Window Air Conditioner MAW
USER MANUAL
- MAWO5M1BWT
- MAW06R1CWT
- MAW08R1BWT
- MAW10R1BWT
- MAW12R1BWT
Warning notices: Before using this product, please read this manual carefully and keep it for future reference. The design and specifications are subject to change without prior notice for product improvement. Consult with your dealer or manufacturer for details. The diagram above is just for reference. Please take the appearance of the actual product as the standard.
THANK YOU LETTER Thank you for choosing Midea! Before using your new Midea product, please read this manual thoroughly to ensure that you know how to operate the features and functions that your new air conditioner offers in a safe way.
SAFETY INSTRUCTIONS
Read Safety Precautions Before Operation and Installation
To prevent death or injury to the user or other people and property damage,
the following instructions must be followed. Incorrect operation due to
ignoring of instructions may cause death, harm or damage.
-
WARNING
This symbol indicates the possibility of personnel injury or loss of life. -
CAUTION
This symbol indicates the possibility of property damage or serious consequences.
WARNING
- Installation must be performed according to the installation instructions. Improper installation can cause water leakage, electrical shock, or fire.
- Use only the included accessories and parts, and specified tools for the installation. Using non- standard parts can cause water leakage, electrical shock, fire, and injury or property damage.
- Make sure that the outlet you are using is grounded and has the appropriate voltage. The power cord is equipped with a three-prong grounding plug to protect against shock. Voltage information can be found on the nameplate of the unit.
- Your unit must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker (the fuse or circuit breaker needed is determined by the maximum current of the unit. The maximum current is indicated on the nameplate located on unit), have a qualified electrician install the proper receptacle.
- Install the unit on a flat, sturdy surface. Failure to do so could result in damage or excessive noise and vibration.
- The unit must be kept free from obstruction to ensure proper function and to mitigate safety hazards.
- Do not modify the length of the power cord or use an extension cord to power the unit.
- Do not share a single outlet with other electrical appliances. Improper power supply can cause fire or electrical shock.
- Do not install your air conditioner in a wet room such as a bathroom or laundry room. Too much exposure to water can cause electrical components to short circuit.
- Do not install the unit in a location that may be exposed to combustible gas, as this could cause fire.
- The unit has wheels to facilitate moving. Make sure not to use the wheels on thick carpet or to roll over objects, as these could cause tipping.
- Do not operate a unit that it has been dropped or damaged.
- The appliance with electric heater shall have at least 1 meter space to the combustible materials.
- Do not touch the unit with wet or damp hands or when barefoot.
- If the air conditioner is knocked over during use, turn off the unit and unplug it from the main power supply immediately. Visually inspect the unit to ensure there is no damage. If you suspect the unit has been damaged, contact a technician or customer service for assistance.
- In a thunderstorm, the power must be cut off to avoid damage to the machine due to lightning.
- Your air conditioner should be used in such a way that it is protected from moisture. e.g. condensation, splashed water, etc. Do not place or store your air conditioner where it can fall or be pulled into water or any other liquid. Unplug immediately if it occurs. 3
- All wiring must be performed strictly in accordance with the wiring diagram located inside of the unit.
- The unit’s circuit board(PCB) is designed with a fuse to provide overcurrent protection. The specifications of the fuse are printed on the circuit board, such as: T 3.15A/250V, etc.
- When the water drainage function is not in use, keep the upper and the lower drain plug firmly to the unit to get rid of choking. When the drain plug is not in use, keep it carefully to prevent children from choking.
CAUTION
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
- Children must be supervised around the unit at all times.(be applicable for other countries except the European Countries )
- If the supply cord is damaged, it must be replaced by the manufacturer,its service agent or similarly qualified persons in order to avoid a hazard.
- Prior to cleaning or other maintenance, the appliance must be disconnected from the supply mains.
- Do not remove any fixed covers. Never use this appliance if it is not working properly, or if it has been dropped or damaged.
- Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do not route cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over.
- Do not operate unit with a damaged cord, plug, power fuse or circuit breaker. Discard unit or return to an authorized service facility for examination and/or repair. To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.
- The appliance shall be installed in accordance with national wiring regulations. Contact the authorised service technician for repair or maintenance of this unit. Contact the authorised installer for installation of this unit.
- Do not cover or obstruct the inlet or outlet grilles.
- Do not use this product for functions other than those described in this instruction manual.
- Before cleaning, turn off the power and unplug the unit.
- Disconnect the power if strange sounds, smell, or smoke comes from it.
- Do not press the buttons on the control panel with anything other than your fingers. Do not remove any fixed covers. Never use this appliance if it is not working properly, or if it has been dropped or damaged.
- Do not operate or stop the unit by inserting or pulling out the power cord plug.
- Do not use hazardous chemicals to clean or come into contact with the unit. Do not use the unit in the presence of inflammable substances or vapour such as alcohol, insecticides, petrol,etc.
- Always transport your air conditioner in a vertical position and stand on a stable, level surface during use.
- Always contact a qualified person to carry out repairs. If the damaged power supply cord must be replaced with a new power supply cord obtained from the product manufacturer and not repaired.
- Hold the plug by the head of the power plug when taking it out.
- Turn off the product when not in use.
Electronic Work
-
WARNING:
BEFORE PERFORMING ANY ELECTRICAL OR WIRING WORK, TURN OFF THE MAIN POWER TO THE SYSTEM.NOTE: The cographs are for explanation purpose only. Your machine may be slightly different. The actual shape shall prevail. -
NOTE: The cographs are for explanation purpose only. Your machine may be slightly different. The actual shape shall prevail.
WARNING for Using R32 Refrigerant
- Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
- The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater).
- Do not pierce or burn.
- Be aware that the refrigerants may not contain an odour.
- Appliance should be installed, operated and stored in a room with a floor area according to the amount of refrigerant to be charged. For specific information on the type of gas and the amount, please refer to the relevant label on the unit itself. When there are differences between the lable and the manual on the Min. room area description, the description on label shall prevail.
- Appliance shall be installed, operated and stored in a room with a floor area larger than 4 m2.
- Appliance shall not be installed in an unvertilated space, if that space is smaller than 4 m2.
- No any open fire or device like switch which may generate spark/arcing shall be around appliance to avoid causing ignition of the flammable refrigerant used. Please follow the instructions carefully when storing or maintaining the appliance to prevent mechanical damage from occurring.
- CAUTION:
Risk of fire flammable materials
Explanation of symbols displayed on the unit
| CAUTION| This symbol shows that the operation manual should be read
carefully.
---|---|---
| CAUTION| This symbol shows that a service personnel should be handling
this equipment with reference to the installation manual.
| CAUTION| This symbol shows that information is available such as the
operating manual or installation manual.
WARNING
- Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants.
- DO NOT modify the length of the power cord or use an extension cord to power the unit.
- DO NOT share a single outlet with other electrical appliances. Improper power supply can cause fire or electrical shock.
- Please follow the instruction carefully to handle, install, clear, service the appliance to avoid any damage or hazard.
- When maintaining or disposing the appliance, the refrigerant shall be recovered properly, shall not discharge to air directly.
- Compliance with national gas regulations shall be observed.
- Keep ventilation openings clear of obstruction.
- The appliance shall be stored so as to prevent mechanical damage from occurring.
- A warning that the appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.
- Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry-accredited assessment authority, which authorizes their competence to handle refrigerants safely in accordance with an industry recognised assessment specification. All training shall follow the ANNEX HH requirements of UL 60335-2-40.
- Examples for such working procedures are:
- breaking into the refrigerating circuit;
- opening of sealed components;
- opening of ventilated enclosures.
-
Transport of equipment containing flammable refrigerants
See transport regulations. -
Marking of equipment using signs
See local regulations. -
Disposal of equipment using flammable refrigerants
See national regulations. -
Storage of equipment/appliances
The storage of equipment should be in accordance with the manufacturer’s instructions. -
Storage of packed (unsold) equipment
Storage package protection should be constructed such that mechanical damage to the equipment inside the package will not cause a leak of the refrigerant charge. The maximum number of pieces of equipment permitted to be stored together will be determined by local regulations. -
Information on servicing
-
Checks to the area
Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimised. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system. -
Work procedure
Work shall be undertaken under a controlled procedure so as to minimise the risk of a flammable gas or vapour being present while the work is being performed. -
General work area
All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided. The area around the workspace shall be sectioned off. Ensure that the conditions within the area have been made safe by control of flammable material. -
Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerating detector prior to and during work, to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants, i.e. non-sparking, adequately sealed or intrinsically safe. -
Presence of fire extinguisher
If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or CO2 fire extinguisher adjacent to the charging area. -
No ignition sources
No person carrying out work in relation to a refrigerating system which involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing and disposal, during which flammable refrigerant can possibly be released to the surrounding space. Prior to work taking place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks. No Smoking signs shall be displayed. -
ventilated area
Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere. -
Checks to the refrigerating equipment
Where electrical components are being changed, they shall be fit for the purpose and to the correct specifications. At all times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt consult the manufacturer’s technical department for assistance. The following checks shall be applied to installations using flammable refrigerants: the actual refrigerant charge is in accordance with the room size within which the refrigerant containing parts are installed; the ventilation machinery and outlets are operating adequately and are not obstructed; if an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant; marking to the equipment continues to be visible and legible.
Markings and signs that are illegible shall be corrected; and refrigerating pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components, unless the components are constructed of materials which are inherently resistant to being corroded or are suitably protected against being so corroded. -
Checks to electrical devices
Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used. This shall be reported to the owner of the equipment so all parties are advised. Initial safety checks shall include: That capacitors are discharged: this shall be done in a safe manner to avoid possibility of sparking; that there no live electrical components and wiring are exposed while charging, recovering or purging the system; that there is continuity of earth bonding. -
Sealed electrical components shall be replaced.
-
During repairs to sealed components, all electrical supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers, etc. If it is absolutely necessary to have an electrical supply to equipment during servicing, then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation.
-
Particular attention shall be paid to the following to ensure that by working on electrical components, the casing is not altered in such a way that the level of protection is affected. Check for damage to cables, excessive number of connections, terminals not made to original specification, damage to seals, incorrect fitting of glands, etc. Ensure that apparatus is mounted securely. Ensure that seals or sealing materials have not degraded such that they no longer serve the purpose of preventing the ingress of flammable atmospheres. Replacement parts shall be in accordance with the manufacturer’s specifications.
NOTE: The use of silicon sealant may inhibit the effectiveness of some types of leak detection equipment. Intrinsically safe components do not have to be isolated prior to working on them. -
Intrinsically safe components must be replaced.
Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible voltage and current permitted for the equipment in use. Intrinsically safe components are the only types that can be worked on while live in the presence of a flammable atmosphere. The test apparatus shall be at the correct rating. Replace components only with parts specified by the manufacturer. Other parts may result in the ignition of refrigerant in the atmosphere from a leak. -
Cabling
Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or any other adverse environmental effects. The check shall also take into account the effects of aging or continual vibration from sources such as compressors or fans. -
Detection of flammable refrigerants
Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks. A halide torch (or any other detector using a naked flame) shall not be used. -
The following leak detection methods are deemed acceptable for systems containing flammable refrigerants. Electronic leak detectors shall be used to detect flammable refrigerants, but the sensitivity may not be adequate, or may need re-calibration. (Detection equipment shall be calibrated in a refrigerant-free area.) Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used. Leak detection equipment shall be set at a percentage of the LFL of the refrigerant and shall be calibrated to the refrigerant employed and the appropriate percentage of gas (25 % maximum) is confirmed. Leak detection fluids are suitable for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper pipe-work.
-
If a leak is suspected, all naked flames shall be removed/ extinguished. If a leakage of refrigerant is found which requires brazing, all of the refrigerant shall be recovered from the system, or isolated (by means of shut off valves) in a part of the system remote from the leak.
Removal of refrigerant shall be according to Removal and evacuation. -
Removal and evacuation
When breaking into the refrigerant circuit to make repairs—or for any other purpose- conventional procedures shall be used. However, for flammable refrigerants it is important that best practice be followed, since flammability is a consideration. The following procedure shall be adhered to:
- Safely remove refrigerant following local and national regulations;
- Evacuate;
- Purge the circuit with inert gas (optional for A2L);
- Evacuate (optional for A2L);
- continuously flush or purge with inert gas when using flame to open circuit; and
- open the circuit.
- The refrigerant charge shall be recovered into the correct recovery cylinders if venting is not allowed by local and national codes. For appliances containing flammable refrigerants, the system shall be purged with oxygen-free n flammable refrigerants. This process might compressed air or oxygen shall not be used for purging refrigerant systems.
For appliances containing flammable refrigerants, refrigerants purging shall be achieved by breaking the vacuum in the system with oxygen-free nitrogen and continuing to fill until the working pressure is achieved, then venting to atmosphere, and finally pulling down to a vacuum (optional for A2L). This process shall be repeated until no refrigerant is within the system (optional for A2L). When the final oxygen-free nitrogen charge is used. the system shall be vented down to atmospheric pressure to enable work to take place. The outlet for the vacuum pump shall not be close to any potential ignition sources, and ventilation shall
be available.
-
Charging procedures
In addition to conventional charging procedures, the following requirements shall be followed. Ensure that contamination of different refrigerants does not occur when using charging equipment. Hoses or lines shall be as short as possible to minimise the amount of refrigerant contained in them. Cylinders shall be kept in an appropriate position according to the instructions. Ensure that the refrigeration system is earthed prior to charging the system with refrigerant. Label the system when charging is complete (if not already). Extreme care shall be taken not to overfill the refrigeration system. Prior to recharging the system it shall be pressure tested with OFN. The system shall be leak tested on completion of charging but prior to commissioning. A follow up leak test shall be carried out prior to leaving the site. -
Decommissioning
Before carrying out this procedure, it is essential that the technician is completely familiar with the equipment and all its detail. It is recommended good practice that all refrigerants are recovered safely.
Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to re-use of reclaimed refrigerant. It is essential that electrical power is available before the task is commenced.- Become familiar with the equipment and its operation.
- Isolate system electrically.
- Before attempting the procedure ensure that: Mechanical handling equipment is available, if required, for handling refrigerant cylinders;all personal protective equipment is available and being used correctly; the recovery process is supervised at all times by a competent person; recovery equipment and cylinders conform to the appropriate standards.
- Pump down refrigerant system, if possible.
- If a vacuum is not possible, make a manifold so that refrigerant can be removed from various parts of the system.
- Make sure that cylinder is situated on the scales before recovery takes place.
- Start the recovery machine and operate in accordance with manufacturer’s instructions.
- Do not overfill cylinders. (No more than 80 % volume liquid charge).
- Do not exceed the maximum working pressure of the cylinder, even temporarily.
- When the cylinders have been filled correctly and the process completed, make sure that the cylinders and the equipment are removed from site promptly and all isolation valves on the equipment are closed off.
- k) Recovered refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked.
-
Labelling
Equipment shall be labelled stating that it has been de-commissioned and emptied of refrigerant. The label shall be dated and signed. Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant. -
Recovery
When removing refrigerant from a system, either for servicing or decommissioning, it is recommended good practice that all refrigerants are removed safely. When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery cylinders are employed. Ensure that the correct number of cylinders for holding the total system charge is available. All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant (i.e. special cylinders for the recovery of refrigerant). Cylinders shall be complete with pressure relief valve and associated shut-off valves in good working order. Empty recovery cylinders are evacuated and, if possible, cooled before recovery occurs. The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of the flammable refrigerant. If in doubt, the manufacturer should be consulted. In addition, a set of calibrated weighing scales shall be available and in good working order. Hoses shall be complete with leak-free disconnect couplings and in good condition.
The recovered refrigerant shall be processed according to local legislation in the correct recovery cylinder, and the relevant waste transfer note arranged. Do not mix refrigerants in recovery units and especially not in cylinders. If compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable level to make certain that flammable refrigerant does not remain within the lubricant. The compressor body shall not be heated by an open flame or other ignition sources to accelerate this process. When oil is drained from a system, it shall be carried out safely.
Operation of Current Device
The power supply cord contains a current measuring device that detects damage to the power cord. Test your power supply cord as follows:
- Plug in the air conditioner.
- The power supply cord will have TWO buttons on the plug head. Press the TEST button. You will notice a click as the RESET button pops out.
- Press the RESET Button. You will notice a click as the button engages.
- The power supply cord is now supplying electricity to the unit. (On some products this is also indicated by a light on the plug head.)
NOTE
The power supply cord with this air conditioner contains a current detection
device designed to reduce the risk of fire.
In the event that the power supply cord is damaged, it can not be repaired. It
must be replaced with a cord from the manufacturer.
NOTE
Do not use this device to turn the unit on or off.
Always make sure the RESET button is pushed in for correct operation.
The power supply cord must be replaced if it fails to reset when either the
TEST button is pushed, or it can not be reset. Please contact Customer
Service.
PRODUCT INSTALLATION
WARNING – Before You Begin
- Read these instructions completely and carefully.
- IMPORTANT – Save these instructions.
- IMPORTANT – Observe all governing codes and ordinances.
- We recommend that two people install this product.
- Proper installation is the responsibility of the installer.
- Product failure due to improper installation is not covered under the Limited Warranty.
- You MUST use all supplied parts and use proper installation procedures as described in these instructions when installing this air conditioner.
- Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.
- Do not change the plug on the power cord of the air conditioner.
- Aluminum house wiring may present special problems – consult a qualified electrician.
- When handling the air conditioner, be careful to avoid cuts from sharp metal edges and aluminum fins on front and rear coils. Please wear cut-resistant gloves .
NOTE
Save carton and these Installation Instructions for future reference. The
carton is the best way to store unit during winter, or when not in use.
Window Requirements
Your air conditioner is designed to install in standard double hung windows
with opening widths of 23 to 36 inches (584mm to 914mm).
Tools You Will Need
Installation Hardware
Prepare the Window
Lower sash must open sufficiently to allow a clear vertical opening (see
dimension H in Table 1). Side louvers and the rear of the AC must have clear
air space to allow enough airflow through the condenser for heat removal. The
rear of the unit must be outdoors, not inside a building or garage.
Prepare the Air Conditioner
Before installing the unit, the top rail must be assembled on the unit for some models with a capacity of less than 10,000Btu/h.
-
A. Remove the air conditioner from the carton and place on a flat surface.
-
B. Remove top rail from the packaging material as shown in Fig. A.
-
C. Align the hole in the top rail with those in the top of the unit as shown in Fig. B.
-
D. Secure the top rail to the unit with the 3/8″ Screws as shown in Fig. C.
NOTE
- For safety reasons, all four (4) screws MUST be securely fastened.
- Before installing unit, the top rail must be assembled on the unit.
Install Accordion Panels on Air Conditioner
NOTE
The Top rail and Sliding Panels on each side are offset to provide the
proper,- pitch to the rear of the unit (5/16″).
This ls necessary for proper condensate management and drainage. If you are
not using the Side Panels for any reason, this pitch to the rear must be
maintained.
-
Piece unit on the floor, a bench ore table. Hold the Accordion Panel
In one hand and gently pull back the canter to free the open end. See Fig.1. -
Slide the tree end “I” section of the panel directly Ink> the cabinet as shown In Fig. 2, Slide the panel down. Be sure to leave enough space to slip the top end bottom of the feme into the reels on the cabinet.
-
Once the panel has been Installed on the side of that cabinet. make sure It sits securely Inside the frame channel by making slight adjustments.
-
Slide the top and bottom ends of the frame Into the top and bottom rails of the cabinet. Fig. 3.
-
Slide the panel all the way In and repeat on the other side.
NOTE
If storm window blocks AC. see Fig. 12.
Install Air Conditioner
-
Keep a firm grip on the air conditioner, carefully place the unit into the window opening so the bottom of the air conditioner frame is against the window sill (Fig. 5). Carefully close the window behind the top rail of the unit.
-
NOTE
Check that air conditioner is tilted back per dimension H (Fig. 5) (tilted about 3° to 4° downward to the outside). After proper installation, condensate should not drain from the overflow drain hole during normal use. Adjust the slope if otherwise. -
Extend the side panels out against the window frame (Fig. 6).
Secure Air Conditioner
-
Place the frame lock between the frame extensions and the window sill as shown (Fig. 7 A for Wooden windows), (Fig. 7B for Vinyl-Clad windows). Drive 3/4″ (19 mm) or 1/2″ (12.7 mm) locking screws through the frame lock and into the sill.
-
NOTE
To prevent window sill from splitting, drill 1/8″ (3 mm) pilot holes before driving screws. -
For wooden windows:
Drive 1/2″ (12.7 mm) locking screws through the top rail and into the window sash (Fig. SA). -
NOTE
To prevent window sill from splitting, drill 1/8″ (3mm) pilot holes before driving screws. Drive 1/2″ (12.7mm) locking screws through frame holes into window sash (Fig. 88/SC). -
For Vinyl-Clad windows :
Drive 1/2″ (12.7 mm) locking screws through the top rail and into the window sash (Fig. 88). -
NOTE
Before driving the screws, drill 5 holes into the window through the holes of the top rail and side panel frames as shown (Fig. 88). -
Secure lower sash in place by attaching the sash lock with the 3/4″ (19 mm) or 1/2″ (12.7 mm) screw as shown (Fig. 9).
-
Cut Window sash seal foam and insert it in the space between the upper and lower sashes (Fig. 10).
IF AC IS BLOCKED BY STORM WINDOW
- Add wood as shown in Fig. 12, or remove storm window before air conditioner is installed.
- If storm window frame must remain, be sure the drain holes or slots are not caulked or painted shut. Accumulated rain water or condensation must be allowed to drain out.
REMOVING AC FROM WINDOW
- Turn AC off, and disconnect power cord.
- Remove sash seal from between windows, and unscrew sash lock.
- Remove screws installed through top rail and side panel frames.
- Slide the accordion panels into the rails to close. Keeping a firm grip on the air conditioner, raise the sash and carefully remove.
- Be careful not to spill any condensate while lifting unit from window. Store parts WITH air conditioner
OPERATION INSTRUCTIONS
Normal Sounds
MAWOS Models
MAW08R1 / MAW10R1 / MAW12R1
NOTE
All the illustrations in this manual are for explanation purpose only. The
actual installation may vary.
Air Conditioner Features (general)
WARNING
- To reduce the risk of fire, electrical shock, or injury to people or property, read the SAFETY PRECAUTIONS before operating this appliance.
- This air conditioner is designed to be operated under the following conditions:
Cooling Operation
| Outdoor temperature: 64°F – 1O9°F / 18°C – 43°C
---|---
Indoor temperature: 62°F – 9O°F / 17°C – 32°C
NOTE
- The relative humidity of the room should be less than 80%. If the unit is used in a condition with a relative humidity over 80%, there will be condensed water on the surface of the unit.
- Performance may be reduced outside of these operating temperatures.
Air Conditioner Features (MAW05 Models only)
NOTE
Always wait 3 minutes when turning the unit off and then on again, or when
changing from cool to fan and back to cool. This prevents damage from
occurring to the compressor.
To begin operating the air conditioner. follow these steps:
- Plug in the air conditioner (be sure to follow the power cord instructions).
- Turn the power on to the air conditioner, using the ON/OFF button.
- Set the thermostat to the coldest temperature setting.
- Select the Cool mode setting.
- Adjust the louver for comfortable air flow (see Air Directional Louvers).
- Once the room has cooled, adjust the thermostat to the setting you find most comfortable.
- Make sure the air flow inside and outside is not obstructed by anything.
Air Directional Louvers
- The louvers will allow you to direct the air flow
- Left or Right, or Up and Down (optional on some models) throughout the room as needed.
- Move the Levers from side to side until the desired Left/Right direction is obtained.
- You can also move the LEFT lever to adjust air flow up/down as needed.
Fresh Air Vent Control(on 10-12 K MODELS)
The Fresh Air Vent allows the air conditioner to:
- Recirculate inside air – Vent Closed (See Fig. A)
- Draw fresh air into the room-Vent Open (see Fig. B)
- Exchange air from the room and draws fresh air into the room -Vent and Exhaust Open (see Fig. O
MECHANICAL CONTROL OPERATING INSTRUCTIONS
NOTE:
The controls featured in this manual are representative of many available
models. Your model may offer slightly different features.
Cool Mode
- The desired cool setting is selected by rotating the knob to the right to the appropriate location.
- HI COOL has maximum cooling effect and airflow.
- LO COOL has minimum cooling effect and airflow.
- MED COOL has the intermediate cooling effect and airflow(on some models).
- OFF will completely shut off the unit.
- NOTE: lf your unit is equipped with a vent handle, keep it closed for maximum efficiency.
Fan Mode
Rotate the knob to the left to select your choice of fan speeds for air
circulation. NOTE: When selecting a fan speed, the compressor will not run. On
models with a vent control, this mode can be used to remove stale air from the
room, or to draw fresh air into the room. Check the section “Fresh Air Vent
Control”.
Thermostat
- The thermostat is used to set the desired room temperature when the unit is being operated in the COOL MODE. To set the desired room temperature, rotate the thermostat switch to the desired setting. After the set temperature is achieved the thermostat will automatically start and stop the compressor in order to maintain the desired set temperature.
- Rotate the thermostat selector clockwise for higher cool settings. Higher cool settings will provide lower room temperature. Rotate the thermostat selector counter clockwise for lower cool settings. Lower cool settings will provide higher room temperature.
ELECTRONIC CONTROL OPERATING INSTRUCTIONS
NOTE: Different models have different control buttons and indicator lights. Not all the control buttons and indicator lights describing below are available for the unit you purchased. Please check the control panel of the unit you purchased. The unit can be controlled by the unit control alone or with the remote.
NOTE : The controls featured in this manual are representative of many available models. Your model may offer slightly different features.
TO TURN UNIT ON OR OFF:
Press POWER button to turn unit on or off.
TO CHANGE TEMPERATURE SETTING:
- Press UP/DOWN button to change temperature setting.
- NOTE: Press or hold either UP or DOWN button until the desired temperature is shown on the display.
- This temperature will be automatically maintained anywhere between 62°F(17°C) and 86°F(30°C). lf you want the display to read the actual room temperature, see
- “To Operate on Fan Only section”.
SLEEP FEATURE:
Press Sleep button to initiate the sleep mode. In this mode the selected
temperature will increase by 2°F (1°C) 30 minutes after the mode is selected.
The temperature will then increase by another 2°F (1°C) after an additional 30
minutes. This new temperature will be maintained for 7 hours before it returns
to the originally mode and the unit will continue to operate as originally
programmed. The Sleep mode program can be canceled at any time during
operation by pressing the Sleep button again
TO ADJUST FAN SPEEDS:
Press Fan button to select the Fan Speed in four steps-Auto, Low, Med or High.
Each time the button is pressed, the fan speed mode is shifted. For some
models, the fan speed can not be adjusted.
CHECK FILTER FEATURE:
Press Check Filter button to initiate this feature. This feature is a
reminder to clean the Air Filter for more efficient operation. The LED(light)
will illuminate after 250 hours of operation. To reset after cleaning the
filter, press the Check Filter button and the light will go off.
ENERGY SAVER FEATURE:
Press Energy saver button to initiate this function. This function is
available on COOL, DRY, AUTO (only AUTO-COOLING and AUTO-FAN) modes. The fan
will continue to run for 3 minutes after the compressor shuts off. The fan
then cycles on for 2 minutes at 10 minute intervals until the room temperature
is above the set temperature, at which time the compressor turns back on and
Cooling Starts.
NOTE : In COOL, DRY, and AUTO modes, the energy saver feature will
automatically be on. Press the energy saver button to turn it off.
This feature can be activated from the remote control ONLY. The remote control serves as a remote thermostat allowing for the precise temperature control at its location. To activate the Comfort Sense feature, point the remote control towards the unit and press the Comfort Sense button. The remote displays actual temperature at its location. The remote control will send this signal to the air conditioner every 3 minutes until the Comfort Sense button is pressed again. If the unit does not receive the Comfort Sense signal during any 7 minute interval, the unit will beep to indicate the Comfort Sense mode has ended.
MODE SELECTOR:
To choose operating mode, press Mode button. Each time you press the button, a
mode is selected in a sequence that goes from Auto, Cool, Dry and Fan. The
indicator light adjacent will be illuminated and remain on once the mode is
selected. When the unit is turned off and back on via the power button, the
unit will automatically switch on the Energy Saver function for the following
modes: Cool, Dry, Auto. To operate on AUTO feature:
- When you set the air conditioner to AUTO mode, it will automatically select cooling or fan only operation depending on what temperature you have selected and the current room temperature.
- The air conditioner will control room temperature automatically according to temperature you’ve set.
- In this mode, the fan speed cannot be adjusted as it’s automatically controlled according to temperature setting and room temperature.
To operate on Fan Only:
- Use this function only when cooling is not desired, such as for room air circulation or to exhaust stale air (on some models). (Remember to open the vent during this function, but keep it closed during cooling for maximum cooling efficiency.) You can choose any fan speed you prefer.
- During this function, the display will show the actual room temperature, not the set temperature as in the cooling mode. In Fan Only mode, the temperature is not adjusted.
To operate on DRY mode:
In this mode, the air conditioner will generally function as a dehumidifier.
Since the conditioned space is a closed or sealed area, some degree of cooling
will occur.
To operate on Auto feature:
- When you set the air conditioner in AUTO mode, it will automatically select cooling, heating (cooling only models without), or fan only operation depending on what temperature you have selected and the room temperature.
- The air conditioner will control room temperature automatically round the temperature point set by you.
- In this mode, the fan speed cannot be adjusted, it starts automatically at a speed according to the room temperature.
To operate on Fan Only:
- Use this function only when cooling is not desired, such as for room air circulation or to exhaust stale air(on some models). (Remember to open the vent during this function, but keep it closed during cooling for maximum cooling efficiency.) You can choose any fan speed you prefer.
- During this function, the display will show the actual room temperature, not the set temperature as in the cooling mode.
- In Fan only mode ,the temperature is not adjusted.
To operate on Dry mode:
In this mode, the air conditioner will generally operate in the form of a
dehumidifier. Since the conditioned space is a closed or sealed area, some
degree of cooling will continue. On Dry mode, the fan speed is controlled at
Low automatically
TIMER: AUTO START/STOP FEATURE:
-
When the unit is on, press the Timer button. The “Timer off ” LED indicator light will illuminate indicating the Auto stop feature has been activated. – When the unit is off, press the Timer button. The “Timer on” LED indicator light will illuminate indicating the Auto start feature has been activated.
-
When the time of TIMER ON is displayed, press the Timer button again. The TIMER OFF indicator light illuminates. It indicates the Auto Stop program has initiated.
-
Press or hold the UP or DOWN button to change the Auto time by 0.5 hour increments, up to 10 hours, then at 1 hour increments up to 24 hours. The control will count down the time remaining until start
-
The selected time will register in 5 seconds, and the system will automatically revert back to display the previous temperature setting or room temperature when the unit is on. (when the unit is off , there is no display.) The selected time indicates the amount of time after the current time which you want the unit to turn on or off. If you select Timer On and adjust the time to 2.0h, the unit will turn on 2 hours after the current time. Turning the unit ON or OFF at any time or adjusting the timer setting to 0.0 will cancel the Auto Start/Stop timed program.
-
NOTE : To cancel timer operation, press and hold the timer button for 2 seconds until the beep/buzzer is heard
-
Shows the set temperature in ” °C” or ” °F” and the Auto-timer settings. While on Fan only mode, it shows the room temperature. If the room temperature is too high or low, it will display ” HI” or ” LO”.
Error codes:
-
AS – Room temperature sensor error
-
ES -Evaporator temperature sensor error
NOTE: ” • ” is displayed as shown in the above picture. -
HS -Electric heating sensor error(on some models);
-
CS -Condenser temperature sensor error (on some models);
-
OS -Outside temperature sensor error (on some models);
-
E7 -Unit malfunction(on some models).
-
NOTE: When error occurs, unplug the unit and plug it back in. If error repeats, call for service.
NOTE:
If the unit breaks off unexpectedly due to loss of power, it will restart
with the previous function setting automatically when the power resumes
ADDITIONAL THINGS YOU SHOULD KNOW
- Now that you have mastered the operating procedure, here are more features in your control that you should become familiar with.
- The Cool circuit has an automatic 3 minutes time delayed start if the unit is turned off and on quickly.
- This prevents overheating of the compressor and possible circuit breaker tripping.The fan will continue to run during this time.
- The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius.
- To convert from one to the other, press and hold the Up and Down buttons at the same time for 3 seconds.
REMOTE CONTROL INSTRUCTIONS
Handling the Remote Control
Location of the remote control
Use the remote controller within a distance of 26.2 ft (8 meters) from the air
conditioner, pointing it towards the receiver. Reception is confirmed by a
beep.
CAUTION
- The air conditioner will not operate if curtains, doors or other materials block the signals from the remote control to the unit.
- Prevent any liquid from spilling onto the remote control. Do not expose the remote control to direct sunlight or heat.
- If the infrared signal receiver on the indoor unit is exposed to direct sunlight, the air conditioner may not function properly. Use curtains to prevent the sunlight from falling on the receiver.
- If other electrical appliances react to the remote control, either move these appliances or consult your local dealer.
NOTICE
- Button design is based on typical model and may vary slightly from the actual one you purchased.
- All the functions described are accomplished by the unit. If the unit is without a feature, the unit will not respond if the corresponding button on the remote is pressed.
- When there are significant differences between features or operation implied by the remote control illustration and the actual functions described in the User Manual, refer to the descriptions in the user manual.
Remote Controller Specifications
- Rated Voltage: 3.0V (Dry batteries R03/LR03x2)
- Environment: 23°F -140°F (-5°-60°)
Function Buttons
NOTE : Model RGSlGS (l)/CEUl does not have HEAT feature.
Remote Screen Indicators
Information is displayed when the remote control is powered up.
- Displayed when data transmitted.
- Appears when the remote is enabled and can send a signal to the unit. If you would like to turn the remote off without affecting the unit, point the remote away from the unit and press the ON/OFF button. To turn the remote on, point the remote away from the unit and press the ON/OFF button. The unit will not receive commands from the remote if this indicator is not illuminated.
Fan speed indication
- ► HIGH High speed
- ► MED Medium speed
- LOW Low speed
- NO display Auto fan speed
Note: All indicators shown in the figure are for the purpose of clear presentation. But during the actual operation, only the relative function signs are shown on the display window.
How to Use the Buttons
TIMER OPERATION
Press the TIMER button to initiate the Auto-start and Auto-stop setting
program of the unit.
To set the Auto-start/stop time.
- Press the TIMER button, when the TIMER ON indicator is displayed on the LED window of the air conditioner, it indicates the Auto Start setting program is initiated. When the TIMER OFF indicator is displayed on the LED window of the air conditioner, it indicates the Auto Stop setting program is initiated.
- Press or hold the TEMP UP (“‘)/DOWN (v) to change the Auto time. The control will count down the time remaining until start/stop.
- The selected time will register in 5 seconds and the air conditioner will automatically revert back to display the previous temperature setting.
- Turning the unit ON or OFF at any time will cancel the Auto Start/stop function
NOTES
To cancel the TIMER setting, push the TIMER button and press or hold the TEMP
UP (“‘)/ DOWN (∨) until O hour is displayed on the LCD window of the air
conditioner.
COMBINED TIMER
(Setting both ON and OFF timers simultaneously)
AUTO STOP >AUTO START (On > Stop > Start operation)
Example:
To stop the air conditioner 2 hours after setting and start it again 10 hours
after setting.
- Press the TIMER button until the TIMER OFF indicator is displayed on the LED display of the air conditioner.
- Use the TEMP UP (“‘-)/DOWN (v) button to display “2.0” on the LED display of the air conditioner.
- Press the TIMER button again to display the TIMER OFF on the LED display of the unit.
- Use the TEMP UP (“‘-)/DOWN (v) button to display “10” on the LED display of the unit.
- Wait for 5 seconds until the previous display appears in LED window.
AUTO START > AUTO STOP (Off > Start > Stop operation)
Example :
To start the air conditioner 5 hours after setting, and stop it 8 hours after
setting.
- Press the TIMER button until the TIMER ON indicator is displayed on the LED display of the air conditioner.
- Use the TEMP UP (“‘-)/DOWN (v) button to display “5.0” on the LED display of the air conditioner.
- Press the TIMER button again to display the TIMER OFF on the LED display of the unit.
- Use the TEMP UP (“‘-)/DOWN (v) button to display “8.0” on the LED display of the unit.
- Wait for 5 seconds until the previous display appears in LED window.
NOTES
Button design is based on a typical model and may slightly vary from the
actual one you purchased.
FCC STATEMENT
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not approved by the party responsible for compliance could void users authority to operate the equipment.
Battery Warning:
Do not mix old and new batteries and Do not mix alkaline, standard (carbon-
zinc) or rechargeable (ni-cad, ni-mh, etc.) batteries
Supplier’s Declaration of Conformity
47 CFR § 2.1077 Compliance Information
- Unique Identifier: M idea brand, RG51G5(1)/CEU1
- Responsible Party U.S. Contact Information Midea America Corporation 300 Kimball Dr Parsippany NJ 07054
- Telephone number or internet contact information: Midea.com/us
FCC Compliance Statement ( products subject to Part 15)
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
CLEANING AND MAINTENANCE
CAUTION
Clean your air conditioner occasionally to keep it looking new. Be sure to
unplug the unit before cleaning to prevent shock or fire hazards.
Air Filter Cleaning
The air filter should be checked at least once every two weeks to see if cleaning is necessary. Trapped particles in the filter can build up and cause an accumulation of frost on the cooling coils and reduce performance.
- Grasp the filter by the center and pull up and out.
- Wash the filter using warm water. Rinse filter thoroughly.
- Gently shake excess water from the filter. Be sure the filter is thoroughly dry before replacing. Instead of washing, you may also vacuum the filter clean rather than washing
NOTE
Never use hot water over 104°F (40°C) to clean the air filter.
Never attempt to operate the unit without the air filter.
Cabinet Cleaning
- MAW0S Models Only
- MA W06 Models Only
- Be sure to unplug the air conditioner to prevent shock or fire hazard. The cabinet and front may be dusted with an oil-free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent. Rinse thoroughly and wipe dry.
- Never use harsh cleansers, wax, or polish on the cabinet front.
- Be sure to wring excess water from the cloth before wiping around the controls. Excess water in or around the controls will cause damage to the air conditioner
Winter Storage
If you plan to store the air conditioner during the winter, remove it
carefully from the window according to the installation instructions. Cover
the unit with plastic or return it to the original carton.
TROUBLESHOOTING TIPS
Before calling for service, review this list. It may save you time and expense. This list includes common occurrences that are not the result of defective workmanship or materials in this appliance.
WARRANTY
Air Conditioner Limited Warranty
Your product is protected by this Limited Warranty:
Warranty service must be obtained from Midea Consumer Services or an
authorized Midea servicer.
Warranty
- Year Full Warranty from original purchase date.
- Midea, through its authorized servicers will:
- Pay all costs for repairing or replacing parts of this appliance which prove to be defective in materials or workmanship.
Consumer will be responsible for:
- Diagnostics, removal, transportation and reinstallation cost required because of service.
- Costs of service calls that are a result of items listed under NORMAL RESPONSIBILITIES OF THE CONSUMER**
- Midea replacement parts shall be used and will be warranted only for the original warranty.
NORMAL RESPONSIBILITIES OF THE CONSUMER**
This warranty applies only to products in ordinary household use, and the
consumer is responsible for the items listed below:
- Proper use of the appliance in accordance with instructions provided with the product.
- Routine maintenance and cleaning necessary to keep the good working condition.
- Proper installation by an authorized service professional in accordance with instructions provided with the appliance and in accordance with all local plumbing, electrical and/or gas codes.
- Proper connection to a grounded power supply of sufficient voltage, replacement of blown fuses, repair of loosen connections or defects in house wiring.
- Expenses for making the appliance accessible for servicing.
- Damages to finish after installation.
EXCLUSIONS
This warranty does not cover the following:
- Failure caused by damage to the unit while in your possession (other than damage caused by defect or malfunction), by its improper installation, or by unreasonable use of the unit, including without limitation, failure to provide reasonable and necessary maintenance or to follow the written Installation and Operating Instructions.
- Damages caused by serviced performed by persons other than those authorized by Midea customer service; or external causes such as abuse, misuse, inadequate power supply or acts of God.
- If the unit is put to commercial, business, rental, or other use or application other than for consumer use, we make no warranties, express or implied, including but not limited to, any implied warranty of merchantability or fitness for use or purpose.
- Products without original serial numbers or products that have serial numbers which have been altered or cannot be readily determined.
NOTICE: Some states do not allow the exclusions or limitation of incidental or consequential damages. So this limitation or exclusion may not apply to you
IF YOU NEED SERVICE
Keep your bill of sale, delivery slip, or some other appropriate payment
Record.
The date on the bill establishes the warranty period, should service be
required.
If service is performed, its your best interest to obtain and keep all
receipts.
This written warranty gives you specific legal rights. You may also have other
rights that vary from state to state.
Service under this warranty must be obtained by following these steps, in
order:
- Contact Midea Consumer Services or an authorized Midea services at 1 866 646 4332.
- If there is a question as to where to obtain service, contact our consumer relations Department.
www.midea.com
© Midea 2023 all rights reserved CWSO02IU-TYN8(GF) 16120300A31760 20231221