CORNING Everon 6000 G2 Campus and Large Venue Distributed Antenna System Instruction Manual

June 4, 2024
Corning

Everon 6000 G2 Campus and Large Venue Distributed Antenna System
Instruction Manual

File history

Document
title| Everton 6000 G2(3500) commissioning instruction manual
---|---
Document resume
Edition| Organization| Date| Changes (terms)
V1. 0| Xionglin He| 2022-08-01| First release

Foreword

This manual introduces the Everon 6000 G2 commissioning instructions and relevant operating instructions
WEB OMT configuration through IE7/IE8, Firefox and Chrome browsers. Since the system of this product will be constantly updated and the software will be constantly upgraded, the software version described in this manual may be different from the pictures. Therefore, the parameters, specifications, and others in this manual are subject to change without notice.

Abbreviation notes are shown in the following table:
Abbreviation notes Table 1

ALC Automatic Level Control
AGC Automatic Gain Control
ATT Attenuation
BTS Base Transceiver Station
DL Downlink
UL Uplink
ANT Antenna
MCU Main Control Unit
LNA Low Noise Amplifier
OMT Operation & Maintenance Terminal
WebOMT Web Operation & Maintenance Terminal
OP Optical Fiber
WDM Wavelength Division Multiplexer
WCDMA Wideband Code Division Multiple Access
CDMA Code Division Multiple Access
FCC Federal Communications Commission
LTE (3G) Long Term Evolution
MIMO Multiple Input Multiple Output

Abbreviation notes Table 2

OAS Distributed Antenna System
Dru-G2-678 Low Power Remote (20d8m) for 600, 7001.1700U/700FN, 850, 2T2R MIMO

(requires 1x1OG SFP, ordered separately)
Dru-G2-
17192325| Low Power Remote (20dBm) for AWS. PCS, WCS and 2.5GHz (194MHz). 2T2R MIMO (requires 3x1OG SFP. ordered separately)
Dru-G2-25| Low Power Remote (23d8m) for 2.5GHz (194MHz), 2T2R MIMO (requires 1x25G SFP. ordered separately)
Dru-G2-35| Low Power Remote (26d8m) for C-Band, 2T2R MIMO (requires 2x25G SFP, ordered separately)
MRU-G2-25| Mid power remote (8W) for 2.5GHz, 2T2R MIMO, AC power (requires 1x25G SFP. ordered separately)
MRU-G2-35| Mid-power remote (8W) for C-Band. 2T2R MIMO. AC power (requires 2x25G SFP. ordered separately)
RIU-G2-25| Radio Interface Unit (RIU) for 2.5GHz. 8 x 4.3-10 ports, support for either 2 x 4T4R2 or 4 x
212R, input power range: -10-37 dBm
RIU-G2-35| Radio Interface Unit (RIU) for C-Band, 8 x 4.3-10 ports, support for either 2 x 4T4R2 or 4 x
2T2R, input power range: -10-37 dBm
OCU-G2| Digital Conversion Unit (DCU) for FDD and TDD bands. Supports 2 x 8T8R/4 x 4T4R/8 x 2T2R, up to 16 RF Channels. 8 optical ports for DEU connection. 4 optical ports for cascading DAU (requires 25G SFPs. ordered separately)
DEU-G2| Digital Extension Unit (DEU) includes 28 optical ports (HW line rate up to 25Gbps). 4 optical ports for DEU cascade (25Gbps). 24 optical ports for radio connection (dLRU/dMRU/dHRU) (requires 25G SFPs. ordered separately)
DEU-G2-PS| Digital Extension Unit (DEU) includes 28 optical ports (HW line rate up to 25Gbps). 4 optical ports for DEU cascade (25Gbps), 24 optical ports for radio connection (dLRU/dMRU/dHRU). Include 12 x power supply ports (max 100W) (requires 25G SFPs, ordered separately)
DLR-G2-678| Low Power Remote (20d8m) for 600. 7001../700U/700FN, 850. 2T2R MIMO (requires 1x1OG SFP, ordered separately)
Dru-G2-
17192325| Low Power Remote (20dBm) for AWS. PCS, WCS and 2.5GHz (194MHz). 2T2R MIMO (requires 3x1OG SFP. ordered separately)
Dru-G2-25| Low Power Remote (23d8m) for 2.5GHz (194MHz). 2T2R MIMO (requires 1x25G SFP. ordered separately)
Dru-G2-35| Low Power Remote (26dBm) for C-Band, 2T2R MIMO (requires 2x25G SFP, ordered separately)
MRU-G2-25| Mid power remote (8W) for 2.5GHz, 2T2R MIMO, AC power (requires 1x25G SFP, ordered separately)

Operating environment

1.1 Computer hardware configuration requirements

  • Computer: main frequency above 2GHz, memory above 512MB, display resolution: 1024×768 above;
  • With an RJ45 network port;
  • Or with a USB port, external USB to an RJ45 network port.

1.2 Computer software configuration requirements

  • Operating system: Windows XP, Windows 7, Windows 10 and above;
  • Browser: Mozilla Firefox and above, Google Chrome 67 and above, IE9/IE10 and above are recommended;

Overview

The product can use the network management system to query and set the parameters of the network element, so as to complete the daily management and maintenance tasks of the network element. The whole system includes RIU, DCU, DEU, and dLRU. It is connected to the OMT port of DCU through a network cable, and the remote computer
terminal can be connected to the whole system, so as to complete the monitoring of all network elements in the whole network, and complete the parameter inquiry and setting of all RIU, DCU, DEU, and dLRU. The schematic diagram of WEB OMT commissioning is shown in Figure

CORNING Everon 6000 G2 Campus and Large Venue Distributed Antenna System -
figure 1

System connection description of

RIU+DCU+DEU+dLRU (1+1+1+1)

  1. Fiber connection description
    The optical port connection of the system is shown in the figure. The DCU optical port OP1 is connected to the DEU OP-A port, the DCU optical port OP2 is connected to the DEU OP-B port, the DEU OP1 port is connected to the DLR OP1 port, and the DEU OP2 port is connected to the DLR OP2 port.

  2. Equipment wiring is shown in the figure below:

CORNING Everon 6000 G2 Campus and Large Venue Distributed Antenna System -
figure 2

Base station RRU->RIU:
➢ ANT1 of RRU is connected to TX1/RX1, TX2/RX2, TX3/RX3 and TX4/RX4 of RIU;
➢ ANT2 of RRU is connected to TX5/RX5, TX6/RX6, TX7/RX7 and TX8/RX8 of RIU; RIU->DCU (It requests to connect RF cable and network cable between RIU and RCU):
➢ Connect the “PREV” of the RIU panel to the “to RIU” of the DCU panel with the network cable;
➢ TX1 and RX1 of RIU1 are connected to SISORX3 and SISOTX3 of DCU;
➢ TX2 and RX2 of RIU1 are connected to SISORX4 and SISOTX4 of DCU;
➢ TX3 and RX3 of RIU1 are connected to MIMORX3 and MIMOTX3 of DCU;
➢ The TX4 and RX4 of RIU2 are connected to the MIMORX4 and MIMOTX4 of DCU.

CORNING Everon 6000 G2 Campus and Large Venue Distributed Antenna System -
figure 3

Configuration instructions before accessing WEB OMT

After the RIU, DCU, DEU and drew are connected to the local computer through the network cable respectively, the relevant settings of the network parameters of the local computer are required before the normal use of WEB -OMT to access the system. The setting of computer IP is shown in figure 4.1-1:

In figure 4.1 -2, the IP address 192.168.8.102 is only an example. It can be all IP addresses except 101 in the same network segment 192.168.8 (the default IP address of the DAS network element is 192.168.8.1 01). After the above operations, you can log in to WEB -OMT through the browser, address: https://192.168.8.101 , default account: admin, default password: admin; As shown in figure 4.1 -3:

CORNING Everon 6000 G2 Campus and Large Venue Distributed Antenna System -
figure 5

Software upgrade operation instructions

Connect the network cable to the OMT port of the DCU device, and use the WEB browser to access the device IP address:
https://192.168.8.101.After entering the user name and password of the device, the system will enter the WEB configuration page of DCU by default. Click the topology diagram frame of DCU and DEU respectively in the topology diagram area to switch to the corresponding network element WEB configuration page.

CORNING Everon 6000 G2 Campus and Large Venue Distributed Antenna System -
figure 6

5.1 RIU software upgrade instructions
Step1: connect the network cable connecting the local commissioning computer to the DCU network element.
Step 2: click Function —Firmware—Scan to enter the RIU software package selection page, and import the software package M52RIU_V01.00.00.0 1.dnl of the RIU to the device storage area.

CORNING Everon 6000 G2 Campus and Large Venue Distributed Antenna System -
figure 7

Step3: click Upgrade – OK to perform the software upload operation, and the software upload progress will be displayed in real-time under progress. When the progress promp it is 100%, it means that the software package has been uploaded.
CORNING Everon 6000 G2 Campus and Large Venue Distributed Antenna System -
figure 8Step4: wait for the software upload to complete, and click OK. And wait for the device reset to complete (the front panel of the device’s run light flashes for 1s, indicating that the device reset is complete).
5.2 DCU software upgrade instructions
Step1: connect the network cable connecting the local commissioning computer to the DCU network element.
Step2: as shown in figure 5.2 -1, click Function—Firmware—Scan to enter the DCU software package selection page, and import the DCU device software package DCUG2_V01.00.01.41.dnl to the device storage area.

CORNING Everon 6000 G2 Campus and Large Venue Distributed Antenna System -
figure9

Step3: click Upgrade – OK to perform the software upload operation, and the software upload progress will be displayed in real-time under progress. When the progress prompt is 100%, it means that the software package has been uploaded.

CORNING Everon 6000 G2 Campus and Large Venue Distributed Antenna System -
figure 10

Step4: wait for the software upload to complete, and click OK. And wait for the device reset to complete (the front panel of the device’s run light flashes for 1s, indicating that the device reset is complete).

CORNING Everon 6000 G2 Campus and Large Venue Distributed Antenna System -
figure 11

Step5: After the device upgrade and reset is completed, as shown in figure 5.2-4, the software version number of the DCU network element is Everon_6000_DCU_P2V01. 00.01.41 indicates that the software of the DCU network element has been upgraded.

CORNING Everon 6000 G2 Campus and Large Venue Distributed Antenna System -
figure 12

5.3 DEU software upgrade instructions
Step1: connect the network cable connecting the local commissioning computer to the DEU network element.
Step2: as shown in figure 5.3 -1, after entering the WEB configuration page of DEU, click Function—Firmware—Scan to enter the DEU software package selection page, and
import the software package DEUG2_V01.00.01.27.dn to the device storage area.

CORNING Everon 6000 G2 Campus and Large Venue Distributed Antenna System -
figure 13

Step3:click Upgrade – OK to upload the software.

CORNING Everon 6000 G2 Campus and Large Venue Distributed Antenna System -
figure 14

The software upload progress will be displayed in real-time under progress. When the progress prompt is 100%, it means that the software package has been uploaded.

CORNING Everon 6000 G2 Campus and Large Venue Distributed Antenna System -
figure 15

Step4: wait for the software upload to complete, click OK in the pop-up dialog box, wait for the device reset to complete (the front panel of the device run light flashes as 1s, indicating that the device reset is complete), and query the software version of the DEU device as DEUG2_V01.00.01.27 indicates that the software upgrade of DEU is completed.
CORNING Everon 6000 G2 Campus and Large Venue Distributed Antenna System -
figure 16

5.4 Dru software upgrade instructions
Step1: connect the network cable connecting the PC to the WEB OMT port of Dru, and access the IP address of the device through the browser: https://192.168.8.101, enter the user name and password to enter the WEB configuration page of Dru. CORNING Everon 6000 G2 Campus and Large Venue
Distributed Antenna System - figure 17

Step2: as shown in the figure, click Firmware —Scan to upload the software package of Dru, select the software package of Dru, click Upgrade in turn, and click OK to perform the software upgrade operation.

CORNING Everon 6000 G2 Campus and Large Venue Distributed Antenna System -
figure 18

After uploading the software package, wait for the device reset to complete.
Step3: after the device is reset, connect the network cable to the WEB OMT port of the DEU device, click Firmware —Scan to upload the software package of Dru, select the software package of Dru, click Upgrade in turn, and click OK in the pop -up a dialog box to upgrade the software.

System WEB configuration description

Connect the network cable to the OMT port of the DCU and access the IP address of the system through the WEB browser( https://192.168.8.101), the system will pop up whether to access the security access page. Click Accept to enter the system login page. When the system logs in for the first time, the password modification page will pop up. According to the user’s requirements, you can customize the password of any 13-digit alphanumeric field (such as zaq1XSW2CDE34). After logging in to the WEB, the system defaults to the WEB page of DCU, and click Dashborder, enter the topology display area of the system, click the network element block diagram of RIU, DCU and DEU in the topology display area, and you can directly switch to the WEB configuration page of the corresponding network element.

6.1 RIU WEB configuration description
Step1: in the topology display area of the system, click the RIU network element block diagram in the topology display area to enter the WEB configuration page of the RIU.

CORNING Everon 6000 G2 Campus and Large Venue Distributed Antenna System -
figure 19

Step2: set the working mode of the channel to TX/RX, set the RF switch to ON, and set UL ATT, and DL ATT to adjust the signal size of the uplink and downlink output and input channels in turn.

CORNING Everon 6000 G2 Campus and Large Venue Distributed Antenna System -
figure 20

6.2 DCU WEB configuration description
Connect the network cable to the OMT port of the DCU and access the IP address of the system through the WEB browser( https://192.168.8.101), as shown in Figure 2, the system will pop up whether to access the security access page. Click Accept to enter the system login page. When the system logs in for the first time, the password modification page will pop up. According to the user’s requirements, you can customize the password of any combination of letters in the 13-digit number field (such as zaq1XSW2CDE34) After logging into the WEB, the system defaults to the WEB page of DCU. Click the topology display area on the WEB and click the topology box of DCU to switch to the WEB page of DCU for the WEB configuration of DCU. This configuration is only for the signal output of Dru:

CORNING Everon 6000 G2 Campus and Large Venue Distributed Antenna System -
figure 21

Click DCU-RF config and set the band, BW, Signal Mode, and RF switch of channel 5`8 as follows:
Channel 5: Band is N3500F, BW is 250M, Signal Mode is TDD -NR, and RF Switch is on.
Channel 6: Band is N3500F, BW is 250M, Signal Mode is TDD -NR, and RF switch is on.
Channel 7: Band is N3500G, BW is 280m, Signal Mode is TDD -NR, and RF switch is on.
Channel 8: Band is N3500G, BW is 280m, Signal Mode is TDD -NR, and RF switch is on.
UL ATT and DL ATT are the attenuation values of uplink and downlink channels respectively, and the size of signal output can be adjusted according to user needs.

CORNING Everon 6000 G2 Campus and Large Venue Distributed Antenna System -
figure 22

6.3 DEU WEB configuration description
As shown in figure 6.3 -1, click the topology display area on the WEB and the topology of DEU to switch to the WEB page of DEU for WEB configuration of DEU.

CORNING Everon 6000 G2 Campus and Large Venue Distributed Antenna System -
figure 23

Click DEU-Carrier info-Add in turn to complete the carrier configuration of the channel of Dru. The carrier configuration information of the channel is as follows. Configure the carrier center frequency point UL Center Freq. (MHz), DL Center Freq. (MHz), carrier bandwidth BW, signal mode Technology, uplink and downlink attenuation UL ATT (DB), DL ATT (DB) MIMO in turn. When MIMO is set to MIMO 1, it means that the carrier signal outputs a signal from the ANT1 port of Dru, Setting MIMO to MIMO 2 means that the carrier signal outputs the signal from the ANT2 port of Dru. After the configuration is completed, click Finish to complete the carrier configuration.

CORNING Everon 6000 G2 Campus and Large Venue Distributed Antenna System -
figure 24

To realize the carrier output signal from channel 1 SISO of Dru, the configuration information is shown in the figure. The configuration range of UL Center Freq. (MHz) and DL Center Freq. (MHz) is 3450~3700. In this example, 3575M is configured, and the MIMO mode is set to MIMO 1.

CORNING Everon 6000 G2 Campus and Large Venue Distributed Antenna System -
figure 25

To realize the carrier output signal from channel 3 SISO of Dru, the configuration information is shown in the figure. The configuration range of UL Center Freq. (MHz) and DL Center Freq. (MHz) is 3700~3980. In this example, 3840M is configured, and the MIMO mode is set to MIMO 1.

CORNING Everon 6000 G2 Campus and Large Venue Distributed Antenna System -
figure 26

To realize the MIMO output signal of the carrier from channel 2 of Dru, the configuration information is shown in the figure. The configuration range of UL Center Freq. (MHz) and DL Center Freq. (MHz) is 3450~3700. In this example, the configuration is 3575M, and the MIMO mode is set to MIMO 2. CORNING
Everon 6000 G2 Campus and Large Venue Distributed Antenna System - figure
27

To realize the MIMO output signal of the carrier from channel 4 of Dru, the configuration information is shown in the figure. The configuration range of UL Center Freq. (MHz) and DL Center Freq. (MHz) is 3700~3980. In this example, the configuration is 3840M, and the MIMO mode is set to MIMO 2. CORNING
Everon 6000 G2 Campus and Large Venue Distributed Antenna System - figure
28

6.4 Dru WEB configuration description
Click RU-RF Switch to set the switches of the four channels of dLRU to ON/OFF, which means that the RF channel is in the on state, and set the Work Mode to DL Normal Open, which means that the downlink is normally open. And set UL Normal Open, which means that the uplink is normally open.

CORNING Everon 6000 G2 Campus and Large Venue Distributed Antenna System -
figure 29