CORNING Everon 6200 DAS Wireless Technology Owner’s Manual
- September 5, 2024
- Corning
Table of Contents
CORNING Everon 6200 DAS Wireless Technology
Specifications :
- Supported Bands: Band 600MHz, 700 LU, 700MHz LUPS, 850E MHz, 1900MHz, 2100MHz, 2300MHz, 2500MHz, TDD C-Band-1
- 3GPP Bands: Band 71, 12 & 13, 12 & 13 & 14, 26, 25, 66E, 30, 41, n78
- Downlink Frequencies: 617-652, 729-756, 728-768, 859-894, 1930-1995, 2110-2200, 2350-2360, 2496-2690, 3450-3800
Product Usage Instructions
Installation:
- Ensure the socket-outlet is easily accessible for the device.
- Keep a minimum distance of 20cm between the device’s radiator and your body during installation.
Electrical Information:
- Maximum Power Consumption: AC Power / DC Power
Maintenance :
- Use the provided Dry contact Alarms to monitor the device’s status.
Mechanical Details :
- Dimensions: Width: 440mm, Height: 88mm, Depth: 329mm, Weight: 8.0kg
FAQ :
-
Q: What should I do if the device is not powering on?
A: Check the AC/DC power source and ensure it is connected properly. If the issue persists, contact customer support. -
Q: How can I monitor the device’s output power?
A: Use the AU-AC power level (dB) interface to monitor the input power range for each port.
Everon 6200
A3-E3-N3 Specification Sheet
Features
Features
1200MHz Transmission Bandwidth over 1 fiber| 8 x 3GPP Band per Remote
Sub 6GHz| Up to 200MHz IBW
Dry contact Alarm| 25dBm Maximum Output Power per Band
Support Band or Channel Selective filter| Cascading up to 6 levels
E62-A3 – Access Unit Chassis
- The E62-A3 – Access Unit Chassis is a standard 19-inch 2U rack-mounted shelf (1U fan unit included), which serves as the host for Everon™ 6200. The E62-A3 provides coupling access to radio signal sources of multi-operator, multi-system, and multi-band, forming digital optical signals and distributing static capacity distribution to fiber-connected other type devices. One A3 supports up to eight optical interfaces connected to E3s (Expansion Unit) or N3RUs (Remote Unit).
- This document describes the installation procedure for the E62-N3 remote unit.
- This is NOT a CONSUMER device. It is designed for installation by FCC LICENSEES and QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express consent of an FCC License to operate this device. NOTE: Only authorized person can enter the area where the antenna is installed. And the person is fully aware of the potential for exposure and can exercise control over his or her exposure by leaving the area or by some other appropriate means. Awareness of the potential for RF exposure in a workplace or similar environment can be provided through specific training as part of a RF safety program.
- This device must be professionally installed.
E62-AU-AC – Active Combiner Module
The E62-AU-AC – Active Combiner Module is the interface to the operator base station signal source equipment. Each module has four QMA ports for signal input from the maximum four operators. One Access Unit can be equipped with up to four modules. In accordance with wireless service provider standards, it is not advised to use digital repeaters as a signal source for Corning solutions.
E62-E3-O – Expansion Unit
The E62-E3-O – Expansion Unit is a standard 19-inch 1U rack-mounted shelf, which serves as the interface between the Primary A3 and the Remote Unit for the capacity expansion of system.
E62-N3RU – Low Power Remote Unit
The E62-N3RU is a low-power remote unit supporting cellular technologies on fiber optic cable using the CPRI protocol. The N3 is ideal for multi-operator multi-band, static capacity distribution deployments of cellular services in small-to-medium coverage areas. The N3 supports up to four 25 dBm RF channels. The N3 converts an optical signal to RF and then transmits at the relevant 3GPP band and receives the analog RF signal, conditions it, and converts it back to optical for routing to the E3 or A3.
The socket-outlet shall be easily accessible.
