POWEROPTIMAL Elon 100 PV Water Heating System Owner’s Manual
- September 9, 2024
- PowerOptimal
Table of Contents
POWEROPTIMAL Elon 100 PV Water Heating System
Product Specifications:
Unit no.| | Development name| | Elon® serial no.|
---|---|---|---|---|---
Date| | Name: 1 st level **support person|
Unit construction status (Works OR Final Completion)| | Resident
name|
Reported issue (customer)|
Reported issue (Level 1 Support)**|
Product Usage Instructions
Confirming Correct Voltages and Currents:
- Confirm correct voltages and currents of all connections through the following steps:
- Check V DC (open) and V DC (closed).
- Ensure the controller wire is connected properly with appropriate LEDs indicating activity.
- Verify DC voltage to the element with solar power switched on.
- Check active current through the element with a DC clamp meter.
- Confirm AC voltage to the element with mains power switched on.
- Measure active current through the element with an AC clamp meter.
Troubleshooting Steps:
- Set thermostat back to the original setting.
- Write down the conclusion from your testing and any observations.
Things to Remember:
- If there is no continuity, replace the element adapter due to a blown thermal fuse.
- To switch on solar power to the element, ensure enough solar energy, and set the controller dial to SOLAR ONLY.
- To switch on mains power to the element, turn the control dial to MAINS ONLY.
- Ruling out a partial short of the element to earth by disconnecting both wires and observing LED behavior.
Mains & Solar Indicator Lights (LEDs):
- Green light ON: Geyser on temperature
- Green light flashing: Heating with solar
- Red light ON: Isolation fault (contact electrician)
- Red light flashing: No power to unit or supply voltage outside specifications
Control Dial Settings:
Dial Setting | Time on Mains* | Time on Solar* |
---|---|---|
MAINS ONLY | 24 hr (Never) | 12:00 – 08:00 |
08:00 – 12:00 |
Frequently Asked Questions (FAQ):
-
Q: How do I know if the thermal fuse on the element adapter has blown?
A: Check continuity on the element adapter thermostat female terminals. If there is no continuity, the thermal fuse has blown, and you need to replace the element adapter. -
Q: How do I switch on solar power to the element?
A: Ensure there is enough solar energy, check at solar terminals, and set the controller dial to SOLAR ONLY. Solar power will be routed to the element within 15 seconds after the thermostat closes.
NOTE: This Troubleshooting Guide is intended for electricians and not general users. Users should please refer to the User Manual, which can be found at www.poweroptimal.com/manuals. Please see page 3 for a summary of the Elon®’s controller and LED lights.
Troubleshooting Steps
- If you have a test controller (little black box with the control dial & lights), plug it into the Elon®.
- If you identify the problem at a specific step, you can stop there and write your conclusion.
- If you replace an Elon®, thermostat, element or wiring, you should commission the system again as per the Installation Manual.
No. | Action | Result | Units |
---|---|---|---|
1 | Confirm correct wiring and polarity to Elon®. Also confirm test meter wires | ||
are connected correctly, black to common! | |||
2 | Confirm correct voltages and currents of all connections through the |
following steps:
2a| Confirm open / closed thermostat voltages (11 – 14 V DC open, 0 V DC
closed).| | V DC (open)
| V DC (closed)
2b| Confirm controller wire is connected properly. The connections should
“click” into place and appropriate LEDs should indicate (be active).| |
2c| With solar power to element switched on (green LED flashing), confirm
same DC voltage to element as measured at solar terminals.| | V DC solar
| V DC element
2d| With DC clamp meter confirm that there is an active current through
element.| | A DC
2e| With mains power to element switched on (red LED flashing), confirm
same AC voltage to element as measured at mains terminals (should be
approx. 230V AC).| | V AC mains
| V AC element
2f| With AC clamp meter confirm active current through element of
between 9 and 18 Amps depending on element rating.| | A AC
3| If you used a test controller for troubleshooting, remember to plug the
wire from the installed controller back into the Elon® and check functioning.|
|
4| Set thermostat back to original setting.| |
5| Write down the conclusion from your testing ( What caused the reported
issue? ) & any other observations:
Things to Remember
- The red mains LED will only start functioning once stable mains voltage between 190 and 260 V AC is present for more than 5 minutes. (In other words, the Elon® will only allow mains power to the element 5 minutes after mains connection or switch-on.)
- Solar power is only recognised 40 seconds after active solar panels are connected to Elon®.
- An open thermostat (water at correct temperature) measures between 11 and 14 V DC across the “thermostat” terminals on the Elon®. Polarity across these terminals is not important.
- A closed thermostat (cold water) measures 0 V across the “thermostat” terminals on the Elon®.
- If the thermostat measures between 11 and 14 V DC in the closed state, either the thermostat is faulty OR the thermal fuse on the element adapter might have blown. Check continuity on the element adapter thermostat female terminals. If there is no continuity, the thermal fuse has blown and you need to replace the element adapter.
- How to switch on solar power to element: With enough solar energy (check at solar terminals), solar power will be routed to the element within 15 seconds after the thermostat closes and the controller dial is set to “SOLAR ONLY”. A green flashing LED indicates this condition.
- How to switch on mains power to element: Turn control dial to “MAINS ONLY” and, if the thermostat is closed, mains power will be directed to the element indicated by a red flashing LED.
- Note: Once the dial has been turned to “MAINS ONLY”, it will complete a full mains heating cycle (until the thermostat opens). Turning the control back to “SOLAR ONLY” at this point will not immediately switch the unit back to solar power. It will only switch back again after the mains heating cycle is completed (i.e. the thermostat opens) and the thermostat then closes again. You can finish the mains heating cycle faster by reducing the thermostat temperature setting until the thermostat opens. Test solar power first.
- Fast flashing red / green LEDs indicate either:
- a short between a PV (photovoltaic) lead and earth – this condition prevents solar power to the element;
- a partial short of the element to earth, e.g., a puncture exposing element to water. This condition can be ruled out by disconnecting both wires to the element. If the LEDs stop flashing, the element is faulty. If the LEDs continue flashing, then the cause is likely as per item a. above.
The Mains & Solar indicator lights (LEDs) indicate the following conditions:
The control dial sets the mains & solar times as follows:
- Times are approximate – will vary slightly with season and location