SANUS SA-IWB9-W1 9-Inch TV Media In-Wall Box Instruction Manual

September 3, 2022
SANUS

SANUS SA-IWB9-W1 9-Inch TV Media In-Wall Box

  • Please read these instructions completely before you begin.

IMPORTANT SAFETY INSTRUCTIONS

  1. Do not use this product near water; such as a bath tub, wash bowl, kitchen sink, laundry tub, swimming pool, or in a wet basement.
  2. Never push objects of any kind into this product through openings, as they may touch dangerous voltages. Never touch uninsulated telephone wires or terminals, unless the telephone line has been disconnected at the network interface.
  3. Never install communications wiring, or components, during a lightning storm.
  4. Equipment shall be installed in accordance with ANSI/NFPA 70, National Electrical Code (NEC), NFPA 72, CAN-ULC-S540, Canadian Electrical Code, and/or other applicable sections of ANSI/IEEE C2 & National Electrical Safety Code (NESC). Equipment intended for installation in information technology equipment (computer) rooms should be installed in accordance with NFPA 75, Standard for the Fire Protection of Information Technology Equipment.
  5. Power supplied to components must be provided by UL Listed Class 2 power limited power supply.
  6. All power limited and non-power limited wiring must be separated by a minimum of ¼” spacing.
  7. Installation shall be completed by a professional electrical contractor or low voltage technician.
  8. Maximum load carrying capacity of 30 lb.

Dimensions

9” BOX
17” BOX

Product Contents

9” BOX


**17” BOX

**


Recommended Tools
Enclosure Physical Installation

Locate enclosure indoors in a low humidity, climate controlled (0°C / 32°F – 49°C / 120°F) area within close proximity to power source. Remove cable knockouts as needed. When required, 2” rubber grommets (AC1034) are available to seal and protect openings. If mounting behind a TV, ensure box is positioned to be concealed from view by the display

RETROFIT Installation

Wall Prep

After desired height is identified, use a stud finder to locate the vertical stud locations. Place the cutting template against the wall surface and trace the outline. Use a drywall saw to cut the box outline.

Trim Ring Installation

Use the included four (4) screws to affix the trim ring to the corresponding holes located in the enclosure frame.
⚠ CAUTION: DO NOT overtighten the screws.

Enclosure Installation

Insert the enclosure into the wall opening and utilize a Philips head screwdriver to engage the four (4) drywall clips in all corners. If near wall studs, you can also utilize drywall screws to secure box from the inside. Once installed in the wall – install the two (2) side screws to secure sides of the trim to the enclosure.

NEW CONSTRUCTION Installation

Surface Mount

Mount to a plywood backboard using the pre-drilled mounting holes on the rear of the enclosure. The use of a level is recommended for correct installation of the enclosure.

Flush Mount

The Enclosure is designed to fit between a minimum 2×4 studded wall at 16”on- center (OC). If wall studs are greater than 16” on-center (OC) refer to Retrofit Installation. Position Enclosure between wall studs at appropriate depth (refer to drywall depth guide on enclosure ) and utilize four (4) drywall screws to secure to wall studs.

Trim Ring Installation

After drywall is installed, use the included six (6) or four (4) screws to affix the trim ring to the corresponding holes located in the enclosure frame.
⚠ CAUTION: DO NOT overtighten the screws.

Power Installation

Running Power to the Installation

Remove desired outlet knockout. Install a single-gang metal outlet box. Connect 15 amp, 120 volt power receptacle to power cable with approved wiring method to local codes.

NOTE: Legrand offers both non-surge protected (P/N   F7526) and surge protected (364569-02-V1) outlet kits. Only install standard size wall plates as oversized plates will not fit.

Equipment Mounting Inside Enclosure

5IN Elevated Mounting Bracket [OPTIONAL]

The removable component mounting bracket allows organization of devices before or after installation. If desired the bracket includes four (4) plunger / grommets to secure directly to back wall of enclosure – Vertical or Horizontal.

Built-in Lacing Tabs

The back wall has assorted lacing tabs for securing large equipment directly to enclosure. The lacing tabs have a protective cover that can be removed by utilizing screwdriver and pushing protective cover into opening to provide unobstructed guide for hook and loop strapping.

Cover Installation

Install the Cover

To attach the cover, position cables exiting enclosure towards the pass- through opening and slide bottom tabs into receiving channels of trim ring. Push the sides of the cover into the locking side channels for a flush finish. The 17” model has two covers for easy access to contents, even when the enclosure is partially obstructed.

**Thank you for choosing SANUS!**
Please take a moment to let us know how we did:

| Call us at: 1-800-359-5520| | [email protected]
---|---|---|---
| Or , chat at: SANUS.com/chatSP| | SANUS.com

Legrand AV Inc. and its affiliated corporations and subsidiaries (collectively, “Legrand”), intend to make this manual accurate and complete. However, Legrand makes no claim that the information contained herein covers all details, conditions, or variations. Nor does it provide for every possible contingency in connection with the installation or use of this product. The information contained in this document is subject to change without notice or obligation of any kind. Legrand makes no representation of warranty, expressed or implied, regarding the information contained herein. Legrand assumes no responsibility for accuracy, completeness or sufficiency of the information contained in this documen

©2021 Legrand AV Inc. All rights reserved. SANUS is a brand of Legrand. SANUS and the SANUS logo are registered trademarks. All other brand names or marks are used for identification purposes and are trademarks of their respective owners.

5 inch Universal Mounting Plate

Catalog Number(s)

USE THIS CUTTING TEMPLATE FOR WALL PREP IN RETROFIT INSTALLATIONS

After desired height is identified, use a stud finder to locate the vertical stud locations. Place this cutting template against the wall surface and trace the outline. Use a drywall saw to cut the box outline.

Model SA-IWB9-W1 Wall Plate Template
6700-301796<00>

©2021 Legrand AV Inc. All Rights Reserved. SANUS is a brand of Legrand. SANUS and the SANUS logo are registered trademarks of Legrand.

Documents / Resources

| SANUS SA-IWB9-W1 9-Inch TV Media In-Wall Box [pdf] Instruction Manual
SA-IWB9-W1, 9-Inch TV Media In-Wall Box, SA-IWB9-W1 9-Inch TV Media In-Wall Box
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

SANUS User Manuals

Related Manuals