ICON PROCESS CONTROLS TVF-450 Industrial Flow Batching Controller User Guide
- September 13, 2024
- ICON PROCESS CONTROLS
Table of Contents
- ICON PROCESS CONTROLS TVF-450 Industrial Flow Batching Controller
- Symbol Explanation
- Basic Requirements | User Safety
- Specifications
- Front Panel Description
- Function of Push Buttons
- Dimensions
- Wiring Diagram
- Wire Connection
- INSTALLATION
- Terminal Descriptions
- Power Supply & Relay Connection
- Suppression Circuit Connection
- OC-Type Output Connection
- Flow Meter Connections
- Programming K Factor
- Programming Relays
- Programming Batching
- Programming Output (For 4-20mA Output Models)
- Resetting Batch
- Resetting Totalizer
- Setting Decimal Point
- Warranty, Returns, and Limitations
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ICON PROCESS CONTROLS TVF-450 Industrial Flow Batching Controller
Symbol Explanation
- This symbol denotes especially important guidelines concerning the installation and operation of the device. Not complying with the guidelines denoted by this symbol may cause an accident, damage or equipment destruction.
Basic Requirements | User Safety
- Do not use the unit in areas threatened with excessive shocks, vibrations, dust, humidity, corrosive gasses and oils.
- Do not use the unit in areas where there is risk of explosions.
- Do not use the unit in areas with significant temperature variations, exposure to condensation or ice.
- The manufacturer is not responsible for any damages caused by inappropriate installation, not maintaining the proper environmental conditions and using the unit contrary to its assignment.
- If in the case of a unit malfunction there is a risk of a serious threat to the safety of people or property additional, independent systems and solutions to prevent such a threat must be used.
- The unit uses dangerous voltage that can cause a lethal accident. The unit must be switched off and disconnected from the power supply prior to starting installation of troubleshooting (in the case of malfunction).
- Do not attempt to disassemble, repair or modify the unit yourself. The unit has no user serviceable parts.
Specifications
General
Display| LED | 6 Digit | 13mm High | Red
Displayed Values| -99999 ~ 999999
RS485 Transmission| 1200…115200 bit/s, 8N1 / 8N2 | RS485
Housing Material| NORYL
Protection Class| IP65
Input Signal | Supply
Standard| Current: 4-20mA | 0-20mA | 0-5V | 0-10V
Voltage| 85 – 260V AC/DC | 16 – 35V AC, 19 – 50V DC
Output Signal | Supply
Standard| 2 x Relays (1A) | 4-20mA + 1 x Relay (1A)
Communication| RS485
Voltage| 24VDC
Passive current output | 4-20mA | (Operating Range Max. 2.8 – 24mA)
Performance
Accuracy| ±0.1% @ 25°C One Digit
Temperatures
Operating Temperature| -40 – 122°F | -40 – 50°C
- Optional
Front Panel Description
Function of Push Buttons
Symbol used in the manual : [ESC/MENU]
Functions:
- Enter to main menu ( press and hold for at least 3 seconds.)
- Exit the current Screen and Enter to the previous menu (or measure mode)
- Cancel the changes made in the parameter being edited
Symbol used in the manual : [ENTER/PAUSE]
Functions:
- Start to edit the parameter
- Enter into the sub-menu
- Confirmation of changes made in the parameter being edited
- In batch mode: Pause / Start Batching
Symbol used in the manual : [ Σ /RESET]
Functions:
- Switching of the display between total and instantaneous measurements or butcher counter (In batcher mode only)
- Zeroing the currently displayed counter (Press & Hold for at least 2 Sec), the zeroing must be confirmed by pressing the [ENTER] button
Symbol used in the manual : [ UP ] [ DOWN ]
Functions
- Change of the present menu
- Modification of the parameter value
- Switching of the display between relay thresholds and number of batches counter.
