solaredge SE3000H Single Phase Energy Hub Inverter Instruction Manual

June 12, 2024
solaredge

solaredge SE3000H Single Phase Energy Hub Inverter

solaredge SE3000H Single Phase Energy Hub Inverter

Optimised battery storage with HD-Wave technology

  • Single string design for inverters up to 5kW AC
  • Record-breaking 99% weighted efficiency with 200% DC oversizing, for higher energy yield
  • Modular design, future ready with optional upgrades enabling:
    • Full home backup power
    • High efficiency DC-coupled storage
    • Backup generator connection
    • EV charging, with SolarEdge Smart EV Charger
  • Built-in consumption monitoring
  • Multi-inverter, scalable storage solution
  • Advanced safety features including SafeDC™, rapid shutdown, and integrated arc fault protection
  • Built-in panel-level monitoring
  • Rapid inverter commissioning via smartphone using SetApp
  • Small, lightweight, and easy to install
  • IP65-rated, for indoor and outdoor installations

OUTPUT – AC ON GRID

Rated AC Power| 3000| 4000| 5000| 6000| 8250| 10000| VA
Maximum AC Power Output| 3000| 4000| 5000| 6000| 8250| 10000| VA
AC Output Voltage (Nominal)| 220 / 230| Vac
AC Output Voltage Range| 184 – 264.5| Vac
AC Frequency Range (nominal)| 50/60 ± 5| Hz
Maximum Continuous Output Current| 14| 18.5| 23| 27.5| 37.5| 45.5| A
Total Harmonic Distortion (THD)| <3| %
Power Factor| 1, adjustable -0.8 to 0.8|
Utility Monitoring, Islanding Protection, Country Configurable Thresholds| Yes|
Charge Battery from AC (if allowed)| Yes|
Typical Nighttime Power Consumption| <2.5| W
OUTPUT – AC BACKUP ( 2 )
Rated AC Power in Backup Operation(3)| 3000| 4000| 5000| 6000| 7400| 9000| W
AC Output Voltage (Nominal)| 220 / 230| Vac
AC Output Voltage Range| 184-264.5| Vac
AC Frequency| 50/60 ± 5| Hz
Maximum Continuous Output Current in Backup Operation(4)| 14| 18.5| 23| 27.5| 34| 41.5| A
INPUT – DC (PV AND BATTERY)
Transformer-less, Ungrounded| Yes|
Max Input Voltage| 480| Vdc
Nom DC Input Voltage| 380| 400| Vdc
Reverse-Polarity Protection| Yes|
Ground-Fault Isolation Detection| 600kΩ Sensitivity|
Maximum DC PV Power| 6000| 8000| 10000| 12000| 16500| 20000| W
Maximum Input Current(5)| 8.5| 11| 14| 16.5| 22.5| 25.5| Adc
Maximum Inverter Efficiency| 99.2| %
European Weighted Efficiency| 98.8| 99| %
2-pole Disconnection| Yes|
BATTERY STORAGE
Supported Battery Types| SolarEdge Energy Bank Battery, LG RESU10H Prime, LG RESU16H Prime|
Number of Batteries per Inverter| Up to 3 SolarEdge Energy Bank Batteries or up to 2 LG Prime batteries(6)|
Continuous Power| Up to inverter rated power|
SMART ENERGY CAPABILITIES
Consumption Metering| Built-in(7)|
Battery Storage| In backup: Up to 3 inverters, 88.2kWh with SolarEdge Energy Bank Battery|
EV Charging| Smart EV ready – separate EV charger and cabling required|

  1. These specifications apply to inverters with part numbers SExxxxH-AUS3xxxxx and connection unit model number DCD-1PH AU-PxH-F-x
  2. Not designed for standalone applications and requires AC for commissioning
  3. Rated AC power in Backup Operation are valid for installations with multiple inverters. For a single backup inverter operation, rated AC power in backup is 90% of the stated value
  4. Rated current in backup operation are valid for installations with multiple inverters. For a single backup inverter operation, rated current in backup is 90% of the stated value
  5. A higher current source may be used; the inverter will limit its input current to the values stated
  6. Support for 2 LG Prime batteries with compatible inverter firmware
  7. For consumption metering current transformers should be ordered separately: SE-CTML-0350-070 or SE-ACT-0750-100 or SE-ACT-0750-250

ADDITIONAL FEATURES

Supported Communication Interfaces| RS485 – Modbus devices, RS485 – SE protocol, Ethernet, Wi-Fi, EnergyNet|
Integrated AC, DC and Communication Connection Unit| Yes|
Inverter Commissioning| With the SetApp mobile application using built-in Wi- Fi Access Point for local connection|
STANDARD COMPLIANCE
Safety| IEC-62103 (EN50178), IEC-62109, AS/NZS3100|
Grid Connection Standards| AS/NSZ 4777.2:2020, EN 50549-1|
Emissions| IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12|
Listing| Photovoltaic Inverter| SExxxxxH|
Battery Inverter| SExxxxxK-B|
Photovoltaic and Battery Inverter| SExxxxxK-BPV|
Multiple Mode Inverter (Battery only)| SExxxxxK-MMB|
Multiple Mode Inverter| SExxxxxK-MM|
INSTALLATION SPECIFICATIONS
AC Output and DC Input Conduit Size / Wire Cross Section| 32 mm Maximum / 1-10 mm2|
Dimensions with Connection Unit (H x W x D)| 450 x 370 x 174| 540 x 370 x 185|
Weight with Connection Unit| <15| <20|
Communication Glands| 2| kg
Noise| <25| <50| dBA
Cooling| Natural convection|
Operating Temperature Range| -40 to +60(8)| °C
Protection Rating| IP65 – Outdoor and Indoor|
Manufacturing Countries| China / Vietnam / Hungary|

(8) Full power up to at least 50°C; for power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating- note.pdf

Connecting CTs to the Revenue Grade and Consumption Meter

Connecting CTs to the Revenue Grade and Consumption
Meter

  • One CT for import/export or consumption metering

© SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc.
All other trademarks mentioned herein are trademarks of their respective owners. Date: 10/2021 DS-000118-1.0-AUS-NZ. Subject to change without notice.

Customers Support

www.solaredge.com

Logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals