KICHLER 52681CPZ Velestino Linear Chandelier Ceiling Light Instruction Manual

September 11, 2024
KICHLER

KICHLER 52681CPZ Velestino Linear Chandelier Ceiling Light

Product Usage Instructions

Refer to the fixture diagram to identify the different parts of the product for installation.

  • Pass fixture wires through the coupling, short threaded tubes, and stems. Secure stems together using short threaded tubes.
  • Pass fixture wires through the swivel and into the canopy. Secure the swivel into the last stem according to ceiling direction.
  • Cut fixture wires at least 20 inches from the canopy edge.
  • Attach the mounting strap to the outlet box using strap mounting screws. Adjust the mounting strap position as needed.
  • Attach the inspection cable to prevent wire damage during wiring.
  • Follow grounding instructions provided based on the type of fixture mounting strap.
  • Make wire connections according to the reference chart provided.
  • Raise the canopy to the ceiling, passing mounting screws through the holes in the canopy.

FAQ

  • Q: What should I do if I encounter difficulties during installation?
  • A: If you face challenges during installation, contact our customer support at 866-558-5706 for assistance during business hours (M-F 9am to 5pm EST).
  • Q: How do I ensure proper wire connections?
  • A: Refer to the wire connection chart provided in the manual to correctly match and connect the supply wires.

FIXTURE DIAGRAM

KICHLER-52681CPZ-Velestino-Linear-Chandelier-Ceiling-Light-
fig-1

PARTS LIST

  • [A] Outlet Box (Not Supplied)
  • [B] Strap Mounting Screw (2)
  • [C] Mounting Strap
  • [D] Mounting Screw (2)
  • [E] Inspection Cable (attached to Canopy)
  • [F] Knob (2)
  • [G] Canopy
  • [H] Swivel (Attached to Canopy)
  • [I] Stems (2-12”, 2-6” with Short Threaded Tubes [J] installed)
  • [J] Short Threaded Tubes
  • [K] Coupling
  • [L] Upper Tier
  • [M] Lower Tier
  • [N] Thumbscrew (16)
  • [O] Plastic Washer (16)
  • [P] Glass Shade (8)
  • [Q] Socket (4)
  • [R] Lock Washer (2)

CAUTIONS

CAUTION – RISK OF SHOCK:
Disconnect Power at the main circuit breaker panel or main fusebox before starting and during the installation.

WARNING:
This fixture is intended for installation by the National Electrical Code (NEC) and all local code specifications. If you are not familiar with code requirements, installation by a certified electrician is recommended. Failure to adhere to these codes and instructions may result in serious injury and/or property damage and will void the warranty.

CLEANING:

  • Always be certain that electric current is turned off before cleaning.
  • Only a soft damp cloth should be used. Harsh cleaning products may damage the finish.

INSTALLATION INSTRUCTIONS

NOTE: Thread locking compound must be applied to threads as noted with (4) symbol to prevent accidental rotation of fixture during cleaning, relamping, etc.

  1. Pass fixture wires from coupling[K] through the desired number of short threaded tubes[J] and stems[I]. Screw stems together using short threaded tubes.
    Screw the first step into the coupling.
    NOTE: A minimum of one (1) 12-inch stem must be used when mounting the fixture.

  2. Pass fixture wires from the last stem through the end of the swivel[H] and into the canopy[G]. Thread the end of the swivel into the end of the last stem. Note the direction of the swivel by the ceiling.

  3. Cut fixture wires a MINIMUM of 20 inches from the top edge of canopy.

  4. Find the appropriate threaded holes on mounting strap[C] that align with hole distance in canopy. Assemble mounting screws[D] into threaded holes starting from the outlet box side.

  5. Attach mounting strap to outlet box[A] using the supplied strap mounting screws[B]. Mounting strap can be adjusted to suit position of fixture.

  6. Attach the inspection cable[E] to the mounting strap or to the inside of the outlet box and secure into place to prevent damage to the wires during wiring.

  7. Grounding instructions: (See Illus. a or b).

    • On fixtures where mounting strap is provided with a hole and two raised dimples, wrap ground wire from outlet box around green ground screw, and thread into hole.
    • On fixtures where a cupped washer is provided, attach ground wire from outlet box under cupped washer and green ground screw, and thread into mounting strap.
    • If fixture is provided with ground wire, connect fixture ground wire to outlet box ground wire with wire connector after following the above steps. Never connect ground wire to black or white power supply wires.KICHLER-52681CPZ-Velestino-Linear-Chandelier-Ceiling-Light-fig-2
  8. Make wire connections. Reference chart below for correct connections and wire accordingly.
    Connect Black or Red Supply Wire to:| Connect White Supply Wire to:
    ---|---
    Black| White
    Parallel cord (round & smooth)| Parallel cord (square & ridged)
    Clear, Brown, Gold or Black without Tracer| Clear, Brown, Gold or Black with Tracer
    Insulated wire (other than green) with copper conductor| Insulated wire (other than green) with silver conductor
    *Note: When parallel wire (SPT 1 & SPT 2) is used. The neutral wire is square shaped or ridged and the other wire will be round in shape or smooth (See illus.)|

Neutral Wire

  1. Raise canopy to ceiling, carefully passing mounting screws through mounting screw holes in canopy.
    NOTE: Be certain wires do not get pinched between mounting strap and canopy or canopy and ceiling.

  2. While holding canopy in place, use lock washers[R] and knobs[F] to secure canopy. Tighten to secure.

  3. While holding the upper tier[L] of fixture arms in place (NOTE: Hold on to the center hub of the upper tier), rotate the lower tier[M] of fixture arms into desired position as shown below (NOTE: Rotate the center hub of the lower tier). See Fig. 2:KICHLER-52681CPZ-Velestino-Linear-Chandelier-Ceiling-Light-fig-4

  4. Slip one (1) plastic washer[O] onto the threads of a thumbscrew[N]. Repeat with a second thumbscrew and plastic washer.
    Align the holes in glass shade[P] with two (2) of the threaded holes on socket[Q].
    NOTE: Make sure the threaded holes on socket are flush against the inside surface of glass shade.
    While holding glass shade in place, screw thumbscrews (with plastic washers installed) into the aligned holes to secure glass shade to socket. DO NOT OVER-TIGHTEN.
    NOTE: Make sure the end of the glass shade that has the installation holes in it is the end that is pointing toward the center of the fixture (as shown in “Fig. 1: GLASS SHADE INSTALLATION”).

  5. Repeat Step 12 for remaining glass shades.

  6. Insert recommended bulb(s). (Not supplied).

© 2024 Kichler Lighting LLC. All rights reserved. For warranty information please visit: kichler.com/warranty. We’re here to help at 866-558-5706 Hrs: M-F 9 am to 5 pm EST.