Dimensions
Wiring Diagram
Wire Connection
- Loosen Set Screw
- Insert Wire
- Tighten Set Screw
Due to possible significant interference in industrial installations, appropriate measures assuring correct operation of the unit must be applied. The unit is not equipped with an internal fuse or power supply circuit breaker. For this reason, an external time-delay cut-out fuse with a small nominal current value must be used(recommended bipolar, max. 2A) and a power supply circuit breaker located near the unit.
INSTALLATION
- 1. The unit is designed for mounting inside housings (control panel, switchboard) ensuring appropriate protection against surges and interference. Metal housings must be connected to the ground in a way that complies with the governing regulations.
- Disconnect the power supply before starting assembly.
- Check the connections are wired correctly before switching the unit on.
To install the unit, a 90.5 x 43 mm mounting hole (Figure A, B) must be prepared. The thickness of the material of which the panel is made must not exceed 5mm. When preparing the mounting hole take the grooves for catches located on both sides of the housing into consideration (Figure A, B). Place the unit in the mounting hole inserting it from the front side of the panel, and then fix it using the brackets (Figure C). The minimum distances between the center points of multiple units, due to the thermal and mechanical conditions of operation are 115 mm x 67mm (Figure D).
Terminal Descriptions
Power Supply & Relay Connection
Note: Contacts of relay outputs are not equipped with spark suppressors. When using the relay outputs for switching inductive loads (coils, contactors, power relays, electromagnets, motors, etc.) it is required to use additional suppression circuit (typically capacitor 47nF/ min. 250VAC in series with 100R/5W resistor), connected in parallel to relay terminals or (better) directly on the load.
Suppression Circuit Connection
OC-Type Output Connection
Flow Meter Connections
TKM Series : 4-20mA Output
450 Terminal| Wire Color| Description
5| Brown| +VDC
6| Blue| -VDC
33| Yellow| mA+
34| Grey| mA-
TKS Series : Pulse Output
GPM/Pulse = K factor
450 Terminal| Wire Color| Description
5| Brown| +VDC
6| Blue| -VDC
31| Black| NPN Pulse
Note: Jump 5 & 35
TKW Series : Pulse Output
GPM/Pulse = K factor
450 Terminal| Wire Color| Description
5| Brown| +VDC
6| Blue| -VDC
31| Black| Pulse
Note: Jump 5 & 35
TKW Series : 4-20mA Output
450 Terminal| Wire Color| Description
5| Brown| +VDC
6| Blue| -VDC
33| Black| mA+
34| White| mA-
TKM | TKP Series: Pulse Output
GPM/Pulse = K factor
450 Terminal| Wire Color| Description
5| Brown| +VDC
6| Blue| -VDC
31| Black| Pulse
Note: Jump 5 & 35
TIW Series: Pulse Output
GPM/Pulse = K factor
450 Terminal| Wire Color| Description
5| Brown| +VDC
6| Blue| -VDC
31| White| Pulse
Note: Jump 5 & 35
TIM | TIP Series: Pulse Output
GPM/Pulse = K factor
450 Terminal| Wire Color| Description
5| Brown| +VDC
6| Blue| -VDC
31| White| Pulse
Note: Jump 5 & 35
TIM Series: 4-20mA Output
450 Terminal| Wire Color| Description
5| Brown| +VDC
6| Blue| -VDC
33| Yellow| mA+
34| Grey| mA-
UF 1000 | 4000 | 5000 – Pulse Output
GPM/Pulse = K factor
450 Terminal| Pin| Description
5| 1| +VDC
31| 2| Pulse
6| 3| -VDC
Note: Jump 5 & 35
UF 1000 | 4000 | 5000 – 4-20mA Output
450 Terminal| Pin| Description
5| 1| +VDC
33| 2| +mA
6| 3| -VDC
Note: Jump 6 & 35
ProPulse (Flying Lead) – Pulse Output
GPM/Pulse = K factor
450 Terminal| Wire Color| Description
5| Red| +VDC
6| Shield| -VDC
31| Blue| Pulse
Note: Jump 5 & 35
ProPulse ® 2 – Pulse Output
450 Terminal| Wire Color| Description
5| Brown| +VDC
6| Blue| -VDC
31| Black| Pulse
Note: Jump 5 & 35
Programming K Factor
Programming Relays
Programming Batching
Programming Output (For 4-20mA Output Models)
