dynamic BIOSENSORS AS-1-Gb Adapter Strand 1 User Manual

September 6, 2024
dynamic BIOSENSORS

dynamic BIOSENSORS AS-1-Gb Adapter Strand 1

Key Features

  • Adapter strand 1 – Gb for functionalization of heliX® Adapter Chip Spot 1.
  • Compatible with heliX® Adapter Chip.
  • Includes Adapter strands for 50 regenerations.
  • Ideal for MIX&RUN sample preparation.
  • Adapter strand 1 carries a moderately hydrophilic green dye (Gb) with a negative net charge.

heliX ® Adapter Chip Overview

2 spots with 2 different anchor sequences for DNA-encoded addressing.

Product Description

Order Number: AS-1-Gb

Table 1. Contents and Storage Information

Material| Cap| Concentration| Amount| Buffer| Storage
---|---|---|---|---|---
Adapter strand 1 – Gb| Black| 400 nM| 5 x 100 µL| TE40 [1]| -20°C

  • For research use only.
  • This product has a limited shelf life, please see expiry date on label.
  • To avoid many freeze thaw cycles please aliquot the nanolayer.

Preparation | MIX&RUN

In-solution hybridization of adapter and ligand strands:

  1. Mix Adapter strand 1 – Gb (400 nM) and conjugated Ligand strand (500 nM) at 1:1 ratio (v/v).
  2. Incubate the solution of step 1 at RT at 600 rpm for 30 min to ensure complete hybridization.
  3. Mix solution of step 2 and Adapter strand 1 – Gb – lfs (200 nM) at 1:1 ratio (v/v).
    Solution is ready to use for biochip functionalization.
    Stability of the solution is related to the stability of the ligand molecule.

Table 2. Additional material for functionalization of spot 1 and reference spot 2.

Material| Concentration| Buffer| Related Product Name| Order No
---|---|---|---|---
Ligand strand carrying the conjugated ligand| 500 nM| PE40 [2]| heliX® Amine Coupling Kit 1| HK-NHS-1
Adapter strand 1 – Gb – lfs| 200/250 nM| TE40 [1]| Adapter strand 2 with green dye Gb prehybridize with ligand-free strand| AS-2-Gb-lfs

Example

Required volume for 3 functionalizations: 100 µL with a final concentration of 100 nM.

Vial 1 Vial 2
Adapter strand 1 – Gb (400 nM) Conjugated Ligand strand (500 nM)

strand 1 – Gb – lfs (200/250 nM)
25 µL| 25 µL| 50 µL

After incubation time, mix vial 1 and vial 2 to obtain 100 µL of ready-to-use DNA solution.

Contact

Dynamic Biosensors GmbH
Perchtinger Str. 8/10
81379 Munich
Germany

Dynamic Biosensors, Inc.
300 Trade Center, Suite 1400
Woburn, MA 01801
USA

Order Information order@dynamic-biosensors.com
Technical Support support@dynamic-biosensors.com
www.dynamic-biosensors.com

Instruments and chips are engineered and manufactured in Germany.
©2024 Dynamic Biosensors GmbH | Dynamic Biosensors, Inc. All rights reserved.

[1] TE40: 10 mM Tris, 40 mM NaCl, 0.05 % Tween20, 50 μM EDTA, 50 μM EGTA