KLARSTEIN 10034682 Air Conditioner Instruction Manual

June 5, 2024
Klarstein

KLARSTEIN 10034682 Air Conditioner

Dear Customer,
Congratulations on purchasing this device. Please read the following instructions carefully and follow them to prevent possible damages. We assume no liability for damage caused by disregard of the instructions or improper use. Scan the QR code to get access to the latest user manual and more product information.

TECHNICAL DATA

Item Number 10034682
Power supply 230 V~ 4.1 A / 50Hz

SAFETY INSTRUCTIONS

  •  The air conditioner is only suitable for indoor use and not for other applications.
  •  Follow the local mains connection regulations when installing the air conditioner. Make sure it is properly grounded. If you have questions about the electrical installation, follow the manufacturer’s instructions. Hire a trained electrician if necessary.
  •  Make sure that the power plug is intact and firmly plugged in after the air conditioner is installed. Install the power cord properly to prevent someone from stumbling over or accidentally pulling out the plug.
  •  Do not place objects in the air inlet or outlet. Keep the air inlet opening free of objects.
  •  If the drain lines are installed, make sure that the lines are connected properly and are not twisted or kinked.
  •  While adjusting the upper and lower air vents of the air outlet, gently pull them with your hands to prevent damage.
  •  Make sure the unit is upright when moving it.
  •  Do not disassemble the device. Do not modify or adjust the device on your own, otherwise it may malfunction or even damage people and property. Contact the manufacturer or service personnel for a repair to prevent any dangers of malfunction.
  •  Do not pull the plug out to turn off the power.
  •  To prevent spillage of water or other liquids on the unit, do not place cups or other objects on the case .
  •  Do not use insect sprays or flammable substances near the air conditioner.
  •  Do not clean the device with chemical solvents such as gasoline or alcohol. When cleaning the air conditioner, disconnect the power cord. Clean the device with a damp soft cloth. If the unit is heavily contaminated, rub it with a mild detergent.
  •  The air conditioner may be used by children 8 years and older and persons with physical or mental disability or limited perception if they have been instructed in the safe use of the device and have understood the hazards involved.
  •  Children must not play with the device.
  •  Cleaning and maintenance must not be carried out by children without supervision.

Instructions on location

  •  Place the unit in a shallow, dry place. Keep a distance of more than 50 cm between the unit and surrounding objects and the wall.
  •  Keep the unit away from fuel, flammable gases, stoves and other sources of heat.
  •  Do not place the unit in a bathroom or other humid environment.

DEVICE DESCRIPTION

Top Cover

Swing leaf
Caster
Rear housing

Front housing
Mask

Remote control

Handle
Continuous drainage hole
Air inlet grill
Power cord (1,80 m)
Water outlet
CON filter screen

Air vent
Power cord hook
EVA filter
Rear housing

1 Exhaust pipe assembly
2 Window sealing plate assembly

Remote control

INSTALLATION

Note: SIn the moving process, ensure that the air conditioning is in the upright position and the air conditioning should be placed on a fl at surface. Do not install and use the air conditioning in the bathroom or other humid environments.

Install the window sealing plate assembly

  1.  Half open the window, and mount the window sealing plate assembly to the window. The assembly can be placed in horizontal and vertical direction.
  2.  Pull various components of the window sealing plate assembly open, adjust their opening distance to bring both ends of the assembly into contact with the window frame, and fi x various components of the assembly.

Install the heat pipe assembly

  1.  Screw the heat pipe assembly (exhaust fi tting end) into the exhaust port on the rear panel (counterclockwise).
  2.  Connect the heat pipe to the window sealing plate.

Install the body

  1.  Move the machine with installed heat pipe and fi ttings before the window, and the distance between the body and walls or other objects shall be least 50 cm.
  2.  Elongate the heat pipe and snap the fl at end of the heat pipe joints into the elliptical hole the window sealing plate assembly.
  3.  The fl at end of the heat pipe joints must be snapped into place.
  4.  The pipe cannot be distorted nor has substantial turning (greater than 45 °). Keep the ventilation of the heat pipe unobstructed.The length of the exhaust hose shall be 280~1,500 mm, and this length is based on the specifi cations of the air conditioning. Do not use extension tubes or replace it with other different hoses, or this may cause a malfunction. Exhaust must be unobstructed; otherwise it may cause overheating.

USE AND OPERATION

1 Remote control reception window
2 Power key

Press the key to turn on and turn off the machine. In the case of power on, press the key to turn off the machine; in the case of power off, press the key to turn on the machine.

3| Modus

In the case of power on, press the key to switch between cool- ing ® air supply ® dehumidification ® cooling ® … mode.

4| Down key

Press the Up and Down keys to change the set temperature or timing sett value, operate as follows:

While setting temperature, press up key or down key to select the required

temperature (not available in air supply or dehumidification mode). Pressing the up and down key simultaneously switches the display of the temperature between degrees Celsius of Fahrenheit.

5| Display
6| Up key

Press the Up and Down keys to change the set tempera- ture or timing sett value, operate as follows:

While setting temperature, press up key or down key to select the required

temperature (not available in air supply or dehumidification mode).

Pressing the up and down key simultaneously switches the dis- play of the temperature between degrees Celsius of Fahrenheit.

7| Wind speed selection key

In cooling and air supply mode, press the key to select high, medium or low wind speed operation.

In dehumidification mode, pressing the key is invalid, and the fan will

forcibly choose low wind speed operation.

---|---
8| Timing Key

In the case of power on, press the key to close timing; in the case of power

off, press the key to open timing.

Press the key, when the timing symbol flashes, press up and down key to

select the required timing value.

Timing values can be set within 1-24 hours and the timing value is adjusted

upwards or downwards by one hour.

Operation instructions of the remote control

POWER Press the key to turn on or turn off the machine.
MODE Press the key to switch between cooling, air supply, and

dehumidification mode.

UP| Press the key to increase temperature and timing set value.
DOWN| Press the key to reduce temperature and timing set value.
FAN| Press the key to select high, medium and low wind speed output circularly.
TIMER| Press the key to set timing value.
SWING| Press the key to open or close swing style. Air flow of the

air outlet can blow at different angles.

°C<–>°F| Press the key to switch between Celsius and Fahrenheit.

CLEANING AND CARE

Drainage Instructions Manual drainage

  1.  When the machine stops after the water is full, turn off the machine power and unplug the power plug.
  2.  Place the water container below the side water outlet behind the body.
  3.  Unscrew the drainage cover and unplug the water plug, the water will automatically fl ow into the water container. Keep the drainage cover and the water plug properly.
  4.  During drainage, the body can be tilted slightly backwards.
  5. When the water is discharged, stuff the water plug, and tighten the drainage cover. Note: Please move the machine carefully, so as not to spill the water in the water pan at the bottom of the body. restart the machine after the water plug and drainage cover are installed, otherwise condensate water of the machine will fl ow to the fl oor or the carpet.

Continuous drainage (only applicable to cooling and dehumidifi cation mode)

  1.  Unscrew the drainage cover, and unplug the water plug.
  2.  Set the drainage pipe into the water outlet.
  3.  Connect the drainage pipe to the bucket.

DANGER
Risk of electric shock Before cleaning and maintenance, turn off the machine and unplug the plug.

Clean the surface
Clean with surface of machine with a wet soft cloth. Don‘t use chemicals, such as benzene, alcohol, gasoline, etc.; otherwise, the surface of the air conditioning will be damaged or even the whole machine will be damaged.

Clean the filter screen
If the filter screen is clogged with dust, and the effectiveness of the air conditioning is reduced, be sure to clean the filter screen once every two weeks.

Clean the upper filter screen frame
Clasp the wedging block of the EVA filter screen frame with hands. Force down from the outside to remove the EVA filter screen frame. Unscrew four screws fixing the EVA filter screen and the rear housing to remove the EVA filter screen (as shown in the above figure). Put the EVA filter screen into warm water with neutral detergent (about 40 °C / 104 °F) and dry it in the shade after rinsing clean.

Clean the lower filter screen frame
Hold the handle of the CON filter screen frame, and pull it outward gently to remove it. Put the CON filter screen into warm water with neutral detergent (about 40 °C / 104 °F) and dry it in the shade after rinsing clean.

  1. Retaining screw
  2. Wedging block
  3. Wedging block

Postseason Storage

  1.  Unscrew the drainage cover, unplug the water plug, and discharge the water in the water pan into other water containers or directly tilt the body to discharge the water into other containers.
  2.  Turn on the machine, adjust it to low-wind ventilation mode, and maintain this state until the drainage pipe becomes dry, so as to keep the inside of the body in a dry state and prevent it from mildewing.
  3.  Turn off the machine, unplug the power plug, and wrap the power cord around the wrapping post; install the water plug and the drainage cover.
  4.  Remove the exhaust pipe and keep it properly.
  5.  Cover the air conditioning with a plastic bag. Put the air conditioning in a dry place.Keep it out of the reach of children, and take dust control measures.

TROUBLESHOOTING

Problems Reasons Solutions
The air conditioning does not work. There is no electricity. Turn it on

after connecting it to a socket with electricity.
The overflow indicator

displays „FL“.

| Discharge the water inside.
The ambient temperature is too low or too high.| Recommend to use the machine in at the temperature of 7-35 ℃ (44-95 ℉).
In cooling mode, the room temperature is lower than the set temperature.| Change the set temperature.
In dehumidification mode, the

ambient temperature is low.

| The machine is placed in a room with an ambient

temperature of greater than

17 °C(62 °F).

The cooling effect is not good. There is direct sunlight. Pull the curtains.

Doors or windows are open; there are a lot of people; or in cooling mode, there are other sources of heat.| Close doors and windows, and add new air conditioning.
The filter screen is dirty.| Clean or replace the filter

screen.

The air inlet or outlet is blocked.| Clear obstructions.
Big Noise| The air conditioning is not

placed on a flat surface.

| Put the air conditioning on a flat and hard place (to reduce noise).
The compressor does not work.| Overheat protection starts.| Wait for 3 minutes until the temperature is lowered, and then restart the machine.
The remote control does not work.| The distance between the machine and the remote control is too far.| Let the remote control get close to the air conditioning, and make sure that the remote control directly faces to the direction of the remote control receiver.
The remote control is not aligned with the direction of the remote control receiver.
Batteries are dead.| Replace batteries.
Displays ‚E1‘.| The pipe temperature sensor is abnormal.| Check the pipe temperature sensor and related circuitry.
Displays ‚E2‘| The room temperature sensor is abnormal.| Check the room temperature sensor and related circuitry.

Notes on Refrigerant R290 Warning

  •  The air conditioner must be kept and transported upright. Otherwise, irreparable compressor damage may occur. Let the unit sit for at least 24 hours before using it.
  •  Switch off the device and disconnect it from the power supply before cleaning.
  •  Make sure that the product generates a constant flow of air. Make sure the air inlets and outlets are not blocked.
  •  To prevent leaks, operate this unit on a horizontal surface.
  •  Any person working on a refrigerant circuit should have a current certificate from an accredited assessment body. This ensures competence for the safe handling of refrigerants according to an industry-recognised assessment specification.
  •  If the device stops working, dispose of it properly.
  •  Store the device in a well-ventilated place when not in use.
  •  Store the device so that it is not damaged.
  •  Repairs may only be carried out by the manufacturer or an authorised specialist company.
  •  The cables connected to the device may contain potential ignition sources.
  •  Do not damage any components of the refrigerant circuit. Escaping refrigerant may not be noticed because it is odourless.
  •  Maintenance and repairs must be carried out under the supervision of specialists in the use of flammable refrigerants.

Information for rooms with refrigerant pipes

  •  Limit the piping to a minimum.
  •  Be careful not to damage the piping.
  •  Appliances with flammable refrigerants may only be installed in a well-ventilated room.
  •  Comply with national gas regulations.
  •  All mechanical connections must be freely accessible for maintenance purposes.

Information for rooms with refrigerant pipes

  •  Limit the piping to a minimum.
  •  Be careful not to damage the piping.
  •  Appliances with flammable refrigerants may only be installed in a well-ventilated room.
  •  Comply with national gas regulations.
  •  All mechanical connections must be freely accessible for maintenance purposes.

PRODUCT DATA SHEET

Information according to regulation (EU) No. 626/2011
Refrigerant (R290) leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to 3. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 3 times higher than 1 kg of CO2 , over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.Energy consumption 0,88 kWh per 60 minutes, based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.

Information according to regulation (EU) No. 206/2012

Model identifier(s) 10034682
Description Symbol
Rated capacity for cooling Prated for cooling
Rated capacity for heating Prated for heating
Rated power input for cooling PEER
Rated power input for heating PCOP
Rated Energy efficiency ratio EERd
Rated Coefficient of performance COPd
Power consumption in thermostat-off mode PTO
Power consumption in standby mode PSB

Electricity consumption of single/double

duct appliances

(indicate for cooling and heating separately)

| DD: QDD SD: QSD| 0,9| DD: kWh/a SD: kWh/h
Sound power level| L WA| 62| dB(A)
Global warming potential| GWP| 3| kgCO2 eq.
Contact details

for obtaining more information

| Chal-Tec GmbH,

Wallstraße 16, 10179 Berlin, Germany.

DISPOSAL CONSIDERATIONS

If there is a legal regulation for the disposal of electrical and electronic devices in your country, this symbol on the product or on the packaging indicates that this product must not be disposed of with household waste. Instead, it must be taken to a collection point for the recycling of electrical and electronic equipment. By disposing of it in accordance with the rules, you are protecting the environment and the health of your fellow human beings from negative consequences. For information about the recycling and disposal of this product, please contact your local authority or your household waste disposal service. This product contains batteries. If there is a legal regulation for the disposal of batteries in your country, the batteries must not be disposed of with household waste. Find out about local regulations for disposing of batteries. By disposing of them in accordance with the rules, you are protecting the environment and the health of your fellow human beings from negative consequences.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals