AOI Olympus OM-D E-M5 III Underwater Housing UH-EM5III User Guide
- June 6, 2024
- AOI
Table of Contents
AOI UH-EM5III UNDERWATER HOUSING
GENERAL GUIDE
Thank you for your purchase of an AOI product. Please read this general guide prior to using the housing. It will provide an overview of how this product can be used for optimal performance. For additional information, please consult your local dealer or write to info@aoi-uw.com
Items Included in the package
1. AOI UH-EM5III Housing Body
2. Body Cap / Storage Box for OM-D
3. Mount Housing
4. USB Type-C Charging Cable
5. Monitor Hood
6. Spare O-Ring for Vacuum Valve Protection Cap x1pc
7. Vacuum Pump (AOI VP-01)
8. Extended Shutter Release Lever
9. Spare Main Seal O-Ring x1pc.
10. Spare Secondary Seal Ring x1pc| 11. Silicone Grease (AOI SIGR-5)
12. Silica Gel (AOI SIGE-3) x3pcs
13 . Lanyard
14. AOI Lens Cleaning Micro Fiber Cloth
15. AOI Logo Sticker
16. Fiber Optic Cable Port Plug x2pcs
AOI O-Ring Remover
/ White Balance Card (AOI ORR-01)
17.AOI UH-EM5III General Guide
---|---
Names of the Parts
1. Body Cap (Storage Box)
2. Port Locking Ring
3. Lanyard Eyelet
4. Cam Lock Release
5. Cam Lock
6. Security Lock
7. Front Dial
8. Shutter Release Lever
9. AEL/AFL Button Lever
10. Button
11. Video Button
12. Mode Dial| 13. Vacuum Valve
14. Fiber Optic Cable Ports
15. Cold Shoe Mount
16. Camera ON/OFF Lever
17. Button
18. Button
19. Gear Control Knob
20. Lever
21. Security Lock for Port Locking Ring
22. Wet Detection Strip
23. USB Type-C Charging Port| 24. Power ON/OFF Switch for
25. Vacuum Analysation and Wet Detection System (VWS)
25. Main Seal O-ring
26. Secondary Seal Ring
27. Camera Front Stoppers
28. amera Positioning Bumpers
29. Bridge Gear for Lens Gear
30. Camera ON/OFF Actuation Lever
31. Camera Top Stoppers
32. LED Flash Trigger Ports
---|---|---
33. Mode Dial
34. Rear Dial
35. **ISO**
Button
36**. AEL/ AFL/**
Lever
37. **menu**
button
38. **INFO**
Button
39. Arrow
40. Arrow
41. **OK**
Button
42. Button| 43. Arrow
44. Button
45. Arrow
46. 1/4”-20 (x3) Tripod Sockets
47. LCD Monitor Window
48. LCD Hood String Eyelet
49. LCD Monitor Hood Rail
50. Vacuum Analyzation & Wet Detection System Status Indicator
51. Spare M16 port
---|---
Installing a camera in the housing
a. Before use, ensure the camera (Olympus OM-D E-M5 Mark III) and camera lens are compatible with the housing, lens port and lens gear.
b. Slide down the Security Lock for the Port Locking Ring and rotate the Port
Locking Ring counter-clockwise (fig.i).
Align the Port Locking Ring (two) cut-outs with the Body Cap’s cut-outs,
remove by lifting Body Cap straight up (fig.ii).
c. Unlock the Security Lock on the Cam Lock (fig.iii). Press down the Cam Lock
Release and rotate the Cam Lock clockwise at the same time (fig.iv). Rotate
the Cam Lock until
the Rear Cover is fully separated from the Cam Lock.
d. Turn on
the Vacuum Analysation & Wet Detection System (VWS). If its battery power is
low, the Signal Indicator will blink rapidly (4 times/sec), connect the
supplied USB
Type-C Charging cable to the USB Type-C Port in the inner side of the Rear
Cover and the other end to a USB Charger DC 5V, minimum 0.5A (not supplied).
