solaredge S500B Power Optimizer Instructions
- September 7, 2024
- solaredge
Table of Contents
solaredge S500B Power Optimizer
Specifications
- Product: SolarEdge Power Optimizers
- Approval Date: July 17, 2024
- Waiver Number: RFW-002355
- Approved Regions: Europe
- Approved Designs:
- S500B Power Optimizers:
- PV modules up to 550W
- Voc up to 125V
- Impp up to 15A
- Isc up to 16.5A
- S650B Power Optimizers:
- PV modules up to 650W
- Voc up to 85V
- Impp up to 15A
- Isc up to 16.5A
- Minimum DC/AC Oversizing Ratio: 120%
Product Usage Instructions
Installation Guidelines
Follow the SolarEdge specifications and installation documents for proper
installation of the Power Optimizers. Ensure compliance with all guidelines
provided.
Monitoring Requirement
Connect the sites to SolarEdge monitoring as it is a mandatory requirement
for approved installations.
Warranty Information
The approved designs exceeding the Power Optimizers’ maximum short circuit
current and rated DC input power will not void the warranty of the Power
Optimizer or Inverter.
FAQ
-
Q: Can I install the Power Optimizers in regions outside Europe?
A: No, the approval is limited to installations in Europe only. -
Q: What is the minimum DC/AC oversizing ratio required per inverter?
A: The minimum ratio required is 120% according to the specified guidelines. -
Q: Is connecting sites to SolarEdge monitoring mandatory?
A: Yes, it is mandatory for all approved installations to connect to SolarEdge monitoring.
SolarEdge Product Waiver Approval
Issue date: July 17, 2024
Dear installer,
Upon examining your waiver request, SolarEdge decided to approve it under the
following conditions:
- This approval is limited to installations done in Europe only.
- The approved designs are as follows:
- The connection of S500B Power Optimizers with PV modules up to 550W, Voc up to 125V, Impp up to 15A and Isc up to 16.5A.
- The connection of S650B Power Optimizers with PV modules up to 650W, Voc up to 85V, Impp up to 15A and Isc up to 16.5A.
- The minimum DC/AC oversizing ratio per inverter shall be at least 120% :
- For datasheet-based designs, it is according to STC values (disregarding bi-facial gains).
- For SolarEdge Designer based designs, it is according to the max achieved DC power.
- The rest of the installation guidelines and the Power Optimizer’s performance remain as stated in the SolarEdge specifications and installation documents.
SolarEdge approves that the designs mentioned above, though exceeding the
Power Optimizers maximum short circuit current (Isc) of connected PV module
(16.5A vs. 15A) and the rated DC input power (550W vs. 500W), will not void
the Power Optimizer or Inverter warranty.
The sites must be connected to the SolarEdge monitoring.
Ido Ginodi
Chief Product Officer