robustel MG460 Hardware Maritime Cyber Security Instruction Manual
- September 8, 2024
- robustel
Table of Contents
- robustel MG460 Hardware Maritime Cyber Security
- Product Usage Instructions
- **Regulatory and Type Approval Information
- Radio Specifications for Europe
- Safety Information
- Technical Support
- Overview
- Package Checklist
- Interface Descriptions
- Hardware Installation
- Login to the Device
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
robustel MG460 Hardware Maritime Cyber Security
Specifications
- RF Technologies: 2G, 3G, 4G, GNSS, Wi-Fi
- EU Band Frequencies: 4G LTE FDD – B1/B3/B7/B8/B20/B28/B32, LTE TDD – B34/B38/B40/B42/B43/B46, 3G WCDMA – B1/B8, 2G GSM – B3/B8
- Non-EU Band Frequencies: 4G LTE FDD – B2/B4/B5/B12/B13/B18/B19/B25/B26, LTE TDD – B39/B41, 3G WCDMA – B2/B4/B5/B6/B19, 2G GSM – B2/B5
- Wi-Fi Frequency: 2.4 GHz – 2.412 ~ 2.484 GHz, 5 GHz – 5150-5250MHz, 5745-5825MHz
- GNSS: GPS L1, Galileo E1, GLONASS G1, BDS B1I, SBAS L1 – 1559MHz to 1610MHz, BDS B2a, GPS L5, Galileo E5a – 1164MHz to 1215MHz
Product Usage Instructions
Radio Specifications
Make sure to comply with the specified RF technologies and frequency bands for
operation in Europe and non-EU regions. Follow the guidelines for Wi-Fi
frequency usage and GNSS frequencies.
Radiation Exposure Statement
Adhere to FCC and IC radiation exposure limits by maintaining a minimum
distance of 20cm between the device and your body. Avoid co-location with
other antennas or transmitters.
Disposal and Recycling
Dispose of the product properly by sending it to separate collection
facilities for recovery and recycling. Ensure compliance with relevant EU
directives and UK legislation.
Health Warning
Be aware that the product may expose you to chemicals including Lead, which is
known to cause cancer and reproductive harm. Visit
www.P65Warnings.ca.gov for more information.
FAQ:
Q: Where can I find more product documents or tools?
A: You can find additional product resources at
www.robustel.com/documentation/
MG460
Hardware Manual
Version: 1.0.0
Date: Jun. 14, 2024
Robustel MG460 Hardware Manual
**Regulatory and Type Approval Information
**
Table 1: Toxic or Hazardous Substances or Elements with Defined Concentration Limits
Name of the Part | Hazardous Substances |
---|---|
(Pb) | (Hg) |
Metal
parts
|
X1,2
| o| o| o| –| –| –| –| –| –
Circuit
modules
| o| o| o| o| o| o| o| o| o| o
Cables and cable
assemblies
|
o
|
o
|
o
|
o
|
o
|
o
|
o
|
o
|
o
|
o
Plastic and polymeric
parts
|
o
|
o
|
o
|
o
|
o
|
o
|
o
|
o
|
o
|
o
o:Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in RoHS2.0.
X:Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials for this part might exceed the limit requirement in RoHS2.0.
Indicates that it does not contain the toxic or hazardous substance.
Note: Excessive lead can be exempted.
- Copper alloy containing up to 4 % lead by weight (RoHS Exemption 6(c)).
- Electrical and electronic components containing lead in a glass or ceramic other than dielectric ceramic in capacitors, e.g. piezoelectronic devices, or in a glass or ceramic matrix compound (ROHS Exemption 7(c)-Ⅰ)
Radio Specifications for Europe
RF technologies | 2G, 3G, 4G, GNSS, Wi-Fi*, |
---|---|
Cellular Frequency * | EU Band: |
4G: LTE FDD: B1/B3/B7/B8/B20/B28/B32 LTE TDD: B34/B38/B40/B42/B43/B46 3G: WCDMA: B1/B8
2G: GSM: B3/B8
| Non-EU Band :
4G : LTE FDD: B2/ B4/ B5/ B12/ B13/ B18/ B19/ B25/ B26
LTE TDD: B39/B41
3G : WCDMA: B2/B4/B5/B6/B19
2G : GSM: B2/B5
Wi-Fi Frequency| 2.4 GHz: 2.412 ~ 2.484 GHz
5 GHz: 5150-5250MHz, 5745-5825MHz
GNSS*| GPS L1, Galileo E1, GLONASS G1, BDS B1I, SBAS L1: 1559MHz to 1610MHz BDS B2a, GPS L5,
Galileo E5a: 1164MHz to 1215MHz
Max RF power| 33 dBm±2dB@GSM, 24 dBm+1/-3dB@WCDMA, 23 dBm±2dB@LTE, 19dBm@WiFi
- May vary on difference models.
Note: Operation of 5150 ~ 5250 MHz frequency range is restricted to indoor use only.
Caution: The user is cautioned that changes or modifications not expressly
approved by the party responsible for compliance could void the user’s
authority to operate the equipment.
This device contains licence-exempt transmitter(s)/receiver(s) that comply
with Innovation, Science and Economic Development Canada’s licence-exempt
RSS(s) and Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
Note: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC & IC Radiation Exposure Statement
This equipment complies with FCC and Canada radiation exposure limits set
forth for an uncontrolled environment. This equipment should be installed and
operated with a minimum distance of 20cm between the radiator and your body.
This transmitter must not be co-located or operating in conjunction with any
other antenna or transmitter.
Simplified EU Declaration of Conformity
We, Guangzhou Robustel Co., Ltd. are located at 501, Building #2, 63 Yongan
Road, Huangpu District, Guangzhou, China, declare that this radio equipment
complies with all applicable EU directives. The full text of the EU DoC is
available at the following internet address:
www.robustel.com/certifications/
Safety Information
General
- The router generates radio frequency (RF) power. When using the router, care must be taken on safety issues related to RF interference as well as regulations of RF equipment.
- Do not use your router in aircraft, hospitals, petrol stations or in places where using cellular products is prohibited.
- Be sure that the router will not be interfering with nearby equipment. For example: pacemakers or medical equipment. The antenna of the router should be away from computers, office equipment, home appliances, etc.
- An external antenna must be connected to the router for proper operation. Only uses approved antenna with the router. Please contact the authorized distributor to find an approved antenna.
RF Exposure
- This device meets the official requirements for exposure to radio waves. This device is designed and manufactured not to exceed the emission limits for exposure to radio frequency (RF) energy set by authorized agencies.
- The device must be used with a minimum separation of 20 cm from a person’s body to ensure compliance with RF exposure guidelines. Failure to observe these instructions could result in your RF exposure exceeding the applicable limits.
- Note: Some airlines may permit the use of cellular phones while the aircraft is on the ground and the door is open. Router may be used at this time.
The symbol indicates that the product should not be mixed with general
household waste but must be sent to separate collection facilities for
recovery and recycling.
The symbol indicates that the product meets the requirements of the applicable
EU directives.
The symbol indicates that the product meets the requirements of the relevant
UK legislation.
WARNING
This product can expose you to chemicals including Lead, known to the State of
California to cause cancer and birth defects or other reproductive harm. For
more information go to www.P65Warnings.ca.gov
Related download link
Find more product documents or tools at:
www.robustel.com/documentation/
Technical Support
Tel: 4009-873-791
Email: support@robustel.com
Web: www.robustel.com
Document History
Updates between document versions are cumulative. Therefore, the latest
document version contains all updates made to previous versions.
Date| Firmware Version| Document Version| Change
Description
---|---|---|---
Jun. 14, 2024| 2.1.3| 1.0.0| Initial release.
| | |
| | |
| | |
| | |
| | |
Overview
Robustel’s MG460 is a new generation of industrial maritime gateway which is compliant to IEC61162-460 (Maritime Safety and Security) standards and IEC60945 standards. The MG460 can be used as a gateway between on-board vessel equipment and external services (Cloud platforms, servers, etc).
Package Checklist
Before commencing installation ensure your package has the following components:
Note: The accessories could be different on specific order.
Panel Layout
(May vary on different models, please refer to Table1)
Table1
Model| PN| Cellular Antenna Port| WIFI Antenna Port|
GNSS Antenna Port
---|---|---|---|---
MG460-A5ZAZ-NU| B147001| 0| 0| 0
MG460-A5CAZ-NU| B147002| 0| 2| 0
MG460-A5AAZ-4L-A06GL| B147003| 2| 0| 1
MG460-A5BAZ-4L-A06GL| B147004| 2| 2| 1
Interface Descriptions
- Serial Ports. Two software configurable serial ports, could be configured as RS232 or RS485 or RS422.
Name | RS232 Mode | RS485 Mode | RS422 Mode |
---|---|---|---|
RXD1 or RX1+ | data receiving | data receiving positive | |
CTS1 or RX1- | clear to send | data receiving negative | |
A1/RTS1 or TX1+ | request to send | RS485_A1 | data sending positive |
B1/TXD1 or TX1- | data sending | RS485_B1 | data sending negative |
GND | Ground | Ground | Ground |
RXD2 or RX2+ | data receiving | data receiving positive | |
CTS2 or RX2- | clear to send | data receiving negative | |
A2/RTS2 or TX2+ | request to send | RS485_A2 | data sending positive |
B2/TXD2 or TX2- | data sending | RS485_B2 | data sending negative |
GND | Ground | Ground | Ground |
- Ethernet Ports. 5 Ethernet ports, both of them could be configured as WAN or LAN.
LED | Description |
---|---|
Activity | On, blinking |
Off | No activity |
Link | Off |
On | Link on |
- Reset Button.
Function | Operation |
---|---|
Reboot | Press and hold the RST button for 2~5 seconds under the operating |
status.
Restore to default configuration| Press and hold the RST button for 5 ~10
seconds under the operating status.
The RUN
light flashes quickly, and then release the
RST button, and the device will restore to the default configuration.
Restore to factory
configuration
| Once the operation of restoring the default configuration is performed twice
within one minute, the device will restore to the factory default settings.
- Digital Input and Relay Output.
Two sets of digital inputs and two sets of relay outputs. Some applications for reference are as below:
Note: When the relay is off, NC is connected to COM, and NO is disconnected. The external power supply input voltage range is DC 5-48V, with a maximum load current of 300mA.
Note: The external power supply DC voltage range is 5V~30V, 0.1A max.
Name | Type | Description |
---|---|---|
DI1+ |
Digital I/O
| Digital Input positive
DI1-| Digital Input negative
DI2+| Digital Input positive
DI2-| Digital Input negative
NC1|
Relay Output
| Normally Closed
COM1| Common
NO1| Normally Open
NC2| Normally Closed
COM2| Common
NO2| Normally Open
- LED Indicators
LED | Description |
---|
RUN
| On, solid| Gateway system is initializing
On, blinking| Gateway starts operating
Off| Gateway is powered off
MDM
| Color| With 4G Module:
2G: Red, 3G: Yellow, 4G: Green
On, blinking| Link connection is working
Off| Link connection is not working
****| Green| Strong signal
Yellow| Medium signal
Red| Weak or no signal
VPN| On, solid| VPN connection is established
Off| VPN connection is not established
USR1/USR2| Defined by user. For more details, please refer to RT147_SMMG460
Software Manual:
Services > Advanced > System >System Settings > User LED Type.
Hardware Installation
- SIM Card Installation. Remove the SIM card cover to insert the SIM cards into the device, then screw up the cover.
- Note: To ensure optimal performance and compatibility, it is recommended to use 2FF SIM cards that meet industrial-grade standards and feature an integrated design. 2. Antenna Installation. Rotate the antenna into the antenna connector accordingly. 3. Terminal Block Installation. Insert the 4 PIN,5PIN and 6PIN terminal blocks into the interfaces connector, then can connect the devices or sensors to the gateway with wires via corresponding interfaces. 4. Power Supply installation. Insert the power supply cord into the corresponding terminal block if needed, then insert the terminal block into the power connector 5. DIN Rail Mounting. Use 2 M3 screws to fix the DIN rail to the device, then hang the DIN rail on the mounting bracket. 6. Wall Mounting. Use 4 M3 screws to fix the Wall Mounting kit to the device. 7. Grounding the Device. Grounding will help to prevent the noise effect due to electromagnetic interference (EMI). Connect the device to the site ground wire by the grounding screw before powering on.
Login to the Device
-
Connect the gateway’s Ethernet port to a PC with a standard Ethernet cable.
-
Before logging in, manually configure the PC with a static IP address on the same subnet as the gateway address, click and configure “Use the following IP address”.
-
To enter the gateway’s web interface, type https://192.168.0.1 into the URL field of your Internet browser.
-
Use login information shown in the product label when prompted for authentication.
-
After logging in, the home page of the web interface is displayed, then you can view system information and perform configuration on the device.
-
The automatic APN selection is ON by default, if need to specify your own APN, please go to the menu Interface->Cellular->Advanced Cellular Setting->General Settings to finish the specific setting.
-
For more configuration details please refer to RT147_SM_MG460 Software Manual.(END)
Support: support@robustel.com
Website: www.robustel.com
©2024 Guangzhou Robustel Co.,Ltd.
All rights reserved. Subject to change without notice.
References
- P65Warnings.ca.gov
- p65warnings.ca.gov.
- 4G/LTE/5G/Cellular Routers, Gateways and Modems for Industrial IoT - Robustel
- 4G/LTE/5G/Cellular Routers, Gateways and Modems for Industrial IoT - Robustel
- Certifications | Robustel - Industry-leading IoT Solutions Provide
- Certifications | Robustel - Industry-leading IoT Solutions Provide
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>