Resetting Batch
Resetting Totalizer
Setting Decimal Point
Warranty, Returns, and Limitations
Warranty
Icon Process Controls Ltd warrants to the original purchaser of its products
that such products will be free from defects in material and workmanship under
normal use and service in accordance with instructions furnished by Icon
Process Controls Ltd for a period of one year from the date of sale of such
products. Icon Process Controls Ltd obligation under this warranty is solely
and exclusively limited to the repair or replacement, at Icon Process Controls
Ltd’s option, of the products or components, which Icon Process Controls Ltd
examination determines to its satisfaction to be defective in material or
workmanship within the warranty period. Icon Process Controls Ltd must be
notified pursuant to the instructions below of any claim under this warranty
within thirty (30) days of any claimed lack of conformity of the product. Any
product repaired under this warranty will be warranted only for the remainder
of the original warranty period. Any product provided as a replacement under
this warranty will be warranted for the one year from the date of replacement.
Returns
Products cannot be returned to Icon Process Controls Ltd without prior
authorization. To return a product that is thought to be defective, go to
www.iconprocon.com, and submit a customer return
(MRA) request form and follow the instructions therein. All warranty and non-
warranty product returns to Icon Process Controls Ltd must be shipped prepaid
and insured. Icon Process Controls Ltd will not be responsible for any
products lost or damaged in shipment.
Limitations
This warranty does not apply to products that: 1) are beyond the warranty
period or are products for which the original purchaser does not follow the
warranty procedures outlined above; 2) have been subjected to electrical,
mechanical, or chemical damage due to improper, accidental or negligent use;
3) have been modified or altered; 4) anyone other than service personnel
authorized by Icon Process Controls Ltd has attempted to repair; 5) have been
involved in accidents or natural disasters; or 6) are damaged during return
shipment to Icon Process Controls Ltd reserves the right to unilaterally waive
this warranty and dispose of any product returned to Icon Process Controls Ltd
where: 1) there is evidence of potentially hazardous material present with the
product; or 2) the product has remained unclaimed at Icon Process Controls Ltd
for more than 30 days afternoon Process Controls Ltd has dutifully requested
disposition. This warranty contains the sole express warranty made by Icon
Process Controls Ltd in connection with its products. ALL IMPLIED WARRANTIES,
INCLUDING WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE, ARE EXPRESSLY DISCLAIMED. The remedies of repair or
replacement as stated above are the exclusive remedies for the breach of this
warranty. IN NO EVENT SHALL Icon Process Controls Ltd BE LIABLE FOR ANY
INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND INCLUDING PERSONAL OR REAL
PROPERTY OR FOR INJURY TO ANY PERSON. THIS WARRANTY CONSTITUTES THE FINAL,
COMPLETE, AND EXCLUSIVE STATEMENT OF WARRANTY TERMS AND NO PERSON IS
AUTHORIZED TO MAKE ANY OTHER WARRANTIES OR REPRESENTATIONS ON BEHALF OF Icon
Process Controls Ltd. This warranty will be interpreted under the laws of the
province of Ontario, Canada. If any portion of this warranty is held to be
invalid or unenforceable for any reason, such finding will not invalidate any
other provision of this warranty. For additional product documentation and
technical support visit:
- www.iconprocon.com
- e-mail: sales@iconprocon.com or support@iconprocon.com
- Ph: 905.469.9283
- Icon Process Controls Ltd.
Read User Manual Online (PDF format)