AIR SENSE 9-30782 Command Display Module Instruction Manual

September 3, 2024
AIR SENSE

9-30782 Command Display Module

“`html

Specifications

  • Product Name: AirSense ModuLaser Command Display Module
  • Model Number: 9-30782

Product Information

The AirSense ModuLaser Command Display Module is a part of a
scalable aspirating smoke detection solution that offers advanced
features for installation, maintenance, and application
flexibility. It consists of a TFT color display, navigation
buttons, and status LED’s for user interaction.

General Overview

The ModuLaser solution includes two basic module types: display
modules and detector modules. Each detector module can accommodate
up to 250 meters of combined sampling pipe. Communication between
display modules and detector modules is achieved through RS-485
interconnections.

Display Module Configurations

Display modules are available in three configurations:

  • Standard: TFT color display, status LED’s, and navigation
    buttons

  • Minimum: Only status LED’s

  • Command: Similar to the Standard with added functionality to
    control various modules over SenseNET

Product Usage Instructions

Configuration and Control

The Command Display Module can be configured and controlled via
the user interface, or remotely using computer software. The TFT
color display allows for simple operations like changing
configuration options through a menu-driven structure and advanced
features like viewing chart recordings graphically.

Network Support

The Command Display Module supports up to 127 modules across the
SenseNET network, which can be a combination of ModuLaser modules,
Micra’s, and HSSD2’s. It serves as a central point for accessing
all modules/detectors on the network and reporting alarms and
faults.

Environmental Adaptability

The ModuLaser system is designed to be impervious to dust and
dirt, making it suitable for hostile environments. Forward
scattering optical detection provides early warning capability
without nuisance alarms, and environmental compensation technology
enhances reliability.

FAQ

Q: What is the detection principle of the Command Display

Module?

A: The Command Display Module utilizes laser light scattering
mass detection and particle evaluation for effective smoke
detection.

“`

9-30782
AirSense ModuLaser, Command display module

General
ModuLaser is a scalable aspirating smoke detection solution that makes installation easier, maintenance quicker, and takes applications further than traditional air sampling detectors. Two basic module types comprise the ModuLaser solution: a display module, and a detector module. Each detector module can accommodate up to 250 meters combined sampling pipe. Display modules and detector modules communicate by RS-485 interconnections.
Display modules are available in three configurations: Standard with TFT color display, status LED’s and navigation buttons, Minimum with only status LED’s, and Command which is similar to the Standard but with the added functionality to control various modules over SenseNET. The Minimum and Standard Display Modules can each support up to 8 detector modules, while the Command Display Module can support up to 127 modules across the SenseNET network.
Command display module
The Command Display Module features a user interface which consist of a TFT color display, navigation buttons and status LED’s. Configuration of the Command Display Module (and associated detectors across the SenseNET network ) can be done via the user interface, or via a computer using Remote software. The TFT color display support simple operations like changing configuration options via a menu driven structure, but also advanced features like viewing the chart recording in graphical format.
The Command Display Module support up to 127 modules across the SenetNET network. The 127 modules can be any combination of ModuLaser modules as well as Micra’s and HSSD2’s. The use of the Command Display Module creates an easy to use central point from where all modules/detector on the network can be accessed, and all alarms and faults are reported.
Perfect solution
Thanks to advanced features that make it virtually impervious to dust and dirt, ModuLaser is ideal for use in hostile environments that would disable other kinds of smoke detectors. Forward scattering optical detection adds early warning capability without the risk of nuisance alarms normally associated with high sensitivity smoke detection, while exclusive environmental compensation technology adds a high degree of reliability to an already solid detection solution.

Details
Modular Design : Separate centrally-controllable detector modules allow efficient piping and discrete zones with no overlap. Zoned aspirating smoke detection : Individual detector modules provide detection for individual areas or zones, specific zone alarm information can be transmitted to the main fire alarm panel via a common APIC address card in the display module or through dedicated alarm relays within each detector module. Simplified installation : Ingenious docking station design allows detectors to be easily connected together as a group. Sensitive electronics are easily removed to ensure they will not be damaged during first fix installation. Aspirating pipework and cable entries can easily be made into either the top or the bottom of the unit. Intuitive user interface : Bright easy-to-see color TFT display and universal navigation and control buttons take the guesswork out of programming and diagnostics. Easy pipe connection : The quick fit pipe adaptor system locks down securely, yet leaves plenty of room for easy pipe connection and removal. Quick location of smoke : Each detector module is self-contained, which means no delays in determining in which zone (sampling pipe) smoke is present.

9-30782
AirSense ModuLaser, Command display module Technical specifications

General
Status indication User interface
Alarm levels Event log RS485 support Connectivity

LED’s TFT and navigation buttons on Normal and Command Display Modules 4 (Aux, Pre-alarm, Alarm and Alarm 2) 20 000 events per module Yes (SenseNET and SenseNET+) USB (x2), IP and APIC on Display Module, with Modbus on Command Display Module

Electrical
Operating voltage Current consumption

18 to 30 VDC
Display Module (at 24 VDC): 204 mA – Minimum Display Module 232 mA – Standard Display Module 232 mA – Command Display Module Detector Module (at 24 VDC): 260 mA – fan speed 1 380 mA – fan speed 6 (default speed) 940 mA – fan speed 16

Detection

Detection principle

Laser light scattering mass detection and particle evaluation

Particle sensitivity range 0.003 to 10 microns

Sampling pipe

Length

Up to 250 m (820 ft.) combined per detector module

Quantity sampling holes Up to 20 – Class A per detector module Up to 40 – Class B per detector module Up to 50 – Class C per detector module

Inlet size

27 or 25 mm (1.06 or 0.98 in) outer diameter

Inlet location

Top or bottom

Exhaust size

27 or 25 mm (1.06 or 0.98 in) outer diameter

Exhaust location

Top or bottom

Inlet quantity

1 per detector module

Input
Input quantity Input type and rating Termination Programmable

2 per module Supervised 15 K 5% 1/4 W Yes

Output

Output quantity Output type and rating
Programmable

3 per module Voltage free (contact rating 2 A at 30 VDC / NO/NC/C) Yes

Physical
Physical dimensions
Net weight
Colour Mounting type Cable entries
Cable entry size Detector module orientation

W x D x H 110.5 x 133.5 x 300 mm (4.35 x 5.25 x 11.8 in)
Display Module: 1.18 Kg (2.6 lb.) Detector Module: 1.57 Kg (3.46 lb.)
Cream
Surface mount
2 at the bottom, 2 at the rear, 2 at the top on Detector Module, and 3 at the top on the Display Module
20 mm (0.5 in) – top and bottom
Vertical (0 deg or 180 deg)

Environmental

Operating temperature
Relative humidity Environment

Equipment: -20 to +60 °C (-4 to +140 °F) Sampled air: -20 to +60 °C (-4 to +140 °F)
0 to 95% noncondensing
Indoor

IP rating

IP40

Regulatory
Compliancy Certification

REACH, RoHS BOSEC, CPR, CSIRO, EN54-20, LPCB, VdS

Chart recorder
Sampling period Capacity Values recorded

Adjustable between 1s and 60 s 1 months @ 1s / Up to 5 years @ 60 s Detector value, 4 alarm level values, flow value and temperature (all simultaneously)

Compatible products

Category
Detection device
Detection device
Detection device

Reference 9-30780
9-30781
9-30783

Description AirSense ModuLaser, Minimum Display Module AirSense ModuLaser, Standard display module AirSense ModuLaser, Detector module

Powered by TCPDF (www.tcpdf.org)

As a company of innovation, Carrier Fire & Security reserves the right to change product specifications without notice. For the latest product specifications, visit firesecurityproducts.com online or contact your sales representative.
Last updated on 15 February 2024 – 9:40

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals