** Please read the instructions carefully before starting the machine.
STARTING-UP THE MACHINE**
Cleaning / Maintenance
|
---|---
|
|
|
|
|
|
Technical Data
Art. No…………50008 …… ………50016 ….. …………..50018
Service connection …………. 4000 V~50 Hz ……………230 V~50 Hz …………..400 V~50 Hz
Motor output S3/ 60% ….2,2 kW ………………….2,2 kW ……………..2,2 kw
Number of cylinders… ………….. 2………… ………2 …………………….2
Suction capacity …………………490 l/min ……………..320 l/min ……………….435 l/min
Free air delivery…………………….325 l/min …………..250 l/min ………………..302 l/min
Max. working pressure ……………… 10 bar …………………. 10 bar …………………… 10 bar
tank capacity ………………………50 l ……………………50 l …………………50 l
weight ……………………62 kg ……………….48 kg ……………… 59 kg
Degree of protection……………… IP 20 ………. IP 54 ………………… IP 54
Protection class ……………………….. 1 ………………….1 ………………….1
Sound power level LwA* …………………96 db(A) …………………..96 db(A) …………… 97 db(A)
Measured according to 2005/88/EC
Compressor………………..415/10/50 N………………….420/10/100 EU 230V0…………….580/10/100 EU
400V
Art. No …………………….50053 ………………..50071 …………50073
Service connection …………….230 V~50 Hz ………..230 V~50 Hz ………..400 V~50 Hz
Motor output S3/ 60% …………..2,2 kw ……………2,2 kw …………………….3,0 kw
Number of cylinders ………………….. 2 ……………………..2 …………………….2
Suction capacity………………..435 l/min …………..320 l/min …………………….480 l/min
Free air delivery….. ……….302 l/min ………….250 l/min …………..400 l/min
Max. working pressure ……………. 10 bar ……………… 10 bar ………………….. 10 bar
tank capacity ………………….50 l ……………………. 100 l ……………….. 100 l
weight …………………..63 kg …………………60 kg ………………. 79 kg
Degree of protection……………. IP 20 …………………….. IP 54 ……………………. IP 54
Protection class ………………….. 1 ……………………1 ………………………..1
Sound power level LwA ……………….96 dB(A) …………………..96 dB(A) ………….. 97 dB(A)
*Measured according to 2005/88/EC
** Read and understand the operating instructions before using the
appliance. Abide by all the safety measures stated in the service manual. Act
responsibly toward third parties. In case of any doubts about connection and
operation refer please to our customer center Preserve all the documentation
so that anyone who uses the compressor can consult this beforehand.
Specified Conditions Of Use**
The compressor may only be used to produce compressed air at home, on yards
and in workshops. The compressed air produced by the compressor can not be
used for pharmaceutical, food or medical purposes or to fill the air bottles
of scuba divers.
The compressor must be used in a suitable environment (well-ventilated with an
ambient temperature of between +5°C and +40°C) and never in places with dust,
acids, vapors, or explosive or flammable gases. Do not use this product in any
other way as stated for normal use. Not observing general regulations in force
and instructions from this manual does not make the manufacturer liable for
damages.
Safety instructions
WARNING! Electric shock! There is a risk of an injury caused by electric
shock!
Operation is only allowed with a safety switch against stray current (RCD max.
stray current of 30mA). Check the voltage. Technical data given on the type
label must correspond with the electric network voltage. Insert the plug of
the electrical cable in a socket of suitable shape, voltage and frequency
complying with current regulations. Use extension cables with a maximum length
of 5 meters and with a cable cross-section of not less than 1.5 mm2. Use of
extension cables of different lengths and cross-sections and also of adapters
and multiple sockets should be avoided. Check the cable and/or socket for
damages before the appliance putting into operation.
To avoid danger, a damaged mains supply pipe must be replaced by the
manufacturer. Do not under any circumstances attempt any repair yourself.
Never let the compressor come into contact with water or other liquids and
never direct the jet of liquids sprayed by tools connected to the compressor
towards the compressor: as the appliance is live, this could cause
electrocution or short-circuits. Never use the appliance with bare feet or wet
hands or feet. Never yank the power cable to disconnect the plug from the
power outlet or to move the compressor. warning: the compressor may restart
when power is restored following a blackout.
Compressed air is a potentially dangerous form of energy; always take great
care when using the compressor and its accessories.
This device is not intended for use by persons (including children) with
limited physical, sensory or mental capabilities or without the necessary lack
of experience or knowledge unless they are supervised by a person who is
responsible for their safety or was instructed by that person in how to use
the device. Children should be supervised to ensure that they do not play with
the device. Always keep children and unauthorized persons out of reach of the
appliance. Never use the compressor without being supervised. Never direct the
jet of air towards persons, animals, or your body. Never keep the airflow in
body holes as that could lead to fatal injuries!
Keep the work area free. when operating, the compressor must be placed on a
stable surface. Caution! The compressor may only be used with appropriate
wheels and rubber bumps. Safety goggles should be worn when using the
compressor in order to protect the eyes against any foreign bodies lifted by
the jet of air. If possible, when using air-powered accessories, wear safety
clothing. Always maintain a safe distance of at least 4 meters between the
compressor and the work area. Caution! The pneumatic hose may lash you when
the quick-acting coupling is opened! The pneumatic hose should be held by
hand. Always use the handle to move the compressor.
when using compressed air, you must know and comply with the safety
precautions to be adopted for each type of application (inflation, air-powered
tools, painting, washing with water-based detergents only, clinching, etc.).
when using compressed air, you must know and comply with the safety
precautions to be adopted for each type of application (inflation, air-powered
tools, painting, washing with water-based detergents only, clinching, etc.).
Caution! Never switch the compressor on or off using the plug. Pressure
switch to be pressed at all times. Do not leave the compressor on overnight as
it could become a source of danger. At the end of your working day, switch the
appliance off, release the air jet and unplug the compressor. warning: if the
water that condenses is not drained, it may corrode the receiver, reducing its
capacity and impairing safety.
Never leave the appliance exposed to adverse weather conditions (rain, sun,
fog, snow). If this compressor is used outdoors, always remember to stow it
after use in a covered or closed place. Never use the compressor outdoors in
rain or bad weather.
Do not place flammable or nylon/fabric objects close to and/or on the
compressor. Do not cover the air inlets on the compressor. The compressor must
not be fitted in a vehicle for industrial purposes without an inspection by an
expert! If the compressor is used for industrial purposes, it must be checked
by an expert before putting into operation for the first time. Such check must
be ordered by the operator (under betrSichV Section 17 No. 25 – operation
safety regulation)
Caution! when fitted in automatic equipment, it is necessary to install
an appropriate alarm or warning device in case of a power outage or
malfunction or compressor (e.g. feed line, etc.) failure.
Requirements for operating staff
To guarantee perfect and reliable operation of the rotary and percussive
pneumatic tools such as impact wrenches, staplers or nailers, etc., the
compressed air must be supplied filtered – with oil via the lubricator or
maintenance unit A filtered water separator should be used varnishing in any
case.
To select a suitable pneumatic tool, the tool air consumption and the
compressor effective amount delivered must necessarily be considered.
(Pneumatic tools and accessory equipment can be found at
www.guede.com)
Operation at lower temperatures
below 5°C, problems may be experienced when starting. They are manifested by
the growling of the electric motor. In such a case, the appliance must be
immediately switched off and the oil (5w30) changed in warmer conditions.
Requirements for operating staff The operating staff must carefully read the
Operating Instructions before using the appliance. qualification: Apart from
the detailed instructions by a professional, no special qualification is
necessary for appliance use. Minimum age: Persons over 16 years of age can
only work on the appliance. An exception includes youngsters trained in order
to reach knowledge under the supervision of the trainer during occupational
education. Training: Using the appliance only requires corresponding training
by a professional or the Operating Instructions. No special training is
necessary.
Emergency procedure
Conduct a first-aid procedure adequate to the injury and summon qualified medical attendance as quickly as possible. Protect the injured person from further harm and calm them down. For the sake of an eventual accident, in accordance with DIN 13164, a workplace has to be fitted with a first-aid kit. It is essential to replace any used material in the first-aid kit immediately after it has been used. If you seek help, state the following pieces of info motion:
- Accident site
- Accident type
- Number of injured persons
- Injury type(s)
Maintenance
Before carrying out any work on the machine, disconnect the plug from the
socket. Run the accessory connected dry until there is no more air in the
receiver.
Prior to every use, visually check the machine to rule out any defects, in
particular on the power cable and the plug. Safety valve Functional check. The
machine must not be used under any circumstances if the machine or the safety
devices are damaged.
Use only original accessories and original spare parts. Never clean the
machine and its components with solvents, flammable or toxic liquids. Use only
a damp cloth making. Only a regularly maintained and treated appliance can
serve as a satisfactory aid. Insufficient maintenance and care can lead to
unforeseen accidents and injuries. If necessary, a list of spare parts can be
found at www.guede.com.
Guarantee
the warranty period of 12 months applies to commercial use and 24 months
applies to private use and commences on the day of purchase of the device. The
guarantee solely covers inadequacies caused by a material defect or
manufacturing defects. An original payment voucher with the date of the sale
needs to be submitted for any claim in the guarantee period. The guarantee
does not cover any unauthorized use such as appliance overloading, use of
violence, or damage as a result of any unauthorized interference caused by
foreign items. Failing to follow the operating and assembly instructions and
common wear are also not included in the guarantee.