It will take
approx. 1.5 hours to fully charge the battery. Table 1 below shows the status
of battery charging and the corresponding light of the Signal Indicator.
Battery operation time per charge is approx. 100 hours.
Table 1
Signal Indicator | Indication | Next Action |
---|---|---|
Fast Blinking BLUE light (4 times/sec) | Charge is required | Connect it to a |
USB charger for charging
Fast Blinking GREEN light| Charging in progress| Continue charging
Still GREEN light| Charging is completed| Remove from a USB charger and stop
charging
f. Turn off the camera before installing it into the housing. Remove all
camera accessories such as Layard, Lens Filter or Hand Grip., etc.
g. Pull up the Camera ON/OFF Actuation Lever up before you install the camera
into the housing (fig. vii-a).
h. Return the Camera Monitor back to its original position with the display
facing outside and make sure the Camera Strap Eyelets are folded down against
the camera body
(fig. vii-b). Load the camera into the housing gently and do not hold the
camera by the Monitor Screen while inserting.
i. After the camera is properly loaded, push down the Camera ON/OFF Actuation
Lever and engage with the camera ON/OFF Lever
j.Turn on the power of the Vacuum Analysation and Wet Detection System (VWS) (fig. viii).
k.Before closing the housing, ensure the camera is positioned properly against
the Camera Positioning Bumpers in the front of the housing. Check that the
Main Seal O-ring and Secondary Seal Ring are clean, intact, and properly
positioned. There are no obstacles such as the lanyard or strips preventing
the secure closure of the housing.
i. Close the Housing Rear Cover by rotating the Cam Lock counter-clockwise
until a “Click” sound is heard (fig.ix). If you encounter resistance, clear
obstacles before continuing.
m. Switch the Security Lock on the Cam Lock to the “LOCK” position in order to
prevent Cam Lock from opening accidentally (fig.x).
n. Once the camera is
installed and the housing is closed, turn on the power of the camera and make
sure all housing controls and lens gear function properly. If you prepare to
use an external flashlight, check that the Olympus Flash FL-LM3 or AOI LED
Optical Strobe Trigger STR-04 (optional accessory) is functioning with the
external slave
strobe(s).
Installing Lens Port in the housing
a. Remove Body Cap.
b. Installing an OM-D Mount Port in the housing body.
c. Installing PEN Mount Port with the AOI AD-LP-01 (Adapter for PEN Port to OM-D Port) in the housing body.
d. Installing OM-D Mount Port with AOI ER-OD_OD-22 ( Extension Ring 22mm OM-D Port to OM-D Mount Housing) in the housing.\ For more information about AOI UH-EM5III Expansion Pathway and OM-D Mount Lens Ports System, please download the OM-D PORTS CHART from www.aoi-uw.com
Pre-checking before Diving
1. Perform Vacuum Analyzation
a. Power on the Vacuum Analysation and Wet Detection System (VWS), if the
Signal An indicator shows Blinking BLUE (1 time/sec), which means the Vacuum
Analysis and
The wet Detection Sensor is on standby mode. Close the Rear Cover according to
the steps described in “Installing camera into the housing”.
b. Take off the Protection Cap from the Vacuum Valve and connect the Vacuum
Pump to the Vacuum Valve Tip. Pull and Release the Vacuum Pump handle gently
and
repeatedly for Vacuum Pumping. During the Vacuum Pumping process, check
carefully for changes in colour on the Signal Indicator.
1. Perform Vacuum Analyzation
c. Colour Codes Indication:
Fast Blinking YELLOW
Internal pressure has started to drop. Continue to pump.
Slow Blinking YELLOW
The internal vacuum level is close to the desired value. Slow down pumping.
Still YELLOW
The internal vacuum level has been reached. Stop pumping and the Vacuum
Analyzation Process will start automatically.
Blinking alternate YELLOW & RED
The internal vacuum level is above the desired value. Stop pumping and
carefully release air by gently twisting the Vacuum Release Tip counter-
clockwise slightly
until the Signal Indicator turns to Still YELLOW. If too much air is released
from the housing, the Signal Indicator will change back to Blinking YELLOW
again.
Resume vacuum pumping until Signal Indicator turns to Still YELLOW.
d. The Vacuum Analysation Process will start automatically once the Signal
Indicator turns Still YELLOW. Disconnect the Vacuum Pump from the Vacuum Valve
carefully and then put back Protection Cap to the Vacuum Valve. Do not move or
shake the housing or put the housing under the sun when the analysis process
has started.
e. The Vacuum Analyzation Process takes approx.4 minutes. Once the process is
completed, the Signal Indicator will turn either RED or GREEN, depending on
the result:
Blinking GREEN – Vacuum Analyzation passed and Housing is ready to go into the
water.
Blinking RED – Vacuum Analyzation failed and inspection for leak is required.
f. In case of a significant air leakage detected anytime during/after the
Vacuum Analyzation Process, the Signal Indicator will turn Blinking RED.
g. Below (Table 2) is the summary of Signal Indicator Colour Codes Indication.
Table 2
Signal Indicator | Indication | Next Action |
---|---|---|
Slow Blinking BLUE (1 time/sec) | Ready for Vacuum analyzation | Vacuum Pumping |
Blinking YELLOW | Vacuum below the desired level | Continue pumping |
Blinking Altern
YELLOW – RED| Vacuum above the desired level| Twist the Vacuum Release Tip
counter-clockwise
Still YELLOW| Vacuum analysis in progress| Wait for 4 minutes for vacuum
analyzation
Slow Blinking GREEN| The vacuum analyzation test has Passed| Ready for going
into water
Blinking RED| Vacuum analysis test has Failed| Inspect the housing for any
potential air leakage sources
Steady RED with audible alarm| Wet Sensor Strip detects water droplets or
moisture| Inspect the housing for any potential water leakage sources
2. Perform Water Leakage Test
Once Vacuum Analysation is completed successfully and Vacuum Valve Protection
Cap is secured, review the housing further by checking for water leakage.
Submerge it in a shallow tub of water or rinse tank. While submerged, activate
all the control buttons, control switches, and control knobs in order to have
a dynamic test to prove all the sealed moving parts are water sealed properly.
If there is no water droplet observed inside the housing after Underwater
Dynamic Test, it means the housing is fully watertight. If water leaks into
the housing, the water droplets will be detected by the Wet Sensor Strip
located in the lowest part of the housing. Signal Indicator will turn Still
RED and audible alarm “BEEP-BEEP-BEEP” will be heard.
Using the Housing and Camera after testing passed
a. Please ensure that the Vacuum Valve Cap is in place and completely closed.
b. When using the housing, make sure that it is properly secured to you and
accessories are properly secured to the housing.
c. Do not exceed the housing maximum depth rating of 60 meters (200 ft.)
d. If the Wet Detection alarm is triggered during use, it means water has
entered the housing. If that happens, try to position the housing lens port
facing down and exit the
water safely in accordance with diving procedures and regulations. Upon
returning to land, remove the camera from the housing. If only a few droplets
of seawater entered
the housing, thoroughly wipe off the seawater droplets with a moist towel and
dry the inside of the housing thoroughly with tissue paper.
e. If seawater leaks into the housing and the Multi-control Device is flooded,
take out the camera, rinse the housing cavity thoroughly with running fresh
water for a few minutes. Then, dry the housing cavity completely and bring it
to your local dealer for servicing immediately.
Connecting the Fiber Optic Cable
a. You can install Olympus Flash FL-LM3 or AOI LED Optical Strobe Trigger
STR-04 on the camera hot shoe and use either one for the external Slave
Flash(es) triggering.
b. This housing is equipped with two Fiber Optic Cable Ports and they are
compatible with AOI Fiber Optic Cables with SS cable plug or other fiber optic
brands using the
standard of Sea & Sea plug.
c. Insert one end of the fiber optic cable into the Fiber Optic Cable Port of
the housing (fig. xvii) and then insert the other end into the fiber optic
cable port on the external
flash or strobe.
