DELL S6100-ON Networking Switch User Guide

June 12, 2024
Dell

DELL logo S6100-ON Networking Switch
User Guide

S6100-ON Networking Switch

Dell System S6100–ON 9.14(2.14) Release
Notes
This document contains information about open and resolved caveats, and operational information specific to the Dell
Networking operating software (OS) and the S6100-Open Networking (ON) platform.
Current Release Version: 9.14(2.14)
Release Date: 2022-04-15
Previous Release Version: 9.14(2.12)
NOTE: This document may contain language that is not consistent with current guidelines of Dell Technologies. There are plans to update this document over subsequent releases to revise the language accordingly.
Incorrect behavior or unexpected caveats are listed as the Problem Report (PR) numbers within the appropriate sections.
For more information about hardware and software features, commands, and capabilities, see the Dell Networking website at: http://www.dell.com/en- us/work/learn/networking.

Document Revision History

Table 1. Revision History

Date Description
2022–04 Initial release.

Requirements

The following requirements apply to the S6100-ON system.
Hardware Requirements
The following lists the Dell S6100-ON system hardware requirements:

  • Up to four I/O modules of 8 x 10/25/40/50/100 GbE QSFP28 port
  • Up to four I/O modules of 16 x 10/40 GbE QSFP+ ports
  • Up to four I/O modules of 4 x 10/25/40/50/100 GbE QSFP28 ports and 4 x 100 GbE CXP ports
  • Up to one hundred twenty-eight 10G ports
  • Up to one hundred twenty-eight 25G ports
  • Up to sixty-four 40G ports
  • Up to sixty-four 50G ports
  • Up to thirty-two 100G ports
  • One each RJ–45 management and console ports, micro universal serial bus (MicroUSB-B) 2.0 port, and USB type A port
  • Two small form-factor pluggable plus (SFP+) 10G ports
  • Two AC or DC power supply units (PSUs)
  • Four fans with airflow from the I/O side to the power supply unit (PSU) side or from the PSU side to the I/O side (optional fan subsystem available)

The following lists the individual Dell S6100-ON system hardware components that are available to order:

● Fan with airflow from I/O side to PSU side (red—normal air flow direction)
● Fan with airflow from PSU side to I/O side (blue—reversed air flow direction)
● AC or DC power supply with airflow from I/O side to PSU side
● AC or DC power supply with airflow from PSU side to I/O side

NOTE: Fan modules and power supplies are field replaceable units.
NOTE: All fans and PSUs must have the same airflow direction. If you mix the airflow direction, the switch detects the discrepancy, issues an alarm, and may autoshutdown to avoid heat damage to components. You must correct the mixed airflow direction.

Software Requirements

Table 2. Software Requirements

Software Minimum Release Requirement
Dell Networking OS 9.14(2.14)
ONIE 3.25.1.3
DIAG-OS 3.25.4.1

NOTE: For information about non-Dell OS versions, see Dell S6100-Open Networking (ON) System Release Notes.
New Dell Networking OS Version 9.14(2.14) Features
The following features are integrated into the Dell Networking 9.14.2 branch through this release: None.

Restrictions

  • You can use non-Dell qualified cables, adapters, and optics in a S6100-ON switch, but Dell Networking does not guarantee their performance as the S6100-ON does not support non-Dell qualified transceivers of 25G and above. If you insert a non-Dell qualified transceiver of 25G and above into a SFP28, QSFP+, or QSFP28 port, the switch places the interface in an error-disabled (operationally down) state and generates a syslog message, such as: % S 6 1 0 0 L C 0 6 4 0 : 8
    % I F A G T – 2 – T R A N S C E I V E R U N S U P P O R T E D E R R O R : T r a n s c e i v e r i n s l o t 1 p o r t 4 9 u n r e c o g n i z e d , p u t t i n g i n t e r f a c e i n o p e r a t i o n a l – d o w n s t a t e.
    To verify the error-disabled status of an interface, enter any of the following show commands.

DELL S6100-ON Networking Switch - fig 1

  •  Prerequisite steps to upgrade the Dell Networking OS from earlier version to 9.14.2.0 or later:
    1. Uninstall the older version of the Open Automation (OA) package
    2. Upgrade the Dell Networking OS to 9.14.2.0 or later version
    3. Install the following OA packages from the respective upgraded version:
    a. SmartScripts
    b. Puppet
    c. Open management infrastructure (OMI)
    d. SNMP MIB

Prerequisite steps to downgrade the Dell Networking OS from 9.14.2.0 or later to the earlier version:

  1. Uninstall the OA package of 9.14.2.0 or later version
  2. Downgrade the Dell Networking OS to an earlier version
  3. Install the respective OA package from an earlier version

For more information about installing, uninstalling and upgrading the Dell Networking OS and OA package, see the respective Dell System Release Notes.

  • If you downgrade the Dell Networking OS version from 9.14.2.14 to 9.11.0.0 or any older versions, the system displays the following error message even though there is no functional impact:

DELL S6100-ON Networking Switch - fig 2

Before downgrading, save the current configuration and then remove the CDB files ( c o n f d c d b . t a r . g z . v e r s i o n and c o n f d c d b . t a r . g z). To remove the files, use the following steps:

DELL S6100-ON Networking Switch - fig 3

  • In a VXLAN scenario, hybrid port is not supported.

  • While deploying the system in the normal-reload mode in BMP configuration, use the i p s s h s e r v e r e n a b l e command at the beginning of the startup configuration if the w r i t e m e m o r y command is used at the end of the configuration.

  • Do not configure the v x l a n – i n s t a n c e command on the port, which is configured with the p o r t m o d e h y b r i d command. Do not configure the vxlan-instance enabled port as a member of VLAN, which does not have VXLAN-VNI configuration.

  • File system partition:

    • The ONIE installer, of OS versions 9.10(0.1P9) and later, changes the file system partition scheme to facilitate the installation of certain third-party networking operating systems.
    • If you have installed Dell Networking OS using the O N I E i n s t a l l option, you cannot downgrade from Dell Networking OS 9.14(2.14) to versions earlier than 9.10(0.1P9), using the u p g r a d e s y s t e m command, due to file system partition compatibility issues.
      NOTE: The above restriction is not applicable if you have upgraded Dell Networking OS using the u p g r a d e s y s t e m command, instead of the O N I E i n s t a l l option.
  •  To downgrade Dell Networking OS version 9.14(2.14) to a version earlier than 9.10(0.1P9), follow these steps:
    1. From the ONIE menu, use the O N I E u n i n s t a l l option to uninstall Dell Networking OS 9.14(2.14).
    2. Use the O N I E i n s t a l l option to install the older version of Dell Networking OS.

  • To downgrade Dell Networking OS version 9.14(2.14) to a version earlier than 9.10(0.1P9), follow these steps:
    1. From the ONIE menu, use the O N I E u n i n s t a l l option to uninstall Dell Networking OS 9.14(2.14).
    2. Use the O N I E i n s t a l l option to install the older version of Dell Networking OS.

  • REST API does not support AAA authentication.

  • The systems shipped with OS 9.11(1.0) and above might contain one of the following chipsets:
    ○ BCM56960_B1 chipset with part number F6N2R or 6N1J1.
    ○ BCM56960_B0 chipset with part number KPX54 or H68CJ.
    You can check the part number using the s h o w i n v e n t o r y command.

  • In a system using BCM56960_B1 chipset, you cannot downgrade from Dell Networking OS 9.14(2.14) to OS versions earlier than 9.10(0.2), due to NPU compatibility issues.
    NOTE: The above restriction is not applicable for systems using BCM56960_B0 chipset.

  • You cannot use the e s t a b l i s h e d keyword in an ACL rule, along with the other control flags.

  • While using the e s t a b l i s h e d keyword in an ACL rule, all the other TCP control flags are masked, to avoid redundant TCP control flags configuration in a single rule. When you use any TCP control flag in an ACL rule, e s t a b l i s h e d is masked and
    other control flags are available.

  • DIAG version can also be 3.25.4.1

  • When FRRP is enabled in a VLT domain, no flavor of Spanning tree should concurrently be enabled on the nodes of that specific VLT domain. In essence FRRP and xSTP should not co-exist in a VLT environment.

  • The following features are not available in Dell Networking OS:

    • Protocol-independent multicast (PIM) equal cost multi path (ECMP)
    • Static Internet group management protocol (IGMP) join ( i p i g m p s t a t i c – g r o u p)
    • IGMP queried timeout configuration ( i p i g m p q u e r i e r – t i m e o u t)
    • IGMP group join limit ( i p i g m p g r o u p j o i n – l i m i t)
  • When 1024 or more VNI profiles are configured, the system takes more time to load. Dell recommends to restrict the VNI profiles to be less than 1000.

  • If you use the i n t e r f a c e r a n g e command to select multiple interfaces that are added to the management VRF, the i p v 6 a d d r e s s command does not display the a u t o c o n f i g option. You can configure the a u t o c o n f i g command on individual interfaces.

  • If you use the i n t e r f a c e r a n g e command to select multiple interfaces that are added to the management VRF, the i p v 6 n d command displays the following options but they do not take effect if you use them:

    • dns-server
    • hop-limit
    • managed-config-flag
    • max-ra-interval
    • mtu
    • other-config-flag
    • prefix
    • ra-guard
    • ra-lifetime
    • reachable-time
    • retrans-timer
    • suppress-none

Changes to the Default Behavior and CLI Syntax

The following behavior and CLI changes are applicable to the S6100-ON switch with Dell Networking OS version 9.14(2.14):
None.

Documentation Corrections

This section describes the errors that are identified in the current release of the Dell Networking OS.

  • The r o u t e r b g p command allows you to configure only one L3 interface with an IPv4 address. The Configuration guide does not mention this limitation and will be corrected in the next release of the guide.

Deferred Issues

Issues that appear here were reported in Dell Networking OS version 9.14(2.0) as open, but have since been deferred. Deferred caveats are those issues that are found to be invalid, not reproducible, or not scheduled for resolution.
Deferred issues are reported using the following definitions.

Category Description
PR# Problem Report number that identifies the issue.
Severity S1—Crash: A software crash occurs in the kernel or a running

process that requires a restart of AFM, the router, switch, or process.
S2—Critical: An issue that renders the system or a major feature unusable, which can have a pervasive impact on the system or network, and for which there is no work-around acceptable to the customer.
S3—Major: An issue that affects the functionality of a major feature or negatively effects the network for which there exists a work-around that is acceptable to the customer.
S4—Minor: A cosmetic issue or an issue in a minor feature with little or no network impact for which there might be a work-around.
Synopsis| Synopsis is the title or short description of the issue.
Release Notes| Release Notes description contains more detailed information about the issue.
Work around| Work around describes a mechanism for circumventing, avoiding, or recovering from the issue. It might not be a permanent solution.
Issues listed in the “Closed Caveats” section should not be present, and the work-around is unnecessary, as the version of code for which this release note is documented has resolved the caveat.

Deferred S6100-ON 9.14(2.0) Software Issues
Issues that appear in this section were reported in Dell Networking OS version 9.14(2.0) as open, but have since been deferred.
Deferred caveats are those that are found to be invalid, not reproducible, or not scheduled for resolution.
The following issues have been deferred in the Dell Networking OS version 9.14(2.0):
None.

Fixed Issues

Fixed issues are reported using the following definitions.

Category Description
PR# Problem Report number that identifies the issue.
Severity S1—Crash: A software crash occurs in the kernel or a running

process that requires a restart of AFM, the router, switch, or process.
S2—Critical: An issue that renders the system or a major feature unusable, which can have a pervasive impact on the system or network, and for which there is no work-around acceptable to the customer.
S3—Major: An issue that affects the functionality of a major feature or negatively effects the network for which there exists a work-around that is acceptable to the customer.
S4—Minor: A cosmetic issue or an issue in a minor feature with little or no network impact for which there might be a work-around.
Synopsis| Synopsis is the title or short description of the issue.
Release Notes| Release Notes description contains more detailed information about the issue.
Work around| Work around describes a mechanism for circumventing, avoiding, or recovering from the issue. It might not be a permanent solution.
Issues listed in the “Closed Caveats” section should not be present, and the work-around is unnecessary, as the version of code for which this release note is documented has resolved the caveat.

Fixed S6100-ON 9.14(2.14) Software Issues
NOTE: Dell Networking OS 9.14(2.14) includes fixes for caveats addressed in the previous 9.14 releases. See the respective release notes documentation for the list of caveats fixed in the earlier 9.14 releases.
The following caveats have been fixed in Dell Networking OS version 9.14(2.14):

PR# 170114

Severity:| Sev 2
Synopsis:| The switch experiences memory leaks when processing certain types of packets.
Release Notes:| The switch experiences memory leaks when processing certain types of packets.
Workaround:| None
PR# 170232|
Severity:| Sev 2
Synopsis:| The switch sends deprecated VRRP traps.
Release Notes:| The switch sends deprecated VRRP traps.
Workaround:| None
PR# 170301|
Severity:| Sev 3
Synopsis:| The B N m o d s q r t ( ) function, which computes a modular square root, contains a bug that can cause it to loop forever for non-prime moduli (CVE-2022-0778).
Release Notes:| The B N m o d s q r t ( ) function, which computes a modular square root, contains a bug that can cause it to loop forever for non- prime moduli (CVE-2022-0778).
Workaround:| None

Known Issues

Known issues are reported using the following definitions.

Category Description
PR# Problem Report number that identifies the issue.
Severity S1—Crash: A software crash occurs in the kernel or a running

process that requires a restart of AFM, the router, switch, or process.
S2—Critical: An issue that renders the system or a major feature unusable, which can have a pervasive impact on the system or network, and for which there is no work-around acceptable to the customer.
S3—Major: An issue that affects the functionality of a major feature or negatively effects the network for which there exists a work-around that is acceptable to the customer.
S4—Minor: A cosmetic issue or an issue in a minor feature with little or no network impact for which there might be a work-around.
Synopsis| Synopsis is the title or short description of the issue.
Release Notes| Release Notes description contains more detailed information about the issue.
Work around| Work around describes a mechanism for circumventing, avoiding, or recovering from the issue. It might not be a permanent solution.
Issues listed in the “Closed Caveats” section should not be present, and the work-around is unnecessary, as the version of code for which this release note is documented has resolved the caveat.

Known S6100–ON 9.14(2.14) Software Issues
The following caveats are open in Dell Networking OS version 9.14(2.14):
None.

Upgrading the ONIE Package for the S6100-ON System

  • Zero touch (dynamic): Copy the update ONIE installer for your system to the TFTP or HTTP server. Configure the
    DHCP options using the ONIE specifications shown at the following link: https://github.com/opencomputeproject/onie/wiki/Design-Spec-SW-Updating- ONIE.

  • Manual: Copy the image onto the TFTP or HTTP server and boot into ONIE. Update the ONIE using the o n i e – s e l f u p d a t e command, then download and run an ONIE updater image (onie-updater-x86_64-s6100_c2538-r0 ). The supported URL types are: HTTP, FTP, TFTP, and FILE.

To upgrade ONIE, perform the following steps:

  1. Reboot the system. During the reboot process, the system displays the following message prompting you to press the Esc key in order to stop the autoboot process:DELL S6100-ON Networking Switch - fig 4

  2. At this prompt message, press the Esc key. The following menu appears:DELL S6100-ON Networking Switch - fig 5

  3. From the menu, choose the O N I E option.
    NOTE: To choose an option from the menu, select one of the options using the up or down arrow key and press Enter.
    The following menu appears:DELL S6100-ON Networking Switch - fig
6

  4. From this menu, choose the O N I E : U p d a t e O N I E option.
    NOTE: To choose an option from the menu, select one of the options using the up or down arrow key and press Enter.
    The ONIE update mode is enabled and the ONIE prompt appears, as shown:DELL
S6100-ON Networking Switch - fig 7

  5. At the ONIE prompt, to stop the ONIE discovery process, enter the following command:
    O N I E : / # o n i e – d i s c o v e r y – s t o p
    The ONIE discovery stops, as shown:DELL S6100-ON Networking Switch - fig
8

  6. Configure an interface and assign an IP address to that interface using the following command:
    O N I E : / # i f c o n f i g e t h 0 1 0 . 1 6 . 1 2 9 . 1 3 1 / 1 6

  7. Enter the following command to upgrade ONIE: O N I E : / # o n i e – s e l f – u p d a t e t f t p : / / < t f t p – s e r v e r – a d d r e s s > / o n i e – u p d a t e r – x 8 6 6 4 – s 6 1 0 0 c 2 5 3 8 – r 0.
    NOTE: Copy the o n i e – u p d a t e r – x 8 6 6 4 – s 6 1 0 0 c 2 5 3 8 – r 0 file to the / t f t p b o o t folder in the server.
    ONIE is updated on the system, as shown:

DELL S6100-ON Networking Switch - fig 9

Upgrading the DIAG Package for the S6100-ON System

To upgrade the DIAG package, use one of the following two processes:

  •  Zero touch (dynamic): Copy the update ONIE installer for your system to the TFTP or HTTP server. Configure the
    DHCP options using the ONIE specifications shown at the following link: https://github.com/opencomputeproject/onie/wiki/Design-Spec-SW-Updating- ONIE.

  • Manual: Copy the image onto the TFTP or HTTP server and boot ONIE. Update the ONIE using the o n i e – s e l f u p d a t e command, then download and run an ONIE updater image ( d i a g – i n s t a l l e r – x 8 6 6 4 – d e l l s 6 1 0 0 _ c 2 5 3 8 r 0 . 3 . 2 5 . 4 . 1 . b i n). The supported URL types are: HTTP, FTP, TFTP, and FILE.
    NOTE: If Dell Networking OS is already installed on the S6100-ON system, before upgrading the DIAG package, you must first uninstall Dell Networking OS. For more information about uninstalling Dell Networking OS, see Uninstalling Dell Networking OS on the S6100-ON.

To upgrade DIAG, perform the following steps:

  1. Reboot the system. During the reboot process, the system displays the following message prompting you to press the Esc key in order to stop the autoboot process:DELL S6100-ON Networking Switch - fig 10

  2. At this prompt message, press the Esc key. The following menu appears:DELL S6100-ON Networking Switch - fig 11

  3. From the menu, choose the O N I E option.
    NOTE: To choose an option from the menu, select one of the options using the up or down arrow key and press Enter.
    The following menu appears:DELL S6100-ON Networking Switch - fig
12

  4. From this menu, choose the O N I E : I n s t a l l O S option.
    NOTE: To choose an option from the menu, select one of the options using the up or down arrow key and press Enter.
    The ONIE Installer mode is enabled and the ONIE prompt appears, as shown:DELL S6100-ON Networking Switch - fig 13

  5. At the ONIE prompt, to stop the ONIE discovery process, enter the following command:
    O N I E : / # o n i e – d i s c o v e r y – s t o p
    The ONIE discovery stops, as shown:DELL S6100-ON Networking Switch - fig
14

  6. Configure an interface and assign an IP address to that interface using the following command: O N I E : / # i f c o n f i g e t h 0 1 0 . 1 6 . 1 2 9 . 1 3 1 / 1 6

  7. Enter the following command to upgrade DIAG on the S6100–ON system: o n i e – n o s – i n s t a l l f t p : / / f t p : f t p @ < f t p s e r v e r – a d r e s s > / t f t p b o o t / d i a g – i n s t a l l e r – x 8 6 6 4 – d e l l s 6 1 0 0 c 2 5 3 8 – r 0 . 3 . 2 5 . 4 . 1 . b i n
    NOTE: Copy the d i a g – i n s t a l l e r – x 8 6
    6 4 – d e l l s 6 1 0 0 c 2 5 3 8 – r 0 . 3 . 2 5 . 4 . 1 . b i n file to the / t f t p b o o t folder in the server.
    The DIAG is updated on the system, as shown:

DELL S6100-ON Networking Switch - fig 15DELL
S6100-ON Networking Switch - fig 16

Installing Dell Networking OS on the S6100-ON using ONIE

NOTE: You will need the Dell Networking OS installer package, O N I E – F T O S – S 6 1 0 0 – O N – 9 . 1 4 . 2 . 1 4 . b i n to install the Dell Networking OS on your S6100-ON system that has only ONIE.
To install the Dell Networking OS version 9.14(2.14) on a new S6100-ON device, perform the following steps:

  1. Reboot the system. During the reboot process, the system displays the following message prompting you to press the Esc key in order to stop the autoboot process:DELL S6100-ON Networking Switch - fig 17

  2.  At this prompt message, press the Esc key. The following menu appears:DELL S6100-ON Networking Switch - fig 18

  3. From the menu, choose the O N I E option.
    NOTE: To choose an option from the menu, highlight one of the options using the up or down arrow key and press Enter.
    The following menu appears:DELL S6100-ON Networking Switch - fig
19

  4. From this menu, choose the O N I E : I n s t a l l O S option.
    NOTE: To choose an option from the menu, highlight one of the options using the up or down arrow key and press Enter.
    The ONIE Installer mode is enabled and the ONIE prompt appears, as shown:DELL S6100-ON Networking Switch - fig 20

  5. At the ONIE prompt, to stop the ONIE discovery process, enter the following command:
    O N I E : / # o n i e – d i s c o v e r y – s t o p
    The ONIE discovery stops, as shown:DELL S6100-ON Networking Switch - fig
21

  6. Configure an interface and assign an IP address to that interface using the following command:
    O N I E : / # i f c o n f i g e t h 0 1 0 . 1 6 . 1 2 9 . 1 3 1 / 1 6

  7. Enter the following command to begin the installation process:DELL S6100-ON Networking Switch - fig 22 NOTE: You must copy the F T O S – S 6 1 0 0 – O N – 9 . 1 4 . 2 . 1 4 . b i n file to the / t f t p b o o t folder in the server
    NOTE: After the Dell Networking OS installation completes, the system automatically reboots.
    Following is the installation and boot log of Dell Networking OS:DELL
S6100-ON Networking Switch - fig 23

  8. After the installation completes, the system displays the following DELL prompt:
    D e l l E M C #

Upgrading the S6100-ON Dell Networking OS Image using Dell Networking OS

CLI

Bare Metal Provisioning
NOTE: If you are using Bare Metal Provisioning (BMP), see the Bare Metal Provisioning topic in the Dell Networking OS Configuration Guide or the Open Automation Guide.
Manual Upgrade Procedure
The ONIE installer, of OS versions 9.10(0.1P9) and later, changes the file system partition scheme to facilitate the installation of certain third-party networking operating systems.
If you have installed Dell Networking OS using the O N I E i n s t a l l option, you cannot downgrade from Dell Networking OS
9.14(2.14) to versions earlier than 9.10(0.1P9), using the u p g r a d e s y s t e m command, due to file system partition compatibility issues. If you try to downgrade, the system displays the following error message:

DELL S6100-ON Networking Switch - fig 24

To downgrade Dell Networking OS version 9.14(2.14) to versions earlier than 9.10(0.1P9), follow these steps:

  1. From the ONIE menu, use the O N I E u n i n s t a l l option to uninstall Dell Networking OS 9.14(2.14).
  2. Use the O N I E i n s t a l l option to install the older version of Dell Networking OS.

You can upgrade or downgrade to any version, if you have upgraded Dell Networking OS using the u p g r a d e s y s t e m command, instead of the O N I E i n s t a l l option.
The systems shipped with OS 9.14(2.14) and above might contain one of the following chipsets:

  • BCM56960_B1 chipset with part number F6N2R or 6N1J1.
  • BCM56960_B0 chipset with part number KPX54 or H68CJ.

You can check the part number using the s h o w i n v e n t o r y command
In a system using BCM56960_B1 chipset, you cannot downgrade from Dell Networking OS 9.14(2.14) to OS versions earlier than 9.10(0.2), due to NPU compatibility issues.
In a system using BCM56960_B1 chipset, if you try to downgrade from OS 9.14(2.14) to OS versions earlier than 9.10(0.2) using BMP or the u p g r a d e command, the system displays the following error message:

DELL S6100-ON Networking Switch - fig 25

You can upgrade or downgrade the OS to any version in systems using BCM56960_B0 chipset.
Follow these steps carefully to upgrade your S6100-ON systems:

  1. Cancel BMP and disable BMP from the next reload:DELL S6100-ON Networking Switch - fig 26

  2. Dell Networking recommends that you back up your startup configuration and any important files and directories to an external media prior to upgrading the system.

  3. Upgrade the Dell Networking OS in flash partition A: or B:
    EXEC Privilege Mode
    u p g r a d e s y s t e m [ f l a s h : | f t p : s t a c k – u n i t < i d > | t f t p : | s c p : | u s b f l a s h : ] [ A : | B : ]DELL S6100-ON
Networking Switch - fig 27

  4. Verify that the Dell Networking OS has been upgraded correctly in the upgraded flash partition EXEC Privilege Mode
    s h o w b o o t s y s t e m s t a c k – u n i t 1 | a l l ]DELL S6100-ON
Networking Switch - fig 28

  5. Change the Primary Boot Parameter of the S6100-ON to the upgraded partition A: or B:
    CONFIGURATION Mode
    b o o t s y s t e m s t a c k – u n i t 1 p r i m a r y s y s t e m : [ A : | B : | t f t p : | f t p : ]

  6. Save the configuration so that the configuration will be retained after a reload using the w r i t e m e m o r y command.
    EXEC Privilege Mode
    w r i t e m e m o r yDELL S6100-ON Networking Switch - fig
29

  7. Reload the unit.
    EXEC Privilege Mode
    r e l o a dDELL S6100-ON Networking Switch - fig 30

  8. Verify the S6100–ON has been upgraded to the Dell Networking OS version 9.14(2.14).
    EXEC Privilege Mode
    s h o w v e r s i o nDELL S6100-ON Networking Switch - fig
31

Upgrade the Boot Selector and Boot Flash Images from Dell Networking OS

To upgrade the Boot Selector and Boot Flash images from Dell Networking OS, perform the following steps:

  1. Upgrade the S6100-ON Boot Selector image.
    EXEC Privilege Mode
    u p g r a d e b o o t b o o t s e l e c t o r – i m a g e s t a c k – u n i t [ < i d > | a l l ] [ b o o t e d ] To upgrade the Boot Selector image to the image version packed with the loaded Dell Networking OS image, use the booted option. You can find the Boot Selector image version packed with the loaded Dell Networking OS using the s h o w o s – v e r s i o n command in EXEC Privilege mode.DELL S6100-ON Networking Switch - fig
32

  2. Reload the unit.
    EXEC Privilege Mode
    r e l o a d

  3. Upgrade the Dell Networking OS GRUB.
    EXEC Privilege Mode
    u p g r a d e b o o t b o o t f l a s h – i m a g e s t a c k – u n i t < s t a c k – u n i t – i d > b o o t e dDELL S6100-ON Networking Switch - fig
33

  4. Reload the unit.
    EXEC Privilege Mode
    r e l o a d

  5. Verify whether the upgrade is successful.DELL S6100-ON Networking Switch - fig 34DELL S6100-ON Networking Switch - fig 35

  6. After you upgrade Dell Networking Networking OS to 9.14(2.14) from an earlier version and update the BIOS using the booted option, the system does not allow you to downgrade the BIOS to an earlier version. To run an earlier BIOS versionuse FTP, TFTP, or SCP option from the current OS version.DELL S6100-ON Networking Switch - fig 36

Upgrade the CPLD Images

On the S6100–ON, you must upgrade the switchyard, CXP, 40G, and 100G CPLD images separately.
NOTE: If your CPLD revisions are higher than the ones shown here, DO NOT make any changes. If you have questions regarding the CPLD revision, contact Technical Support.
Verify that you need a CPLD upgrade
To identify the CPLD version, use the show revision command.

DELL S6100-ON Networking Switch - fig 37

To view the CPLD version that is associated with the Dell Networking OS image, use the following command:

DELL S6100-ON Networking Switch - fig 38

Upgrading the Switchyard-CPLD Image
The S6100-ON system with Dell Networking OS Version 9.14(2.14) requires switchyard- cpld image 5.
NOTE: The u p g r a d e f p g a – i m a g e s w i t c h c a r d – c p l d s t a c k – u n i t 1 b o o t e d command is hidden when using the feature in the CLI. However, it is a supported command. The mod-id option represents the ID of the module slot on the S6100–ON.
NOTE: Ensure that the BIOS version is 3.25.0.0-6. You can verify this version using the s h o w s y s t e m s t a c k – u n i t 1 command.
To upgrade the CPLD image, follow these steps.

  1. Upgrade the switchyard-CPLD image.
    EXEC Privilege Mode
    u p g r a d e f p g a – i m a g e s w i t c h c a r d – c p l d s t a c k – u n i t < 1 > b o o t e dDELL S6100-ON Networking Switch - fig
39DELL S6100-ON Networking Switch - fig
40

Upgrading the CXP Module CPLD image
The S6100-ON system with Dell Networking OS Version 9.14(2.14) requires CXP MODULE CPLD image 5. To display the CXP module CPLD version currently running on an S6100-ON, use the s h o w r e v i s i o n command.
NOTE: The u p g r a d e f p g a – i m a g e m o d – i d s t a c k – u n i t 1 b o o t e d command is hidden when using the feature in the CLI. However, it is a supported command. The mod-id option represents the ID of the module slot on the S6100–ON.
To upgrade the CPLD image, follow these steps.

  1. Upgrade the CXP module CPLD image.
    EXEC Privilege Mode
    u p g r a d e f p g a – i m a g e m o d – i d s t a c k – u n i t 1 b o o t e d
    NOTE: In this example, the CXP Module is in slot 2.

DELL S6100-ON Networking Switch - fig 41

Upgrading the 40G Module CPLD image
The S6100-ON system with Dell Networking OS Version 9.14(2.14) requires 40G MODULE CPLD image 12. To display the 40G module CPLD version currently running on an S6100-ON, use the s h o w r e v i s i o n command.
NOTE: The u p g r a d e f p g a – i m a g e m o d – i d s t a c k – u n i t 1 b o o t e d command is hidden when using the feature in the CLI. However, it is a supported command. The mod-id option represents the ID of the module slot on the S6100–ON.
Upgrade the 40G module CPLD image.

  1. Upgrade the 40G module CPLD image.
    EXEC Privilege Mode
    u p g r a d e f p g a – i m a g e m o d – i d s t a c k – u n i t 1 b o o t e d
    NOTE: In this example, the 40G Module is in slot 3.

DELL S6100-ON Networking Switch - fig 42DELL
S6100-ON Networking Switch - fig 43

Upgrading the 100G Module CPLD image
The S6100-ON system with Dell Networking OS Version 9.14(2.14) requires 100G QSFP28 module CPLD image 4. To display the 100G QSFP28 module CPLD version currently running on an S6100-ON, use the s h o w r e v i s i o n command.
NOTE: The u p g r a d e f p g a – i m a g e m o d – i d s t a c k – u n i t 1 b o o t e d command is hidden when using the feature in the CLI. However, it is a supported command. The mod-id option represents the ID of the module slot on the S6100–ON.
To upgrade the CPLD image, follow these steps.

  1. Upgrade the 100G module CPLD image.
    EXEC Privilege Mode
    u p g r a d e f p g a – i m a g e m o d – i d s t a c k – u n i t 1 b o o t e d
    NOTE: In this example, the 100G Module is in slot 4.

DELL S6100-ON Networking Switch - fig 44

Upgrading the Smart Fusion Microcontroller Subsystem — SMF MSS-IAP

The S6100-ON system with Dell Networking OS Version 9.14(2.14) requires mess- up image 2.4.
To upgrade the Smart Fusion Microcontroller Subsystem — SMF MSS-IAP, follow these steps:

  1. Upgrade the SMF MSS-IAP image.
    EXEC Privilege Mode
    u p g r a d e m s s – i a p – i m a g e s t a c k – u n i t < s t a c k – u n i t – i d > b o o t e dDELL S6100-ON Networking Switch - fig
45

Upgrading the Smart Fusion Microcontroller Subsystem — SMF MSS-FPGA

The S6100-ON system with Dell Networking OS Version 9.14(2.14) requires mss- fpga image 1.1.
NOTE: Before upgrading the Smart Fusion Microcontroller Subsystem SMF MSS-FPGA, you must first upgrade the SMF MSS-IAP.
To upgrade the Smart Fusion Microcontroller Subsystem — SMF MSS-FPGA, follow these steps:

  1. Upgrade the SMF MSS-FPGA image.
    EXEC Privilege Mode
    u p g r a d e m s s – f p g a – i m a g e s t a c k – u n i t < s t a c k – u n i t – i d > b o o t e d

DELL S6100-ON Networking Switch - fig 46

NOTE: Although the system displays that the system power cycles automatically after the upgrade, the system may not power cycle. If the system does not power cycle automatically, wait for at least five minutes and power cycle the system by switching off and switching on the system.

Upgrading the OOB-FPGA Image

The S6100-ON system with Dell Networking OS Version 9.14(2.14) requires oob- fpga image 1.0.
To upgrade the OOB-FPGA, follow these steps:

  1. Upgrade the OOB-FPGA image.
    EXEC Privilege Mode
    u p g r a d e f p g a – i m a g e s y s t e m f p g a s t a c k – u n i t < s t a c k – u n i t – i d > b o o t e dDELL S6100-ON Networking Switch - fig
47DELL S6100-ON Networking Switch - fig
48

Uninstalling the Dell Networking OS

To uninstall the Dell Networking OS version 9.14(2.14) from your S6100-ON system, perform the following steps:

  1. Reboot the system. During the reboot process, the system displays the following message prompting you to press the Esc key in order to stop the auto-boot process:DELL S6100-ON Networking Switch - fig 49

  2. At this prompt message, press the Esc key. The following menu appears:DELL S6100-ON Networking Switch - fig 50

  3. From the menu, choose the O N I E option.
    NOTE: To choose an option from the menu, highlight one of the options using the up or down arrow key and press Enter.
    The following menu appears:DELL S6100-ON Networking Switch - fig
51

  4. From this menu, choose the O N I E : U n i n s t a l l O S option.
    NOTE: To choose an option from the menu, highlight one of the options using the up or down arrow key and press Enter.
    The uninstall process begins, as shown:DELL S6100-ON Networking Switch - fig
52DELL S6100-ON Networking Switch - fig
53DELL S6100-ON Networking Switch - fig
54

  5. After the installation completes, the system displays the following ONIE prompt:
    O N I E : / #

Installing a Third Party Operating System

Apart from the Dell Networking OS, you can also install a supported third party operating system on the S6100-ON system. For more information on installing a third party operating system, refer to the third party OS vendor’s website for OS installation instructions.

Contacting Dell

NOTE: If you do not have an active Internet connection, you can find contact information on your purchase invoice, packing slip, bill, or Dell product catalog.
Dell provides several online and telephone-based support and service options. Availability varies by country and product, and some services may not be available in your area. To contact Dell for sales, technical support, or customer service issues:
Go to www.dell.com/support.
Notes, cautions, and warnings
NOTE: A NOTE indicates important information that helps you make better use of your product.
CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.
WARNING: A WARNING indicates a potential for property damage, personal injury, or death.

DELL logo© 2022 Dell Inc. or its subsidiaries.