BLUERIDGE BP07B Packaged Terminal Air Conditioner Owner’s Manual
- September 16, 2024
- BLUERIDGE
Table of Contents
- BLUERIDGE BP07B Packaged Terminal Air Conditioner
- Safety Precautions
- Before you get start
- Before the installation
- Installation overview
- Complete Unit installation
- Preparations for Unit Installation
- Customize your features
- WALL THERMOSTAT WIRING EXAMPLES
- OPERATION INSTRUCTIONS
- CARE AND MAINTENANCE
- TROUBLESHOOTING
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
BLUERIDGE BP07B Packaged Terminal Air Conditioner
Safety Precautions
- Inside you will find many helpful hints on how to use and maintain your air conditioner properly.
- Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner.
- You’ll find many answers to common problems in the chart of Troubleshooting Tips.
- If you review our chart of Troubleshooting Tips first, you may not need to call for service at all.
- To prevent injury to the user or other people and property damage, the following instructions must be followed.
- Incorrect operation due to ignoring instructions may cause harm or damage. The seriousness is classified by the following indications.
Explanation of Symbols
Warning
The signal word indicates a hazard with a medium level of risk which, if not avoided, may result in death or serious injury.
Caution
The signal word indicates a hazard with a low degree of risk which, if not avoided, may result in minor or moderate injury.
Never do this
This signal indicates that prompt operation is prohibited., if not avoided, may result in Product damage or injury.
Always do this
This signal means that the operation can be performed.
WARNING
- Plug in the power plug properly. Otherwise, it may cause electric shock or fire due to excess heat generation. Do not operate or stop the unit by inserting or pulling out the power plug.It may cause electric shock or fire due to heat generation. Do not damage or use an unspecified power cord. It may cause electric shock or fire.
- Always install a circuit breaker and a dedicated power circuit. Incorrect installation may cause fire and electric shock. Do not operate with wet hands or in a damp environment. It may cause electric shock. Do not direct airflow at room occupants only. This could damage your health.
- Always ensure effective grounding.Incorrect grounding may cause electric shock. Do not allow water to run into electric parts.It may cause the failure of the machine of electric shock. Do not modify the power cord length or share the outlet with other appliances. It may cause electric shock or fire due to heat generation. Unplug the unit if strange sounds, smells, or smoke come from it. It may cause fire and electric shock.
- Do not use the socket if it is loose or damaged. It may cause fire and electric shock. Do not open the unit during operation. It may cause electric shock.
- Keep firearms away. It may cause a fire. Do not use the power cord close to the heating appliances.It may cause fire and electric shock. Do not use the power cord near flammable gas or combustibles, such as gasoline, benzene, thinner, etc. It may cause an explosion or fire.
- Ventilate the room before operating the air conditioner if there is a gas leakage from another appliance. It may cause explosion, fire, and, burns. Do not disassemble or modify the unit. It may cause failure and electric shock.
CAUTION
-
When the air filter is to be removed, do not touch the metal parts of the unit. It may cause an injury.
-
Ventilate the room well when used together with a stove, etc. An oxygen shortage may occur.
-
Do not use strong detergent such as wax or thinner but use a soft cloth.
-
Appearance may be deteriorated due to a change of product color or scratching of its surface. Do not clean the air conditioner with water.
-
Water may enter the unit and degrade the insulation. It may cause an electric shock. Do not use for special purposes. Do not use this air conditioner to preserve precision devices, food, pets, plants, and art objects. lt may cause deterioration of quality, etc.
-
Stop operation and close the window in a storm or hurricane. Operation with windows opened may cause wetting of indoor and soaking of household furniture.
-
When the unit is to be cleaned, switch off, and turn off the circuit breaker.
-
Do not clean unit when power is on as it may cause fire and electric shock, it may cause an injury.
-
Always insert the filters securely. It can cause failure if operated without filters. Please clean the filter once every two weeks.
-
Hold the plug by the head of the power plug when taking it out. It may cause electric shock and damage. Turn off the main power switch when not using the unit for a long time.
-
It may cause failure of product or fire.
Do not place obstacles around air inlets or inside of air-outlets. It may cause the failure of an appliance or an accident. Do not place heavy objects on the power cord and ensure that the cord is not compressed. There is a danger of fire or electric shock. Don’t drink water drained from air conditioner. It contains contaminants and could make you sick. -
Use caution when unpacking and installing. Sharp edges could cause injury.
-
If water enters the unit, turn the unit off at the power outlet and switch off the circuit breaker. Isolate the supply by taking the power plug out and contact a qualified service technician. This appliance is not intended for use by persons(including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
-
Children should be supervised to ensure that they do not play with the appliance.
-
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons to avoid a hazard.
-
The appliance shall be installed under national wiring regulations.
-
Installation must be performed under the requirements of NEC and CEC by authorized personnel only. Do not operate your air conditioner in a wet room such as a bathroom or laundry room.
-
The appliance with electric heater shall have at least 1-meter space to the combustible materials.
-
Contact the authorized service technician for repair or maintenance of this unit.
-
Contact the authorized installer for the installation of this unit.
NOTE
- This air conditioner is designed to be operated under the following conditions:
Cooling operation| Outdoor temp.| 18-(43/26)°C /64-(109/79)°F (18-52°C/64-125°
Ffor special tropical models)
---|---|---
Indoor temp.| 17-(32/23)°C/62-(90/73)° F
Heating operation| Outdoor temp.| -5-(24/18)°C/23-(76/64)° F
Indoor temp.| 0-(27/19)°C/32-(80/66) °F
N o te: (43/26) °C. It means the dry bulb temperature is 43°C and the wet bulb temperature is 26°C
Note: Performance may be reduced outside of these operating temperatures.
Operation of Current Device
The power supply cord contains a current device that senses damage to the
power cord. To test your power supply cord do the following:
- Plug in the Air Conditioner.
- The power supply cord will have TWO buttons on the plug head. Press the TEST button, you will notice a click as the RESET button pops out.
- Press the RESET button again, you will notice a click as the button engages.
- The power supply cord is now supplying electricity to the unit. (On some products this is also indicated by a light on the plug head).
NOTE
- The power supply cord with this air conditioner contains a current detection device designed to reduce the risk of fire. If the power cord is damaged, it cannot be repaired – it must be replaced with a cord from the product manufacturer.
- Do not use this device to turn the unit on or off.
- Always make sure the RESET button is pushed in for correct operation.
- The power supply cord must be replaced if it fails to reset when either the TEST button is pushed or if it cannot be reset. A new one can be obtained from the product manufacturer.
- If the power supply cord is damaged, it cannot be repaired. It MUST be replaced by one obtained from the product manufacturer.
Grounding type wall receptacle
- Power supply cord with 3-prong grounding plug and current detection device.
Electrical Information
The complete electrical rating of your new room air conditioner is stated on
the serial plate. Refer to the rating when checking the electrical
requirements.
- Be sure the air conditioner is properly grounded. To minimize shock and fire hazards, proper grounding is important. The power cord is equipped with a three-prong grounding plug for protection against shock hazards.
- Your air conditioner must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the proper receptacle. Ensure the receptacle is accessible after the unit installation.
- Do not run air conditioner without side protective cover in place. This could result in mechanical damage to the air conditioner.
- Avoid fire hazard or electric shock. Do not use an extension cord or an adapter plug. Do not remove any prongs from the power cord.
Electronic Work
WARNING
BEFORE PERFORMING ANY ELECTRICAL OR WIRING WORK, TURN OFF THE MAIN POWER TO
THE SYSTEM.
For Your Safety
Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
Prevent Accidents
To reduce the risk of fire, electrical shock, or injury to persons when using
your air conditioner, follow basic precautions, including the following:
- Be sure the electrical service is adequate for the model you have chosen. This information can be found on the serial plate, which is located on the side of the cabinet and behind the grille.
- Be sure the air conditioner has been securely and correctly installed according to the installation instructions in this manual. Save this manual for possible future use in removing or installing this unit. When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front and rear coils.
NOTE: The cographs are for explanation purposes only. Your machine may be slightly different. The actual shape shall prevail.
Electrical Requirements
- Electrical Shock and Personal Injury Hazard
- Electrical ground is required on this appliance.
- DO NOT ground to a gas line.
- If cold water pipe is interrupted by plastic,non-metallic gaskets, or other insulating materials,
- DO NOT use for grounding.
- Check with a qualified electrician if you are in doubt as to whether the appliance is properly grounded.
- DO NOT modify power supply cord plug. If it does not fit outlet, have a proper outlet installed by a qualified electrician.
- DO NOT have a fuse in the neutral or grounding circuit.A fuse in the neutral, or grounding circuit could result in an electrical shock. DO NOT use an extension cord with this appliance.
- Failure to follow these instructions could result in electrical shock, serious injury, or death.
Observe all local governing codes and ordinances.
Do not, under any circumstances, remove the power supply cord grounding prong.
NOTE: If codes permit, and a separate grounding wire is used; it is
recommended that a qualified electrician determine that the grounding path is
adequate and not interrupted by plastic, nonmetallic gaskets, or other
insulating materials.
Receptacle wiring
It is your responsibility to provide proper and adequate receptacle wiring,
installed by a qualified electrician.
Electrical requirements
A time-delay fuse or time-delay circuit breaker is also required. A separate
circuit, serving only this appliance, MUST be provided.
NOTE: for details about the parameters of the electric heating function,
see the nameplate on the unit.
NOTE
- The shape may be different according to its model:
Power Card
| | |
---|---|---|---
Power Supply
|
230V,15A
|
230V,20A
|
230V,30A
Before you get start
- Contents of the package and preparation
What is in the Package
- Unit
- Control panel sticker
- Owner’s manual
What you need to purchase
- Wall sleeve and grille
Prepare the following tools
Before the installation
Preparations before installation
- The installation must be carried out in strict accordance with the instructions in this manual.
- Installing your AC should take about 60 minutes.
- We recommend doing this with a helper.
- We’re here if you need us, please contact your local distributor for assistance.
INSTALLATION SIZE AND POSITION REQUIREMENTS
CAUTION
- Be careful! There are sharp edges that can cause serious cuts.
- Install the grille on the wall sleeve prior to installing the wall sleeve in the wall!
Installation size confirmation
- Wall sleeve size requirements (wall hole size should refer to the wall sleeve size)
Confirmation of installation position
NOTE
- To make the appliance work better, please do not place a barrier in the air outlet.
Installation overview
Installation Completion Display
Installing Unit into the wall
- Unit
- Outlet
- Air Intake
- Control panel cover
NOTE
Illustrations in this manual are for explanatory purposes. The actual shape of your unit may be slightly different. The actual shape shall prevail.
Complete Unit installation
NOTE
- Please do this with a helper, or even two helpers.
What you need
Preparations for Unit Installation
- Install the grille on the wall sleeve prior to installing the wall sleeve in the wall
Attach Wall sleeve
- Drill two holes on each side of the wall sleeve and secure it to the studs. DO NOT drill holes in the bottom of the sleeve. Ensure the sleeve is pitched slightly towards the outside. For minimal vibration and noise, make sure the wall sleeve is installed securely and firmly.
Prepare for unit installation
- Carefully remove shipping tapes from the front panel. (See Fig.6) Remove the front panel. (See Fig.7)
Unit Installation
Install and fix the main part of the unit
- Remove the shipping screw from the vent door. (See Fig.8)
- Rotate the vent control lever to either open or close the vent door. (See Fig.9)
NOTE
When the vent control lever is set at CLOSE, only the air inside the room is
circulated and filtered. When set at OPEN, some outdoor air will be drawn into
the room. This will reduce heating or cooling efficiency.
CAUTION
- Do not put obstacles around the air inlet or inside of the air outlet of the unit, such as a window curtain, etc.
- Always insert the filter securely, and clean the filter once every two weeks as required.
Install the unit into the wall sleeve
- Write down or take a picture of the serial number before installing the unit into the wall sleeve.
Install the unit into the wall sleeve
- Lift unit level and slide unit into wall sleeve until firmly against the front of wall sleeve and secure with 4 screws and washers (supplied in the SLEEVE ASSEMBLY ) through the unit flange holes. (See Fig.10 and Fig.11)
Reinstall front panel
- Place tabs over the top rail. Push Inward at the bottom until the panel snaps into place. (See Fig.12)
Customize your features
Product function reset operation
NOTE
- Unit must be powered OFF to effectively change their status.
DIP SWITCHES CONFIGURATIONS
- Please refer to the following table for DIP SWITCHES CONFIGURATIONS operation.
Table 1 DIP SWITCHES CONFIGURATIONS
No. | UP(ON) | DOWN(OFF) | Remarks |
---|---|---|---|
S1 | Electric Heat Only | Electric Heat and Pump Heat | For the Heat Pump |
unit only
S3| Wall Thermostat Enable| Control Panel Enable|
*S4S5*| UPUP:60°F~86°F(16°C~30°C); UPDOWN:65°F~78°F(18°C~26°C);
DOWNUP:63°F~80°F(17°C~27°C); DOWN*DOWN:68°F~75°F(20°C~24°C);|
Two configurations (S4*S5) combine to select set point range.
S6| Fan Continuous Run for Heating| Fan Cycle for Heating|
S7| Fan Continuous Run for Cooling| Fan Cycle for Cooling|
S8| Low temp. Protection enable| Low temp. Protection disable| Optional
S9 (S3UP)| Use other types of wall Thermostat| Use other types of
wall Thermostat| you can consult with the sales agency or manufacturer for
details
S9 (S3
DOWN)
| Use Control Panel only| Use Control Panel or other types of wall
Thermostat| Use control Panel or some types of wall Thermostat, the other one
must be turned of
Sw11| Load delay for 3 seconds| Normal| Optional
Low temp. Protection(optional)
- If unit senses a room temperature below 32℉(0℃), the fan motor and electric strip heat will turn on and warm the room to 40℉(4.4℃). The fan stops a short time after the temperature is satisfied.
Heat and Cool Fan CON/ CYC Dip-switches
- Allows the fan to operate in continuous or cycle modes while the unit is in heating and cooling mode.
CON(Continuous)
- Allows fan to run continuously, circulating air even when the temperature setting has been satisfied. This switch helps to maintain the room temperature closer to the thermostat setting.
CYC(Cycle)
- This setting allows the fan to cycle on and off with the compressor or electric heater.
- The fan stops a short time after the temperature setting is satisfied.
Electric Heat Only (for heat pump unit only)
- This setting is typically used for Emergency Heating.
Setpoint Temperature Limits
- Provides a restricted range of temperature control.
Setpoint Temperature Limits
- Provides a restricted range of temperature control.
Electric Heat Only (for heat pump unit only)
- This setting is typically used for Emergency Heating.
Wall Thermostat control
- A wired wall thermostat can be connected to the unit.If it is, this dip switch must be moved to the Wall Thermostat Enable Position, before the wall thermostat will begin control.
DIP SWITCHES CONFIGURATIONS by PANEL CONTROL(Optional)
NOTE: Unit must be powered OFF to effectively change its status.
- Press the up and down buttons together for 3 seconds to activate the dip switches configurations by panel control (see Fig.4).
- See Table 1 for Dip Switches configurations and functions by panel control.
- NOTE: Press the up and down buttons together for 3 seconds again or no operation within 30 seconds to exit the dip switches configurations by panel control and the unit will save the last settings.
- Display function settings with 2 digitals in LED display window, high (left) for dip switches, low (right) for functions (see Fig.4).
- Press up button to set the dip switches, and press the down button to set the functions.
Table —— DIP SWITCHES CONFIGURATIONS by PANEL CONTROL
No. | High(left) | Low(right) | Remarks |
---|---|---|---|
/ | 0 | 1-by panel control | 0-by dip switches |
S1 | 1 | 1-electric heat only | 0-electric heat and pump heat |
Pump unit only
S3S9| 3| 3-use control panel or some types of wall thermostat; 2-use
other types of wall thermostat; 1-use other types of wall thermostat;
0-control panel enable.| You can consult with the sales agency or manufacturer
for details
S4S5|
4
| 4-62°F~86°F(17°C~30°C); 3-60°F~86°F(16°C~30°C);
2-65°F~78°F(18°C~26°C); 1-63°F~80°F(17°C~27°C);
0-68°F~75°F(20°C~24°C);
|
S6| 6| 1-fan continuous run for heating| 0-fan cycle for heating| Not
available for 1-use other types of wall thermostat
S7| 7| 1-fan continuous run for cooling| 0-fan cycle for cooling
S8| 8| 1-low temp. protection enable| 0-low temp. protection disable|
Optional
SW7| A| 1-front desk control disable| 0-front desk control enable|
Optional
Sw11| B| 1-Load delay for 3 seconds| 0-normal| Optional
NOTE:
- The LED display window will show 00 when you first enter the setting mode, only when you set 01 you can start the next settings.
- To activate the front desk control function, you need to pull the dip switch SW7 to DOWN(OFF) , and then set the panel control to A0 .
- After all set, press up and down buttons together for 3 seconds to exit the operation interface and cut off the power. When re-power on, the settings are activated.
WALL THERMOSTAT TERMINAL (Optional)
IMPORTANT
Only trained, qualified personnel should access the electrical panel on unit
and install electrical accessories. Please contact your local electrical
contractor, dealer, or distributor for assistance.
Thermostat Wire Routing
The thermostat wire is field-supplied. The recommended wire gauge is 18 to
20-gauge solid thermostat wire.
NOTE: It is recommended that extra wires are run to unit in case any are
damaged during installation.The thermostat wire should always be routed around
or under, NEVER through, the wall sleeve.
The wire should then be routed behind the front panel to the easily accessible
terminal connector.
NOTE: Refer to thermostat installation instructions for details on installing wall thermostats.
Installation instruction of some types of wall Thermostat (you can Consult with the sales agency or manufacturer for details)
- Pull the dip switch to the DOWN(OFF) position as shown below.
- Insert the wire connector of the wall thermostat into the relevant terminal according to different shapes as shown above.
Installation instruction of PTAC Wall Thermostat
- Remove the two screws as shown below and take the cover panel down.
TERMINAL | DESIGNATION | MODE B Wire color |
---|---|---|
FC(L) | Front desk control terminal L | Brown |
FC(N) | Front desk control terminal N | Pink |
LOW-FAN | Low fan speed | Purple |
HI-FAN | High fan speed | Green |
4-WAY | 4-way valve; Reverse cycle (Energized in Heat) For heat pump models |
Blue
HEAT2| Electrical heater 2| White
HEAT1| Electrical heater 1| White
COMP| Compressor| Yellow
24V(N)| 24V AC terminal N (Neutral), Common| Black
24V(L)| 24V AC terminal L| Red
CAUTION
UNIT DAMAGE HAZARD
- Failure to follow this caution may result in equipment damage or improper operation.
- Improper wiring may damage unit electronics. Common busing is not permitted. Damage or erratic operation may result.
WALL THERMOSTAT WIRING EXAMPLES
NOTE
- Use terminal 4-way for heat pump connection only.
- Suggest set the compressor protection time to more than 3 minutes in. If set for less than 3 minutes, the compressor will restart-delay 3 minutes still.
- Wall thermostat must be heating changeover 4-way valve.
- For thermostats that have only one fan speed output (on or auto), the fan speed is determined by how the terminal connector is wired. If a Low fan is desired, wire the G output from the thermostat to (LOW-FAN) on the unit’s terminal block.
- If High fan is desired, wire the G output from the themostat to (HI-FAN) on the unit’s terminal block.
- The range of set temperature of the Wall thermostat must agree with the range of DIP switch setting.
- Wall thermostats must be set the type properly in consonance with the unit type: heat pump or no heat pump.
- If the has only one electrical heater output, connect the two terminals of HEAT 1 and HEAT 2, the unit can operate two electrical heaters (only for the unit has two electrical heaters). Otherwise, operate one electrical heater.
- Please do not remove the control panel.
FRONT DESK CONTROL
The controller can handle a switch signal from FC(L) and FC(N) input, called
front desk control. Input must be 24VAC. If the system doesn’t receive a 24VAC
signal, it will turn unit off; otherwise, the unit runs in normal control.
The DIP switch can control the FRONT DESK CONTROL feature. The DIP switch is
on the DOWN position, the unit will be turned off; otherwise, the unit runs in
normal control. See FigB.
OPERATION INSTRUCTIONS
Control Panel
NOTE
- The control panel keypad will look like the following Fig.1. For some models with REMOTE SIGNAL RECEPTOR, the unit can be controlled by the control panel alone or by the remote. NOTE: Some models have no REMOTE SIGNAL RECEPTOR.
Description
1| POWER – Function| · Press the POWER button to turn the unit on or
off.
2| Wireless Function ( same model )| · For the first time to use the
Wireless function, press the button for 5 seconds to initiate the Wireless
connection mode. The LED DISPLAY shows‘AP’to indicates you can set a Wireless
connection.
If the Connection (router) is successful within 8 minutes, the unit will exit Wireless connection mode automatically and the Wireless indicator will illuminate. If the connection is a failure within 8 minutes, the unit exits the Wireless connection
3| Mode – Function| · Push this button to cycle through the modes from COOL-DRY-HEAT-FAN-COOL. The indicator light beside the “MODE” option will illuminate, identifying the mode selected.
· COOL:.Cooling begins automatically when the room temperature is above the set point, and stops when the room temperature is 2°C(4°F)below the set point. But the compressor will run for 5 minutes at least in COOL mode before stopping.
Description
| | · HEAT: For heat pump models, the unit can alternate to run between in reverse cycle heat mode and electric heater mode according to the diference between the setting temperature andthe room temperature.
· The fan motorcycles with the compressor stop.
DRY: In this mode, the air conditioner will generally operate in the form of a dehumidifier. Since the conditioned space is a closed or sealed area, some degree of cooling will continue.
NOTE:
The reverse cycle and electric heater cannot be run at the same time. In the following cases, it is normal that the reverse cycle does not operate.
1. When the outdoor temperature is lower than 4°C/40°F or the room temperature falls to 4.5°C/8°F below the set point temperature.
2. There is a 3-minute minimum compressor run time at any setting to prevent short cycling. The indoor fan motors starts before the compressor and stops after the compressor cycles of.
3. Push the S1 on the DIP SWITCHES to UP (ON) position.
4. When frost builds up to the evaporator coils, the unit will defrost automatically and the compressor will cycle of.
NOTE: When you select AUTO mode, the FAN speed will be automatically adjusted at the setting temperature and room temperature.
· FAN: Fan operation only without heating and cooling.
NOTE: If the unit has DIP SWITCHES feature, the temperature range can be setted is controlled by DIP SWITCHES. See DIP SWITCHES CONFIGURATIONS on page 8 for details.
4
|
– + Up and Down buttons
| · Push the UP (or DOWN) button to increase (or decrease) the set temperature of the unit in cooling or heating mode.The temperature can be set by increments of 1°C (1°F).The setting temperature appears in the display.
NOTE: Press and hold “+” and“-” buttons together for 3 seconds will alternate the temperature display between &°F scale.
5
|
FAN (FAN SPEED) – Function
| · Every time you push this button,the fan speed cycles through the settings as follows: AUTO-HIGH-LOW-AUTO. NOTE: When you select AUTO mode, the FAN speed will be automatically adjusted at the setting temperature and room temperature.In dry mode, the fan speed is controlled at Low speed automatically.
6
|
CONSTANT FAN – Function
| · In cooling mode, press the button to turn on or of the constant fan function. When the function is turned on, the constant fan light will illuminate, identifying the fan continuous run for cooling. When the function is turned of, the constant fan light will go out, identifying the fan cycle run with the compressor stop.
NOTE: Every time the unit is turned on, the function will work as the DIP SWITCHES CONFIGURATIONS
7| PANEL LOCKING – Function| · Long press the open key and continuous air function key for 5 seconds at the same time.Quick check immediately response, no 5 seconds.Turn on or of the lock panel function.The remote control still works. Fast entry, and exit when unlocking function.
NOTE:It will be display ‘LL’ when you locked the control panel.
Description
8| DISPLAY| · Shows the set temperature in°C or°F. While on Fan-only mode,it shows the room temperature.
Control code (on some models):
LC – Pads on the control panel is not available.The unit can be setted by using wire controller only.
FC – Pads on the control panel and wire controller are not available. The unit can be setted by using FRONT DESK CONTROL only.
Error codes:
E0-Failure of EEPROM parameter E3-The fan stall error
E4:Main control and Display communication error AS – Room temperature sensor error;
ES – Evaporator temperature sensor error; CS – Condenser temperature sensor error; OS – Outside temperature sensor error; HS – Exhaust temperature sensor error; LE – Wire controller error;
NOTE: When error occurs, unplug the unit and plug it back in.If the error repeats, call for service.
Other codes:
LO – Room temperature is lower than 0°C/32°F; HI – Room temperature is higher than 37°C/99°F; FP – Low temp. Protection.
NOTE: All the illustrations in this manual are for explanation purposes only. Your air conditioner may be slightly diferent. The actual shape shall prevail.
Accessories
NOTE: When the unit displays LC (Pads on the control panel is not
available. The unit can be setted by using wire controllers only). You can
install the Accessory on the control panel.
NOTE: For some models, there is a corresponding operation that happens
after 3 seconds when pressing any button.
NOTE: When there are wide differences between USERS MANUAL and Remote controller Illustration on function description, the description on USERS MANU shall prevail.
CARE AND MAINTENANCE
CAUTION
UNIT DAMAGE HAZARD Failure to follow this caution may result in equipment
damage or improper operation. Airflow restrictions may cause damage to the
unit.
FRONT PANEL AND CASE
- Turn unit off and disconnect power supply. To clean, use water and a mild detergent. use bleach and abrasivers.Some commercial cleaners may damage the plastic parts.
OUTDOOR COIL
- Coil on outdoor side of unit should be checked regularly.Unit will need to be removed to inspect dirt build-up that will occur on the inside of the coil. If clogged with dirt and soot ,coil should be professionally cleaned.Clean inside and outside of outdoor coils regularly.
NOTE: Never use a high-pressure spray on coil.
CAUTION
Failure to follow this caution may result in equipment damge or improper
operation.
Do not operate unit without filters in place.If a filter becomes torn or
damaged, it should be replaced immediately.
Operating without filters in place or with damaged filter will allow dirt and
dust to reach indoor coil and reduce cooling, heating,airflow and effciency of
unit. Airflow restriction may cause damage to unit.
- The most important thing you can do to maintain unit eciency is to clean the filters once every two weeks as required. Clogged filters reduce cooling,heating and airflow.
- Keeping filters clean will:
- Decrease cost of operation.
- Save energy.
- Prevent clogged indoor coil.
- Reduce risk of premature component failure.
To Clean Air Filters
- Vacuum off heavy soil. Run water through filter. Dry thoroughly before replacing.
VENT DOOR FILTER:
IMPORTANT:TURN UNIT OFF BEFORE CLEANING.
- If the vent door is open,access requires the removal of the unit from the wall sleeve.Clean the vent filter twice a year or as required.
- Make sure to remove the shipping screw from the vent door.(See.Fig.8)
- Rotate the vent control lever to open the vent door. (See. Fig.15)
- Remove four screws from the vent door filter. (See.Fig.15)
- First pull out the vent door steel wire from the hole of the vent door, then take off the vent door and filter. (See.Fig.15)
- Clean the filter.Dry thoroughly before replacing.
- Replac the vent door and filter,reinstall the four screws.
- Reinsert the vent door steel wire into the hole of the vent door.
TROUBLESHOOTING
Before calling for service, review this list. It may save you time and money. This list includes common occurrences that are not the result of defective workman-ship or materials in this appliance.
Problem | Solution |
---|---|
UNIT DOES NOT START | Unit may have become unplugged. Check that plug is |
plugged securely in wall receptacle. NOTE:Plug has a test/reset button on
it.Make sure that the plug has not tripped.
Fuse may have blown. Replace the fuse. See Note 1.
Unit may be of. Reset circuit breaker.See Note 1.
Unit may be in a protection mode. Turn unit on (bottom right button on
keypad).
UNIT NOT COOLING/ HEATING ROOM| Unit air discharge section is blocked.
Make sure that curtains,blinds or furniture are not restricting or blocking
unit airflow.
Temperature setting is not high or low enough. NOTE: Setpoint limits may not
allow the unit to heat or cool the room to the temperature desired.Check
section on dipswitch settings. Reset to a lower or higher temperature setting.
Unit air filters are dirty. Remove and clean filters.
Room is excessively hot or cold when unit is started. Allow suffcient amount
of time for unit to heat or cool the room. Start heating or cooling early
before outdoor temperature,cooking heat or gatherings of people make room
uncomfortable.
Vent door left open. Close vent door.
Unit may be in a protection mode. Check dipswitch and wall thermostat settings for desired comfort.
Compressor is in time delay. Wait approximately 3 minutes for compressor to
start.
DISPLAY HAS STRANGE NUMB- ERS/CHARACTERS ON IT| The unit may be in a
protection mode.
The unit may be in a protection mode.
UNIT MAKING NOISES| Clicking,gurging and whooshing noises are normal
during operation of unit.
WATER DRIPPING OUTSIDE| If a drain kit has not been
installed,condensation runof during very hot and humid weather is normal.See
Note 2.If a drain kit has been installed and is connected to a drain
system,check gaskets and fittings around drain for leaks and plugs.
WATER DRIPPING INSIDE| Wall sleeve is not installed level. Wall sleeve
must be installed level for proper drainage of condensation .Check that insta
llation is level and make any necessary adjustments.
Problem| Solution
---|---
ICE OR FROST FORMS ON INDOOR COIL
| Low outdoor temperature. When outdoor temperature is approximately 55OF or below,
frost may form on the indoor coil when unit is in Cooling mode.Switch unit to FAN operation until ice or frost melts.
The filters are dirty. Remove and clean filters.
COMPRESSOR PROTECTION
| Power may have cycled,so compressor is in a restart protection.
Random Compressor restart – Whenever the unit is plugged in,or power has been restarted, a random compressor restart will occur. After a power outage,the compressor will restart after approximately 3 minutes.
Compressor Protection – To prevent short cycling of the compress or, there is a random startup delay of 3 minutes and a minimum compressor run time of 3 minutes.
ELECTRIC HEATING FAILURE
|
Clean the evaporator once every three months by professional people.
NOTES
- If circuit breaker is tripped or fuse is blown more than once,contact a qualified electrician.
- If unit is installed where condensation drainage could drip in an undesirable location,an accessory drain kit should be installed and connected to drain system.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>