LIGHT SKY PL1215 IP66 Waterproof LED Par Light User Manual
- June 4, 2024
- LIGHT SKY
Table of Contents
- LIGHT SKY PL1215 IP66 Waterproof LED Par Light
- SAFETY INFORMATION
- TECHNICAL INFORMATION
- ATTACHMENT AND BODY SIZE
- INSTALLATION AND CONNECTING
- CONTROL PANEL
- MENU SETTING
- CHANNEL FUNCTION
- Circuit connecting diagram
- CLEANING AND MAINTENANCES
- TROUBLESHOOTING
- DUTY EXONERATIVE AND COPYRIGHT PROTECTION
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
LIGHT SKY PL1215 IP66 Waterproof LED Par Light
Congratulations on choosing our company product! We thank you for your custom.
- Please note that this product, as all the others in the rich my company range, has been designed and made with total quality to ensure excellent performance and best meet your expectations and requirements.
- Carefully read this user manual in its entirety and keep it safe for future reference. It is essential to know the information and comply with the instructions given in this manual to ensure the fitting is installed, used, and serviced correctly and safely.
- My Company disclaims all liability for damage to the fitting or to other property or persons deriving from installation, use, and maintenance that have not been carried out in conformity with this user manual, which must always accompany the fitting.
- My Company reserves the right to modify the characteristics stated in this user manual at any time and without prior notice.
The temperature of the external surface
The maximum temperature that can be reached on the external surface of the
fitting, in a thermally steady state, is 80C. Avoid contact with persons and
materials. Allow the fixture to cool for at least 5 minutes before handling.
Maintenance
Before starting any maintenance work or cleaning the projector, cut off power
from the main supply. After switching off, do not remove any p
The light source
The light source in this fixture shall be replaced by the manufacturer or its
service agent or similar qualification. Always disconnect from the mains before
replacing the light.
Protection against explosion
The protection screen, lens or ultraviolet screen on the lamp can be damaged
to the degree of failure if visible damage, such as a crack or deep mark,
should be replaced。
Protection optical radiation
Never look directly into the light source. You risk injury to your retina,
which may induce blindness. Do not look at LEDs with magnifiers, telescopes,
binoculars or similar optical instruments that may concentrate the light
output.
The products referred to in this manual conform to the European Community Directives to which they are subject: Low Voltage 2014/35/EU Electromagnetic Compatibility 2014/30/EU.
SAFETY INFORMATION
This lighting fixture is for professional use only – it is not for household use.
Installation
Make sure all parts for fixing the projector are in a good state of repair.
Make sure the point of anchorage is stable before positioning the projector.
The safety chain must be properly hooked onto the fitting and secured to the
framework. When suspending the fixture, ensure that the supporting structure
and all hardware used can hold at least 10 times the weight of all the devices
they support.
Mounting surface and fire protection
Please do not install the fixture onto the combustible surface. Keep all
combustible materials at least 20 cm away from the fixture. Ensure a minimum
clearance of 0.2m around the cooling fans and ventilation. Do not expose the
front glass to sunlight or another strong light source from any angle. Lenses
can focus the sun’s rays inside the fixture, creating a potential fire hazard.
Maximum ambient temperature
This fixture is suitable for indoor use and wet locations. Do not immerse in
water.
The ambient temperature Ta: -20 C~40’C.
Protection against electrical shock
The connection must be made to a power supply system fitted with efficient
earthing (Class I appliance according to standard EN 60598-1). It is,
moreover, recommended to protect the supply lines of the projectors from
indirect contact andlor shorting to earth by using appropriately sized
residual current devices.
Connection to the mains supply
The double insulation between the LV power supply and the control conductor on
the fixture. Connection to the electricity mains must be carried out by a
qualified electrical installer. Check that the mains frequency and voltage
correspond to those for which the projector is designed as given on the
electrical data label.
This label also gives the input power to which you need to refer to evaluate the maximum number of fittings to connect to the electricity line, in order to avoid overloading. Don’t use the power cable when the insulation is damaged. It must be the manufacturer or distributor or the professional person to change the damaged power cable in order to avoid any danger.
TECHNICAL INFORMATION
-
Power supplies available: AC100~240V 50/60Hz
-
Power: 157W/PF 0.96 1.6A
-
Light Source: TYANSHINE 15W, RGBW 4 in 1 LED chip.
-
LED QTY: 12PCS.
-
Average life:30000h
Lens & Zoom: High precision combination lens, linear adjustment. -
Beam angle: Zoom function min.7°, max.55°
-
Color: RGBW macro color system.
-
CCT: Color temperature adjustable range: 2500~10000K
-
CRI: Ra ≥75
-
Material of lens: PMMA
-
Strobe:1-30 times/second electronic strobe and random strobe.
-
Dimmer: Electronic dimmer, provides four dimming options.
-
Control Mode :DMX512, RDM.
-
Channel: standard mode 9CH, simple mode 5CH
Software upgrade: Update via DMX link Channel. -
Display Menu:
- The display panel adopts a 0.9-inch OLED screen, which is used in both Chinese and English languages to facilitate quick operation and browsing menus.
- The display board can record the device’s using time, and show the device’s temperature, channel data, and software version.
-
IP protection level:IP66
-
Safety Devices: Bipolar circuit breaker with thermal protection.
-
Cooling: Natural heat dissipation.
-
Outlooking: Housing with high-pressure engineering plastic, anti-UV, anti-high temperature and anti-aging.
Light size: 334X242X432MM- N.W.: 7.2Kg
-
Box Size (1 sets): 330X330X475MM
- N.W.:7.2Kg G.W.:9.2Kg
-
Box Size (4 sets):685X685X500MM
- N.W.:28.4Kg G.W.:37.2Kg
-
Fly case Size (6 sets):915X795X630MM
- N.W.:43.2Kg G.W.:82.5Kg
Distance, spot diameter, and illumination diagram
ATTACHMENT AND BODY SIZE
Body Size
INSTALLATION AND CONNECTING
Installing the projector
The projector can be installed on the floor resting by means of brackets, on a truss or on the ceiling or wall.
WARNING:
with the exception of when the projector is positioned on the floor, the
safety rope must be fitted. This must be securely fixed to the support
structure of the projector and then connected to the fixing point at the
center of the base.
Make sure all parts for fixing the projector are in a good state of repair. Make sure the point of anchorage is stable before positioning the projector. When suspending the fixture, ensure that the supporting structure and all hardware used can hold at least 10 times the weight of all the devices they support.
Our company is fully operational in any mounting position, hanging upside- down, side-mounted, or set on a flat level surface, etc. Be sure this fixture is kept at least 0.5m (about 1.6feet) away from any flammable materials (decoration etc.). When clamp mounting; always use and install the supplied safety cable as an added safety measure to prevent accidental damage in the event of a clamp failure. Connecting to the mains supply
- connection to the electricity mains must be carried out by a qualified electrical installer.
- After doing the above operation and making sure all the devices had been installed with the natural operation, press the power switch to check whether everything is working normally.
Connecting to the control signal line (DMX)
- Please use the round 3 or 5-pin XLR plugs &sockets offered by the menu facture to connect the output of the first projector to the second projector’ input and connect the second projector’s output to the third projector’s input. And in the same way the rest, eventually, connect the last projector’s output, all the projectors are together.
- The projectors control signal output or input by using the 3 or 5-pin XLR plug and socket. If need to lengthen the communication cable, please make sure both sides of the 3 or 5-pin plug is one to one. (one to one, two to two, three to three). Otherwise, the communication cable will be interrupted. The communication cable is 2-cord screened cable 759 resistance with each core is at least a 0.5mm diameter. (Caution: All the inside leading wires of 3 or 5-pin XLR plugs couldn’t touch each other or plinth).
- Recommend using the DMX signal terminator for the installation to avoid the electronic noise damage the digital control signal. Simply speaking, a DMX terminator is an XLR connector with a 1200 1/2W resistor connected across pins 2 and 3. Which is then plugged into the output socket on the last project
- tor in the chain. Refer to the connection.
CONTROL PANEL
- Up arrowhead: page up
- Down arrowhead: page down
- Left arrowhead: reduce
- Right arrowhead: increase
- .Enter : OK function
- Exit: in the choice screen
MENU SETTING
CHANNEL FUNCTION
channel(Standard 9CH)
channel(Simplement 5CH)
Circuit connecting diagram
CLEANING AND MAINTENANCES
- In order to ensure the projector could work normally. It should be kept clean always. The lens should also be regularly cleaned to maintain optimum light output. Do not use any type of solvent on the lens. It will damage the projector.
- Suggestion: The continued usage of the light doesn’t exceed 4 hours. Or it will shorter the usage of the lamp. Please use the alternative operation to solve this problem. The fixture power ON time is best not over 48 hours, or it would generate lamp protection procedure.
- Please disconnect the power supply when beginning maintenance and take down the light. Please let the parts cool down for 10 minutes at least then begin to install.
- Please inspect the lens or other moving parts’ timing and keep them clear and static. If find anything damaged or loose must change a lamp or fix the lamp in order to avoid an accident. please check the mechanical parts is jamging. After cleaning, please add some temperature -durable juice.
- The lamps and lanterns adopt natural heat dissipation. It is easy for the dirty to be collected. Please clear the hot soak once time two weeks at least.
- After you use the light, please check the intake place whether there is some wastepaper, please clean it up, or the windmill will break down and cause a fire.
CAUTION!
Disconnect from mains before starting maintenance operation.
TROUBLESHOOTING
It is recommended some solution for some normal troubleshooting. Any inextricability problems should always be handled by a professional person. Disconnect the power supply before maintaining the light.
LED off/LED:
- Please check if install the suitable voltage
- Please check whether the led will reach the end of their life can explode; please replace a same description led.
- Please check if the power supply is enough.
- Please check whether the DMX 512 controller passes the “turn on” order.
The light couldn’t accept the control order:
- Please check the start code address and the function option are correct.
- Please check whether the communication control cable is in good connection or if the cable is too long or interrupted.
- Please check if the control system is not valid, and check the signal amplifier of the chain connected is valid.
- Please check whether the communication cable is too long or if the other equipment is mutually conjugate.
- Please arrange the wire well, shorter the signal cable, and put the high voltage cable and low voltage cable separately.
- Add the signal amplifier isolator.
- Signal cable is used for the excellent screening doublet (Resistance 75 OHM)
- The end of the light end and the end resistance.
The light can’t move:
- Please check if the power supply is suitable for the light voltage data.
- Please check the light if they are deformation, inside parts is broken, become wet, etc will lead the loose contact.
- Please check if the inside lead wire and the connector is loose.
- Please check if the electric parts(such as the transformer, PCB board, and controller) are short-circuited or burned down.
DUTY EXONERATIVE AND COPYRIGHT PROTECTION
- The Light belongs to consumer products that are not guaranteed to keep it in good repair.
- Any product broken that didn’t according to the instruction is not guaranteed to keep it in good repair.
- The commentary for all the instructions belongs to the supplier in the final.
- No authorization can’t copy.
- The information in this manual may be changed in the future, the company reserve the right to change the data without any advice.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>