Please take attention that changes or modification not expressly approved by
the party responsible for compliance could void the user’s authority to
operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
Specifications
E62-A3 – Access Unit Chassis
Supported Bands| | | |
---|---|---|---|---
Band| 3GPP Band| Downlink| Uplink| Max IBW
600MHz| 71| 617-652| 663-698| 35
700 LU| 12 & 13| 729-756| 699-716 & 777-787| 27
700MHz LUPS| 12 & 13 & 14| 728-768| 698-716 & 776-798| 40
850E MHz| 26| 859-894| 814-849| 35
1900MHz| 25| 1930-1995| 1850-1915| 65
2100MHz| 66E| 2110-2200| 1710-1780| 90
2300MHz| 30| 2350-2360| 2305-2315| 10
2500MHz TDD| 41| 2496-2690| 2496-2690| 194
C-Band-1| n78| 3450-3800| 3450-3800| 200
C-Band-2| n77| 3700-3980| 3700-3980| 200
---|---|---|---|---
Interface|
---|---
Access Unit RF Interface| QMA Female
Optical Connector Type
| 8 x 25 GBps SFP+ Interfaces
6 to 8 optical connections to E3-O or N3
2 optical connections to Secondary A3s
Transmission Rate| 25 GB/s
AU-AC modules| 4 x AU-AC modules per chassis (RF interface with BTS) Full 3GPP
Band per Module (up
to 200 MHz)
Band Support| 12x 3GPP bands over 1 fiber core (using 2 x Secondary A3)
Dry contact Alarms| 1x RJ45 (2x in, 2x out)
Maintenance Interface| Ethernet RJ45
AU-AC power level (dB)| 0dBm to +15 dBm Input Power Range for each port
Electrical|
---|---
Electromagnetic
Compatibility/Interference (EMC/EMI)
| 3GPP TS38.113
Maximum Power Consumption| 85W
AC Power| 100-240v AC, 50/60Hz
DC Power| 48VDC ± 20%
Environmental|
---|---
Mean Time Between Failure (MTBF)| > 220,000 hours
Operating Temperature| -10°C to +45°C
Storage Temperature| -40°C to +85°C
Humidity| 0% to 90% (Noncondensing)
Cooling| Active
Installation| Wall or 19-in Rack
Ingress Protection Rating| IP30 (Indoor)
Mechanical
AU (Width / Height / Depth / Weight)| 440mm / 88mm / 329mm / 8.0kg
17.32in / 3.46in / 12.95in / 17.64lb
E62-E3-O – Expansion Unit
Interface|
---|---
Optical Connector Type| 16 x 25 GBps SFP+ Interfaces 14x optical connections
to N3RU
1x optical connection to Primary A3 or upper level E3
1x optical connection to lower level E3
Transmission Rate| 25 GB/s
Cascading| Up to 5 x E3-O per Optical connection
Dry contact Alarms| 1x RJ45 (2x in, 2x out)
Maintenance Interface| Ethernet RJ45
Electrical|
---|---
Electromagnetic
Compatibility/Interference (EMC/EMI)
| 3GPP TS38.113
Maximum Power Consumption| 65 W
AC Power| 100-240 VAC, 50/60 Hz
DC Power| 48VDC ± 20%
Environmental|
---|---
Mean Time Between Failure (MTBF)| > 220,000 hours
Operating Temperature| -10°C to +45°C
Storage Temperature| -40°C to +85°C
Humidity| 0% to 90% (Noncondensing)
Cooling| Passive
Installation| Ceiling or Wall
Ingress Protection Rating| IP30 (Indoor)
Mechanical|
---|---
- N3 (Width / Height / Depth / Weight)
- Integrated Antenna Version
|
-
310 mm / 83 mm / 310 mm / 4.5 kg
-
12.20 in / 3.27 in / 12.20 in / 9.92lb
-
N3 (Width / Height / Depth / Weight)
-
External Antenna Version
|
- 310 mm / 83 mm / 310 mm / 4.5 kg
- 12.20 in / 3.27 in / 12.20 in / 9.92lb
Regulation
FCC, UL62368-1, UL 2043
System Topology
Corning Optical Communications LLC • 4200 Corning Place • Charlotte, NC 28216
USA
800-743-2675 • FAX:
828-325-5060 • International:
+1-828-901-5000 •
www.corning.com/opcomm
Corning Optical Communications reserves the right to improve, enhance, and
modify the features and specifications of Corning
Optical Communications products without prior notification. A complete listing
of the trademarks of Corning Optical Communications is available at
www.corning.com/opcomm/trademarks.
All other trademarks are the properties of their respective owners. Corning
Optical Communications is ISO 9001 certified. © 2020 Corning Optical
Communications. All rights reserved.
Corning Optical Communications
E62-A3-E3-N3 Specification Sheet | 28 March 28, 2022 | Page 9
References
- Corning Optical Communications | Fiber Optic Connectivity Solutions | Corning
- Legal Notices | Corning.com