Service
Do you have any technical questions? Any claim? Do you need any spare parts
or operating instructions? we will quickly help you without needles
bureaucracy at our web pages at www.guede.com in the
Servicing part. Please help us be able to help you. In order to identify your
device in case of claim we need the serial No., product No. and year of
production. All this data can be found on the type label. Please enter it here
for future reference:
Serial No:………………………
Art. No:………………………..
Year of production:………
Symbols
Read the Operating Instructions
wear ear protectors! and wear eye protective goggles!
Protect against humidity Never expose the tool to rain.
Cable pulling/transport prohibited
warning/caution
Dangerous voltage
**** Caution – hot surface!The danger of burns!
Danger – automatic control (closed loop).
Any damaged or disposed of electric or electronic devices must be delivered to
appropriate collection centers.
Protect against humidity
This side up.
Failure removal
Failures | Causes | Removal |
---|---|---|
The compressor not starting after being switched on | Pressure in the air jet | |
exceeds the closing pressure | Release the pressure in the air jet so that the |
pressure switch gets automatically switched on
Defective supply| Have the current supply checked by an authorized person
Defective pressure switch| Have the pressure switch replaced by an authorized
person (Güde service center)
Worn carbons| Replace the carbons
After reaching the closed pressure, the compressor runs or buzzes for a short
time and then switches off automatically| Electric cable is too long or its
cross-section is too small| Check the length and cross-section of the electric
cable
Compressor running constantly| The suction filter is very dirty| Clean or
replace the suction filter
Pneumatic tools have a high air consumption| Check the pneumatic tool air
consumption; seek an authorized compressed air dealer
Leaking on the compressor| Localize the leaking, contact the Güde service
center
Compressed-air pipeline leaking| Contact the Güde service center
Drain valve is open or missing| Close or insert the drain valve
Compressed air is released from the discharge valve under the pressure switch
when the appliance is being operated| The discharge valve is leaking| Clean or
replace the discharge valve
After reaching the cut-off pressure, the air is released from the discharge
valve under the pressure switch until the closing pressure is reached| Check
valve insert is leaking or defective| Clean or replace the check valve
insert16
The check valve is damaged| Replace the check valve
The compressor gets started too often| Too much condensation in the air jet|
Drain the condensate
Compressor is overloaded|
Safety valve blowing off| Pressure in the air jet exceeds the set cut-off
pressure| Have the pressure switch adjusted/re-placed by an authorized person
(Güde service centre)
The safety valve is defective| Replace the safety valve or contact the Güde
service center
The compressor getting warm too much| Air supply is not sufficient| Make sure
sufficient air supply and outlet (minimum distance from wall is 40 cm) is
provided
The cooling fins on the cylinder (cylinder head) are dirty| Clean the cooling
fins on the cylinder (cylinder head)
A too-long time of appliance operation| Switch the compressor off
The compressor overheated and keeps switching off| Compressor is overloaded|
Contact the Güde service center
Compressor is defective| Contact the Güde service center
Compressor under undervoltage| Contact the Güde service center
The outdoor temperature of 35°C|
Compressor
490/10/50 400V
420/10/50 EU 230V
580/10/50 EU 400V
415/10/50 N
420/10/100 EU 230V
580/10/100 EU 400V| #50008
50016
50018
50053
50071
50073| LwA 96dB(A)
LwA96 dB(A)
LwA 97dB(A)
LwA 96db(A)
LwA 96db(A)
LwA 97db(A)| LwAm 94,2 db(A)
LwAm94,3db(A)
LwAm95,3db(A)
LwAm94,2db(A)
LwAm94,3db(A)
LwAm95,3db(A)
---|---|---|---
LGarantierter Schallleistungspegel: Guaranteed sound power leve
LwAmGemessener Schallleistungspegel: Measured sound power leve
Appropriate EU Directives
2006/42 EG, 2004/108 EG, 2009/105/EG, 2000/14 EG Annex VI (Eurofins – Modulo
Uno S.p.A.
EN 1012:2010
EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 +
A14:2010
EN 60204-1:2011
EN 55014-1:2006 + A1:2009
EN 55014-2:1997 + A1:2001 + A2:2008
EN 61000-3-2:2006 + A1:2009 + A2:2009
EN 61000-3-3:2008
Güde GmbH & Co. KG
birkichstraße 6
74549 wolpertshausen
Germany
wolpertshausen, 2013-02-22
joachim bürkle,
GÜDE GmbH & Co. KG,
birkichstrasse 6, 74549 wolpertshausen,
Germany
Helmut Arnold
Technische Dokumentation
GÜDE GmbH & Co. KG
birkichstrasse 6
74549 wolpertshausen
Deutschland
Tel.: +49-(0)7904/700-0
Fax.: +49-(0)7904/700-250
EMail: info@guede.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>