IMPORTANT:
a. Check the compatibility of the Filter Optic Cable and multicore fiber optic
cable is recommended and preferable.
b. When you use Olympus Flash FL-LM3 and use only one side of the Fiber Optic
Cable Port, the other blank out Fiber Optic Cable Port must be closed by a
Fiber Optic Plug
(included in housing accessories). Otherwise, the flashlight will emit out
from the blank
c.Rinse the Fiber Optical Cable Ports with running fresh water after every
use, then let it dry naturally. Do not dry inside of the ports with any tool,
this may result in scratches
and reduce the capacity of the optical signal transfer.
Care and Maintenance
a. Rinse the housing exterior thoroughly with running fresh water after every
use.
Depress buttons and rotate knobs/dials repeatedly in freshwater to eliminate
trapped saltwater or debris. Dry the housing and Lens Port with a soft, clean
cloth to avoid
water spotting and damage.
b. To clean the Lens Port Glass, use a mild soap solution or lens cleaner. Do
not rinse the inside of port glass. Do not use alcohol or window cleaner on
the Lens Port Glass.
c. In order to better inspect, position, clean or lubricate the Housing Main
Seal O-ring or Lens Port O-rings, carefully remove the required O-ring by
using the provided AOI
O-Ring Remover/White Balance Card.
d. Clean the O-ring and the O-ring groove by using a microfiber cloth only.
Use AOI
O-Ring Remover/White Balance Card to clean the O-Ring groove. Do not use
cleaning substances other than freshwater. Remove sand, dirt, hair or fibers
that can
prevent a proper housing seal.
e. To lubricate O-rings, apply a small amount of silicone grease (AOI SIGR-5)
on your fingertips, gently pull the O-ring through the fingertips. This will
lightly coat the entire
O-ring with silicone grease. Only use the AOI Silicone Grease supplied or
those approved by AOI. Using other brands of silicone grease may damage the
O-ring. Do
not over-stretch the O-ring.
f. Do not leave the camera and housing in direct sunlight for prolonged
periods. Heat may damage the camera and housing.
g. Dry well and remove the camera prior to travel and storage.
h. Store the housing in a cool and dry place.
IMPORTANT:
Wipe the housing dry and keep water away prior to opening the housing.
Do not allow water to be in contact with the interior of the housing. This
will cause irreparable damage to the Vacuum Analysation and Wet Detection
System (VWS)
and other electronic/electrical components!
Specifications
Model Number | AOI UH-EM5III |
---|---|
Housing Colour | AOI UH-EM5III-BLK |
Black | Camo Blue |
Compatible
Camera Model| Olympus OM-D E-M5 Mark III
Main Material| Housing Body: Polycarbonate
Depth Rating| 60 Meters (200 ft.)
Operating
Environment| Operation : 0 C ~ 40 C (32 F ~ 104 F)
Storage : -20 C ~ 60 C (-4 F ~ 140 F)
Battery for
Vacuum Analysation
and Wet Detection
System (VWS)| Built-in Rechargeable Lithium Polymer Battery (3.7V)
Charging : USB Charger DC 5V, 0.5A (not included)
Approx. 1.5 hours for a full charge
Battery Operation Time : Approx. 100 hours
Dimensions| Approx. 206.20mm (W) x 181.70mm (H) x 113.55mm (D)
Weight| Approx. 1340g
(LCD Monitor Hood and Lanyard included, camera and accessories not included)
AOI is a registered trademark of AOI Ltd. All rights reserved.
All other trademarks are the property of their respective owners.
www.aoi-uw.com
Made in China
6E01015A-00001
Documents / Resources
| AOI
Olympus OM-D E-M5 III Underwater Housing UH-
EM5III
[pdf] User Guide
Olympus OM-D E-M5 III Underwater Housing, UH-EM5III, Olympus OM-D E-M5 III
Underwater Housing UH-EM5III
---|---