- GENERAL SAFETY REGULATIONS
- DESCRIPTION OF THE MACHINE AND CONTENTS
- OPERATING INSTRUCTIONS
- PUTTING INTO OPERATION
- MAINTENANCE AND STORAGE
- WHAT TO DO “WHEN…”
- TECHNICAL SPECIFICATIONS
- DISPOSAL
- EU DECLARATION OF CONFORMITY
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
FVC 4011-EK
Submersible Garden Pump
USER’S MANUAL
FVC 4011-EK Submersible Garden Pump
Thank you for purchasing this pump. Before using it, please carefully read this User manual and keep it in a safe place for further use.
GENERAL SAFETY REGULATIONS
Important safety notice
Carefully unpack the product and take care not to throw away any part of the
packaging until all the product parts have been identified.
Read all warnings and instructions. Not following warnings or instructions may
lead to injury from an electric shock, fire and/or serious injuries.
ATTENTION ! Protect yourself against electric shock!
Packaging
The device is contained in a package intended to prevent any damage during
transport. This package is a resource and so it can be handed over for
recycling.
User manual
Before first using the pump, please read the following safety instructions and
the User manual. Learn about all the parts and the correct use of the device.
Keep the user’s manual in a safe place for easy future reference.
If giving the device to somebody else, do so together with the User manual.
Following the instructions in the included User manual is a prerequisite for
safe use of the garden appliance. The user’s manual also contains operating,
maintenance, and repair instructions.
NOTE : If you hand over the appliance to somebody else, do so together
with this user’s manual.
Make sure you use the appliance properly by following the instructions in the
included User manual. The user’s manual also contains operating, maintenance,
and repair instructions.
Electrical safety
The pump can be connected to any power plug installed according to the given
norms.
The plug must be powered at 230 V~ 50 Hz.
ATTENTION ! Important for the protection of your personal safety. Before
first starting your new submersible pump, have a professional check the
following items:
- Grounding
- Neutral conductor
The current circuit breaker must conform to energy safety norms and must fully
function correctly.
The electrical connection must be protected against moisture.
If there is a risk of the electrical connection being flooded, it must be
moved higher.
- In all situations, prevent the circulation of aggressive liquids and coarse materials.
The submersible pump must be protected against frost.
The pump must be protected against running when empty.
Prevent children from accessing parts of the pump by taking the appropriate
measures.
The manufacturer will not accept any responsibility for accidents or damage
resulting from not following the instructions in this manual.
DESCRIPTION OF THE MACHINE AND CONTENTS
Description of the machine (see Fig. 1.)
- Pump body
- Power cord
- Hose connection – 1“ or 1¼”
- Float switch
- Lower suction cover
OPERATING INSTRUCTIONS
Purpose of use
This pump may be used to transfer water from one location to another.
The appliance is intended for private household use and is not suitable for
professional applications.
It is not suitable for work with waste water in sewage systems, salt water,
aggressive or easily combustible substances, for work in food processing or as
a pump for water jets on garden ponds.
It is not designed for pumping drinking water!
NOTE : Before using the submersible pump, please first carefully read all
the safety instructions and instructions for use for the pump. Only after
reading these instructions will you be able to safely and reliably use all the
functions of the pump. You must conform to all local regulations in force in
your country. These regulations are effective together with the particulars
specified in these instructions.
ATTENTION ! If you will be using the pump near pools or garden ponds, or
in their protective zone, the electrical grid must be equipped with a circuit
breaker.
The pump must not be used if there are people in the pool or garden pond! Also
do not use it if there are fishes or other living creatures in the pool or
garden pond.
The submersible pump is designed to pump water at a maximum temperature of
35°C.
The pump must not be used for other liquids, particularly motor oils, cleaning
agents and other chemical products!
PUTTING INTO OPERATION
ATTENTION ! You should never install the pump by hanging it on the outlet
hose or power cord without additional support.
The submersible pump must be hung by the handle or placed on the tank bottom.
For the pump to function correctly, the pumped liquid must not contain foreign
objects that are larger than specified in the overview of technical
parameters.
After carefully reading these instructions you can prepare your pump for
operation, however, keep the following points in mind:
Check if the pump is standing on the tank bottom or hung by the handle.
Check if the discharge hose has been attached correctly.
Ensure that the moisture from the water can never get to the electrical power
source.
Prevent the pump from running empty.
Pump suction covers
The pump is equipped with 2 suction covers:
- Cover for suction of sludge water – this cover allows suction of water containing solid impurities up to 30 mm (Fig. 2).
- Clean water suction cover – with this cover it is possible to suck only slightly contaminated water with impurities up to 3 mm. The residual level is reduced by about 5 cm when using this cover (Fig. 3).
- Low Suction function – the pump can be used without covers to achieve complete suction of the water. This function is useful in case of flooded cellars or other areas. Water should be free of solid impurities.
The residual level reaches only 1 mm (Fig. 4). For this function, we recommend using a hose check valve.
Replacing the suction cover
Unscrew the cover screw (1) and then release the cover lock (2) by pulling it
away from the pump (Fig. 5). After fitting the new cover, secure it again with
the screw. ATTENTION ! The pump must not be dry operated.
ATTENTION ! Risk of running dry – The pump is cooled using the pumped
liquid. In the event of dry running, the pump motor may burn up.
MAINTENANCE AND STORAGE
This submersible pump is approved as a maintenance-free product undergoing
several final inspections.
We recommend you perform regular inspections and maintenance, which will
ensure a long lifetime and continuous performance.
ATTENTION ! Disconnect the power source before performing any
maintenance.
Maintenance
If the pump is regularly moved during operation, it should be rinsed out
after each use with clean water.
If the pump is permanently installed, the working order of the float switch
should be checked every 3 months.
Any fibrous deposits that could deposit themselves inside the pump, should be
removed using a water current.
If an excessive amount of debris accumulates in the body of the pump, flush
the pump out with clean water.
Storage
Store the thoroughly cleaned out pump in a dry place out of children’s reach.
WHAT TO DO “WHEN…”
When… | Causes | Repairs |
---|---|---|
The pump does not start | No power supply. | Check the power supply. |
The float won’t switch. | Check if the float got stuck. | |
No flow | The check valve is choked. | Clean the check valve. |
The pressure hose is bent. | Straighten the hose. | |
The pump does not turn off | The float cannot drop. | Check if the float got |
stuck.
Insufficient flow| The check valve is choked.| Clean the check valve.
Reduced pump capacity due to dirty and contaminated water.| Clean the pump and
flush the hose with clean water.
The pump turns off after a short time| The temperature fuse stops the pump due
to dirty water.| Disconnect the power plug. Clean the pump and the pumping
pit.
The water is too hot. The temperature fuse stops the pump.| Check that the
maximum water temperature of 35°C is not exceeded.
NOTE :
Not covered by the warranty:
Damage to the rotating mechanical gasket caused by running the pump empty, or
by foreign objects in the water
Blocking the running of the wheel with foreign objects
Damage during transport
Damage caused by unprofessional alterations
TECHNICAL SPECIFICATIONS
Voltage/Frequency | 230 V |
---|---|
Power input | 230 V~ 50 HZ |
Maximum transferred amount | 900W |
Maximum delivery | 17,200 l/h |
Maximum submersible depth | 8m |
Maximum temperature of the media | 7m |
Maximum value of solid particles in the media | 35°C |
Maximum pressure Weight | 0 – 30 mm |
DISPOSAL
INSTRUCTIONS AND INFORMATION ON DISPOSING OF USED PACKAGING MATERIALS
Dispose of used packaging material at a site designated for waste in your
municipality.
The appliance and its accessories are manufactured from various materials,
e.g. metal and plastic.
Take damaged parts to a recycling centre. Inquire at the relevant government
department.
This appliance meets all the basic requirements of the EU directives.
Changes in the text, design and technical specifications may be made without
prior notice and we reserve the right to make these changes.
User manual in the original language.
EU DECLARATION OF CONFORMITY
FAST CR, a.s.
U Sanitasu 1621, 251 01 Ricany, Czech Republic
tel.: +420 323 204 111, fax: +420 323 204 110
Product / brand: Submersible Pump / FIELDMANN
Type / model: FVC 4011-EK as factory model MC900E
AC 220-240V, 50Hz, 900W, Class I, IPX8
Manufacturer: FAST ČR, a.s.
U Sanitasu 1621, 251 01 Říčany, Czech Republic
VAT no: CZ24777749
This declaration of conformity is issued under the sole responsibility of the
manufacturer.
Person in charge of completing the technical documentation: FAST ČR, a.s.
The object of the declaration described above is in conformity with the
relevant Union harmonization legislation:
Directive MD 2006/42/EC Directive EMC 2014/30/EU
Directive RoHS 2011/65/EU+(EU)2015/863
The relevant harmonized standards and the other technical specifications:
EN 60335-1:2012+A11+A13+A1+A14+A2+A15 EN IEC 55014-1:2021
EN 60335-2-41:2003+A1+A2 EN IEC 55014-2:2021
EN 62233:2008 EN IEC 61000-3-2:2019+A1
EN ISO 12100:2010 EN 61000-3-3:2013+A1+A2
Place of issuance: Prague
Date of issuance: 05. 09. 2023
Name: Petr Uher – Responsible Person
Signature:
1€0:24777749, DiC:CZ24777749