LANCOM XS-3550YUP Fully Managed Access Switches User Guide

September 16, 2024
LANCOM

LANCOM XS-3550YUP Fully Managed Access Switches

Product Information

Specifications:

  • Model: LANCOM XS-3550YUP
  • Configuration Interfaces: RJ-45 & micro USB (Console)
  • TP Ethernet Interfaces:
    • Interfaces 1-40: 10M / 100M / 1G PoE+
    • Interfaces 41-48: 1G / 2.5G / 5G / 10G PoE++
  • SFP28 Interfaces:
    • Interfaces 49-50: 10G / 25G

Product Usage Instructions

Connecting and Configuring:

  1. Connect the configuration interface using the micro USB cable to the device for configuration.
  2. Alternatively, use the RJ-45 interface with the provided serial configuration cable.

Ethernet Interfaces:

  1. Use Ethernet cables to connect interfaces 1-40 to your PC or LAN switch.
  2. Connect interfaces 41-48 with at least CAT6a/CAT7 cables to your PC or LAN switch.

SFP28 Interfaces:

  1. Insert LANCOM SFP modules into interfaces 49-50.
  2. Use compatible cables with the SFP modules as per mounting instructions.
  3. Refer to www.lancom-systems.com/SFP-module-MI for detailed mounting instructions.

Power Supply:

  1. Use the power supply module with mains connection socket at the rear panel to supply power to the device.
  2. Use the supplied power cord or a country-specific LANCOM power cord for power connection.

Maintenance and Operation:

  1. Ensure a professionally installed power supply near a freely accessible power socket.
  2. Keep the power plug of the device easily accessible at all times.
  3. Do not use third-party accessories like SFP and DAC as support is not provided.

FAQ:

  • Q: What should I do if the System LED is red?
    A: The red System LED indicates a hardware error. Please refer to the user manual for troubleshooting steps or contact customer support for assistance.

  • Q: How do I reset the device?
    A: To reset the device, press and hold the Mode/Reset button until all port LEDs glow. This will perform a configuration reset and device restart.

OVERVIEW

  1. Configuration interfaces RJ-45 & micro USB (Console)
    Connect the configuration interface via the included micro USB cable to the USB interface of the device you want to use for configuring/monitoring the switch. Alternatively, use the RJ-45 interface with the provided serial configuration cable.

  2. TP Ethernet interfaces 10M / 100M / 1G PoE+
    Use Ethernet cables to connect interfaces 1 to 40 to your PC or a LAN switch.

  3. TP Ethernet interfaces 1G / 2.5G / 5G / 10G PoE++
    Connect the interfaces 41 to 48 via Ethernet cable with at least CAT6a / CAT7 standard to your PC or a LAN switch.

  4. SFP28 interfaces 10G / 25G
    Insert suitable LANCOM SFP modules into the SFP28 interfaces 49 to 50. Choose cables that are compatible with the SFP modules and connect them as described in the SFP modules mounting instructions: www.lancom-systems.com/SFP-module- MI.

  5. Power supply module with mains connection socket (rear panel)
    Supply the device with power via the power supply socket of the power supply module. Use the supplied power cord or a country-specific LANCOM power cord. To remove the power supply module, disconnect the module from the power supply and then pull the plug out of the module. While pressing the release lever ➇ to the left, you can pull the module out of the device by the handle ➆.

  6. Additional slot for power supply module with mains connection socket (rear panel)
    To install an additional power supply module, remove the corresponding module bay cover by loosening both associated screws and push the power supply module in as far as it will go until the release lever ➇ audibly engages. Check by pulling the handle ➆ that the module cannot be removed from the bay without the release lever ➇ being pressed to the left.

Before initial startup, please make sure to take notice of the information regarding the intended use in the enclosed installation guide!
Operate the device only with a professionally installed power supply at a nearby power socket that is freely accessible at all times.
The power plug of the device must be freely accessible.
Please note that support for third-party accessories (SFP and DAC) is not provided.

FEATURES

? System / PWR A / PWR B / Link/Act/Spd / PoE LED

  • System: off Device powered off
  • System: Green device operational
  • System: red Hardware error
  • PWR A / PWR B: off Power supply module A or B not installed
  • PWR A / PWR B: green Status of the power supply module A or B OK
  • Link/Act/Speed: green
  • Port LEDs show link/activity / port speed status
  • PoE: green Port LEDs show PoE status

? Mode- / Reset button

  • Short press Port LED mode switch
  • ~5 sec. pressed Device restart
  • Pressed until all port LEDs glow Configuration reset and device restart

? TP Ethernet ports 10M / 100M / 1G PoE+

  • LEDs switched to Link/Act/Speed mode
    • Off Port inactive or disabled
    • Green Link 1 Gbps
    • Green, blinking Data transfer, link 1 Gbps
    • Orange Link < 1 Gbps
    • Orange, blinking Data transfer, link < 1 Gbps
  • LEDs switched to PoE mode
    • Off Port inactive or disabled
    • Green Port enabled, power supply to connected device
    • Orange Hardware error

? TP Ethernet ports 1G / 2.5G / 5G / 10G PoE++

  • LEDs switched to Link/Act/Speed mode
    • Off Port inactive or disabled
    • Green Link 10 Gbps
    • Green, blinking Data transfer, link 10 Gbps
    • Orange Link < 10 Gbps
    • Orange, blinking Data transfer, link < 10 Gbps
  • LEDs switched to PoE mode
    • Off Port inactive or disabled
    • Green Port enabled, power supply to connected device
    • Orange Hardware error

? SFP28 ports 10G / 25G

  • Off Port inactive
  • Green Link 25 Gbps
  • Orange Link < 25 Gbps

? ? Power supply unit (rear panel)

  • DC OK: green, blinking Secondary power supply OK
  • DC OK: red, blinking Secondary power supply failure
  • AC OK: green, blinking Primary power supply OK
  • AC OK: red, blinking Primary power supply failure

Hardware

  • Power supply Exchangeable power supply (110-230 V, 50-60 Hz)
  • Environment Temperature range 0–40°C; short-term temperature range 0–50°C; humidity 10–90%, non-condensing
  • Housing Robust metal housing, 19“ 1U (442 x 44 x 375 mm > W x H x D) with removable mounting brackets, network connectors on the front
  • Number of fans 1

Interfaces

  • ETH 40 TP Ethernet ports 10 / 100 / 1,000 Mbps PoE+ 8 TP Ethernet ports 1,000 / 2,500 / 5,000 / 10,000 Mbps PoE++
  • SFP28 2 SFP28 ports 10 / 25 Gbps

Package Content

Mounting brackets 2 19” brackets for rack mounting; If an additional rear support surface is required for more stable mounting of the switch, please use the LANCOM Switch Rack Mount L250, item no.: 61432, which is available as an accessory.
Power supply 1 exchangeable power supply LANCOM SPSU-920, expandable to 2 LANCOM SPSU-920 power supplies (hot swappable, for redundancy operation)
Cable 1 IEC power cord, 1 serial configuration cable 1.5 m

Please observe the following when setting up the device:

  • For devices to be operated on the desktop, please attach the adhesive rubber footpads
  • Do not rest any objects on top of the device
  • Keep all ventilation slots on the side of the device clear of obstruction
  • Mount the device into a 19” unit in a server cabinet using the provided screws and mounting brackets.

Hereby, LANCOM Systems GmbH | Adenauerstrasse 20/B2 | D-52146 Wuerselen, declares that this device complies with Directives 2014/30/EU, 2014/35/EU, 2011/65/EU, and Regulation (EC) No. 1907/2006. The full text of the EU Declaration of Conformity is available at the following Internet address: www .lancom-systems.com/doc

LANCOM, LANCOM Systems, LCOS, LANcommunity and Hyper Integration are registered trademarks. All other names or descriptions used may be trademarks or registered trademarks of their owners. This document contains statements relating to future products and their attributes. LANCOM Systems reserves the right to change these without notice. No liability for technical errors and / or omissions.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals