KEMPPI S1065 Welding Helmet Instruction Manual
- September 14, 2024
- KEMPPI
Table of Contents
- KEMPPI S1065 Welding Helmet
- Product Usage Instructions
- Introduction
- Safety
- Technical data
- Points for attention
- Storage and maintenance
- Unpacking/Assembly
- [Before use/Fitting (see fig. 7)]](#Before+use%2FFitting+%28see+fig.+7%29%5D)
- LCD and Operation
- Maintenance
- SPECIFICATION
- TROUBLESHOOTING
- Documents / Resources
KEMPPI S1065 Welding Helmet
Specifications
- Helmet shell: 16321 KMP W15 E 1-M CE
- Filter: 4/9-13KMP 1/1/1/1/379 CE
- Light shade: 4
- Dark shade: 9-13 DIN
- Optical class: 1
- Diffusion of light class: 1
- Variations in luminous transmittance class: 1
- Angle dependency class: 379 CE
Product Usage Instructions
Introduction
This operating manual is divided into two parts: the welding helmet and the
powered air-purifying respirator (S1005 PAPR). Used together, they form the
S1065 respiratory protection system, providing protection for the welder’s
eyes, face, and respiratory system.
Points for Attention
- Ensure the helmet is used in the correct condition and check it according to the Safety Warning content.
- Periodically inspect and clean the outer protection plate of the helmet to maintain visibility. Replace if damaged.
FAQ
Q: What is the purpose of the S1065 welding helmet?
A: The S1065 welding helmet is personal protective equipment designed for
welders and fabrication personnel, providing protection for various welding
processes.
User and maintenance manual
Markings
Helmet shell: 16321 KMP W15 E 1-M CE
16321| Standard reference
KMP| Manufacturer
W| Welding protector
15| Maximum filter shade
E| Impact level
1-M| Average medium head size
CE| European conformity marking
Filter: 4/9-13KMP 1/1/1/1/379 CE
4| Light shade
9-13| Dark shade DIN
KMP| Manufacturer
1| Optical class
1| Diffusion of light class
1| Variations in luminous transmittance class
1| Angle dependency class
379 CE| Standard reference and conformity marking
Part I: Welding helmet
Spare parts (Fig. 1: 1-6)
- SP75114 1. S1065 Helmet shell + face seal
- SP75103 2. Face seal
- SP75101 3. Headband with air duct
- SP75111 4. Outer protection plate, 114x133x1mm
- 9875061 5. Auto darkening welding filter S006
- SP75110 6. Inner protection plate, 106x66x1mm
Introduction
This operating manual is divided in two parts: the welding helmet and the powered air-purifying respirator (S1005 PAPR). Used together, the helmet and the respirator form the S1065 respiratory protection system, which protects the welder’s eyes, face and respiratory system.
About S1065 welding helmet
The S1065 product is personal protective equipment (PPE) for welders and
fabrication personnel. It is designed for arc welding (MMA, MIG/MAG, TIG),
spraying, gouging and cutting.
The helmet provides the users with protection for the eyes and face. The
helmet includes an auto-darkening welding filter (ADF). S1065 welding helmet
complies with the requirements of PPE Regulation 2016/425.
About this manual
Read this manual carefully before using the equipment for the first time. Pay
particular attention to the safety instructions.
| Convention| Used For
---|---|---
| Note| Gives the user a piece of information of particular importance.
| Caution| Describes a situation that may result in damage to the equipment or
system.
| Warning| Describes a potentially dangerous situation that may result in
personal damage or fatal injury.
Disclaimer
While every effort has been made to ensure that the information contained in
this guide is accurate and complete, no liability can be accepted for any
errors or omissions. Kemppi reserves the right to change the specification of
the product described at any time without prior notice. Do not copy, record,
reproduce or transmit the contents of this guide without prior permission from
Kemppi.
Safety
The S1065 personal protective equipment helps protect the wearer’s eyes from harmful radiation including visible light and ultra-violet/infrared radiation resulting from certain welding processes.
Warning
- It is strictly forbidden to use any other than Kemppi branded parts or accessories with Kemppi’s personal protection equipment. If you do not respect this safety regulation, serious damage for your health may occur.
- We recommend a usage period of 5 years. The period of use depends on various factors such as use, cleaning, storage and maintenance. Inspect the helmet before each use. Replace damaged or worn parts.
- Use all adjustment features for maximum protection.
- Never weld with the welding visor up or without the welding filter.
- If the auto-darkening filter (ADF) does not darken when the arc ignites, stop welding immediately. In-spect the ADF and its power supply. Change if necessary.
- Always use welding filters together with suitable protection plates.
- Never use a welding filter without the inner protec-tion plate.
- Never use a scratched or damaged welding filter and ocular.
- Materials which may come into contact with the wearer’s skin may cause allergic reactions to susceptible individuals.
- Only operate this product within the temperature range -5…+55 °C.
- The product is not intended for use in environments with a risk of explosion.
- The helmet does not protect against explosive devic-es or corrosive liquids.
- The helmet is not suitable for laser welding and oxy-acetylene welding/cutting processes.
- The helmet gives designed protection against high-speed particles only at room temperature and only when all helmet components are properly attached, as described in the manual.
- When the helmet is worn over spectacles, they may transmit the impact of high speed particles, thus creating a hazard to the wearer.
- If the impact level symbols are not equal on both the lens/filter and the frame, then it is the lower level that shall be assigned to the complete protector.
- The protections corresponding to the code numbers/letter 7, 9, CH are provided by the complete protector only if the respective symbols are equal on both the lens and the frame.
- Protectors that have been subject to impact shall not be used and shall be discarded and replaced.
- Protector can affect the recognition of colours and / or signal light detection.
- Not suitable for driving and road use.
Adjusting headband (see fig. 10)
- Headband top (a) – Adjust the headband to the correct depth on the head to ensure correct balance and stability.
- Headband tightness (b) – Press the adjustment knob located on the back of the headband and turn it to the desired tightness.
- Distance adjustment (c) – To adjust the distance between the face and the lens, loosen both outside tension knobs and release them from the adjustment slots by pushing them inwards. Slide the helmet forwards or backwards to the desired position and tighten. Both sides must be in line for a correct view.
- Angle adjustment (d) – The four pins on the right side of the headband top provide adjustment for the forward tilt of the helmet. To adjust, loosen the right outside tension adjustment knob, then lift the constraint arm tab and move it to the desired position and tighten the tension adjustment knob.
Technical data
- Complies with standards: PPE Regulation 2016/425,
- N ISO 16321-2:2021, EN ISO 16321-1:2022,
- EN 379:2003+A1:2009
- Filter model: S006
- Filter dimension: 114 x 133 x 9.5 mm
- View area: 100 x 60 mm
- Optical classification: 1/1/1/1
- Darkening degree: DIN 4/9-13
- UV/IR protection: Protection at all times
- Sensitivity: Stepless
- Delay time: 0.1-0.9 s
- Reaction time: < 0.1 ms
- Power supply: Solar cell, replaceable lithium battery
- Battery: 2 x CR2450
- Low battery indicator: Yes
- Grinding function: Yes
- Operating temperature: -5°C – +55°C Manufacturer: Kemppi Oy, PL 13, Kempinkatu 1, 15801 Lahti, Finland
- Certified by: DIN CERTCO Gesellschaft für Konfor-mitätsbewertung mbH
- Alboinstraße 56, 12103 Berlin, Germany
- Notified Body No. 0196
Auto-darkening filter functions (see fig. 11)
-
The power supply of the auto-darkening helmet is provided by solar cells with two lithium batteries.
-
Darkness selection – Adjust to the optimum darkness as needed. Press the “SHADE” button to choose the Shade number range 9-13 according to the current welding process.
-
Delay time selection – Press the “DELAY” button to choose the Delay option from 1 to 5 (0.1-0.9 seconds).
-
Sensitivity selection – Press the “SENSITIVITY” button to choose the Sensitivity option to alter the sensitivity to ambient light.
Turn to 1: The photosensitivity becomes lower.
Suitable for high amperage welding and welding in bright light conditions (lamp light or sun light). Turn to 5: The photosensitivity becomes higher. Suitable for steady arc processes such as TIG welding. -
Grinding function – Press the “WELD/GRIND” button to choose the Grinding option. The grinding function indicator light flashes at the same time. To avoid any harm to eyes, do not conduct welding while on grinding mode.
-
Battery indicator – The battery indicator light is in the top right-hand corner. We recommend replacing the battery when the light is flashing.
Points for attention
- Make sure that the helmet is used in correct condition and check it according to Safety Warning content.
- The outer protection plate of helmet should be periodically inspected and cleaned, keep it clear. If the plate breaks, cracks, dents or has other problems that affect visibility, it must be replaced.
- In order to operate more efficiently and safely, please select correct dark shade number.
- Make sure that the sensor receives the arc light completely, otherwise the filter will not darken or flickers.
- Check if the ADF switches in to the dark mode in front of a bright light source before starting the welding process
- Use the automatic filter at temperature between- 5°C – +55°C.
- Do not disassemble the filter. Any problems arising, please contact your local Kemppi dealer.
Storage and maintenance
- When not in use, the filter should be stored in a dry place within the temperature range of -10°C – +60°C. Prolonged exposure at temperatures above 45°C may decrease the battery lifetime of the filter. lt is recommended to keep the solar cells of the filter in the dark or not exposed to light during storage in order to maintain the powerdown mode. This can be achieved by simply placing the filter face down on the storage shelf. Both inner and outer protection plates (polycarbonate), must be used in conjunction with the auto-darkening filter in order to protect it against permanent damage.
- lt is always necessary to keep the solar cells and the light sensors of the filter free of dust and spatters: cleaning can be done with a soft tissue or a cloth soaked in mild detergent.
- Never use aggressive solvents such as acetone.
- lf protection screens are in any way damaged, they must be immediately replaced.
Part II: S1005 PAPR
Spare parts (see fig. 1: 7-17)
Code Description
- SP75001 7. Filter cover
- SP75004 8. Spark arrestor, 10 pcs
- SP75002 9. Pre-filter, 10 pcs
- SP75003 10. Particle filter, 4 pcs
- SP75000 11. S1005 PAPR blower unit
- SP75006 12. Belt + Shoulder harness
- SP75005 13. Rechargeable Li-ion battery
- SP75008 14. Battery charger, 240V
- SP75010 15. Air hose + cover
- SP75007 16. Air flow meter
- SP75009 17. Tool bag
Introduction
The S1065 respiratory protection system is a combined face and respiratory
protection device for increased safety and comfort during welding. Please read
these instructions carefully before unpacking.
The fresh air system must not be used:
-
In a dangerous environment for the user’s health and safety, an environment with an oxygen level below 17% or containing unknown substances.
In confined or non-ventilated environments. -
Near flames or projections.
-
In an explosion risk zone.
-
If the filter is not installed.
Approvals
The system complies with the requirements of PPE Regulation 2016/425 and
European Standard EN 12941: 1998+A1:2003+A2:2008 TH3 R SL. The Respiratory
System is designed to provide a supply of filtered air via an air hose to a
welding helmet. The equipment can be used in environment that requires a class
TH3 P breathing protection device. It protects against particulate
contamination.
- All components used in fresh air system must be manufacturer approved parts, and must be used in accordance with the instructions in this manual.
- The approval is not valid if the product is incorrectly used together with non-approved parts or components.
- Only the particle filter and pre-filter can be used together with this system. Filters from other manufacturers should under no circumstances be used.
Warnings and limitations to use
Before each use, inspect the fresh air system for damage and verify that it
operates properly. Before using the fresh air system, test air flow to verify
it is providing an adequate volume of air. Always wear the fresh air system
and do not remove the helmet or turn off the air filter unit until outside the
contaminated area. Otherwise, there is a risk of high concentration of CO2 and
oxygen level in the helmet will fall, thus little or no protection is given.
If you are not sure about the concentration of pollution, or about equipment
performance, ask the industrial safety engineer.
The manufacturer is not responsible for injury due to the following incorrect
use or incorrect choice of equip-ment.
Warning
- Respiratory protection devices should be used by well-trained and qualified persons only.
- Before using the devices ensure you have understood that at very high work rates the pressure in the device may become negative at peak inhalation flow.
- Before and during the use of the devices, attention should be paid to possible incorrect use and, if necessary, to the possibility of hoses and/or cables getting looped or stuck.
- If the devices are in a power-off state before or during use, little to no respiratory protection should be expected. This condition is considered abnormal.
- Please leave the work place and remove the welding helmet, when the devices are in the power-off state a rapid build-up of carbon dioxide and depletion of oxygen within the hood occur.
- The user should not confuse the markings on a filter relating to any standard other than EN 12941 with the classification of this device when used with this filter.
- DO NOT use with the blower unit switched off.
- DO NOT use in an atmosphere that is immediately hazardous to user hygiene or health and/or has oxygen content of less than 19.5% or contains unknown substances.
- DO NOT use in an explosive atmosphere.
- DO NOT use in confined spaces or areas of poor ventilation
- DO NOT use in high winds.
- DO NOT alter or modify in any way.
- DO NOT allow water or other liquids to enter the impeller chamber, the filter or battery compartment.
Unpacking/Assembly
Check that correct number of components has been supplied, as in figure 3-1.
Check that the apparatus is complete, undamaged and correctly assembled. Any
damaged or defective parts must be replaced before use.
If any of the above components are not included in your kit, please contact
your local Kemppi dealer immediately.
Filter replacement (see fig. 2)
- Remove the filter cover by pressing in the latch of the filter cover. The filter cover is released.
- Remove the used filter by lifting it out from the filter cover.
- Remove the pre-filter.
- If the spark arrestor is dirty, clean it (blower).
The pre-filter and filter expected lifetime is 12 months. When under intensive use, check the filter cleanliness periodically and if needed, change them more often than every 12 months.
Installing the battery/Charging (see fig. 3)
- Slide the battery towards the back of the filtration unit.
- Make sure that the battery is locked in position.
- The battery can be charged on the filtration unit or separately.
The battery is partially charged when deliv-ered. It must be charged to 100%
before the first use. It is recommended to charge the batteries to 100% before
each use.
The charger must not be used for anything else than it was designed for. Do
not charge the battery in a potentially explosive area. The charger must only
be used indoors. The charger regulates the charge automatically, once the
battery is fully charged, it will maintain it at a 100% (floating charge). The
charge time is 3 – 4 hours.
The battery will discharge itself after long storage periods. Always charge
the battery if the device has been stored for more than 15 days. Once the
battery is new or has been stored for more than 3 months, charge it and
discharge it at least twice in a row to reach the nominal/rated charge
capacity.
Battery charge
- Connect the charger to the mains.
- Connect the battery to the charger. The connector is above the battery.
- The state of charge is indicated by a red LED on the mains charger.
- Once the charge is finished, the floating charge becomes active: the red LED switches off and a green LED switches on.
- Disconnect the charger from the mains (do not keep the charger plugged to the mains if it’s not in use).
Installing the fresh air system on the belt (see fig. 6)
- Remove the belt’s release buckle.
- Remove the fastening belt from the waist connector’s 2 belt loops.
- Pass the fastening belt through the fresh air system’s 2 belt loops.
- Position the Velcro® between the 2 loops.
- Flip the filtration system and attach the Velcro® on the belt.
- Put the fastening belt back through the 2 belt loops.
- Put the buckle back.
- Attach the harness to the belt’s 4 plastic rings.
Make sure the belt is securely fastened.
Connecting the air hose (see fig. 4)
- Connect the air hose to the respiratory system and turn it clockwise to lock in place.
- Connect the other end of the hose to the air duct at the headband in the same way. Check that the air hose is securely connected. If the hose is broken, replace it. All components must be installed/ used in accordance with this manual to enable the equipment to provide the specified protection. If any component is missing, or if anything is not clear, contact the supplier.
Adjust airflow rate (see fig. 5)
The airflow rate in the middle and both sides of the air duct outlet can be adjusted by a switch installed on the airduct.
- Counter-clockwise adjust the switch, airflow rate from middle outlet will be 20% and both side outlet will be 80%
- Clockwise adjust the switch, airflow rate from middle outlet will be 80% and both side outlet will be 20%
All components must be installed/used in accordance with this manual if the equipment is to offer the specified protection. If any component is missing, or if anything is not clear, please contact your local Kemppi dealer.
Before use/Fitting (see fig. 7)]
Airflow test
- Connect the air hose to the powered air-purifying respirator and turn it clockwise to lock it.
- Insert the flowmeter at the tip of the hose.
- Press the ON button and hold the hose in a vertical position at eye level.
- The air flow is sufficient if the marble reaches the minimum flow level O.
The airflow must be tested before using.
Warning
If the marble can’t reach the minimum flow level, don’t use the system. Change the filter or the battery and retest the air flow.
Airflow alarm test (see fig. 8)
-
Remove the air hose from the air duct and PAPR.
Press ON button at the PAPR unit. -
Cover the air output with your hand and wait approximately 15 seconds.
If the alarm does not work, please contact your Kemppi dealer.
Fitting (see fig. 9)
- Pull down the face seal ring and put on the helmet.
- Adjust the headband to suitable tightness (push and turn left to loosen, turn right to tighten)
Make sure the face seal is positioned properly.
Warning
If the face seal is not tight, the respiratory protection system may not offer
the best possible protection.
LCD and Operation
LCD display screen
There is a LCD display screen on S1065 Powered airpurifying respirator to
show the working system condition.
- Indicator 1 shows the data of current air flow.
- Indicator 2 shows the level of the airflow.
- Indicator 3 shows the filter condition.
- Indicator 4 shows the battery charge level.
- Indicator 5 shows the temperature of the battery.
Any indicator will flash if there are any disfunctions on S1065 respiratory protection system.
Operation
- The system will turn off the turbo unit if you long press the OFF button for more than 3 seconds.
- The system will shut down the entire circuit and switch to sleep mode if not used for more than 30 minutes. Pressing the ON button activates the system.
- The system must be operated in the temperature range of -5°C to +55°C and relative humidity less than 90%RH.
Maintenance
- The S1065 Powered air-purifying respirator must be checked regularly and must be changed if it is damaged and has leakage.
- The filter must be replaced if it is broken or blocked and does not provide sufficient airflow.
- The air hose must be replaced if it is broken or has crevasse.
- When low battery indicator alarms, the battery must be charged.
- Use a soft cloth to wipe the external surfaces. Don’t use water!
- The filter should be replaced together with the pre-filter.
Storage
The S1065 Powered air-purifying respirator must be stored in a dry, clean
area, within the temperature range of -10°C – +60°C and relative humidity less
than 90%RH. If the equipment is stored at temperature below 0°C, the battery
must be allowed to warm up to achieve full battery capacity. The equipment
must be protected from dust, particles and other contamination.
If the equipment is not used for a long time, the battery should be fully
charged, removed from powered air-purifying respirator unit and stored
separately.
Transport the equipment in its original tool bag and away from direct
sunlight.
SPECIFICATION
- Manufacturer: Kemppi Oy, PL 13, Kempinkatu 1, 15801 Lahti, Finland
- Certified by: Occupational Safety Research Institute v.v.i.
- Jeruzalemska 1283/9, 110 00 Praha 1, Czech republic.
- Notified Body No. 1024
Warning sound indication
Each grid stands for a period of 100 ms. Gray is the beep sound and blank grid
is a quiet period. If several continued grids are in gray then there’s a
continuous beep sound.
For example, when the current is overloaded, the system sounds like
beep~beep~beep~.
TROUBLESHOOTING
S1065 Respiratory protection system
EN 12941:1998
+A1:2003
+A2:2008
| Standard reference
TH3| System protection level
P / R| Particle filter / Reusable type of particle filters
SL| Tested against solid and liquid particles
CE / 2797| Conformity marking / Certification authority
CE mark followed by number of notified body who carried out module D surveillance.
Helmet | Filter | |
---|---|---|
16321 | KMP | W15 |
Declarations of Conformity
Documents / Resources
|
KEMPPI S1065 Welding
Helmet
[pdf] Instruction Manual
S1065, S1065 Welding Helmet, Welding Helmet, Helmet
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>