 Sec audible alarm “BEEP. BEEP-BEEP” will be heard (fig. xxiv).
Summary of Signal Indicator Color Codes Indication
Signal Indicator | Indication | Next Action |
---|---|---|
Blue Blinking | Ready for Vacuum analyzation | Vacuum Pumping |
Yellow Blinking | Vacuum below desired level | Continue pumping |
Yellow and Red
Blinking alternately
| Vacuum above desired level| Twist the red colored Vacuum Release
Tip counterclockwise
Yellow Still| Vacuum analyzation in progress| Wait approx. 3 minutes for vacuum
analyzation
Green Blinking| Vacuum analyzation test has passed| Ready to go into the water
Red Blinking| Vacuum analysis test has failed| Inspect the housing for
any potential air leakage sources
Red Still
+ 5 Sec Audible Alarm
| Wet Sensor Strip detects
water droplet or moisture
| Inspect the housing for
any potential water leakage sources
Red-Green-Blue Blinking| System Error| Contact AOI Service Center
Using the Housing and Camera after testing passed
- Please ensure that the Vacuum Valve Cap is in place and completely closed.
- When using the housing, make sure that it is properly secured to you and accessories are properly secured to the housing.
- Do not exceed the housing maximum depth rating of 45 Meters (148 ft.) d. If the wet detection alarm is triggered during use, it means water has entered into the housing. If that happens, try to position the housing lens port facing down and exit the water safely in accordance with diving procedure and regulation. Upon returning to land, remove the camera from the housing. If only a few droplets of seawater entered the housing, thoroughly wipe off the seawater droplets with a moist towel and dry the inside of the housing thoroughly with tissue paper. e. If seawater leaked into the housing and the Multi-control Device is flooded, take out the camera, rinse the housing cavity thoroughly with running fresh water for a few minutes. Then, dry the housing cavity completely and bring it to your local dealer for servicing immediately.
Auto Sleeping Mode
When the Multi-control Device is connected to the camera with the Hot Shoe
Connector, it will follow to the status of the camera. When the camera is in
Sleep Mode, the Multi-control Device will be in Sleep Mode too. When the
camera is operational, the Multi-control Device will be operational too.
Connecting the Fiber Optic Cable
-
The housing is built-in with an Optical Flash Trigger in the Multi-control Device. This feature prolongs the camera battery life by not using the built-in camera flash to trigger the external underwater strobe. The housing is equipped with two Fiber Optic Cable Ports and they are compatible with AOl Fiber Optic Cable with SS cable plug or other fiber optic cable brands using the standard Sea & Sea plug
-
Insert one end of the fiber optic cable into the Fiber Optic Cable Port of the housing (fig. xxv) and then insert the other end into the fiber optic cable port on the external strobe.
-
The flash trigger signals (electrical signals) will be transterred from the camera Hot Shoe to the Multi-control Device through the Hot Shoe Connector (included in the package). The Optical Flash Trigger in the Multi-control Device will convert the electrical tlash triggering signals into optical signals and then will deliver them to the Fiber Optic Cable. The Fiber Optic Cable (not included in package) picks up the optical signais and delivers them to the external strode.
IMPORTANT
- For getting the best result of Flash Triggering, Multi-core Fiber Optic Cable is recommended 1o be used.
- Rinse the Fiber Optical Cable Ports with running fresh water after every use, then let it dry naturally. Do not dry inside of the ports with any tool, this may result in scratches and reduce the capacity of the optical signal transter.
Care and Maintenance
-
Rinse the housing exterior thoroughly with running fresh water after every use. Depress buttons and rotate knobs/dials repeatedly in fresh water to eliminate trapped salt water or debris. Dry the housing and Lens Port with a soft, clean cloth to avoid water spotting and damage.
-
To clean the Lens Port Glass, use a mild soap solution or lens cleaner. Do not rinse the inside of port glass. Do not use alcohol or window cleaner on the Lens Port Glass.
-
In order to better inspect, position, clean or lubricate the Housing Main Seal O-ring or Lens Port O-rings, carefully remove the required O-ring by using the provided AOl O-Ring Remover.
-
Clean the Main Seal O-ring and its O-ring groove by using a microfiber cloth only. Use AOl O-Ring Remover to clean the O-Ring groove. Do not use cleaning substances other than fresh water. Remove sand, dirt, hair or fibers that can prevent a proper housing seal.
-
To lubricate O-rings, apply a small amount of silicone grease (AOl SIGR-5) on your fingertips, gently pull the O-ring through the fingertips. This will lightly coat the entire O-ring with silicone grease. Only use the AOl Silicone Grease supplied or those approved by AOl. Using other brands of silicone grease may damage the O-ring. Do not over stretch the O-ring
Note: DO NOT APPLY Silicon Grease to the Secondary Seal Ring. f. Do not leave the camera and housing in direct sunlight for prolonged periods. Heat may damage the camera and housing. -
Dry well and remove the camera prior to travel and storage. h. Store the housing in a cool and dry place.
IMPORTANT
- Wipe the housing dry and keep water away prior to opening the housing. Do not allow water to be in contact with the interior of the housing. This will cause irreparable damage to the Vacuum Analyzation and Wet Detection System (VWS) | and other electronic/electrical components! b.
- If you don’t use the housing, please remember to fully charge the battery in the Multi-control Device for every half year.
Specifications
Model Number | AOI UH-OM1 II |
---|---|
Description | Underwater Housing for OM SYSTEM OM-1 and OM-1 Mark II Cameras |
Housing Color | Translucent Grey |
Compatible Camera Models | **** OM SYSTEM OM-1 & OM-1 Mark II Cameras |
Main Material | Housing Body: Polycarbonate |
Depth Rating | 45 Meters |
Lens Port System | AOI / Olympus PEN Ports System |
Built-in LED Flash Trigger | Compatible with |
- Manual Flash Trigger (with and without Pre-flashes Functions)
- Olympus RC Mode
(TTL AUTO, MANUAL, FP TTL AUTO, FP MANUAL)
Water Leakage Protection| Built-in Vacuum Analyzation and Wet Detection
System (VWS)
Battery Power| Built-in Rechargeable Lithium Polymer Battery (3.7V 220mAH)
Battery Charging| By USB Charger DC5V, 0.5A (not included) Approx. 1.5 Hours
for a full charge
Battery Operation Time|
Approx. 4 Days (Based on 3 Dives/Day and 1 Hour/Dive)
Dimensions| 195.9mm (W) x 129.7mm (H) x 149.7mm (D)
**** Weight| On Land : Approx.1079 grams
(Only included the Housing Body and Body Cap)
Specifications and Appearances are subject to change without prior notice.
AOI is a registered trademark of AOI Ltd. All rights reserved. www.aoi-
uw.com
All other trademarks are the property of their respective owners.
Made in China